The city administrator presented to the commission the subdivision plat
submitted. Fdllowing lengthy discussion concerning building lines and
side yard requirement with representatives of North, Lake Woodlands
(Steve Parsons, and Al Wilkie), motion was made by Charles Williams
and seconded by Wayne Musgrave to approve the plat essentially as
submitted with the corrections and changes recommended by and
acceptable to the city's consulting engineers. A copy of those reccom-
mendations is attached here for reference. Motion carried 3 -IF with
Chairman Fitzgerald opposing.
Charles Williams then made a motion to adjourn the meeting, seconded
by Wayne Musgrave, and motion carried unanimously.
The meeting was adjourned.
ZZ �,
Chairman
Secretary
21-
Rady and Associates, Inc.
Consulting Engineers
August 22, 1976
City of Coppell
Att: George Campbell
City Administrator
P.O. Box 478
Coppell, Texas 75019
RE: 7213, Final Plat
and Plan Review for
North Lake Woodlands
(Second Section)
Dear George:
The final plat and plans of North Lake Woodlands has
been reviewed as requested. The final plat and plans
are in general conformance to the subdivision regulations.
The following requirements will insure the development
in accordance with Coppell's subdivision regulations.
I. Final Plat Review
1. Permanent survey monuments should be set, described
at the termination of all boundary calls and drafted
onto the final plat at all block and lot corners
of the subdivision.
2. The scale of the final plat and the Engineer's
seal should appear on the final plat.
II: Construction Plan Review
1. It is our understanding that the City of Coppell
made exception to their subdivision regulations
to approve the proposed non -curb and gutter, 28
foot wide street section, with a 6" lime stabilized
sub -grade, a 6" Crushed Stone base and 1-1/2"
H.M.A.C. Surface coarse pavement.
2. The plans propose the installation of two
15" R.C.P. culverts. The minimum size for storm
drain culverts should be 18" to prevent stoppages.
400 Continental Life Building • Fort Worth, Texas 76102 • 817-335-6511
Joe J. Rady, P.E. 9 J. R. King,Jr., P.E. 0 Glen Arnold, P.E. 0 Paul D. Gregory, P.E. • Derrell Johnson, P.E.
Mr. George Campbell, City Administrator
Page 2.
Computations should be furnished to insure that
the culvert sizes selected will have adequate
capacities for the designed drainage areas.
The plans should also indicate the size, grade,
and capacity of the channel sections paralleling
Briarcove Lane and Hunter's Ridge Road.
The plans should include details for the "Type
X inlet" proposed at the intersection of Hunter's
Ridge Road and Briarcove Lane.
The plans propose two "Type X inlets" on
Briarcove Lane at station 4 + 60. The plans should
indicate the size pipe, grades, headwalls, etc.
of the drainage pipe connecting the inlets and
discharging into the drainage channel "B -B".
3. The sanitary sewer plans propose a 6 sewer
main at a 0.40% grade. The sewer lines should be
designed to meet Texas State Department of Health
Resources Standards which require a minimum velocity
in sewer mains of 2.0 feet per second. Therefore,
a minimum grade for 6" mains of 0.60% is recommended.
If additional information or clarification is needed,
do not hesitate to call.
Very truly yours,
RADY AND ASSOCIATES, INC.
CONSULTING ENGINEERS
By .
Lewis Herrin P.E.