Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BP 2024-09-19 PZ
Planning & Zoning Commission City of Coppell, Texas Meeting Agenda 255 E. Parkway Boulevard Coppell, Texas 75019-9478 255 Parkway Blvd.6:00 PMThursday, September 19, 2024 Edmund Haas Glenn Portman (Chair) (Vice Chair) Cindy Bishop Sue Blankenship Freddie Guerra Kent Hafemann Ed Maurer Notice is hereby given that the Planning and Zoning Commission of the City of Coppell, Texas,will meet on Thursday, September 19, 2024, in Regular Called Session at 6:00 p.m. for Work Session, and Regular Session at 6:30 p.m., at Town Center, 255 Parkway Boulevard, Coppell, Texas. As authorized by Section 551.071(2) of the Texas Government Code, this meeting may be convened into closed Executive Session for the purpose of seeking confidential legal advice from the City Attorney on any agenda item listed herein. The City of Coppell reserves the right to reconvene, recess or realign the Work Session, or called Executive Session, or order of business, at any time prior to adjournment. As authorized by Section 551.127, of the Texas Government Code, one or more commissioners or employees may attend this meeting remotely using videoconferencing technology. The purpose of this meeting is to consider the following items: Regular Session (Open to the Public) 1.Call To Order 2.Work Session (Open to the Public) a. Discussion about Joint Meeting 3.Regular Session (Open to the Public) 4.Citizens Appearance Page 1 City of Coppell, Texas Printed on 9/14/2024 1 September 19, 2024Planning & Zoning Commission Meeting Agenda Provide an opportunity for citizens to address the Planning and Zoning Commission on any matter. Anyone wishing to address the commission should register prior to the start of the meeting. There is a two (2) minute time limit for each citizen to speak however, additional time may be granted by the commissioners. The Planning and Zoning Commission is not permitted to take action on any subject raised by a speaker during Citizens' Appearance. 5.Consider approval of the August 15, 2024, Planning & Zoning meeting minutes. August 15, 2024, Planning & Zoning Meeting Minutes.pdfAttachments: 6.PUBLIC HEARING: Consider approval of Stonelake Skyport Replat, Lot 1, Block A, a replat to modify a lot for the creation of two office warehouse buildings and associated easements and fire lane reconfiguration on 16.07 acres of property located at the northeast corner of S. Royal Lane and Gateway Blvd., being developed by SL7 DFW Industrial, L.P., being represented by Neda Hossieny, Kimley-Horn & Associates. STAFF REP.: Matthew Steer Staff Report.pdf Replat.pdf Attachments: 7.Consider approval of Stonelake Skyport Site Plan, Lot 1, Block A, a site plan for two office/warehouse buildings (117,608 & 164,904 sq. ft.) and associated easements and fire lane configuration on 16.07 acres of property, located at the northeast corner of S. Royal Lane and Gateway Blvd., being developed by SL7 DFW Industrial, L.P., being represented by Neda Hossieny, Kimley-Horn & Associates. STAFF REP.: Matthew Steer Staff Report.pdf 1. Site Plan.pdf 2. Tree Preservation Plan.pdf 3. Landscape Plan.pdf 4. Buildings 1 & 2 Elevations.pdf 5. Trip Gen Memo.pdf Attachments: 8.Update on City Council 9.Adjournment Page 2 City of Coppell, Texas Printed on 9/14/2024 2 September 19, 2024Planning & Zoning Commission Meeting Agenda CERTIFICATE I certify that the above Notice of Meeting was posted on the bulletin board at the City Hall of the City of Coppell, Texas on this 13th day of September, 2024, at _____________. ______________________________ Kami McGee, Board Secretary PUBLIC NOTICE - STATEMENT FOR ADA COMPLIANCE The City of Coppell acknowledges its responsibility to comply with the Americans With Disabilities Act of 1990. Thus, in order to assist individuals with disabilities who require special services (i.e. sign interpretative services, alternative audio/visual devices, and amanuenses) for participation in or access to the City of Coppell sponsored public programs, services and/or meetings, the City requests that individuals make requests for these services seventy-two (72) hours – three (3) business days ahead of the scheduled program, service, and/or meeting. To make arrangements, contact Kori Allen, ADA Coordinator, or other designated official at (972) 462-0022, or (TDD 1-800-RELAY, TX 1-800-735-2989). Page 3 City of Coppell, Texas Printed on 9/14/2024 3 255 E. Parkway Boulevard Coppell, Texas 75019-9478City of Coppell, Texas Minutes Planning & Zoning Commission 6:00 PM 255 Parkway Blvd.Thursday, August 15, 2024 Edmund Haas Glenn Portman (Chair) (Vice Chair) Cindy Bishop Sue Blankenship Freddie Guerra Kent Hafemann Ed Maurer PRESENT: Chairman, Edmund Haas; Vice Chair, Glenn Portman; Commissioner, Sue Blankenship; Commissioner Ed Maurer; Commissioner, Freddie Guerra; and Commissioner, Cindy Bishop via Zoom. ABSENT: Commissioner, Kent Hafemann Also present were Mary Paron-Boswell, Senior Planner; Matt Steer, Development Services Administrator; Luay Rahil, Assistant Director of Community Development; Cole Baker, E.I.T., Graduate Engineer; Dezirae Veuleman, Code Compliance Officer; Rachel Rosenstern, Code Compliance Officer; Lauren Schellenberger, Code Compliance Officer; and Ashley Owens, City Secretary. Notice was given that the Planning and Zoning Commission of the City of Coppell, Texas, met on Thursday, August 15, 2024, in Regular Called Session at 6:00 p.m. for Work Session, and Regular Session at 6:30 p.m., at Town Center, 255 Parkway Boulevard, Coppell, Texas. As authorized by Section 551.071(2) of the Texas Government Code, this meeting may be convened into closed Executive Session for the purpose of seeking confidential legal advice from the City Attorney on any agenda item listed herein. The City of Coppell reserves the right to reconvene, recess or realign the Work Session, or called Executive Session, or order of business, at any time prior to adjournment. As authorized by Section 551.127, of the Texas Government Code, one or more commissioners or employees may attend this meeting remotely using videoconferencing technology. The purpose of this meeting was to consider the following items: Page 1City of Coppell, Texas 5 August 15, 2024Planning & Zoning Commission Minutes Regular Session (Open to the Public) Call to order1. Chairman Haas called the meeting to order at 6 p.m. Work Session (Open to the Public)2. Regular Session (Open to the Public)3. Chairman Haas called the Regular Session to order at 6:30 p.m. Citizens Appearance4. Chairman Haas advised that no one signed up to speak at Citizens Appearance. 5.Consider approval of the July 18, 2024, Planning and Zoning meeting minutes. A motion was made by Vice Chair Portman, seconded by Commissioner Maurer, to approve the minutes of the July 18, 2024, Planning and Zoning meeting. The motion was approved unanimously, 6-0. 6.PUBLIC HEARING: Consider approval of PD-109R3-SF-9, 619 Oakbend Drive (STR), a zoning change request from PD-109-SF-9 (Planned Development- 109 - Single-Family-9) to PD-109R3-SF-9 (Planned Development- 109 Revision 3- Single-Family-9) to consider allowing a Short-Term Rental on 0.74 acres of property located at 619 Oakbend Drive, at the request of Scott Young, the property owner. Mary Paron-Boswell, Senior Planner, presented the case with exhibits stating that staff is unable to recommend approval of this request. Should the Commission choose to recommend approval of this request, staff would recommend the following conditions: 1. PD Conditions: a. To obtain a STR permit prior to their current one expiring. b. Notify staff of any change of property ownership. c. Limit the rental to four rooms for less than 30 days. Applicant, Scott Young, 619 Oakbend Dr., presented his case and answered questions of the commission. Chairman Haas opened the Public Hearing and asked for those who signed up to speak: 1) Jacque Bresnahan, 607 Oakbend Dr., spoke against the proposed request. 2) Tom Bresnahan, 607 Oakbend Dr., spoke against the proposed request. 3) Ali Askari, 104 Branchwood Tr., spoke against the proposed request. Page 2City of Coppell, Texas 6 August 15, 2024Planning & Zoning Commission Minutes 4) Elisabeth Nelson, 618 Oakbend Dr., spoke against the proposed request. 5) Case Carpenter, 146 Oakbend Dr., spoke against the proposed request. 6) Nanci Bookout, 623 Oakbend Dr., spoke against the proposed request. 7) Brent Bookout, 623 Oakbend Dr., spoke against the proposed request. 8) Julie Simpson, 117 Branchwood Tr., spoke against the proposed request. 9) Duwayne Willett, 701 Post Oak Dr., spoke against the proposed request. 10) Jack Clark, 718 Beal Ln., spoke against the proposed request. 11) Lauren Willett, 701 Post Oak Dr., spoke against the proposed request. 12) Cecilia Tanaka, 176 Branchwood Tr., spoke against the proposed request. Scott Young, 619 Oakbend Dr., applicant, stated he would like to withdraw his request. 13) Doug Maxey, 599 Oakbend Dr., spoke against the proposed request. 14) Tina Chapman, 608 Autumnwood Ln., spoke against the proposed request. 15) Connor Lipscomb, 712 Post Oak Dr., spoke against the proposed request. 16) David Tovson, 623 Beal Ln., spoke against the proposed request. 17) Colby Bookout, 623 Oakbend Dr., spoke against the proposed request. Chairman Haas closed the Public Hearing. The agenda item request was withdrawn by the applicant and no further action or motion was necessary. Update on City Council7. Chairman Haas stated that the commission was updated on City Council items during Work Session. Adjournment8. There being no further business before the Commission, Chairman Haas adjourned the meeting at 8:04 p.m. ______________________________ Edmund Haas, Chair ______________________________ Kami McGee, Board Secretary Page 3City of Coppell, Texas 7 ITEM 6 Page 1 of 2 CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT Stonelake Skyport Addition, Replat, Lot 1, Block A P&Z HEARING DATE: September 19, 2024 STAFF REP.: Matthew Steer, AICP, Development Services Administrator LOCATION: Northeast corner of South Royal Lane and Gateway Boulevard SIZE OF AREA: 16.07 acres of property CURRENT ZONING: LI (Light Industrial) REQUEST: A replat to modify a lot for the creation of two office warehouse buildings and associated easements and fire lane reconfiguration. APPLICANT: Developer: Engineer: SL & DFW Industrial, LP Neda Hossieny, P.E. 100 Crescent Court, Suite 850 Kimley-Horn & Associates Dallas, TX 75201 13455 Noel Road, Two Galleria Office Tower, Ste. 700 Bwilson@stonelake.com Dallas, TX 75240 Neda.Hossieny@Kimley-Horn.com HISTORY: This property is zoned Light Industrial (LI) and has been used as a Park’n Fly location since 1995. A Site Plan for a similar Office/Warehouse Development was approved in October 2022 for redevelopment of this site. The plat was never filed of record. TRANSPORTATION: South Royal Lane is a four-lane divided thoroughfare built within a 110-foot right-of-way. South of the property Gateway Boulevard is a two-lane undivided thoroughfare built within a 70-foot right-of-way at this segment. SURROUNDING LAND USE & ZONING: North – DART Rail Line & Light Industrial (LI) South – LBJ Freeway East - Office Warehouse; Light Industrial (LI) West – Vacant Land (LI) COMPREHENSIVE PLAN: Coppell 2030, A Comprehensive Master Plan, indicates this property as Freeway Special District. 10 ITEM 6 Page 2 of 2 DISCUSSION: This is a simple replat request. This is a companion item to Stonelake Skyport Development, where they are proposing two office warehouse buildings. This plat will create one lot and dedicate associated easements and fire lanes on the property. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff is recommending APPROVAL of the Stonelake Skyport Addition Replat, subject to the following conditions: 1. A variance be granted to allow for the driveway configuration as shown for the South Royal Lane entry. 2. There may be additional comments at the time of Detail Engineering Review and Building Permit. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: 1. Recommend approval of the request 2. Recommend disapproval of the request 3. Recommend modification of the request ATTACHMENTS: Replat 11 GAT E W A Y B O U L E V A R D (VA R I A B L E W I D T H R I G H T - O F - W A Y ) ST. LOUIS & SOUTHWE S T E R N R A I L R O A D (100' RIGHT-OF-WAY) (VOL. 95, PG. 518) 24' FIRE LANE EASEMENT VOL.95127, PG. 4328 D.R.D.C.T. ABANDONED BY THIS PLAT 10' SETBACK VOL. 95127, PG. 4328 D.R.D.C.T. 10' SETBACK VOL. 95127, PG. 4328 D.R.D.C.T. ABANDONED BY THIS PLAT 15' WATER EASEMENT VOL. 95127, PG. 4328 D.R.D.C.T. ABANDONED BY THIS PLAT 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 D.R.D.C.T. 20' UTILITY EASEMENT VOL. 95127, PG. 4328 D.R.D.C.T. 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 D.R.D.C.T. 10' SETBACK VOL. 95127, PG. 4328 D.R.D.C.T.S. ROYAL LANE(VARIABLE WIDTH RIGHT-OF-WAY)15' LANDSCAPE EASEMENT VOL. 95127, PG. 4328 D.R.D.C.T. 60' SETBACK VOL. 95127, PG. 4328 D.R.D.C.T. PARK 'N FLY ADDITION VOL. 95127, PG. 4328 D.R.D.C.T. CALLED 16.071 ACRES SL7 DFW INDUSTRIAL, LP INST. NO. 202400139171 O.P.R.D.C.T. LOT 1R-2, BLOCK 2 GATEWAY BUSINESS PARK REPLAT INST. NO. 201700235650 O.P.R.D.C.T. LANTHIAN COPPELL TX LLC INST. NO. 202300259370 O.P.R.D.C.T. 24' FIRE LANE EASEMENT VOL.95127, PG. 4328 D.R.D.C.T. ABANDONED BY THIS PLAT 24' FIRE LANE EASEMENT VOL. 95127, PG. 4328 D.R.D.C.T. ABANDONED BY THIS PLAT 24' FIRE LANE EASEMENT VOL.95127, PG. 4328 D.R.D.C.T. ABANDONED BY THIS PLAT 24' FIRE LANE EASEMENT VOL.95127, PG. 4328 D.R.D.C.T. ABANDONED BY THIS PLAT 15' WATER EASEMENT VOL. 95127, PG. 4328 D.R.D.C.T. ABANDONED BY THIS PLAT 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 D.R.D.C.T. 20' UTILITY EASEMENT VOL. 90138. PG. 4289 D.R.D.C.T. 20' UNDERGROUND DRAINAGE & UTILITY EASEMENT VOL. 95136, PG. 3876 VOL. 96167, PG. 7179 D.R.D.C.T. 15' TU ELECTRIC EASEMENT VOL. 95136, PG. 3876 D.R.D.C.T. 24' FIRE LANE EASEMENT INST. NO. 201700235650 O.P.R.D.C.T. 20' TU ELECTRIC EASEMENT VOL. 96167, PG. 7179 D.R.D.C.T. LOT 1, BLOCK A 16.0714 ACRES 700,072 SQ. FT. N85°31'02"E 841.31'S0°03'01"E1068.65'N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' N70 ° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'1/2" IRFC "WAI" P.O.B. 392. 0 2 ' 238. 2 9 ' N68°24'41"E 104.76' N54° 2 9' 2 0" E 112. 9 5' N 5 6 ° 3 5 ' 0 4 " W 14 4 . 5 3 'L1L2L3L4 L5 L6 15' WATER EASEMENT BY THIS PLAT 15' WATER EASEMENT BY THIS PLATL14L1531.43' 20' WATER EASEMENT BY THIS PLAT VARIABLE WIDTH FIRELANE EASEMENT BY THIS PLAT 24.0'24.0' VARIABLE WIDTH FIRELANE EASEMENT BY THIS PLAT VARIABLE WIDTH FIRELANE EASEMENT BY THIS PLAT VARIABLE WIDTH FIRELANE EASEMENT BY THIS PLATVARIABLE WIDTH FIRELANE EASEMENT BY THIS PLAT VARIABLE WIDTH FIRELANE EASEMENT BY THIS PLAT VARIABLE WIDTH FIRELANE EASEMENT BY THIS PLAT 60' SETBACK LINE BY THIS PLAT 60.0'EASEMENT TIE ONLY EASEMENT TIE ONLY 47.01' L7 C1 C2 C3 C4N0°03'01"W184.13'C5 N85°31'02"E 383.55' C6 N89°56'59"E 234.60'C7 S0°03'01"E778.67'C8 N70° 5 6 ' 4 4 " W 291. 3 7 ' C9 C10 C11C1 2 L8 C13C14C15C16C17 L9 C18 C19 C20 C21 N70 ° 5 6 ' 4 4 " W 115. 6 1 'N0°03'01"W290.69'S0°03'01"E548.47'S89°58'18"W 232.24'N0°03'01"W125.37'N0°02'45"W129.01'N0°03'01"W60.00'S70° 5 6 ' 4 4 " E 117. 6 9 ' S89°56'59"W 235.76'N0°03'01"W778.67'S70° 5 6 ' 4 4 " E 304. 1 0 'S0°03'01"E197.85'S0°03'01"E60.00'S0°03'01"E167.10'C22 L10 C23 L11 C24C25C26L12C27C28L13C29C30C31L16C32L17C3 3 C3 4 C35C36L18 C37C38L19C39C40L20C41C42C43L21C44 L22 273.28'SEE DETAIL A 24.0'24.0'30.0'SIDEWALK EASEMENT BY THIS PLAT SEE DETAIL A SIDEWALK EASEMENT BY THIS PLAT SEE DETAIL B LINE TABLE NO. L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 BEARING S33°24'56"W S56°35'04"E N33°24'56"E S89°56'59"W S00°03'01"E N89°56'59"E N89°56'59"E N83°32'35"W S89°56'59"W S85°31'02"W LENGTH 15.00' 15.00' 15.00' 20.43' 15.00' 20.49' 3.99' 55.65' 17.00' 33.69' LINE TABLE NO. L11 L12 L13 L14 L15 L16 L17 L18 L19 L20 BEARING N00°03'01"W N18°16'45"E N18°22'52"W N19°03'16"E N19°03'16"E N00°03'01"W S83°32'37"E S20°36'30"W S18°16'45"W S18°22'48"E LENGTH 5.50' 18.61' 18.61' 16.85' 15.45' 8.67' 69.84' 5.89' 18.61' 18.61' CURVE TABLE NO. C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25 C26 C27 C28 C29 DELTA 47°12'56" 45°19'05" 51°06'54" 36°59'16" 85°34'03" 4°25'57" 90°00'00" 109°06'17" 30°46'35" 79°14'55" 18°26'42" 102°35'50" 12°35'50" 70°53'43" 36°52'12" 36°52'12" 6°28'42" 27°42'52" 11°11'01" 35°01'54" 5°12'33" 85°34'03" 89°56'59" 20°49'50" 20°49'50" 18°19'47" 18°19'47" 18°19'51" 18°19'51" RADIUS 30.00' 50.00' 10.00' 30.00' 54.00' 54.00' 54.00' 54.00' 30.00' 30.00' 30.02' 30.00' 355.00' 54.00' 30.00' 30.00' 6.19' 30.00' 54.00' 30.00' 80.00' 30.00' 10.00' 100.00' 100.00' 100.00' 100.00' 100.00' 100.00' LENGTH 24.72' 39.55' 8.92' 19.37' 80.65' 4.18' 84.82' 102.83' 16.11' 41.49' 9.66' 53.72' 78.05' 66.82' 19.31' 19.31' 0.70' 14.51' 10.54' 18.34' 7.27' 44.80' 15.70' 36.36' 36.36' 31.99' 31.99' 31.99' 31.99' CHORD BEARING N66°20'31"E N65°23'36"E N62°29'41"E N18°26'37"E N42°44'00"E N87°44'00"E S45°03'01"E S54°30'07"W N86°20'02"W S38°41'43"W N29°42'22"E N32°14'39"W N77°14'39"W N35°29'53"W N18°29'07"W N18°29'07"W S87°59'43"W S76°05'33"W S67°49'38"W S55°54'11"W S35°46'57"W S42°44'00"W N45°01'31"W N10°24'55"W N10°24'55"W N09°06'52"E N09°06'52"E N09°12'57"W N09°12'57"W CHORD 24.03' 38.52' 8.63' 19.03' 73.36' 4.18' 76.37' 87.98' 15.92' 38.26' 9.62' 46.82' 77.89' 62.64' 18.97' 18.97' 0.70' 14.37' 10.52' 18.06' 7.27' 40.75' 14.14' 36.16' 36.16' 31.85' 31.85' 31.86' 31.86' CURVE TABLE NO. C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C50 C51 C52 C53 DELTA 20°46'19" 20°43'17" 96°06'11" 70°53'43" 90°00'00" 109°06'17" 89°47'50" 20°39'31" 18°19'47" 18°19'47" 18°19'47" 18°19'47" 20°46'19" 20°43'17" 85°33'18" 6°45'06" 37°51'20" 11°41'32" 35°56'45" 18°08'56" 35°56'45" 11°41'32" 37°51'20" 27°41'54" RADIUS 100.00' 100.00' 30.00' 30.00' 30.00' 30.00' 20.01' 3.00' 100.00' 100.00' 100.00' 100.00' 100.00' 100.00' 30.00' 102.00' 81.69' 519.18' 118.79' 190.08' 128.79' 509.18' 91.69' 92.00' LENGTH 36.25' 36.17' 50.32' 37.12' 47.12' 57.13' 31.37' 1.08' 31.99' 31.99' 31.99' 31.99' 36.25' 36.17' 44.80' 12.02' 53.98' 105.95' 74.53' 60.21' 80.80' 103.91' 60.58' 44.48' CHORD BEARING N10°20'08"E N10°21'39"E N48°00'04"E S35°29'53"E N45°03'01"W N54°30'07"E S24°18'06"E S10°16'44"W S09°06'52"W S09°06'52"W S09°12'55"E S09°12'55"E S10°20'08"W S10°21'39"W S42°44'00"W S30°21'41"E S45°54'48"E S58°59'42"E S71°07'18"E N80°01'13"W N71°07'18"W N58°59'42"W N45°54'48"W N40°50'05"W CHORD 36.06' 35.97' 44.62' 34.80' 42.43' 48.88' 28.25' 1.08' 31.85' 31.85' 31.85' 31.85' 36.06' 35.97' 40.75' 12.01' 53.00' 105.76' 73.31' 59.96' 79.48' 103.73' 59.49' 44.04' LINE TABLE NO. L21 L22 L23 L24 L25 L26 L27 L28 L29 BEARING S00°03'01"E S85°31'02"W S44°56'59"W S00°03'01"E S45°03'01"E S45°03'01"E S00°03'01"E S44°56'59"W S19°03'16"W LENGTH 16.01' 30.15' 20.92' 85.80' 21.68' 7.47' 70.19' 6.85' 2.00'273.28'0.48'S. ROYAL LANE(VARIABLE WIDTHRIGHT-OF-WAY)213.77'14.19' 63.99' 32.61' 32.61' 15.00' L23L24L25L26L27L2837.77' SIDEWALK EASEMENT BY THIS PLAT N56°35'04"W 239.35' GATEWAY BOULEVARD (VARIABLE WIDTH RIGHT-OF-WAY) 37.91' 201.44' 45.08' 56.02' C4 5 C46 C47C48 L29 C49 C50 C51 C52 C53 REPLAT STONELAKE SKYPORT ADDITION LOT 1, BLOCK A, BEING A REPLAT OF PARK 'N FLY ADDITION S.A. & M.G. RAILROAD SURVEY, ABSTRACT NO. 1439 16.0714 ACRES DATE OF PREPARATION: 9/11/24 CITY OF COPPELL, DALLAS COUNTY, TEXAS DWG NAME: K:\DTD_SURVEY\064405644-STONELAKE PARKNFLY 800 ROYAL GATEWAY COPPELL\DWG\064405644-STONELAKE PARKNFLY 800 ROYAL GATEWAY COPPELL_RP_.DWG PLOTTED BYVALDEZ, LEONARDO 9/11/2024 11:01 AM LAST SAVED9/11/2024 10:12 AMScale Drawn by LDV1" = 50' Checked by Date Project No.Sheet No. Suite 1100, Dallas, Texas 75226 2500 Pacific Avenue, Tel. No. (469) 718-8849FIRM # 10115500 JAD Sep. 2024 064405644 1 OF 2 NORTH GRA P E VI N E CREEK IRVING CITY L IM IT COWBOY KAYE BETHEL COUNTYLINECOTTON SPANISH MOSS ANDERSONCOZBY BROOKS DILLARD LOCHHAMMONDBURNS COPPELLSOUTHWESTERN AIRLINEFREEPORTPIKWYROYALCOUNTY LINEWRAN GLE R STATESMAN ROYAL27 THESTERSSTERLING CURRENCYFRE E P O R T FRE E P O R T PROSPECTREGENTPKWYDART DALLASCITYLIMIT11TH BETH E L SANDERS LOOPCITYLIMITOAK BROOK OAKCRESTHARRISHOWELLBULLOCKDENTON TAPBELT LINECOPPELL COWBOY VAN ZANDTHYPER-BOLICBELT LINEHACKBERRY ME A D O W 635 114 WEIVKEERC COPPELLN.T.S. VICINITY MAP SITE NORTH LINE TYPE LEGEND BOUNDARY LINE ADJACENT PROPERTY LINE EASEMENT LINE BUILDING LINE LEGEND P.O.B. = POINT OF BEGINNING IRSC = 5/8" IRON ROD W/ "KHA" CAP SET IRFC = IRON ROD W/CAP FOUND FF = FINISHED FLOOR ELEVATION SQ. FT. = SQUARE FEET VOL. PG. = VOLUME PAGE D.R.D.C.T. = DEED RECORDS OF DALLAS COUNTY, TEXAS O.R.D.C.T. = OFFICIAL RECORDS, DALLAS COUNTY, TEXAS OWNER: SL7 DFW INDUSTRIAL, LP 100 CRESCENT COURT, SUITE 850, DALLAS, TEXAS 75201 CONTACT: BLAKE WILSON PHONE: 214-220-7297 SURVEYOR: KIMLEY-HORN AND ASSOC., INC. 2500 PACIFIC AVENUE, SUITE 1100 DALLAS, TEXAS 75226 CONTACT: J. ANDY DOBBS, R.P.L.S. PHONE: 972-770-1300 EMAIL:ANDY.DOBBS@KIMLEY-HORN.COM GENERAL NOTES: 1.The basis of bearings is based on State Plane Coordinate System, Texas North Central Zone 4202, North American datum of 1983 (Adjustment Realization - 2011). 2.Monuments shown hereon are 5/8-inch iron rods with red plastic caps stamped "KHA" set, unless noted otherwise. 3.A variance is being requested to allow for the driveway configuration as shown for the S. Royal Lane entry. ENGINEER: KIMLEY-HORN AND ASSOC., INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 CONTACT: NEDA HOSSEINY, P.E. PHONE: 972-770-1300 EMAIL: NEDA.HOSSEINY@KIMLEY-HORN.COM FLOOD STATEMENT: According to Federal Emergency Management Agency's Flood Insurance Rate Map No. 48113C0135K, for Dallas County, Texas and incorporated areas, dated 7/7/2014, this property is is not within an identified special flood hazard area. If this site is not within an identified special flood hazard area, this flood statement does not imply that the property and/or the structures thereon will be free from flooding or flood damage. On rare occasions, greater floods can and will occur and flood heights may be increased by man-made or natural causes. This flood statement shall not create liability on the part of the surveyor Purpose Statement: The purpose of this plat is to abandon existing easements and dedicate new easements. GRAPHIC SCALE IN FEET 050 25 50 100 1"=50' @ 24"X36" DETAIL A NORTH SCALE = 1:40 DETAIL B SCALE = 1:40 NOR T H 12 Copyright © 2024 Kimley-Horn and Associates, Inc. All rights reserved DWG NAME: K:\DTD_SURVEY\064405644-STONELAKE PARKNFLY 800 ROYAL GATEWAY COPPELL\DWG\064405644-STONELAKE PARKNFLY 800 ROYAL GATEWAY COPPELL_RP_.DWG PLOTTED BYVALDEZ, LEONARDO 9/11/2024 11:01 AM LAST SAVED9/11/2024 10:12 AMScale Drawn by LDVN/A Checked by Date Project No.Sheet No. Suite 1100, Dallas, Texas 75226 2500 Pacific Avenue, Tel. No. (469) 718-8849FIRM # 10115500 JAD Sep. 2024 064405644 2 OF 2 OWNERS CERTIFICATE WHEREAS, SL7 DFW INDUSTRIAL, LP, is the owner of a tract of land situated in the S.A. & M.G. Railroad Survey, Abstract No. 1439, City of Coppell, Dallas County, Texas and being all of Park 'N Fly addition, an addition to the City of Coppell, recorded in Volume 95127, Page 4328, Deed Records, Dallas County, Texas, and being all of a called 16.071 acre tract of land described in Special Warranty Deed to SL7 DFW INDUSTRIAL, LP, recorded in Instrument No. 202400139171, Official Public Records, Dallas County, Texas, and being more particularly described as follows: BEGINNING at a 1/2" iron rod with plastic cap stamped “WAI” found for the southeast corner of said 16.071 acre tract and the southwest corner of Lot 1R-2, Block 2, Gateway Business Park Replat, recorded in Instrument No. 201700235650 of said Official Public Records, in the north right-of-way line of Gateway Boulevard (variable width right-of-way); THENCE with said north right-of-way line of Gateway Boulevard, the following courses and distances: North 56°35'04" West, a distance of 239.35 feet to a 5/8” iron rod with red plastic cap stamped “KHA” set for corner; North 70°56'44" West, a distance of 673.89 feet to a 5/8” iron rod with red plastic cap stamped “KHA” set for the southwest corner of said 16.071 acre tract, at the intersection of said north right-of-way line of Gateway Boulevard and the east right-of-way line of South Royal Lane (variable width right-of-way); THENCE with said east right-of-way line of South Royal Lane, North 00°15'27" West, a distance of 651.09 feet to a 5/8” iron rod with red plastic cap stamped “KHA” set for the northwest corner of said 16.071 acre tract, at the intersection of said east right-of-way line of South Royal Lane and the south right-of-way line of St. Louis & Southwestern Railroad (100-foot right-of-way); THENCE with said south right-of-way line of St. Louis & Southwestern Railroad, North 85°31'02" East, a distance of 841.31 feet to a 5/8” iron rod with red plastic cap stamped “KHA” set for the northeast corner of said 16.071 acre tract and the northwest corner of said Lot 1R-2; THENCE with the east line of said 16.071 acre tract and the west line of said Lot 1R-2, South 00°03'01" East, a distance of 1,068.65 feet to the POINT OF BEGINNING and containing 700,072 square feet or 16.0714 acres of land. Bearing system based on the State Plane Coordinate System of 1983, Texas North Central Zone (4202), North American Datum of 1983 (2011). SURVEYOR’S STATEMENT: I, J. Andy Dobbs, a Registered Professional Land Surveyor, licensed by the State of Texas, affirm that this plat was prepared under my direct supervision, from recorded documentation, evidence collected on the ground during field operations and other reliable documentation; and that this plat substantially complies with the Rules and Regulations of the Texas Board of Professional Engineers and Land Surveyors, the City of Copell Regulations. Dated this the __________ day of ___________________________, 20__. _______________________________________ J. Andy Dobbs Date Registered Professional Land Surveyor No. 6196 KIMLEY-HORN AND ASSOC., INC. 2500 Pacific Avenue, Suite 1100 Dallas, Texas 75226 469-718-8849 andy.dobbs@kimley-horn.com STATE OF TEXAS § COUNTY OF DALLAS § BEFORE ME, the undersigned, a Notary Public in and for the said County and State, on this day personally appeared J. Andy Dobbs known to me to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same for the purpose therein expressed and under oath stated that the statements in the foregoing certificate are true. GIVEN UNDER MY HAND AND SEAL OF OFFICE this ____________ day of ____________________ 2024. _______________________________________ Notary Public in and for the State of Texas The Replat of STONELAKE SKYPORT ADDITION is hereby approved pursuant to Section 212.0065 of the Texas Local Government Code. The Director of Community Development may approve minor plats or replats involving four or fewer lots fronting on an existing street and not requiring the creation of any new street or the extension of municipal facilities. __________________________________ _____________ Director of Community Development Date ATTEST: __________________________________ _____________ Planning & Zoning Commission Secretary Date Floodplain Development Permit Application No. N/A has been filed with the City of Coppell Floodplain Administration on _______________, 2024. _________________________________ ______________ Floodplain Administrator Date NOW THEREFORE, KNOW ALL MEN BY THESE PRESENTS: That SL7 DFW INDUSTRIAL, LP, does hereby adopt this plat, designating the herein described property as STONELAKE SKYPORT ADDITION, LOT 1, BLOCK A an addition to the City of Coppell, Dallas County, Texas, and do hereby dedicate, in fee simple, to the public use forever any streets, alleys and floodway management areas shown thereon. The easements shown thereon are hereby reserved for the purposes indicated. The utility and fire lane easements shall be open to the public, fire and police units, garbage and rubbish collection agencies, and all public and private utilities for each particular use. The maintenance of paving on the utility and fire lane easements is the responsibility of the property owner. No buildings, fences, trees, shrubs, or other improvements or growths shall be constructed, reconstructed or placed upon, over or across the easements as shown. Said easements being hereby reserved for the mutual use and accommodation of all public utilities using or desiring to use same. All, and any public utility shall have the right to remove and keep removed all or parts of any building, fences, trees, shrubs, or other improvements or growths which in any way may endanger or interfere with the construction, maintenance or efficiency of its respective system on the easements, and all public utilities shall at all times have the full right of ingress and egress to or from the said easements for the purpose of constructing, reconstructing, inspecting, patrolling, maintaining and adding to or removing all or parts of its respective systems without the necessity at any time of procuring the permission of anyone. (Any public utility shall have the right of ingress and egress to private property for the purpose of reading meters and any maintenance or service required or ordinarily performed by that utility). Water main and wastewater easements shall also include additional area of working space for construction and maintenance of the systems. Additional easement area is also conveyed for installation and maintenance of manholes, cleanouts, fire hydrants, water services and wastewater services from the main to the curb or pavement line, and description of such additional easements herein granted shall be determined by their location as installed. This plat approved subject to all platting ordinances, rules, regulations, and resolutions of the City of Coppell. WITNESS, my hand at Coppell, Texas, this the ____ day of _____, 20__. By: _____________________________________ Name: _______________, _____________ STATE OF __________ § COUNTY OF ________§ BEFORE ME, the undersigned authority, on this day personally appeared, __________________, known to me to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same on behalf of said limited liability companies and limited partnership, for the purposes and consideration therein expressed. GIVEN UNDER MY HAND AND SEAL OF OFFICE this _____________ day of _________________, 2024. _______________________________________ Notary Public in and for the State of _________ PRELIMINARY THIS DOCUMENT SHALL NOT BE RECORDED FOR ANY PURPOSE AND SHALL NOT BE USED OR VIEWED OR RELIED UPON AS A FINAL SURVEY DOCUMENT SURVEYOR: KIMLEY-HORN AND ASSOC., INC. 2500 PACIFIC AVENUE, SUITE 1100 DALLAS, TEXAS 75226 CONTACT: J. ANDY DOBBS, R.P.L.S. PHONE: 972-770-1300 EMAIL:ANDY.DOBBS@KIMLEY-HORN.COM OWNER: SL7 DFW INDUSTRIAL, LP 100 CRESCENT COURT, SUITE 850, DALLAS, TEXAS 75201 CONTACT: BLAKE WILSON PHONE: 214-220-7297 ENGINEER: KIMLEY-HORN AND ASSOC., INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 CONTACT: NEDA HOSSEINY, P.E. PHONE: 972-770-1300 EMAIL: NEDA.HOSSEINY@KIMLEY-HORN.COM REPLAT STONELAKE SKYPORT ADDITION LOT 1, BLOCK A, BEING A REPLAT OF PARK 'N FLY ADDITION S.A. & M.G. RAILROAD SURVEY, ABSTRACT NO. 1439 16.0714 ACRES DATE OF PREPARATION: 9/11/24 CITY OF COPPELL, DALLAS COUNTY, TEXAS I, J. Andy Dobbs, a Registered Professional Land Surveyor, verify that all franchise utilities have each been contacted and provided a copy of the plat and development proposal and all franchise utility easements and/or abandonments are currently shown. The undersigned, the Planning and Zoning Commission Secretary of the City of Coppell, Texas, hereby certifies that the foregoing plat of STONELAKE SKYPORT ADDITION, LOT 1, BLOCK A, an addition to the City of Coppell was submitted to the Planning and Zoning Commission on the ______ day of ______, 20___, and the Planning and Zoning Commission, by formal action, then and there accepted the dedication of streets, alleys, parks, easements, public places, and water and sewer lines, as shown and set forth in and upon said plat, and said Chairman to note the acceptance thereof by signing his name as hereinabove subscribed. Witness my hand this ____ day of ______, 20___. __________________________________ _____________ Planning & Zoning Commission Secretary, Date City of Coppell, Texas Approved and Accepted: _________________________________ ______________ Chairman, Planning and Zoning Commission Date City of Coppell, Texas 13 ITEM 5 Page 1 of 3 CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT Stonelake Skyport Lot 1, Block A, Site Plan P&Z HEARING DATE: September 19, 2024 STAFF REP.: Matthew Steer, AICP, Development Services Administrator LOCATION: Northeast corner of South Royal Lane and Gateway Boulevard SIZE OF AREA: 16.07 acres of property CURRENT ZONING: LI (Light Industrial) REQUEST: Site plan approval for two office/warehouse buildings APPLICANT: Developer: Engineer: SL & DFW Industrial, LP Neda Hossieny, P.E. 100 Crescent Court, Suite 850 Kimley-Horn & Associates Dallas, TX 75201 13455 Noel Road, Two Galleria Office Tower, Ste. 700 Bwilson@stonelake.com Dallas, TX 75240 Neda.Hossieny@Kimley-Horn.com HISTORY: This property is zoned Light Industrial (LI) and has been used as a Park’n Fly location since 1995. A Site Plan for a similar Office/Warehouse Development was approved in October 2022 for redevelopment of this site but was never constructed. The corresponding proposed plat was also never filed of record. TRANSPORTATION: South Royal Lane is a four-lane divided thoroughfare built within a 110-foot right-of-way. South of the property Gateway Boulevard is a two-lane undivided thoroughfare built within a 70-foot right-of-way at this segment. SURROUNDING LAND USE & ZONING: North – DART Rail Line & Light Industrial (LI) South – LBJ Freeway East - Office Warehouse; Light Industrial (LI) West – Vacant Land (LI) COMPREHENSIVE PLAN: Coppell 2030, A Comprehensive Master Plan, indicates this property as Freeway Special District. 15 ITEM 5 Page 2 of 3 DISCUSSION: Site Plan The site is currently being used as a Park’n Fly location and has several buildings in addition to car canopy areas that will be removed to allow for this new construction. The site is zoned Light Industrial (LI) and is surrounded by other LI properties. It is bounded by Royal Lane to the west, Gateway Boulevard to the south, DART rail line to the north and another office-warehouse site to the east. Two office warehouse buildings are proposed to be constructed on this site, side by side, with the truck courts facing one another. There is an entrance proposed on Gateway Boulevard which will bring trucks straight into the truck court area. There is also another entrance located on Royal Lane. Building 1 which is closest to Royal Lane is proposed to be 117,608-square feet, while Building 2 which is located on the eastern portion of the site is proposed to be 164,904-square feet. There are 33,000 square feet devoted to office space and the remainder will be warehouse/distribution space. A parking ratio of 1 parking space per 300 square feet is attributed to the office space and one parking space per 1,000 square feet is attributed to the warehouse space. There are 361 parking spaces proposed for cars in addition to truck dock space. A fire lane encircles the site and bisects the truck court area. In addition, a 30-foot drive aisle extends north and south, parallel to Royal for truck traffic. The applicant is proposing a 65-foot-wide drive approach with an 8-foot X 18- foot concrete median separating the inbound and outbound traffic on Royal to help maneuver the trucks to and from the site. This requires a variance to our Subdivision Ordinance, as the width exceeds the 40’ maximum and the radii are irregular. This is listed as a condition within the recommendation for approval. Landscape Plan/Tree Survey There are only 5 trees to be preserved on site. The remainder (783 caliper inches) will be removed. There are 6 specimen trees greater than 24 caliper inches that will be removed. After a preservation credit and landscaping credit, the total cost is $179,870.00, to be paid at the time of tree removal permit. As designed, the Landscape Plan is compliant with the regulations of the Landscape Ordinance and exceeds the amount to total landscape area. The landscape buffer along Royal Lane, along the DART perimeter to the north and segments of Gateway Boulevard meet or exceed the 15-foot minimum required. A total of 130, 4-caliper inch overstory trees are proposed to be planted on site. These consist of 39 Lacey Oak, 22 Chinquapin Oak, 30 Shumard Red Oak, 13 Live Oak, and 26 Cedar Elms. The proposed and existing perimeter trees and proposed shrubs will serve to buffer the DART line from the site. There are shrubs proposed to screen the parking areas from the rights-of-ways and the adjacent properties. Building Elevations, Lighting & Signage The buildings are approximately 48-ft in height with the parapet. The buildings will be made of tilt wall and will have enhanced entries at the ends and in the middle. There are square clerestory windows on the upper part of the front elevations to provide natural light. The corners of the buildings 16 ITEM 5 Page 3 of 3 have extensive storefront glass with a canopies and reveals. The truck court side of the buildings will also have reveals to break up the length. There are two monument signs proposed: one on Gateway Boulevard and one on Royal Lane. The details have not been provided. They will be required to meet the signage requirements of the Zoning Ordinance. Building signage has not been identified and also will need to meet ordinance requirements. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff is recommending APPROVAL of the Stonelake Skyport Site Plan, subject to the following conditions: 1. A variance be granted to allow for the driveway configuration as shown for the South Royal Lane entry. 2. There may be additional comments at the time of Detail Engineering Review and Building Permit. 3. Signage shall comply with the sign ordinance. 4. A tree removal permit shall be required. Tree mitigation fees are estimated to be $179,870.00. 5. The plat for this development be filed. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: 1. Recommend approval of the request 2. Recommend disapproval of the request 3. Recommend modification of the request 4. Take under advisement for reconsideration at a later date ATTACHMENTS: 1. Site Plan 2. Tree Preservation Plan 3. Landscape Plan 4. Buildings 1 & 2 Elevations 5. Trip Generation Memo 17 T3PT3PS S D D R1 0 ' R 10' R 10'9' 9' 9' 9' 9' 9' 9' 9' 9' 9' 9' 9'R10'R30' EXISTING MEDIAN OPENING PROPOSED BUILDING 1 (117,608 SF) BLDG. HEIGHT: 48'-0" 800 S ROYAL LANE ZONING: LI PROPOSED BUILDING 2 (164,904 SF) BLDG. HEIGHT: 48'-0" 800 S ROYAL LANE ZONING: LI EXISTING MEDIAN OPENING LOADING RAMP LOADING RAMP 9' 9' 9' LOADING RAMP LOADING RAMP R 3 0 'R 1 0 'R40' N85°31'02"E 841.31' N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' N70° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'S0°03'01"E1068.65'LOT 1R-2, BLOCK 2 GATEWAY BUSINESS PARK PARK REPLAT INST.NO.201700235650 LANTHIAN COPPELL TX LLC INST.NO.202300259370 ZONING: LI ST. LOUIS & SOUTHWE S T E R N R A I L R O A D VOLUME 95, PAGE 518 (100' right-of-way) INT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y )S. ROYAL LANE(variable width right-of-way)9'R30'R1 0' R 1 0 'R20 'PROP. 3" BACK FLOW PREVENTER PROP. BFR PROP. BFR PROP. BFR PROP. BFR PROP. BFR PROP. BFR PROP. BFR PROP. SSMH PROP. BFR PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. 24' FIRE LANE EASEMENT PROP. BFR PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. BFR PROP. BFR PROP. BACK FLOW PREVENTER PROP. BACK FLOW PREVENTER EX. MEDIAN EX. MEDIAN EX. MEDIAN EX. MEDIAN EX. CURB PROP. SIDEWALK EX. CURB (TYP.) EX. CURB (TYP.) PROP. BFR PROP. BFR PROP. BFR PROP. BFR PROP. FH PROP. FDC PROP. FDC PROP. SSMH PROP. MONUMENT SIGN PROP. MONUMENT SIGN PROP. CLEANOUT PROP. 60' BUILDING SETABACK PROP. 60' BUILDING SETABACK PROP. 60' BUILDING SETABACK 9' 9' PROP. 60' BUILDING SETBACK 10' BUILDING SETBACK VOL.95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' BUILDING SETBACK VOL.95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 60' BUILDING SETBACK 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' BUILDING SETBACK VOL.95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANSCAPE EASEMENT VOL. 95127, PG. 4328 20' UTILITY EASEMENT VOL. 95127, PG. 4328 10' BUILDING SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 ±418.9' ±4 9 9 . 8 'NOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKING11 8 145 15 10 1114 9 8 9 15 12 15 15 15 14 14 1411 11 14 1111 7 8 8712 878 10 FLFLFLFLFLFLFLFLFLFL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL18.0'18.0' 18.0'18.0'18.0'18.0'18.0'18.0'18.0'18.0' 18.0'18.0' 18.0' 18.0'18.0'18.0'18.0'18.0'18.0'18.0'18.0' 18.0' 18.0'24.0'88.0' 200.0' 24.0'88.0' 200.0' 8.0'40.0'380.0'763.8'18.0'18.0'18.0' 18.0'45.0'45.0'18.0' 18.0'18.0' 18.0'9.0'9.0'9.0' 9.0' 9.0'9.0' 9.0'9.0'9.0'9.0'24.0'FIRE LANE24.0' FIRELANE 5.0' 10.0'10.0'88.0' 88.0'7.0'6.0' 6.0' 6.0' 10.0' 10.0' 9.0' 9.0' 9.0' 18.0' 18.0'3.0' (TYP.)30.0' 30.0' 200.0'220.0' 30.0'9.0'9.0'6.0'18.0' 10.0' 5.0' 10.0'5.0'25.0'25.0' 23.0'5.0'79.1'6.0'71.3'PROP. 15' WATER EASEMENT PROP. 24' FIRE LANE EASEMENT PROP. VARIABLE WIDTH FIRE LANE EASEMENT PROP. 24' FIRE LANE EASEMENT PROP. 24' FIRE LANE EASEMENT PROP. 30' FIRE LANE EASEMENT PROP. 24' FIRE LANE EASEMENT PROP. 24' FIRE LANE EASEMENT 15' LANSCAPE EASEMENT VOL. 95127, PG. 4328 20' UTILITY EASEMENT VOL. 95127, PG. 4328 PROP. RETAINING WALL PROP. RETAINING WALL PROP. RETAINING WALL PROP. 3P TRANSFORMER PROP. 3P TRANSFORMER 30.0'72.0'32.0'72.0'5.0'9'9.0'9.0'9.0'9.0'9.0'9.0'9.0'9.0'18.0'9.0'R30' 12' SCREENING WALL 12' SCREENING WALL 12' SCREENING WALL 12' SCREENING WALL ANTICIPATED PUMP ROOM LOCATION ANTICIPATED PUMP ROOM LOCATION PROP. TRASH COMPACTOR PROP. TRASH COMPACTOR PROP. 15' WATER EASEMENT 40.0'R100'R100'R100'R100'R100'R100'R100'R100'R60'R80'R60'R80'PROP. 3" WATER METER PROP. 30' WATER EASEMENT PROP. BFRR10'R30'R100'R 3 0 'R 1 0'R30' R 3 0 'R100'R100'R54'R30 'R54'R30'R 3 0 ' R 5 4 ' R 30'R 5 4 'PROP. IRRIGATION METER R2' R2' PROP. 18'x8' CONCRETE MEDIAN PROP. 10' SIDEWALK EASEMENT PROP. 10' SIDEWALK EASEMENT 56.0' 10.0'22.0'S. ROYAL LANEINT E R S T A T E H I G H W A Y 6 3 5 GA T E W A Y B O U L E V A R D ST. LOUIS & SOUTHWESTERN RAILROAD SITE BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643NMHGCPAKAAUGUST 2024Engineer P.E. No. Date FOR REVIEW ONLY NOT FOR CONSTRUCTION OR PERMIT PURPOSES. NEDA M. HOSSEINY 126707 08/19/2024 STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASPRELIMINARY SITEPLAN1 OF 1 NORTH 1.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION FOR NORTH CENTRAL TEXAS, LATEST EDITION, AND THE CITY OF COPPELL STANDARD CONSTRUCTION DETAILS. 2.DURING THE CONSTRUCTION OF THESE IMPROVEMENTS, ANY INTERPRETATION OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION FOR NORTH CENTRAL TEXAS, AND ANY MATTER WHICH REQUIRES THE APPROVAL OF THE OWNER, MUST BE APPROVED BY THE DIRECTOR OF ENGINEERING OR HIS DESIGNEE BEFORE ANY CONSTRUCTION INVOLVING THAT DECISION COMMENCES. ASSUMPTIONS ABOUT WHAT THESE DECISIONS MIGHT BE WHICH ARE MADE DURING THE BIDDING PHASE WILL HAVE NO BEARING ON THE DECISION. 3.ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 4.ALL CURBS ARE 6" IN HEIGHT UNLESS OTHERWISE NOTED. 5.NO OUTSIDE STORAGE IS PROPOSED. NOTESLEGEND FIRE HYDRANT FIRE LANEFL PROPERTY LINE ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY, FLOOD INSURANCE RATE MAP COMMUNITY PANEL NO. 48113C0135K, DATED JULY 7, 2014, THIS PROPERTY IS WITHIN FLOOD ZONE X. ZONE X - AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. THE FLOOD STATEMENT DOES NOT IMPLY THAT THE PROPERTY AND/OR THE STRUCTURE THEREON WILL BE FREE FROM FLOODING OR FLOOD DAMAGE. ON RARE OCCASIONS, GREATER FLOODS CAN AND WILL OCCUR AND FLOOD HEIGHTS MAY BE INCREASED BY MAN-MADE OR NATURAL CAUSES. THIS FLOOD STATEMENT SHALL NOT CREATE LIABILITY ON THE PART OF THE SURVEYOR. FLOOD NOTE BFR (BARRIER FREE RAMP) CITY OF COPPELL FIRE LANE SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 A VARIANCE IS BEING REQUESTED TO ALLOW FOR THE DRIVEWAY CONFIGURATION AS SHOWN FOR THE S. ROYAL ENTRY. 18 SS SS SS SS SS SS SS SS SS S S S S S S S S S SSSSSSSS WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WW SS SS SS SS SS SS SS SS SS S S S S S S S S S SSSSSSSS WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWW WWWWWWWWWW W W W W W WW W T3PT3PW W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWW W W W SSWWWWWWW WWWWWWWWWWWWWWWWWWWWWS S SS SS SSSSSSSSSSSSSSSSW W WWWWWWWWWWWWWWWWWWWWW W W W W W WW W T3PT3PW W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWW W W W SSWWWWWWW WWWWWWWWWWWWWWWWWWWWWS S SS SS SSSSSSSSSSSSSSSSW W D D D D 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 20' UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE EASEMENT VOL. 95127, PG. 4328 N85°31'02"E 841.31' N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' N70 ° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'60' SETBACK VOL. 95127, PG. 4328 S0°03'01"E1068.65'PARK 'N FLY ADDITION VOL. 95127, PG. 4328 16.071 ACRES (700,072 SQ. FT.) PNF-DALLAS, LLC INST. NO. 201500267352 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 20' UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE EASEMENT VOL. 95127, PG. 4328 N85°31'02"E 841.31' N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' N70 ° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'60' SETBACK VOL. 95127, PG. 4328 S0°03'01"E1068.65'PARK 'N FLY ADDITION VOL. 95127, PG. 4328 16.071 ACRES (700,072 SQ. FT.) PNF-DALLAS, LLC INST. NO. 201500267352NOPARKING NOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGFLFLFLFLFLFLFLFLFLFL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGFLFLFLFLFLFLFLFLFLFL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL8001 8002 8003 8004 8005 8006 8007 8008 8009 801080118012 8014 80158016 8017 8018 8019 8020 802180228023 8024 8025 8026 8027 8028 8029 8030 8031 8032 8033 8034 8035 8036 8037 8038 8039 8040 8041 8042 8043 8044 8045 8046 8047 8048 8049 80508051 8052 8053 8054 8055 8056 8057TPTPTPTPTPTPTPTPTPTPINT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y ) ST. LOUIS & SOUTHWE S T E R N R A I L R O A D VOLUME 95, PAGE 518 (100' right-of-way)S. ROYAL LANE(variable width right-of-way)S. ROYAL LANE(variable width right-of-way)INT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y )S. ROYAL LANEINT E R S T A T E H I G H W A Y 6 3 5 GA T E W A Y B O U L E V A R D SITE ST. LOUIS & SOUTHWESTERN RAILROAD BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK 1 TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK 1GATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.OVERALL TREEPRESERVATION PLANTP 0.00 NORTH TP 1.00 TP 1.02 TP 1.01 TP 1.03 TP 1.04 EXISTING TREE TO BE REMOVED LEGEND TREE PROTECTION FENCINGTP EXISTING TREE TO REMAIN NOTE: TREES TO BE CLASSIFIED PER ARTICLE 34 - DIVISION 2 19 SSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW W W W W T3PWSS SS SS SS W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WW W W W W T3PWSS SS SS SS W W W W W W W W W 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 NOPARKINGNOPARKINGFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FL FL NOPARKINGNOPARKINGFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FL FL 8006 8007 8008 8009 8010 8011 8012 8014 8015 8016 8017 8018 8019 8020 8021 8022 8023 8024 8025 8026 8027 8028 8029 8030 8031 8032 8033 8034 8035 8036 TP TPTPTPTP TPTPTPTP TP TPTPTPPROPOSED TREE PROTECTION FENCE, REF. DETAIL D, SHEET LP 2.00, TYP. EXISTING TREE TO BE REMOVED, TYP. EXISTING TREE TO REMAIN, TYP. EXISTING TREE TO REMAIN, TYP. PROPERTY LINE, TYP. PROPERTY LINE, TYP. EXISTING TREE TO BE REMOVED, TYP. PROPOSED CONCRETE SIDEWALK, REF. CIVIL PLANS, TYP. EXISTING TREE TO BE REMOVED, TYP. PROPOSED MONUMENT SIGN, REF. ARCH EXISTING STORM LINE, TYP. PROPOSED STORM LINE, REF. CIVIL PLANS BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK 1 TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK 1GATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.MATCH LINE SHEET TP 1.02MATCH LINE SHEET TP 1.01 TREE PRESERVATIONPLANTP 1.00 NORTH EXISTING TREE TO BE REMOVED LEGEND TREE PROTECTION FENCINGTP EXISTING TREE TO REMAIN NOTE: TREES TO BE CLASSIFIED PER ARTICLE 34 - DIVISION 2 20 SS SS SS SS SS SS SS SS SS SS SS WWWWWWWWWWWWWWWWWWWWWWWWSS SS SS SS SS SS SS SS SS SS SS WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWWWW W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWWWW 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 N70° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'60' SETBACK VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 N70° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'60' SETBACK VOL. 95127, PG. 4328 NOPARKINGFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLNOPARKINGFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL8001 8002 8003 8004 8005 8047 8048 8049 8050 8051 8052 8053 PROPERTY LINE, TYP. PROPERTY LINE, TYP. EXISTING TREE TO BE REMOVED, TYP. EXISTING TREE TO BE REMOVED, TYP. PROPOSED COMMERCIAL PARKING, REF. CIVIL PLANS PROPOSED CONCRETE SIDEWALK, REF. CIVIL PLANS, TYP. PROPOSED CONCRETE SIDEWALK, REF. CIVIL PLANS, TYP. EXISTING TREE TO BE REMOVED, TYP. INT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y )BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK 1 TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK 1GATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.MATCH LINE SHEET TP 1.03MATCH LINE SHEET TP 1.00 TREE PRESERVATIONPLANTP 1.01 NORTH EXISTING TREE TO BE REMOVED LEGEND TREE PROTECTION FENCINGTP EXISTING TREE TO REMAIN NOTE: TREES TO BE CLASSIFIED PER ARTICLE 34 - DIVISION 2 21 WWWWWWWWWWWWWWWWWWWWWWWWWWW W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWSS WWWW W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWSS W10' SETBACK VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 N85°31'02"E 841.31'S0°03'01"E1068.65'PARK 'N FLY ADDITION VOL. 95127, PG. 4328 16.071 ACRES (700,072 SQ. FT.) 10' SETBACK VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 N85°31'02"E 841.31'S0°03'01"E1068.65'PARK 'N FLY ADDITION VOL. 95127, PG. 4328 16.071 ACRES (700,072 SQ. FT.)NOPARKINGNOPARKINGFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLNOPARKINGNOPARKINGFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL8037 8038 8039 8040 8041 8042 8043 8044 TP TPTPTPTPTP TP TPTPTPTPEXISTING TREE TO BE REMAIN, TYP. PROPERTY LINE, TYP. PROPERTY LINE, TYP. EXISTING TREE TO BE REMOVED, TYP. PROPOSED TREE PROTECTION FENCE, REF. DETAIL D, SHEET LP 2.00, TYP. PROPOSED RETAINING WALL, REF. ARCH PLANS PROPOSED CONCRETE SIDEWALK, REF. CIVIL PLANS, TYP. PROPOSED CONCRETE SIDEWALK, REF. CIVIL PLANS, TYP. ST. LOUIS & SOUTHWE S T E R N R A I L R O A D VOLUME 95, PAGE 518 (100' right-of-way) PROPOSED STORM LINE, REF. CIVIL PLANS BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK 1 TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK 1GATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.MATCH LINE SHEET TP 1.00MATCH LINE SHEET TP 1.03 TREE PRESERVATIONPLANTP 1.02 NORTH EXISTING TREE TO BE REMOVED LEGEND TREE PROTECTION FENCINGTP EXISTING TREE TO REMAIN NOTE: TREES TO BE CLASSIFIED PER ARTICLE 34 - DIVISION 2 22 SS SS SS SSWW WWWWWWSS SS SS SSWW WWWWWWT3PW W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWW W W W W W W W W W W W SS SS SS SSWW WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWS SSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSST3PW W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWW W W W W W W W W W W W SS SS SS SSWW WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWS SSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSDD PNF-DALLAS, LLC INST. NO. 201500267352 PNF-DALLAS, LLC INST. NO. 201500267352 NOPARKINGNOPARKINGFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLNOPARKINGNOPARKINGFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL8046 PROPERTY LINE, TYP. PROPOSED RETAINING WALL, REF. ARCH PLANS PROPOSED RETAINING WALL, REF. ARCH PLANS PROPOSED CONCRETE SIDEWALK, REF. CIVIL PLANS, TYP. PROPOSED MONUMENT SIGN, REF. ARCH EXISTING TREE TO BE REMOVED, TYP.BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK 1 TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK 1GATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes. MATCH LINE SHEET TP 1.02 MATCH LINE SHEET TP 1.01MATCH LINE SHEET TP 1.04 TREE PRESERVATIONPLANTP 1.03 NORTH EXISTING TREE TO BE REMOVED LEGEND TREE PROTECTION FENCINGTP EXISTING TREE TO REMAIN NOTE: TREES TO BE CLASSIFIED PER ARTICLE 34 - DIVISION 2 23 SS SS SS SS SS SS SS SS SS S S S S S S S S S S S S S S S S S S S S S S S S WWWWWWWWWWWWWWWWWWWWWWWWWSS SS SS SS SS SS SS SS SS S S S S S S S S S S S S S S S S S S S S S S S S WWWWWWWWWWWWWWWWWWWWWWWWWW W W W W W W W W W W WWWWW W W W W W W W W W W WWWWDD 20' UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE EASEMENT VOL. 95127, PG. 4328 N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' 20' UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE EASEMENT VOL. 95127, PG. 4328 N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 'FLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FLFL8054 8055 8056 8057 PROPERTY LINE, TYP. PROPERTY LINE, TYP. INT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y ) PROPOSED RETAINING WALL, REF. ARCH PLANS EXISTING TREE TO REMAIN, TYP. EXISTING WATER LINE REMAIN, TYP.BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK 1 TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK 1GATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes. MATCH LINE SHEET TP 1.03 TREE PRESERVATIONPLANTP 1.04 NORTH EXISTING TREE TO BE REMOVED LEGEND TREE PROTECTION FENCINGTP EXISTING TREE TO REMAIN NOTE: TREES TO BE CLASSIFIED PER ARTICLE 34 - DIVISION 2 24 BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK 1 TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK 1GATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.TREE INVENTORYTP 1.05 NOTE: THE FOLLOWING TREE HEALTH DESCRIPTIONS ARE BASED ON A RAPID VISUAL ASSESSMENT OF INDICATORS WHICH ARE EASILY IDENTIFIABLE FROM GROUND LEVEL AND WITH THE UNAIDED EYE. FOR TREE INVENTORY PURPOSES ONLY. HEALTHY: TREE SHOW SIGNS OF GROWTH. INDICATORS OF DISEASE OR DIEBACK NOT OBSERVED. DECLINING: TREE SHOWS VISIBLE SIGNS OF DISEASE (SUCH AS FUNGUS, SLIME FLUX, OR BARK SLOUGHING) OR DIEBACK. HAZARD: TREE SHOWS VISIBLE SIGNS OF DECAY, LIMB FAILURE AND/OR INSTABILITY. TREE INVENTORY CONDUCTED BY AND/OR UNDER THE SUPERVISION OF: Alex Brown ISA Certified Arborist TX-4383A Kimley-Horn and Associates NOTE: TREES TO BE CLASSIFIED PER ARTICLE 34 - DIVISION 2 PER SECTION 12-34-2-6 EXEMPTIONS. TREES LOCATED WITHIN THE BUILDING FOOTPRINT IS TO BE EXEMPT AND NOT CONSIDERED PROTECTED AND NOT SUBJECT TO TREE REPARATION PAYMENT DIA = DEVELOPMENT IMPACT AREA DEVELOPMENT IMPACT AREA IS ANY AREA BEING IMPACTED BY GRADING DISTURBANCE. 25 SS SS SS SS SS SS SS SS SS S S S S S S S S S SSSSSSSS WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WW W W NOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGFLFLFLFLFLFLFLFLFLFL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\\\\\\\\\\\\\\\\\8026 8030 8031 8038 8041 8053 8054 8055 8056 8057WWWWWWWWWWWWWWWWWWWWWWWWWWWWWT3PT3PW W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWW W W W SSWWWWWWW WWWWWWWWWWWWWWWWWWWWWS S SS SS SSSSSSSSSSSSSSSSW W D D 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 20' UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE EASEMENT VOL. 95127, PG. 4328 N85°31'02"E 841.31' N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' N70° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'60' SETBACK VOL. 95127, PG. 4328 S0°03'01"E1068.65'PARK 'N FLY ADDITION VOL. 95127, PG. 4328 16.071 ACRES (700,072 SQ. FT.) PNF-DALLAS, LLC INST. NO. 201500267352 SS SS SS SS SS SS SS SS SS S S S S S S S S S SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWWWWWWWWW WW W WW WWWWWWWWWWWWWWWW 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 20' UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE EASEMENT VOL. 95127, PG. 4328 N85°31'02"E 841.31' N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' N70° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'60' SETBACK VOL. 95127, PG. 4328 S0°03'01"E1068.65'PARK 'N FLY ADDITION VOL. 95127, PG. 4328 16.071 ACRES (700,072 SQ. FT.) PNF-DALLAS, LLC INST. NO. 201500267352 INT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y ) ST. LOUIS & SOUTHWE S T E R N R A I L R O A D VOLUME 95, PAGE 518 (100' right-of-way)S. ROYAL LANE(variable width right-of-way)S. ROYAL LANE(variable width right-of-way)INT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y ) SYMBOL CODE QTY SIZE CALIPER BOTANICAL / COMMON NAME REMARKS TREES CC 39 B & B 4" CAL.QUERCUS LACEYI / LACEY OAK SINGLE STRAIGHT CENTRAL LEADER, FULL AND MATCHING QM 22 B & B 4" CAL.QUERCUS MUHLENBERGII / CHINQUAPIN OAK SINGLE STRAIGHT CENTRAL LEADER, FULL AND MATCHING QS 30 B & B 4" CAL.QUERCUS SHUMARDII / SHUMARD RED OAK SINGLE STRAIGHT CENTRAL LEADER, FULL AND MATCHING QV 13 B & B 4" CAL.QUERCUS VIRGINIANA / LIVE OAK SINGLE STRAIGHT CENTRAL LEADER, FULL AND MATCHING UC 26 B & B 4" CAL.ULMUS CRASSIFOLIA / CEDAR ELM SINGLE STRAIGHT CENTRAL LEADER, FULL AND MATCHING SYMBOL CODE QTY SIZE SPACING BOTANICAL / COMMON NAME REMARKS SHRUBS IC 913 CONT.24" HT.ILEX CORNUTA `DWARF BURFORD` / DWARF BURFORD HOLLY FULL AND MATCHING AGGREGATE RR 201 SF N/A N/A RIVER ROCK / RIVER ROCK 3"-5" COBBLE SIZE, LOCALLY SOURCED. TURF/GRASSES SOD 80,448 SF N/A N/A CYNODON DACTYLON X TRANSVAALENSIS 'DT-1' / TIF TUF BERMUDAGRASS SOD TO BE LOCALLY SOURCED PLANT SCHEDULE BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.OVERALLLANDSCAPE PLANLP 0.00 NORTH 1.CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATIONS OF ALL UNDERGROUND UTILITIES, PIPES, STRUCTURES, AND LINE RUNS IN THE FIELD PRIOR TO THE INSTALLATION OF ANY PLANT MATERIAL. 2.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ADVISE THE LANDSCAPE ARCHITECT OF ANY CONDITION FOUND ON SITE WHICH PERMITS INSTALLATION AS SHOWN ON THESE DRAWINGS. 3.ALL PLANT MATERIAL SHALL BE MAINTAINED IN A HEALTHY, GROWING CONDITION AND MUST BE REPLACED WITHIN 30 DAYS WITH PLANT MATERIAL OF THE SAME VARIETY AND SIZE IF DAMAGED, DESTROYED, OR REMOVED. 4.CONTRACTOR SHALL BE RESPONSIBLE FOR FINE GRADING AND REMOVAL OF DEBRIS PRIOR TO PLANTING IN ALL AREAS. 5.FINAL FINISH GRADING SHALL BE REVIEWED AND APPROVED BY THE LANDSCAPE ARCHITECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL TOPSOIL REQUIRED TO CREATE A SMOOTH CONDITION PRIOR TO PLANTING. 6.CONTRACTOR SHALL VERIFY ALL PLANT QUANTITIES. ALL PLANT QUANTITIES ARE LISTED FOR INFORMATION PURPOSES ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE FULL COVERAGE IN ALL PLANTING AREAS AS SHOWN ON THE PLANS AND SPECIFIED IN THE PLANT SCHEDULE. 7.CONTRACTOR TO PROVIDE STEEL EDGING BETWEEN ALL PLANTING BEDS AND TURF AREAS UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 8.ALL PLANT MATERIAL SHALL CONFORM TO THE SPECIFICATIONS GIVEN IN THE PLANT SCHEDULE, PLANTING DETAILS, AND PLANTING SPECIFICATIONS. 9.ALL PLANT MATERIAL SHALL MEET INDUSTRY STANDARDS AS INDICATED IN THE CURRENT EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.1). 10. ALL PLANT MATERIAL SUBSTITUTIONS SHALL BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO PURCHASE. 11. CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION WITH OTHER CONTRACTORS ON SITE AS REQUIRED TO ACCOMPLISH ALL PLANTING OPERATIONS. 12. ALL PLANTING AREAS SHALL RECEIVE SOIL AMENDMENTS. 13. PLANT MATERIAL SHALL BE PRUNED PER PLANTING DETAILS UNLESS OTHERWISE NOTED ON DRAWINGS. 14. PLANTING AREAS SHALL BE KEPT FREE OF TRASH, WEEDS, DEBRIS, AND DEAD PLANT MATERIAL. 15. ALL LIME STABILIZED SOIL AND INORGANIC SELECT FILL FOR BUILDING OR PAVING CONSTRUCTION SHALL BE REMOVED FROM ALL PLANTING BEDS TO A MINIMUM DEPTH OF 24” UNLESS OTHERWISE NOTED. REPLACE MATERIAL REMOVED WITH IMPORTED TOPSOIL. 16. TREES OVERHANGING PEDESTRIAN WALKS AND WITHIN VISIBILITY TRIANGLES AS NOTED ON THE PLANS SHALL BE LIMBED TO A HEIGHT OF SEVEN FEET (7'). TREE OVERHANGING PUBLIC STREETS AND FIRELANES SHALL BE LIMBED TO A HEIGHT OF FOURTEEN FEET (14'). 17. TREES PLANTED NEXT TO ACCESSIBLE ROUTES AND ACCESSIBLE AREAS SHALL BE LIMBED TO 7'6” (80” MIN.) AFF. 18. ALL PROPOSED TREES SHALL BE STAKED WITH AN AT-GRADE ROOT BALL SECURING SYSTEM AS SHOWN IN THE PLANTING DETAILS AND SPECIFICATIONS. NO ABOVE-GROUND STAKING SYSTEMS, GUY WIRES/WIRES, HOSES, STRAPS, POSTS (METAL OR WOOD) SHALL BE ALLOWED UNLESS AUTHORIZED IN WRITING BY THE LANDSCAPE ARCHITECT. PLANTING NOTES: ALL PROPOSED LANDSCAPE IMPROVEMENTS SHALL BE PROVIDED A PERMANENT IRRIGATION SYSTEM PER CITY OF COPPELL CODE OF ORDINANCES. LP 1.00 LP 1.02 LP 1.01 LP 1.03 LP 1.04 26 SS SS SS SS SS SS SS SS SS S S S S S S S S S SSSSSSSS WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WW W W NOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGFLFLFLFLFLFLFLFLFLFL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\\\\\\\\\\\\\\\\\8026 8030 8031 8038 8041 8053 8054 8055 8056 8057WWWWWWWWWWWWWWWWWWWWWWWWWWWWWT3PT3PW W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWW W W W SSWWWWWWW WWWWWWWWWWWWWWWWWWWWWS S SS SS SSSSSSSSSSSSSSSSW W D D 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 20' UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE EASEMENT VOL. 95127, PG. 4328 N85°31'02"E 841.31' N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' N70° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'60' SETBACK VOL. 95127, PG. 4328 S0°03'01"E1068.65'PARK 'N FLY ADDITION VOL. 95127, PG. 4328 16.071 ACRES (700,072 SQ. FT.) PNF-DALLAS, LLC INST. NO. 201500267352 SS SS SS SS SS SS SS SS SS S S S S S S S S S SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWWWWWWWWW WW W WW WWWWWWWWWWWWWWWW 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 20' UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE EASEMENT VOL. 95127, PG. 4328 N85°31'02"E 841.31' N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' N70° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'60' SETBACK VOL. 95127, PG. 4328 S0°03'01"E1068.65'PARK 'N FLY ADDITION VOL. 95127, PG. 4328 16.071 ACRES (700,072 SQ. FT.) PNF-DALLAS, LLC INST. NO. 201500267352 INT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y ) ST. LOUIS & SOUTHWE S T E R N R A I L R O A D VOLUME 95, PAGE 518 (100' right-of-way)S. ROYAL LANE(variable width right-of-way)S. ROYAL LANE(variable width right-of-way)INT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y )BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.LANDSCAPE PLAN -DETAILLP 0.01 NORTH LP 1.00 LP 1.02 LP 1.01 LP 1.03 LP 1.04 27 SSSSSSSSNOPARKINGNOPARKINGFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FL FL \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ 8026 8030 8031 WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW W W W W T3PWSS SS SS SS W W W W W W W W W 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS WWWWWWWWW W W W 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 SOD ADA PARKING, TYP. REF. CIVIL PLANS CONCRETE SIDEWALK, TYP. REF. CIVIL PLANS CONCRETE SIDEWALK, TYP. REF. CIVIL PLANS EXISTING TREE TO REMAIN, TYP. EXISTING TREE TO REMAIN, TYP. PROPERTY LINE, TYP. PROPOSED MONUMENT SIGN, REF. ARCHS. ROYAL LANE(variable width right-of-way)MULCH UNDER EXISTING TREES, TYP. MULCH UNDER EXISTING TREES, TYP. AGGREGATE, TYP., REF. DETAIL E, SHEET LP 2.00 15' PERIMETER BUFFER, TYP. STEEL EDGING, TYP., REF. DETAIL C, SHEET LP 2.00 15' PERIMETER BUFFER, TYP. EXISTING STORM TO REMAIN, TYP. REF. CIVIL PLANS CONCRETE SIDEWALK, TYP. REF. CIVIL PLANS CONCRETE, TYP. REF. CIVIL PLANS CONCRETE, TYP. REF. CIVIL PLANS SYMBOL CODE BOTANICAL / COMMON NAME TREES CC QUERCUS LACEYI / LACEY OAK QM QUERCUS MUHLENBERGII / CHINQUAPIN OAK QS QUERCUS SHUMARDII / SHUMARD RED OAK QV QUERCUS VIRGINIANA / LIVE OAK UC ULMUS CRASSIFOLIA / CEDAR ELM SHRUBS IC ILEX CORNUTA `DWARF BURFORD` / DWARF BURFORD HOLLY AGGREGATE RR RIVER ROCK / RIVER ROCK TURF/GRASSES SOD CYNODON DACTYLON X TRANSVAALENSIS 'DT-1' / TIF TUF BERMUDAGRASS PLANT SCHEDULE BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.MATCH LINE SHEET LP 1.02MATCH LINE SHEET LP 1.01 LANDSCAPE PLANLP 1.00 NORTH REF. SHEET LP 0.00 FOR COMPLETE PLANT SCHEDULE 28 SS SS SS SS SS SS SS SS SS SS SS WWWWWWWWWWWWWWWWWWWWWWWWNOPARKINGFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \ \ \ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ 8053 WWWWWWWWWWWWWWW W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWWWW 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 N70° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'60' SETBACK VOL. 95127, PG. 4328 SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS WWWWWWWWWWWWWWWWWWWWWWWWW 10' SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 N70° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'60' SETBACK VOL. 95127, PG. 4328 CONCRETE SIDEWALK, TYP. REF. CIVIL PLANS PROPERTY LINE, TYP. PROPERTY LINE, TYP. INT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y )S. ROYAL LANE(variable width right-of-way)STEEL EDGING, TYP., REF. DETAIL C, SHEET LP 2.00 15.0' 15' PERIMETER BUFFER, TYP. SYMBOL CODE BOTANICAL / COMMON NAME TREES CC QUERCUS LACEYI / LACEY OAK QM QUERCUS MUHLENBERGII / CHINQUAPIN OAK QS QUERCUS SHUMARDII / SHUMARD RED OAK QV QUERCUS VIRGINIANA / LIVE OAK UC ULMUS CRASSIFOLIA / CEDAR ELM SHRUBS IC ILEX CORNUTA `DWARF BURFORD` / DWARF BURFORD HOLLY AGGREGATE RR RIVER ROCK / RIVER ROCK TURF/GRASSES SOD CYNODON DACTYLON X TRANSVAALENSIS 'DT-1' / TIF TUF BERMUDAGRASS PLANT SCHEDULE BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.MATCH LINE SHEET LP 1.03MATCH LINE SHEET LP 1.00 LANDSCAPE PLANLP 1.01 NORTH REF. SHEET LP 0.00 FOR COMPLETE PLANT SCHEDULE 29 WWWWWWWWWWWWNOPARKINGNOPARKINGFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ 8038 8041 WWW W W W W W W W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWSS W10' SETBACK VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 N85°31'02"E 841.31'S0°03'01"E1068.65'PARK 'N FLY ADDITION VOL. 95127, PG. 4328 16.071 ACRES (700,072 SQ. FT.)WWWWWWWWWWWWWWWWWWWWWW10' SETBACK VOL. 95127, PG. 4328 10' SETBACK VOL. 95127, PG. 4328 N85°31'02"E 841.31'S0°03'01"E1068.65'PARK 'N FLY ADDITION VOL. 95127, PG. 4328 16.071 ACRES (700,072 SQ. FT.) ADA PARKING, TYP. REF. CIVIL PLANS SOD CONCRETE SIDEWALK, TYP. REF. CIVIL PLANS CONCRETE SIDEWALK, TYP. REF. CIVIL PLANS EXISTING TREE TO REMAIN, TYP. EXISTING TREE TO REMAIN, TYP. PROPERTY LINE, TYP. PROPOSED RETAINING WALL, REF. ARCH PLANS ST. LOUIS & SOUTHWE S T E R N R A I L R O A D VOLUME 95, PAGE 518 (100' right-of-way)MULCH UNDER EXISTING TREES, TYP. MULCH, TYP. MULCH, TYP. 15' PERIMETER BUFFER, TYP. MULCH UNDER EXISTING TREES, TYP. MULCH, TYP. MULCH, TYP. SYMBOL CODE BOTANICAL / COMMON NAME TREES CC QUERCUS LACEYI / LACEY OAK QM QUERCUS MUHLENBERGII / CHINQUAPIN OAK QS QUERCUS SHUMARDII / SHUMARD RED OAK QV QUERCUS VIRGINIANA / LIVE OAK UC ULMUS CRASSIFOLIA / CEDAR ELM SHRUBS IC ILEX CORNUTA `DWARF BURFORD` / DWARF BURFORD HOLLY AGGREGATE RR RIVER ROCK / RIVER ROCK TURF/GRASSES SOD CYNODON DACTYLON X TRANSVAALENSIS 'DT-1' / TIF TUF BERMUDAGRASS PLANT SCHEDULE BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.MATCH LINE SHEET LP 1.00MATCH LINE SHEET LP 1.03 LANSCAPE PLANLP 1.02 NORTH REF. SHEET LP 0.00 FOR COMPLETE PLANT SCHEDULE 30 SS SS SS SSWW WWWWWWNOPARKINGNOPARKINGFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL\\ \\ \\ \\ \\ \\ \\T3PW W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWW W W W W W W W W W W W SS SS SS SSWW WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWS SSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSD PNF-DALLAS, LLC INST. NO. 201500267352 SS SS SS SSWW WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWPNF-DALLAS, LLC INST. NO. 201500267352 SOD SOD ADA PARKING, TYP. REF. CIVIL PLANS CONCRETE SIDEWALK, TYP. REF. CIVIL PLANS CONCRETE SIDEWALK, TYP. REF. CIVIL PLANS PROPERTY LINE, TYP. PROPOSED RETAINING WALL, REF. ARCH PLANS PROPOSED MONUMENT SIGN, REF. ARCH MULCH, TYP. AGGREGATE, TYP., REF. DETAIL E, SHEET LP 2.00 MULCH, TYP. MULCH, TYP. MULCH, TYP. MULCH, TYP. STEEL EDGING, TYP., REF. DETAIL C, SHEET LP 2.00 CONCRETE, TYP. REF. CIVIL PLANS SYMBOL CODE BOTANICAL / COMMON NAME TREES CC QUERCUS LACEYI / LACEY OAK QM QUERCUS MUHLENBERGII / CHINQUAPIN OAK QS QUERCUS SHUMARDII / SHUMARD RED OAK QV QUERCUS VIRGINIANA / LIVE OAK UC ULMUS CRASSIFOLIA / CEDAR ELM SHRUBS IC ILEX CORNUTA `DWARF BURFORD` / DWARF BURFORD HOLLY AGGREGATE RR RIVER ROCK / RIVER ROCK TURF/GRASSES SOD CYNODON DACTYLON X TRANSVAALENSIS 'DT-1' / TIF TUF BERMUDAGRASS PLANT SCHEDULE BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes. MATCH LINE SHEET LP 1.02 MATCH LINE SHEET LP 1.01MATCH LINE SHEET LP 1.04 LANDSCAPE PLANLP 1.03 NORTH REF. SHEET LP 0.00 FOR COMPLETE PLANT SCHEDULE 31 SS SS SS SS SS SS SS SS SS S S S S S S S S S S S S S S S S S S S S S S S S WWWWWWWWWWWWWWWWWWWWWWWWWFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FLFL\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\8054 8055 8056 8057 W W W W W W W W W WWWWWD 20' UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE EASEMENT VOL. 95127, PG. 4328 N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' SS SS SS SS SS SS SS SS SS S S S S S S S S S S S S S S S S S S S S S S S S WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW20' UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE EASEMENT VOL. 95127, PG. 4328 N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' SOD EXISTING TREE TO REMAIN, TYP. CONCRETE SIDEWALK, TYP. REF. CIVIL PLANS PROPERTY LINE, TYP. PROPERTY LINE, TYP. PROPOSED RETAINING WALL, REF. ARCH PLANS INT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y ) STEEL EDGING, TYP., REF. DETAIL C, SHEET LP 2.00 MULCH UNDER EXISTING TREES, TYP. MULCH, TYP. MULCH, TYP. SYMBOL CODE BOTANICAL / COMMON NAME TREES CC QUERCUS LACEYI / LACEY OAK QM QUERCUS MUHLENBERGII / CHINQUAPIN OAK QS QUERCUS SHUMARDII / SHUMARD RED OAK QV QUERCUS VIRGINIANA / LIVE OAK UC ULMUS CRASSIFOLIA / CEDAR ELM SHRUBS IC ILEX CORNUTA `DWARF BURFORD` / DWARF BURFORD HOLLY AGGREGATE RR RIVER ROCK / RIVER ROCK TURF/GRASSES SOD CYNODON DACTYLON X TRANSVAALENSIS 'DT-1' / TIF TUF BERMUDAGRASS PLANT SCHEDULE BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes. MATCH LINE SHEET LP 1.03 LANDSCAPE PLANLP 1.04 NORTH REF. SHEET LP 0.00 FOR COMPLETE PLANT SCHEDULE 32 PLAN ARBOR STAKE TYP., INSTALL 4" MIN. FROM EDGE OF ROOTBALL. ROOTBALL TREE TRUNK TREE CANOPY 6"3 X ROOTBALL WIDTH 4" MULCH LAYER. PLACE NO MORE THAN 1" OF MULCH ON TOP OF ROOTBALL (REF. PLANTING SPECIFICATIONS FOR MULCH TYPE) 4" HIGH x 8" WIDE BERM SHALL BE CONSTRUCTED AROUND THE ROOTBALL. BERM SHALL BEGIN AT ROOTBALL PERIPHERY, FIRMLY COMPACTED. 6" DIA. CLEAR OF MULCH AT ROOT FLARE. IF REQUIRED, REMOVE EXCESS SOIL ON TOP OF ROOTBALL (MAX 2") AND EXPOSE TREE ROOT FLARE. ORIGINAL GRADE. SCARIFY BOTTOM AND LOOSEN SIDES OF PLANTING PIT NATIVE LOOSENED PLANTING SOIL BACKFILL. DIG AND TURN THE SOIL TO REDUCE COMPACTION TO THE AREA AND DEPTH SHOWN. LIGHTLY TAMP SOIL AROUND ROOTBALL IN 6" LIFTS TO BRACE TREE. DO NOT OVER COMPACT. IN THE TOP 1/3 DEPTH OF BACK FILL, MIX 1/2" LAYER OF COMPOST INTO EACH 6" LIFT OF BACKFILL. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND ROOTBALL TO SETTLE THE SOIL. ADD ADDITIONAL SOIL AS NEEDED TO MEET REQUIRED FINISH GRADE. TRUNK/ROOTBALL TO BE CENTERED AND PLUMB/LEVEL IN PLANTING PIT UNDISTURBED NATIVE SOIL MINIMUM SECTION FINISHED GRADE.4"NOTES: 1.REF. PLANTING AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. 2.PERFORM PERCOLATION TEST PER PLANTING SPECIFICATIONS. IF SUBSURFACE DRAINAGE PROBLEMS ARE ENCOUNTERED, NOTIFY PROJECT LANDSCAPE ARCHITECT. 8' DIA. MULCH RING (MIN.) FOR INDIVIDUAL TREES NOT IN LANDSCAPE BEDS TYPICAL TREE PLANTING AScale: NTS 6"8" SET ROOTBALL ON UNDISTURBED STABLE SUBSOIL SO THAT TOP OF ROOTBALL IS 2-3" ABOVE FINISHED GRADE. STABILIZE/PLUMB TREE BY TAMPING SOIL FIRMLY AROUND THE LOWER 1/4 OF THE ROOTBALL. ·FOR CONTAINER STOCK: REMOVE ENTIRE CONTAINER. ·FOR B&B STOCK: COMPLETELY REMOVE TOP 1/2 OF THE ENTIRE WIRE BASKET. COMPLETELY REMOVE ALL BURLAP/SYNTHETIC FABRICS AND STRAPPING. 3 X ROOTBALL WIDTH 2-3" MULCH LAYER (REF. PLANTING SPECIFICATIONS) 4" HIGH x 8" WIDE BERM SHALL BE CONSTRUCTED AROUND THE ROOT BALL. BERM SHALL BEGIN AT ROOT BALL PERIPHERY, FIRMLY COMPACTED. FINISHED GRADE. UNDISTURBED NATIVE SOIL SCARIFY BOTTOM AND SIDES OF PLANTING PIT SET ROOTBALL ON UNDISTURBED STABLE SUBSOIL LOOSENED SOIL. DIG AND TURN THE SOIL TO REDUCE THE COMPACTION TO THE AREA AND DEPTH SHOWN. LIGHTLY TAMP SOIL AROUND ROOTBALL IN 6" LIFTS TO BRACE SHRUB. DO NOT OVER COMPACT. WHEN PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND ROOTBALL TO SETTLE THE SOIL. ADD ADDITIONAL SOIL AS NEEDED TO MEET REQUIRED FINISH GRADE. PLANT ROOTBALL TO BE INSTALLED CENTERED AND PLUMB/LEVEL IN PLANTING PIT NOTES: 1.REF. PLANTING SPECIFICATIONS FOR ADDITIONAL INFORMATION. 2.WHEN SHRUBS MASSED TOGETHER WITH GROUNDCOVER BEDS, ALL SOIL IN BED TO BE AMENDED. (REF. PLANTING SPECIFICATIONS) 3.WHEN SHRUBS ARE USED IN MASSES, PRUNE ALL SHRUBS TO ACHIEVE UNIFORM MASS/HEIGHT. 4.REF. TO PLANT SCHEDULE AND PLANTING PLANS FOR SPACING/LAYOUT. SECTION BEST FACE OF SHRUB TO FACE FRONT OF PLANTING BED PLAN 4"FRONT OF BED EQ. EQ. SHRUBS TO BE TRIANGULARLY SPACED UNLESS SHOWN DIFFERENTLY ON PLANTING PLANS. SHRUB TYPICAL SHRUB PLANTING BScale: NTS LEAVE 6" OF TOP OF ROOTBALL EXPOSED AROUND BASE OF STEMS.1"CScale: 1 1/2" = 1'-0" STEEL EDGING (AT TURF & LANDSCAPE BED) MULCH LAYER REF. PLANTING PLANS AND SPECIFICATIONS AMENDED PLANTING SOIL, REF. PLANTING SOIL PLANS AND PLANTING SPECIFICATIONS STEEL EDGING STAKES REF. PLANTING SPECIFICATIONS STEEL EDGING, REF. PLANTING SPECIFICATIONS UNDISTURBED NATIVE SOIL TURF (SOD)LANDSCAPE BED TOPSOIL, REF. PLANTING SOIL PLAN AND PLANTING SPECIFICATIONS TYPICAL TREE PROTECTION FENCING DScale: NTS CROWN DRIP LINE OR OTHER LIMIT OF TREE AND PLANT PROTECTION AREA SEE TREE PROTECTION PLAN FOR FENCE LAYOUT MAINTAIN EXISTING GRADE WITHIN THE TREE PROTECTION FENCE UNLESS OTHERWISE INDICATED ON THE PLANS TREE PROTECTION FENCE AND POSTS (REF. TREE AND PLANT PROTECTION SPECIFICATIONS). SIGNIFICANT TREES (AS NOTED ON PLANS) TO HAVE CHAIN LINK FENCE PROTECTION. 6" - 12" THICK LAYER OF MULCH FOR TREES CLOSE TO CONSTRUCTION ACTIVITIES ONLY. DO NOT MULCH AREA WITHIN 6" TO 12" OF TREE TRUNK, DO NOT COVER VISIBLY LARGE WOODY ABOVE-GRADE STRUCTURAL ROOTS (REF. TREE AND PLANT PROTECTION SPECIFICATIONS) TREE PROTECTION SIGN SPACED EVERY 50' O.C. MINIMUM ALONG THE FENCE (REF. ENLARGEMENT) ROOT PRUNING TRENCH, OPTIONAL, AS REQUIRED BY FIELD CONDITIONS AND AS DIRECTED BY PROJECT ARBORIST. (TYP., REF. TREE AND PLANT PROTECTION SPECIFICATIONS) 8'-0" (TYP.) 6" (TYP.) TRUNK PROTECTION OPTIONAL, AS REQUIRED BY FIELD CONDITIONS AND AS DIRECTED BY PROJECT ARBORIST. REF. DETAIL B THIS SHEET NOTES: 1.SEE SPECIFICATIONS FOR WATERING AND OTHER ADDITIONAL REQUIREMENTS. 2.ALL TREE AND ROOT PRUNING SHALL BE PERFORMED UNDER THE SUPERVISION OF AN I.S.A. CERTIFIED ARBORIST. ARBORIST SHALL MAKE ALL FINAL ROOT PRUNING RECOMMENDATIONS TO OWNER'S REPRESENTATIVE FOR APPROVAL PRIOR TO PRUNING OPERATIONS. 3.NO EQUIPMENT SHALL OPERATE INSIDE THE TREE PROTECTION FENCE INCLUDING DURING FENCE INSTALLATION AND REMOVAL. 4.TREE PROTECTION FENCE LAYOUT AND INSTALLATION TO BE APPROVED BY OWNER'S REPRESENTATIVE PRIOR TO ANY CONSTRUCTION ACTIVITY. KEEP OUT TREE PROTECTION AREA NO ENTRY PROJECT ARBORIST PHONE # GENERAL CONTRACTOR PHONE # ·NO HEAVY EQUIPMENT ·NO PARKING ·NO STORAGE ·NO DUMPING ·NO GRADING24"36" TREE PROTECTION SIGN ENLARGEMENT ZONA DE PROTECCION PARA ARBOLES NO ENTRE ·NO EQUIPAMIENTO PESADO ·NO ESTACIONAR ·NO ALMACENAJE ·PROHIBIDO TRIAR BASURA ·NO EXCAVAR ARBORISTA DEL PROYECTO TELEFONO # CONTRATISTA GENERAL TELEFONO # NOTE: CONTRACTOR TO PROVIDE PHONE NUMBER INFORMATION 2"FILTER FABRIC. UPTURN 2" AT SIDES AND ENDS AND AHERE TO EDGING W/ CONSTRUCTION ADHESIVE. SECURE FABRIC TO FINISH GRADE W/ FABRIC STAPLES COMPACTED SUB-BASE, REF. GEOTECH REPORT EScale: NTS Aggregate at Concrete and Planting4"PAVING VARIES, REF. PLANS FOR TYPE STAKES PER MANUFACTURER 2"LOCALLY SOURCED DECOMPOSED GRANITE METAL EDGING BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.LANDSCAPE DETAILSLP 2.00 33 BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.LANDSCAPE SPECIFICATIONSLP 2.01 SECTION 329300: PLANTING PART 1 GENERAL 1.1 SUMMARY A.THE SCOPE OF WORK INCLUDES ALL LABOR, MATERIALS, APPLIANCES, TOOLS, EQUIPMENT, FACILITIES, TRANSPORTATION AND SERVICES NECESSARY FOR, AND INCIDENTAL TO PERFORMING ALL OPERATIONS IN CONNECTION WITH FURNISHING, DELIVERY, AND INSTALLATION OF PLANT (ALSO KNOWN AS "LANDSCAPING”) COMPLETE AS SHOWN ON THE DRAWINGS AND AS SPECIFIED HEREIN. B.THE SCOPE OF WORK IN THIS SECTION INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: 1.LOCATE, PURCHASE, DELIVER AND INSTALL ALL SPECIFIED PLANTS. 2.WATER ALL SPECIFIED PLANTS. 3.MULCH, FERTILIZE, STAKE, AND PRUNE ALL SPECIFIED PLANTS. 4.MAINTENANCE OF ALL SPECIFIED PLANTS UNTIL THE BEGINNING OF THE WARRANTY PERIOD. 5.PLANT WARRANTY. 6.CLEAN UP AND DISPOSAL OF ALL EXCESS AND SURPLUS MATERIAL. 7.MAINTENANCE OF ALL SPECIFIED PLANTS DURING THE WARRANTY PERIOD. 1.2 CONTRACT DOCUMENTS A.SHALL CONSIST OF SPECIFICATIONS AND GENERAL CONDITIONS AND THE CONSTRUCTION DRAWINGS. THE INTENT OF THESE DOCUMENTS IS TO INCLUDE ALL LABOR, MATERIALS, AND SERVICES NECESSARY FOR THE PROPER EXECUTION OF THE WORK. THE DOCUMENTS ARE TO BE CONSIDERED AS ONE. WHATEVER IS CALLED FOR BY ANY PARTS SHALL BE AS BINDING AS IF CALLED FOR IN ALL PARTS. 1.3 RELATED DOCUMENTS AND REFERENCES A.RELATED DOCUMENTS: 1.DRAWINGS AND GENERAL PROVISIONS OF CONTRACT INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION I SPECIFICATIONS APPLY TO WORK OF THIS SECTION 2.RELATED SPECIFICATION SECTIONS a.IRRIGATION b.LAWN AND GRASSES B.REFERENCES: THE FOLLOWING SPECIFICATIONS AND STANDARDS OF THE ORGANIZATIONS AND DOCUMENTS LISTED IN THIS PARAGRAPH FORM A PART OF THE SPECIFICATION TO THE EXTENT REQUIRED BY THE REFERENCES THERETO. IN THE EVENT THAT THE REQUIREMENTS OF THE FOLLOWING REFERENCED STANDARDS AND SPECIFICATION CONFLICT WITH THIS SPECIFICATION SECTION THE REQUIREMENTS OF THIS SPECIFICATION SHALL PREVAIL. IN THE EVENT THAT THE REQUIREMENTS OF ANY OF THE FOLLOWING REFERENCED STANDARDS AND SPECIFICATIONS CONFLICT WITH EACH OTHER THE MORE STRINGENT REQUIREMENT SHALL PREVAIL OR AS DETERMINED BY THE OWNERS REPRESENTATIVE. 1.ANSI Z60.1 AMERICAN STANDARD FOR NURSERY STOCK, MOST CURRENT EDITION. 2.ANSI A 300 - STANDARD PRACTICES FOR TREE, SHRUB AND OTHER WOODY PLANT MAINTENANCE, MOST CURRENT EDITION AND ALL PARTS. 3.INTERPRETATION OF PLANT NAMES AND DESCRIPTIONS SHALL REFERENCE THE FOLLOWING DOCUMENTS. WHERE THE NAMES OR PLANT DESCRIPTIONS DISAGREE BETWEEN THE SEVERAL DOCUMENTS, THE MOST CURRENT DOCUMENT SHALL PREVAIL. a.USDA - THE GERMPLASM RESOURCES INFORMATION NETWORK (WWW.ARS-GRIN.GOV/NPGS.HTML) b.MANUAL OF WOODY LANDSCAPE PLANTS; MICHAEL DIRR; STIPES PUBLISHING, CHAMPAIGN, ILLINOIS; MOST CURRENT EDITION. c.THE NEW SUNSET WESTERN GARDEN BOOK, OXMOOR HOUSE, MOST CURRENT EDITION. 4.PRUNING PRACTICES SHALL CONFORM TO RECOMMENDATIONS “STRUCTURAL PRUNING: A GUIDE FOR THE GREEN INDUSTRY” MOST CURRENT EDITION; PUBLISHED BY URBAN TREE FOUNDATION, VISALIA, CALIFORNIA. 5.GLOSSARY OF ARBORICULTURAL TERMS, INTERNATIONAL SOCIETY OF ARBORICULTURE, CHAMPAIGN IL, MOST CURRENT EDITION. 1.4 VERIFICATION A.ALL SCALED DIMENSIONS ON THE DRAWINGS ARE APPROXIMATE. BEFORE PROCEEDING WITH ANY WORK, THE CONTRACTOR SHALL CAREFULLY CHECK AND VERIFY ALL DIMENSIONS AND QUANTITIES, AND SHALL IMMEDIATELY INFORM THE OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES BETWEEN THE INFORMATION ON THE DRAWINGS AND THE ACTUAL CONDITIONS, REFRAINING FROM DOING ANY WORK IN SAID AREAS UNTIL GIVEN APPROVAL TO DO SO BY THE OWNER'S REPRESENTATIVE. B.IN THE CASE OF A DISCREPANCY IN THE PLANT QUANTITIES BETWEEN THE PLAN DRAWINGS AND THE PLANT CALL OUTS, LIST OR PLANT SCHEDULE, THE NUMBER OF PLANTS OR SQUARE FOOTAGE OF THE PLANTING BED ACTUALLY DRAWN ON THE PLAN DRAWINGS SHALL BE DEEMED CORRECT AND PREVAIL. 1.5 PERMITS AND REGULATIONS A.THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS RELATED TO THIS SECTION OF THE WORK UNLESS PREVIOUSLY EXCLUDED UNDER PROVISION OF THE CONTRACT OR GENERAL CONDITIONS. THE CONTRACTOR SHALL COMPLY WITH ALL LAWS AND ORDINANCES BEARING ON THE OPERATION OR CONDUCT OF THE WORK AS DRAWN AND SPECIFIED. IF THE CONTRACTOR OBSERVES THAT A CONFLICT EXISTS BETWEEN PERMIT REQUIREMENTS AND THE WORK OUTLINED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL PROMPTLY NOTIFY THE OWNER'S REPRESENTATIVE IN WRITING INCLUDING A DESCRIPTION OF ANY NECESSARY CHANGES AND CHANGES TO THE CONTRACT PRICE RESULTING FROM CHANGES IN THE WORK. B.WHEREVER REFERENCES ARE MADE TO STANDARDS OR CODES IN ACCORDANCE WITH WHICH WORK IS TO BE PERFORMED OR TESTED, THE EDITION OR REVISION OF THE STANDARDS AND CODES CURRENT ON THE EFFECTIVE DATE OF THIS CONTRACT SHALL APPLY, UNLESS OTHERWISE EXPRESSLY SET FORTH. C.IN CASE OF CONFLICT AMONG ANY REFERENCED STANDARDS OR CODES OR BETWEEN ANY REFERENCED STANDARDS AND CODES AND THE SPECIFICATIONS, THE MORE RESTRICTIVE STANDARD SHALL APPLY OR OWNER'S REPRESENTATIVE SHALL DETERMINE WHICH SHALL GOVERN. 1.6 PROTECTION OF WORK, PROPERTY AND PERSON A.THE CONTRACTOR SHALL ADEQUATELY PROTECT THE WORK, ADJACENT PROPERTY, AND THE PUBLIC, AND SHALL BE RESPONSIBLE FOR ANY DAMAGES OR INJURY DUE TO HIS/HER ACTIONS. 1.7 CHANGES IN THE WORK A.THE OWNER'S REPRESENTATIVE MAY ORDER CHANGES IN THE WORK, AND THE CONTRACT SUM SHOULD BE ADJUSTED ACCORDINGLY. ALL SUCH ORDERS AND ADJUSTMENTS PLUS CLAIMS BY THE CONTRACTOR FOR EXTRA COMPENSATION MUST BE MADE AND APPROVED IN WRITING BEFORE EXECUTING THE WORK INVOLVED. B.ALL CHANGES IN THE WORK, NOTIFICATIONS AND CONTRACTOR'S REQUEST FOR INFORMATION (RFI) SHALL CONFORM TO THE CONTRACT GENERAL CONDITION REQUIREMENTS. 1.8 CORRECTION OF WORK A.THE CONTRACTOR, AT THEIR OWN COST, SHALL RE-EXECUTE ANY WORK THAT FAILS TO CONFORM TO THE REQUIREMENTS OF THE CONTRACT AND SHALL REMEDY DEFECTS DUE TO FAULTY MATERIALS OR WORKMANSHIP UPON WRITTEN NOTICE FROM THE OWNER'S REPRESENTATIVE, AT THE SOONEST AS POSSIBLE TIME THAT CAN BE COORDINATED WITH OTHER WORK AND SEASONAL WEATHER DEMANDS. 1.9 DEFINITIONS ALL TERMS IN THIS SPECIFICATION SHALL BE AS DEFINED IN THE “GLOSSARY OF ARBORICULTURAL TERMS” OR AS MODIFIED BELOW. A.BOXED TREES: A CONTAINER ROOT BALL PACKAGE MADE OF WOOD IN THE SHAPE OF A FOUR-SIDED BOX. B.CONTAINER PLANT: PLANTS THAT ARE GROWN IN AND/OR ARE CURRENTLY IN A CONTAINER INCLUDING BOXED TREES. C.DEFECTIVE PLANT: ANY PLANT THAT FAILS TO MEET THE PLANT QUALITY REQUIREMENT OF THIS SPECIFICATION. D.END OF WARRANTY FINAL ACCEPTANCE: THE DATE WHEN THE OWNER'S REPRESENTATIVE ACCEPTS THAT THE PLANTS AND WORK IN THIS SECTION MEET ALL THE REQUIREMENTS OF THE WARRANTY. IT IS INTENDED THAT THE MATERIALS AND WORKMANSHIP WARRANTY FOR PLANTING, PLANTING SOIL, AND IRRIGATION WORK RUN CONCURRENT WITH EACH OTHER. E.FIELD GROWN TREES (B&B): TREES GROWING IN FIELD SOIL FOR AT LEAST 12 MONTHS PRIOR TO HARVEST. F.HEALTHY: PLANTS THAT ARE GROWING IN A CONDITION THAT EXPRESSES LEAF SIZE, CROWN DENSITY, COLOR; AND WITH ANNUAL GROWTH RATES TYPICAL OF THE SPECIES AND CULTIVAR'S HORTICULTURAL DESCRIPTION, ADJUSTED FOR THE PLANTING SITE SOIL, DRAINAGE AND WEATHER CONDITIONS. G.KINKED ROOT: A ROOT WITHIN THE ROOT PACKAGE THAT BENDS MORE THAN 90 DEGREES. H.MAINTENANCE: ACTIONS THAT PRESERVE THE HEALTH OF PLANTS AFTER INSTALLATION AND AS DEFINED IN THIS SPECIFICATION. I.MAINTENANCE PERIOD: THE TIME PERIOD, AS DEFINED IN THIS SPECIFICATION, WHICH THE CONTRACTOR IS TO PROVIDE MAINTENANCE. J.NORMAL: THE PREVAILING PROTOCOL OF INDUSTRY STANDARD(S). K.OWNER'S REPRESENTATIVE: THE PERSON APPOINTED BY THE OWNER TO REPRESENT THEIR INTEREST IN THE REVIEW AND APPROVAL OF THE WORK AND TO SERVE AS THE CONTRACTING AUTHORITY WITH THE CONTRACTOR. THE OWNER'S REPRESENTATIVE MAY APPOINT OTHER PERSONS TO REVIEW AND APPROVE ANY ASPECTS OF THE WORK. L.REASONABLE AND REASONABLY: WHEN USED IN THIS SPECIFICATION RELATIVE TO PLANT QUALITY, IT IS INTENDED TO MEAN THAT THE CONDITIONS CITED WILL NOT AFFECT THE ESTABLISHMENT OR LONG TERM STABILITY, HEALTH OR GROWTH OF THE PLANT. THIS SPECIFICATION RECOGNIZES THAT IT IS NOT POSSIBLE TO PRODUCE PLANTS FREE OF ALL DEFECTS, BUT THAT SOME ACCEPTED INDUSTRY PROTOCOLS AND STANDARDS RESULT IN PLANTS UNACCEPTABLE TO THIS PROJECT. WHEN REASONABLE OR REASONABLY IS USED IN RELATION TO OTHER ISSUES SUCH AS WEEDS, DISEASED, INSECTS, IT SHALL MEAN AT LEVELS LOW ENOUGH THAT NO TREATMENT WOULD BE REQUIRED WHEN APPLYING RECOGNIZED INTEGRATED PLANT MANAGEMENT PRACTICES. THIS SPECIFICATION RECOGNIZES THAT SOME DECISIONS CANNOT BE TOTALLY BASED ON MEASURED FINDINGS AND THAT PROFESSIONAL JUDGMENT IS REQUIRED. IN CASES OF DIFFERING OPINION, THE OWNER'S REPRESENTATIVE'S EXPERT SHALL DETERMINE WHEN CONDITIONS ARE JUDGED AS REASONABLE. M.ROOT BALL: THE MASS OF ROOTS INCLUDING ANY SOIL OR SUBSTRATE THAT IS SHIPPED WITH THE TREE WITHIN THE ROOT BALL PACKAGE. N.ROOT BALL PACKAGE. THE MATERIAL THAT SURROUNDS THE ROOT BALL DURING SHIPPING. THE ROOT PACKAGE MAY INCLUDE THE MATERIAL IN WHICH THE PLANT WAS GROWN, OR NEW PACKAGING PLACED AROUND THE ROOT BALL FOR SHIPPING. O.ROOT COLLAR (ROOT CROWN, ROOT FLARE, TRUNK FLARE, FLARE): THE REGION AT THE BASE OF THE TRUNK WHERE THE MAJORITY OF THE STRUCTURAL ROOTS JOIN THE PLANT STEM, USUALLY AT OR NEAR GROUND LEVEL. P.SHRUB: WOODY PLANTS WITH MATURE HEIGHT APPROXIMATELY LESS THAN 15 FEET. Q.SPADE HARVESTED AND TRANSPLANTED: FIELD GROWN TREES THAT ARE MECHANICALLY HARVESTED AND IMMEDIATELY TRANSPLANTED TO THE FINAL GROWING SITE WITHOUT BEING REMOVED FROM THE DIGGING MACHINE. R.STEM: THE TRUNK OF THE TREE. S.SUBSTANTIAL COMPLETION ACCEPTANCE: THE DATE AT THE END OF THE PLANTING, PLANTING SOIL, AND IRRIGATION INSTALLATION WHERE THE OWNER'S REPRESENTATIVE ACCEPTS THAT ALL WORK IN THESE SECTIONS IS COMPLETE AND THE WARRANTY PERIOD HAS BEGUN. THIS DATE MAY BE DIFFERENT THAN THE DATE OF SUBSTANTIAL COMPLETION FOR THE OTHER SECTIONS OF THE PROJECT. T.STEM GIRDLING ROOT: ANY ROOT MORE THAN ¼ INCH DIAMETER CURRENTLY TOUCHING THE TRUNK, OR WITH THE POTENTIAL TO TOUCH THE TRUNK, ABOVE THE ROOT COLLAR APPROXIMATELY TANGENT TO THE TRUNK CIRCUMFERENCE OR CIRCLING THE TRUNK. ROOTS SHALL BE CONSIDERED AS STEM GIRDLING THAT HAVE, OR ARE LIKELY TO HAVE IN THE FUTURE, ROOT TO TRUNK BARK CONTACT. U.STRUCTURAL ROOT: ONE OF THE LARGEST ROOTS EMERGING FROM THE ROOT COLLAR. V.TREE: SINGLE AND MULTI-STEMMED PLANTS WITH MATURE HEIGHT APPROXIMATELY GREATER THAN 15 FEET. 1.10 SUBMITTALS A.SEE CONTRACT GENERAL CONDITIONS FOR POLICY AND PROCEDURE RELATED TO SUBMITTALS. B.SUBMIT ALL PRODUCT SUBMITTALS 4 WEEKS PRIOR TO INSTALLATION OF PLANTINGS. C.PRODUCT DATA: SUBMIT MANUFACTURER PRODUCT DATA AND LITERATURE DESCRIBING ALL PRODUCTS REQUIRED BY THIS SECTION TO THE OWNER'S REPRESENTATIVE FOR APPROVAL. PROVIDE SUBMITTAL FOUR WEEKS BEFORE THE INSTALLATION OF PLANTS. D.SAMPLES: SUBMIT SAMPLES OF EACH PRODUCT AND MATERIAL WHERE REQUIRED BY THE SPECIFICATION TO THE OWNER'S REPRESENTATIVE FOR APPROVAL. LABEL SAMPLES TO INDICATE PRODUCT, CHARACTERISTICS, AND LOCATIONS IN THE WORK. SAMPLES WILL BE REVIEWED FOR APPEARANCE ONLY. COMPLIANCE WITH ALL OTHER REQUIREMENTS IS THE EXCLUSIVE RESPONSIBILITY OF THE CONTRACTOR. E.CLOSE OUT SUBMITTALS: SUBMIT TO THE OWNER'S REPRESENTATIVE FOR APPROVAL. 1.PLANT MAINTENANCE DATA AND REQUIREMENTS. F.WARRANTY PERIOD SITE VISIT RECORD: IF THERE IS NO MAINTENANCE DURING THE WARRANTY PERIOD, AFTER EACH SITE VISIT DURING THE WARRANTY PERIOD, BY THE CONTRACTOR, AS REQUIRED BY THIS SPECIFICATION, SUBMIT A WRITTEN RECORD OF THE VISIT, INCLUDING ANY PROBLEMS, POTENTIAL PROBLEMS, AND ANY RECOMMENDED CORRECTIVE ACTION TO THE OWNER'S REPRESENTATIVE FOR APPROVAL. 1.11 OBSERVATION OF THE WORK A.THE OWNER'S REPRESENTATIVE MAY OBSERVE THE WORK AT ANY TIME. THEY MAY REMOVE SAMPLES OF MATERIALS FOR CONFORMITY TO SPECIFICATIONS. REJECTED MATERIALS SHALL BE IMMEDIATELY REMOVED FROM THE SITE AND REPLACED AT THE CONTRACTOR'S EXPENSE. THE COST OF TESTING MATERIALS NOT MEETING SPECIFICATIONS SHALL BE PAID BY THE CONTRACTOR. B.THE OWNER'S REPRESENTATIVE SHALL BE INFORMED OF THE PROGRESS OF THE WORK SO THE WORK MAY BE OBSERVED AT THE FOLLOWING KEY TIMES IN THE CONSTRUCTION PROCESS. THE OWNER'S REPRESENTATIVE SHALL BE AFFORDED SUFFICIENT TIME TO SCHEDULE VISIT TO THE SITE. FAILURE OF THE OWNER'S REPRESENTATIVE TO MAKE FIELD OBSERVATIONS SHALL NOT RELIEVE THE CONTRACTOR FROM MEETING ALL THE REQUIREMENTS OF THIS SPECIFICATION. 1.SITE CONDITIONS PRIOR TO THE START OF PLANTING: REVIEW THE SOIL AND DRAINAGE CONDITIONS. 2.COMPLETION OF THE PLANT LAYOUT STAKING: REVIEW OF THE PLANT LAYOUT. 3.PLANT QUALITY: REVIEW OF PLANT QUALITY AT THE TIME OF DELIVERY AND PRIOR TO INSTALLATION. REVIEW TREE QUALITY PRIOR TO UNLOADING WHERE POSSIBLE, BUT IN ALL CASES PRIOR TO PLANTING. 4.COMPLETION OF THE PLANTING: REVIEW THE COMPLETED PLANTING. 1.12 PRE-CONSTRUCTION CONFERENCE A.SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE OWNER'S REPRESENTATIVE AT LEAST SEVEN (7) DAYS BEFORE BEGINNING WORK TO REVIEW ANY QUESTIONS THE CONTRACTOR MAY HAVE REGARDING THE WORK, ADMINISTRATIVE PROCEDURES DURING CONSTRUCTION AND PROJECT WORK SCHEDULE. 1.13 QUALITY ASSURANCE A.SUBSTANTIAL COMPLETION ACCEPTANCE - ACCEPTANCE OF THE WORK PRIOR TO THE START OF THE WARRANTY PERIOD: 1.ONCE THE CONTRACTOR COMPLETES THE INSTALLATION OF ALL ITEMS IN THIS SECTION, THE OWNER'S REPRESENTATIVE WILL OBSERVE ALL WORK FOR SUBSTANTIAL COMPLETION ACCEPTANCE UPON WRITTEN REQUEST OF THE CONTRACTOR. THE REQUEST SHALL BE RECEIVED AT LEAST TEN CALENDAR DAYS BEFORE THE ANTICIPATED DATE OF THE OBSERVATION. 2.SUBSTANTIAL COMPLETION ACCEPTANCE BY THE OWNER'S REPRESENTATIVE SHALL BE FOR GENERAL CONFORMANCE TO SPECIFIED SIZE, CHARACTER AND QUALITY AND NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR FULL CONFORMANCE TO THE CONTRACT DOCUMENTS, INCLUDING CORRECT SPECIES. 3.ANY PLANTS THAT ARE DEEMED DEFECTIVE AS DEFINED UNDER THE PROVISIONS BELOW SHALL NOT BE ACCEPTED. B.THE OWNER'S REPRESENTATIVE WILL PROVIDE THE CONTRACTOR WITH WRITTEN ACKNOWLEDGMENT OF THE DATE OF SUBSTANTIAL COMPLETION ACCEPTANCE AND THE BEGINNING OF THE WARRANTY PERIOD AND PLANT MAINTENANCE PERIOD (IF PLANT MAINTENANCE IS INCLUDED). C.CONTRACTOR'S QUALITY ASSURANCE RESPONSIBILITIES: THE CONTRACTOR IS SOLELY RESPONSIBLE FOR QUALITY CONTROL OF THE WORK. D.INSTALLER QUALIFICATIONS: THE INSTALLER SHALL BE A FIRM HAVING AT LEAST 5 YEARS OF SUCCESSFUL EXPERIENCE OF A SCOPE SIMILAR TO THAT REQUIRED FOR THE WORK, INCLUDING THE HANDLING AND PLANTING OF LARGE SPECIMEN TREES IN URBAN AREAS. THE SAME FIRM SHALL INSTALL PLANTING SOIL (WHERE APPLICABLE) AND PLANT MATERIAL. 1.INSTALLER FIELD SUPERVISION: WHEN ANY PLANTING WORK IS IN PROGRESS, INSTALLER SHALL MAINTAIN, ON SITE, A FULL-TIME SUPERVISOR WHO CAN COMMUNICATE IN ENGLISH WITH THE OWNER'S REPRESENTATIVE. 2.INSTALLER'S FIELD SUPERVISOR SHALL HAVE A MINIMUM OF FIVE YEARS EXPERIENCE AS A FIELD SUPERVISOR INSTALLING PLANTS AND TREES OF THE QUALITY AND SCALE OF THE PROPOSED PROJECT, AND WHO CAN COMMUNICATE IN ENGLISH WITH THE OWNER'S REPRESENTATIVE. 3.THE INSTALLER'S CREW SHALL HAVE A MINIMUM OF 3 YEARS EXPERIENCED IN THE INSTALLATION OF PLANTING SOIL, PLANTINGS, AND IRRIGATION (WHERE APPLICABLE) AND INTERPRETATION OF SOIL PLANS, PLANTING PLANS AND IRRIGATION PLANS. 4.SUBMIT REFERENCES OF PAST PROJECTS, EMPLOYEE TRAINING CERTIFICATIONS THAT SUPPORT THAT THE CONTRACTORS MEETS ALL OF THE ABOVE INSTALLER QUALIFICATIONS AND APPLICABLE LICENSURES. 1.14 PLANT WARRANTY A.THE CONTRACTOR AGREES TO REPLACE DEFECTIVE WORK AND DEFECTIVE PLANTS. THE OWNER'S REPRESENTATIVE SHALL MAKE THE FINAL DETERMINATION IF PLANTS MEET THESE SPECIFICATIONS OR THAT PLANTS ARE DEFECTIVE. B.PLANTS WARRANTY SHALL BEGIN ON THE DATE OF SUBSTANTIAL COMPLETION ACCEPTANCE AND CONTINUE FOR THE FOLLOWING PERIODS, CLASSED BY PLANT TYPE: 1.TREES - 1 YEAR. 2.SHRUBS - 1 YEAR. 3.GROUND COVER AND PERENNIAL FLOWER PLANTS - 1 YEAR. 4.BULBS, ANNUAL FLOWER AND SEASONAL COLOR PLANTS - FOR THE PERIOD OF EXPECTED BLOOM OR PRIMARY DISPLAY. C.WHEN THE WORK IS ACCEPTED IN PARTS, THE WARRANTY PERIODS SHALL EXTEND FROM EACH OF THE PARTIAL SUBSTANTIAL COMPLETION ACCEPTANCES TO THE TERMINAL DATE OF THE LAST WARRANTY PERIOD. THUS, ALL WARRANTY PERIODS FOR EACH CLASS OF PLANT WARRANTY, SHALL TERMINATE AT ONE TIME. D.ALL PLANTS SHALL BE WARRANTIED TO MEET ALL THE REQUIREMENTS FOR PLANT QUALITY AT INSTALLATION IN THIS SPECIFICATION. DEFECTIVE PLANTS SHALL BE DEFINED AS PLANTS NOT MEETING THESE REQUIREMENTS. THE OWNER'S REPRESENTATIVE SHALL MAKE THE FINAL DETERMINATION THAT PLANTS ARE DEFECTIVE. E.PLANTS DETERMINED TO BE DEFECTIVE SHALL BE REMOVED IMMEDIATELY UPON NOTIFICATION BY THE OWNER'S REPRESENTATIVE AND REPLACED WITHOUT COST TO THE OWNER, AS SOON AS WEATHER CONDITIONS PERMIT AND WITHIN THE SPECIFIED PLANTING PERIOD. F.ANY WORK REQUIRED BY THIS SPECIFICATION OR THE OWNER'S REPRESENTATIVE DURING THE PROGRESS OF THE WORK, TO CORRECT PLANT DEFECTS INCLUDING THE REMOVAL OF ROOTS OR BRANCHES, TO OBSERVE FOR OR CORRECT ROOT DEFECTS SHALL NOT BE CONSIDERED AS GROUNDS TO VOID ANY CONDITIONS OF THE WARRANTY. IN THE EVENT THAT THE CONTRACTOR DECIDES THAT SUCH REMEDIATION WORK MAY COMPROMISE THE FUTURE HEALTH OF THE PLANT, THE PLANT OR PLANTS IN QUESTION SHALL BE REJECTED AND REPLACED WITH PLANTS THAT DO NOT CONTAIN DEFECTS THAT REQUIRE REMEDIATION OR CORRECTION. G.THE CONTRACTOR IS EXEMPT FROM REPLACING PLANTS, AFTER SUBSTANTIAL COMPLETION ACCEPTANCE AND DURING THE WARRANTY PERIOD, THAT ARE REMOVED BY OTHERS, LOST OR DAMAGED DUE TO OCCUPANCY OF PROJECT, LOST OR DAMAGED BY A THIRD PARTY, VANDALISM, OR ANY NATURAL DISASTER. H.REPLACEMENTS SHALL CLOSELY MATCH ADJACENT SPECIMENS OF THE SAME SPECIES. REPLACEMENTS SHALL BE SUBJECT TO ALL REQUIREMENTS STATED IN THIS SPECIFICATION. MAKE ALL NECESSARY REPAIRS DUE TO PLANT REPLACEMENTS. SUCH REPAIRS SHALL BE DONE AT NO EXTRA COST TO THE OWNER. I.THE WARRANTY OF ALL REPLACEMENT PLANTS SHALL EXTEND FOR AN ADDITIONAL ONE-YEAR PERIOD FROM THE DATE OF THEIR ACCEPTANCE AFTER REPLACEMENT. IN THE EVENT THAT A REPLACEMENT PLANT IS NOT ACCEPTABLE DURING OR AT THE END OF THE SAID EXTENDED WARRANTY PERIOD, THE OWNER'S REPRESENTATIVE MAY ELECT ONE MORE REPLACEMENT ITEMS OR CREDIT FOR EACH ITEM. THESE TERTIARY REPLACEMENT ITEMS ARE NOT PROTECTED UNDER A WARRANTY PERIOD. J.DURING AND BY THE END OF THE WARRANTY PERIOD, REMOVE ALL ABOVE GROUND TREE ASSESSMENTS PRESENT (IE.: TREE WRAP, TIES, AND GUYING) UNLESS AGREED TO BY THE OWNER'S REPRESENTATIVE TO REMAIN IN PLACE. ALL TREES THAT DO NOT HAVE SUFFICIENT CALIPER TO REMAIN UPRIGHT, OR THOSE REQUIRING ADDITIONAL ANCHORAGE IN WINDY LOCATIONS, SHALL BE STAKED OR REMAIN STAKED, IF REQUIRED BY THE OWNER'S REPRESENTATIVE. K.END OF WARRANTY FINAL ACCEPTANCE - ACCEPTANCE OF PLANTS AT THE END OF THE WARRANTY PERIOD. 1.AT THE END OF THE WARRANTY PERIOD, THE OWNER'S REPRESENTATIVE SHALL OBSERVE ALL WARRANTED WORK, UPON WRITTEN REQUEST OF THE CONTRACTOR. THE REQUEST SHALL BE RECEIVED AT LEAST TEN CALENDAR DAYS BEFORE THE ANTICIPATED DATE FOR FINAL OBSERVATION. 2.END OF WARRANTY FINAL ACCEPTANCE WILL BE GIVEN ONLY WHEN ALL THE REQUIREMENTS OF THE WORK UNDER THIS SPECIFICATION AND IN SPECIFICATION SECTION IRRIGATION HAVE BEEN MET. 1.15 SELECTION AND OBSERVATION OF PLANTS A.THE OWNER'S REPRESENTATIVE MAY REVIEW ALL PLANTS SUBJECT TO APPROVAL OF SIZE, HEALTH, QUALITY, CHARACTER, ETC. REVIEW OR APPROVAL OF ANY PLANT DURING THE PROCESS OF SELECTION, DELIVERY, INSTALLATION AND ESTABLISHMENT PERIOD SHALL NOT PREVENT THAT PLANT FROM LATER REJECTION IN THE EVENT THAT THE PLANT QUALITY CHANGES OR PREVIOUSLY EXISTING DEFECTS BECOME APPARENT THAT WERE NOT OBSERVED. B.PLANT SELECTION: THE OWNER'S REPRESENTATIVE RESERVES THE RIGHT TO SELECT AND OBSERVE ALL PLANTS AT THE NURSERY PRIOR TO DELIVERY AND TO REJECT PLANTS THAT DO NOT MEET SPECIFICATIONS AS SET FORTH IN THIS SPECIFICATION. IF A PARTICULAR DEFECT OR SUBSTANDARD ELEMENT CAN BE CORRECTED AT THE NURSERY, AS DETERMINED BY THE OWNER'S REPRESENTATIVE, THE AGREED UPON REMEDY MAY BE APPLIED BY THE NURSERY OR THE CONTRACTOR PROVIDED THAT THE CORRECTION ALLOWS THE PLANT TO MEET THE REQUIREMENTS SET FORTH IN THIS SPECIFICATION. ANY WORK TO CORRECT PLANT DEFECTS SHALL BE AT THE CONTRACTOR'S EXPENSE. 1.THE OWNER'S REPRESENTATIVE MAY MAKE INVASIVE OBSERVATION OF THE TREE'S ROOT SYSTEM IN THE AREA OF THE ROOT COLLAR AND THE TOP OF THE ROOT BALL IN GENERAL IN ORDER TO DETERMINE THAT THE TREE MEETS THE QUALITY REQUIREMENTS FOR DEPTH OF THE ROOT COLLAR AND PRESENCE OF ROOTS ABOVE THE ROOT COLLAR. SUCH OBSERVATIONS WILL NOT HARM THE PLANT. 2.CORRECTIONS ARE TO BE UNDERTAKEN AT THE NURSERY PRIOR TO SHIPPING. C.THE CONTRACTOR SHALL BEAR ALL COST RELATED TO PLANT CORRECTIONS. D.ALL PLANTS THAT ARE REJECTED SHALL BE IMMEDIATELY REMOVED FROM THE SITE AND ACCEPTABLE REPLACEMENT PLANTS PROVIDED AT NO COST TO THE OWNER. E.SUBMIT TO THE OWNER'S REPRESENTATIVE, FOR APPROVAL, PLANT SOURCES INCLUDING THE NAMES AND LOCATIONS OF NURSERIES PROPOSED AS SOURCES OF ACCEPTABLE PLANTS, AND A LIST OF THE PLANTS THEY WILL PROVIDE. THE PLANT LIST SHALL INCLUDE THE BOTANICAL AND COMMON NAME AND THE SIZE AT THE TIME OF SELECTION. OBSERVE ALL NURSERY MATERIALS TO DETERMINE THAT THE MATERIALS MEET THE REQUIREMENTS OF THIS SECTION. F.TREES SHALL BE PURCHASED FROM THE GROWING NURSERY. RE-WHOLESALE PLANT SUPPLIERS SHALL NOT BE USED AS SOURCES UNLESS THE CONTRACTOR CAN CERTIFY THAT THE REQUIRED TREES ARE NOT DIRECTLY AVAILABLE FROM A GROWING NURSERY. WHEN RE-WHOLESALE SUPPLIERS ARE UTILIZED, THE CONTRACTOR SHALL SUBMIT THE NAME AND LOCATION OF THE GROWING NURSERY FROM WHERE THE TREES WERE OBTAINED BY THE RE-WHOLESALE SELLER. THE RE-WHOLESALE NURSERY SHALL BE RESPONSIBLE FOR ANY REQUIRED PLANT QUALITY CERTIFICATIONS. G.THE CONTRACTOR SHALL REQUIRE THE GROWER OR RE-WHOLESALE SUPPLIER TO PERMIT THE OWNER'S REPRESENTATIVE TO OBSERVE THE ROOT SYSTEM OF ALL PLANTS AT THE NURSERY OR JOB SITE PRIOR TO PLANTING INCLUDING RANDOM REMOVAL OF SOIL OR SUBSTRATE AROUND THE BASE OF THE PLANT. OBSERVATION MAY BE AS FREQUENT AND AS EXTENSIVE AS NEEDED TO VERIFY THAT THE PLANTS MEET THE REQUIREMENTS OF THE SPECIFICATIONS AND CONFORM TO REQUIREMENTS. H.EACH TREE SHALL HAVE A NUMBERED SEAL APPLIED BY THE CONTRACTOR. THE SEAL SHALL BE PLACED ON A LATERAL BRANCH ON THE NORTH SIDE OF THE TREE. THE SEAL SHALL BE A TAMPER PROOF PLASTIC SEAL BEARING THE CONTRACTORS NAME AND A UNIQUE SEVEN-DIGIT NUMBER EMBOSSED ON THE SEAL. 1.DO NOT PLACE SEALS ON BRANCHES THAT ARE SO LARGE THAT THERE IS NOT SUFFICIENT ROOM FOR THE BRANCH GROWTH OVER THE PERIOD OF THE WARRANTY. I.THE OWNER'S REPRESENTATIVE MAY CHOOSE TO ATTACH THEIR SEAL TO EACH PLANT, OR A REPRESENTATIVE SAMPLE. VIEWING AND/OR SEALING OF PLANTS BY THE OWNER'S REPRESENTATIVE AT THE NURSERY DOES NOT PRECLUDE THE OWNER'S REPRESENTATIVE'S RIGHT TO REJECT MATERIAL WHILE ON SITE. THE CONTRACTOR IS RESPONSIBLE FOR PAYING ANY UP CHARGE FOR THE OWNER'S REPRESENTATIVE TO ATTACH THEIR SEAL TO SPECIFIC PLANTS. J.WHERE REQUESTED BY THE OWNER'S REPRESENTATIVE, SUBMIT PHOTOGRAPHS OF PLANTS OR REPRESENTATIVE SAMPLES OF PLANTS. PHOTOGRAPHS SHALL BE LEGIBLE AND CLEARLY DEPICT THE PLANT SPECIMEN. EACH SUBMITTED IMAGE SHALL CONTAIN A HEIGHT REFERENCE, SUCH AS A MEASURING STICK. THE APPROVAL OF PLANTS BY THE OWNER'S REPRESENTATIVE VIA PHOTOGRAPH DOES NOT PRECLUDE THE OWNER'S REPRESENTATIVE'S RIGHT TO REJECT MATERIAL WHILE ON SITE. 1.16 PLANT SUBSTITUTIONS FOR PLANTS NOT AVAILABLE A.SUBMIT ALL REQUESTS FOR SUBSTITUTIONS OF PLANT SPECIES, OR SIZE TO THE OWNER'S REPRESENTATIVE, FOR APPROVAL, PRIOR TO PURCHASING THE PROPOSED SUBSTITUTION. REQUEST FOR SUBSTITUTION SHALL BE ACCOMPANIED WITH A LIST OF NURSERIES CONTACTED IN THE SEARCH FOR THE REQUIRED PLANT AND A RECORD OF OTHER ATTEMPTS TO LOCATE THE REQUIRED MATERIAL. REQUESTS SHALL ALSO INCLUDE SOURCES OF PLANTS FOUND THAT MAY BE OF A SMALLER OR LARGER SIZE, OR A DIFFERENT SHAPE OR HABIT THAN SPECIFIED, OR PLANTS OF THE SAME GENUS AND SPECIES BUT DIFFERENT CULTIVAR ORIGIN, OR WHICH MAY OTHERWISE NOT MEET THE REQUIREMENTS OF THE SPECIFICATIONS, BUT WHICH MAY BE AVAILABLE FOR SUBSTITUTION. 1.17 SITE CONDITIONS A.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BE AWARE OF ALL SURFACE AND SUB-SURFACE CONDITIONS, AND TO NOTIFY THE OWNER'S REPRESENTATIVE, IN WRITING, OF ANY CIRCUMSTANCES THAT WOULD NEGATIVELY IMPACT THE HEALTH OF PLANTINGS. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 1.SHOULD SUBSURFACE DRAINAGE OR SOIL CONDITIONS BE ENCOUNTERED WHICH WOULD BE DETRIMENTAL TO GROWTH OR SURVIVAL OF PLANT MATERIAL, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE IN WRITING, STATING THE CONDITIONS AND SUBMIT A PROPOSAL COVERING COST OF CORRECTIONS. IF THE CONTRACTOR FAILS TO NOTIFY THE OWNER'S REPRESENTATIVE OF SUCH CONDITIONS, HE/SHE SHALL REMAIN RESPONSIBLE FOR PLANT MATERIAL UNDER THE WARRANTY CLAUSE OF THE SPECIFICATIONS. B.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BE FAMILIAR WITH THE LOCAL GROWING CONDITIONS, AND IF ANY SPECIFIED PLANTS WILL BE IN CONFLICT WITH THESE CONDITIONS. REPORT ANY POTENTIAL CONFLICTS, IN WRITING, TO THE OWNER'S REPRESENTATIVE. C.THIS SPECIFICATION REQUIRES THAT ALL PLANTING SOIL AND IRRIGATION (IF APPLICABLE) WORK BE COMPLETED AND ACCEPTED PRIOR TO THE INSTALLATION OF ANY PLANTS. 1.PLANTING OPERATIONS SHALL NOT BEGIN UNTIL SUCH TIME THAT THE IRRIGATION SYSTEM IS COMPLETELY OPERATIONAL FOR THE AREA(S) TO BE PLANTED, AND THE IRRIGATION SYSTEM FOR THAT AREA HAS BEEN PRELIMINARILY OBSERVED AND APPROVED BY THE OWNER'S REPRESENTATIVE. D.ACTUAL PLANTING SHALL BE PERFORMED DURING THOSE PERIODS WHEN WEATHER AND SOIL CONDITIONS ARE SUITABLE IN ACCORDANCE WITH LOCALLY ACCEPTED HORTICULTURAL PRACTICES. 1.DO NOT INSTALL PLANTS INTO SATURATED OR FROZEN SOILS. DO NOT INSTALL PLANTS DURING INCLEMENT WEATHER, SUCH AS RAIN OR SNOW OR DURING EXTREMELY HOT, COLD OR WINDY CONDITIONS. 1.18 PLANTING AROUND UTILITIES A.CONTRACTOR SHALL CAREFULLY EXAMINE THE CIVIL, RECORD, AND SURVEY DRAWINGS TO BECOME FAMILIAR WITH THE EXISTING UNDERGROUND CONDITIONS BEFORE DIGGING. B.DETERMINE LOCATION OF UNDERGROUND UTILITIES AND PERFORM WORK IN A MANNER THAT WILL AVOID POSSIBLE DAMAGE. HAND EXCAVATE, AS REQUIRED. MAINTAIN GRADE STAKES SET BY OTHERS UNTIL PARTIES CONCERNED MUTUALLY AGREE UPON REMOVAL. C.NOTIFICATION OF LOCAL UTILITY LOCATOR SERVICE (AS NOTED ON DRAWINGS) IS REQUIRED FOR ALL PLANTING AREAS THE CONTRACTOR IS RESPONSIBLE FOR KNOWING THE LOCATION AND AVOIDING UTILITIES THAT ARE NOT COVERED BY THE LOCAL UTILITY LOCATOR SERVICE. PART 2 PRODUCTS 2.1 PLANTS: GENERAL A.STANDARDS AND MEASUREMENT: PROVIDE PLANTS OF QUANTITY, SIZE, GENUS, SPECIES, AND VARIETY OR CULTIVARS AS SHOWN AND SCHEDULED IN CONTRACT DOCUMENTS. 1.ALL PLANTS, INCLUDING THE ROOT BALL DIMENSIONS OR CONTAINER SIZE TO TRUNK CALIPER RATIO, SHALL CONFORM TO ANSI Z60.1 “AMERICAN STANDARD FOR NURSERY STOCK” LATEST EDITION, UNLESS MODIFIED BY PROVISIONS IN THIS SPECIFICATION. WHEN THERE IS A CONFLICT BETWEEN THIS SPECIFICATION AND ANSI Z60.1, THIS SPECIFICATION SECTION SHALL BE CONSIDERED CORRECT. 2.PLANTS LARGER THAN SPECIFIED MAY BE USED IF ACCEPTABLE TO THE OWNER'S REPRESENTATIVE. USE OF SUCH PLANTS SHALL NOT INCREASE THE CONTRACT PRICE. IF LARGER PLANTS ARE ACCEPTED THE ROOT BALL SIZE SHALL BE IN ACCORDANCE WITH ANSI Z-60.1. LARGER PLANTS MAY NOT BE ACCEPTABLE IF THE RESULTING ROOT BALL CANNOT BE FIT INTO THE REQUIRED PLANTING SPACE. 3.IF A RANGE OF SIZE IS GIVEN, NO PLANT SHALL BE LESS THAN THE MINIMUM SIZE AND NOT LESS THAN 50 PERCENT OF THE PLANTS SHALL BE AS LARGE AS THE MAXIMUM SIZE SPECIFIED. THE MEASUREMENTS SPECIFIED ARE THE MINIMUM AND MAXIMUM SIZE ACCEPTABLE AND ARE THE MEASUREMENTS AFTER PRUNING, WHERE PRUNING IS REQUIRED. B.PROPER IDENTIFICATION: ALL TREES SHALL BE TRUE TO NAME AS ORDERED OR SHOWN ON PLANTING PLANS AND SHALL BE LABELED INDIVIDUALLY OR IN GROUPS BY GENUS, SPECIES, VARIETY AND CULTIVAR. C.COMPLIANCE: ALL TREES SHALL COMPLY WITH FEDERAL AND STATE LAWS AND REGULATIONS REQUIRING OBSERVATION FOR PLANT DISEASE, PESTS, AND WEEDS. OBSERVATION CERTIFICATES REQUIRED BY LAW SHALL ACCOMPANY EACH SHIPMENT OF PLANTS. 1.CLEARANCE FROM THE LOCAL COUNTY AGRICULTURAL COMMISSIONER, IF REQUIRED, SHALL BE OBTAINED BEFORE PLANTING TREES ORIGINATING OUTSIDE THE COUNTY IN WHICH THEY ARE TO BE PLANTED. D.PLANT QUALITY: 1.GENERAL: PROVIDE HEALTHY STOCK, GROWN IN A NURSERY AND REASONABLY FREE OF DIE-BACK, DISEASE, INSECTS, EGGS, BORES, AND LARVAE. AT THE TIME OF PLANTING ALL PLANTS SHALL HAVE A ROOT SYSTEM, STEM, AND BRANCH FORM THAT WILL NOT RESTRICT NORMAL GROWTH, STABILITY AND HEALTH FOR THE EXPECTED LIFE OF THE PLANT 2.PLANT QUALITY ABOVE THE SOIL LINE: a.PLANTS SHALL BE HEALTHY WITH THE COLOR, SHAPE, SIZE AND DISTRIBUTION OF TRUNK, STEMS, BRANCHES, BUDS AND LEAVES NORMAL TO THE PLANT TYPE SPECIFIED. TREE QUALITY ABOVE THE SOIL LINE SHALL COMPLY WITH THE PROJECT CROWN ACCEPTANCE DETAILS AND THE FOLLOWING: 1.)CROWN: THE FORM AND DENSITY OF THE CROWN SHALL BE TYPICAL FOR A YOUNG SPECIMEN OF THE SPECIES OR CULTIVAR PRUNED TO A CENTRAL AND DOMINANT LEADER. A.)CROWN SPECIFICATIONS DO NOT APPLY TO PLANTS THAT HAVE BEEN SPECIFICALLY TRAINED IN THE NURSERY AS TOPIARY, ESPALIER, MULTI-STEM, CLUMP, OR UNIQUE SELECTIONS SUCH AS CONTORTED OR WEEPING CULTIVARS. 2.)LEAVES: THE SIZE, COLOR, AND APPEARANCE OF LEAVES SHALL BE TYPICAL FOR THE TIME OF YEAR AND STAGE OF GROWTH OF THE SPECIES OR CULTIVAR. TREES SHALL NOT SHOW SIGNS OF PROLONGED MOISTURE STRESS OR OVER WATERING AS INDICATED BY WILTED, SHRIVELED, OR DEAD LEAVES. 3.)BRANCHES: SHOOT GROWTH (LENGTH AND DIAMETER) THROUGHOUT THE CROWN SHOULD BE APPROPRIATE FOR THE AGE AND SIZE OF THE SPECIES OR CULTIVAR. TREES SHALL NOT HAVE DEAD, DISEASED, BROKEN, DISTORTED, OR OTHERWISE INJURED BRANCHES. A.)MAIN BRANCHES SHALL BE DISTRIBUTED ALONG THE CENTRAL LEADER NOT CLUSTERED TOGETHER. THEY SHALL FORM A BALANCED CROWN APPROPRIATE FOR THE CULTIVAR/SPECIES. B.) BRANCH DIAMETER SHALL BE NO LARGER THAN TWO-THIRDS (ONE-HALF IS PREFERRED) THE DIAMETER OF THE CENTRAL LEADER MEASURED 1 INCH ABOVE THE BRANCH UNION. C.) THE ATTACHMENT OF THE LARGEST BRANCHES (SCAFFOLD BRANCHES) SHALL BE FREE OF INCLUDED BARK. 4.)TRUNK: THE TREE TRUNK SHALL BE RELATIVELY STRAIGHT, VERTICAL, AND FREE OF WOUNDS THAT PENETRATE TO THE WOOD (PROPERLY MADE PRUNING CUTS, CLOSED OR NOT, ARE ACCEPTABLE AND ARE NOT CONSIDERED WOUNDS), SUNBURNED AREAS, CONKS (FUNGAL FRUITING BODIES), WOOD CRACKS, SAP LEAKAGE, SIGNS OF BORING INSECTS, GALLS, CANKERS, GIRDLING TIES, OR LESIONS (MECHANICAL INJURY). 5.) TEMPORARY BRANCHES, UNLESS OTHERWISE SPECIFIED, CAN BE PRESENT ALONG THE LOWER TRUNK BELOW THE LOWEST MAIN (SCAFFOLD) BRANCH, PARTICULARLY FOR TREES LESS THAN 1 INCH IN CALIPER. THESE BRANCHES SHOULD BE NO GREATER THAN 3/8-INCH DIAMETER. CLEAR TRUNK SHOULD BE NO MORE THAN 40% OF THE TOTAL HEIGHT OF THE TREE, UNLESS OTHERWISE SPECIFIED ON THE DRAWINGS (WHICHEVER IS GREATER). b.TREES SHALL HAVE ONE CENTRAL LEADER AS NOTED IN PLANT LIST. IF THE LEADER WAS HEADED, A NEW LEADER (WITH A LIVE TERMINAL BUD) AT LEAST ONE-HALF THE DIAMETER OF THE PRUNING CUT SHALL BE PRESENT. 1.)ALL TREES ARE ASSUMED TO HAVE ONE CENTRAL LEADER TREES UNLESS A DIFFERENT FORM IS SPECIFIED IN THE PLANT LIST OR DRAWINGS. c.ALL GRAFT UNIONS, WHERE APPLICABLE, SHALL BE COMPLETELY CLOSED WITHOUT VISIBLE SIGN OF GRAFT REJECTION. ALL GRAFTS SHALL BE VISIBLE ABOVE THE SOIL LINE. d.TRUNK CALIPER AND TAPER SHALL BE SUFFICIENT SO THAT THE LOWER FIVE FEET OF THE TRUNK REMAINS VERTICAL WITHOUT A STAKE. AUXILIARY STAKE MAY BE USED TO MAINTAIN A STRAIGHT LEADER IN THE UPPER HALF OF THE TREE. 3.PLANT QUALITY AT OR BELOW THE SOIL LINE: a.PLANT ROOTS SHALL BE NORMAL TO THE PLANT TYPE SPECIFIED. ROOT OBSERVATIONS SHALL TAKE PLACE WITHOUT IMPACTING TREE HEALTH. ROOT QUALITY AT OR BELOW THE SOIL LINE SHALL COMPLY WITH THE PROJECT ROOT ACCEPTANCE DETAILS AND THE FOLLOWING: 1.) THE ROOTS SHALL BE REASONABLY FREE OF SCRAPES, BROKEN OR SPLIT WOOD. 2.) THE ROOT SYSTEM SHALL BE REASONABLY FREE OF INJURY FROM BIOTIC (E.G., INSECTS AND PATHOGENS) AND ABIOTIC (E.G., HERBICIDE TOXICITY AND SALT INJURY) AGENTS. WOUNDS RESULTING FROM ROOT PRUNING USED TO PRODUCE A HIGH QUALITY ROOT SYSTEM ARE NOT CONSIDERED INJURIES. 3.) A MINIMUM OF THREE STRUCTURAL ROOTS REASONABLY DISTRIBUTED AROUND THE TRUNK (NOT CLUSTERED ON ONE SIDE) SHALL BE FOUND IN EACH PLANT. ROOT DISTRIBUTION SHALL BE UNIFORM THROUGHOUT THE ROOT BALL, AND GROWTH SHALL BE APPROPRIATE FOR THE SPECIES. A.) PLANTS WITH STRUCTURAL ROOTS ON ONLY ONE SIDE OF THE TRUNK (J ROOTS) SHALL BE REJECTED. 4.) THE ROOT COLLAR SHALL BE WITHIN THE UPPER 2 INCHES OF THE SUBSTRATE/SOIL. TWO STRUCTURAL ROOTS SHALL REACH THE SIDE OF THE ROOT BALL NEAR THE TOP SURFACE OF THE ROOT BALL. THE GROWER MAY REQUEST A MODIFICATION TO THIS REQUIREMENT FOR SPECIES WITH ROOTS THAT RAPIDLY DESCEND, PROVIDED THAT THE GROWER REMOVES ALL STEM GIRDLING ROOTS ABOVE THE STRUCTURAL ROOTS ACROSS THE TOP OF THE ROOT BALL. 5.) THE ROOT SYSTEM SHALL BE REASONABLY FREE OF STEM GIRDLING ROOTS OVER THE ROOT COLLAR OR KINKED ROOTS FROM NURSERY PRODUCTION PRACTICES. 6.) AT TIME OF OBSERVATIONS AND DELIVERY, THE ROOT BALL SHALL BE MOIST THROUGHOUT. ROOTS SHALL NOT SHOW SIGNS OF EXCESS SOIL MOISTURE CONDITIONS AS INDICATED BY STUNTED, DISCOLORED, DISTORTED, OR DEAD ROOTS. 2. 2 ROOT BALL PACKAGE OPTIONS: THE FOLLOWING ROOT BALL PACKAGES ARE PERMITTED. SPECIFIC ROOT BALL PACKAGES SHALL BE REQUIRED WHERE INDICATED ON THE PLANT LIST OR IN THIS SPECIFICATION. ANY TYPE OF ROOT BALL PACKAGES THAT IS NOT SPECIFICALLY DEFINED IN THIS SPECIFICATION SHALL NOT BE PERMITTED. A.BALLED AND BURLAPPED PLANTS 1.ALL BALLED AND BURLAPPED PLANTS SHALL BE FIELD GROWN, AND THE ROOT BALL PACKAGED IN A BURLAP AND TWINE AND/OR BURLAP AND WIRE BASKET PACKAGE. 2.PLANTS SHALL BE HARVESTED WITH THE FOLLOWING MODIFICATIONS TO STANDARD NURSERY PRACTICES. a.PRIOR TO DIGGING ANY TREE THAT FAILS TO MEET THE REQUIREMENT FOR MAXIMUM SOIL AND ROOTS ABOVE THE ROOT COLLAR, CAREFULLY REMOVED THE SOIL FROM THE TOP OF THE ROOT BALL OF EACH PLANT, USING HAND TOOLS, WATER OR AN AIR SPADE, TO LOCATE THE ROOT COLLAR AND ATTAIN THE SOIL DEPTH OVER THE STRUCTURAL ROOTS REQUIREMENTS. REMOVE ALL STEM GIRDLING ROOTS ABOVE THE ROOT COLLAR. CARE MUST BE EXERCISED NOT TO DAMAGE THE SURFACE OF THE ROOT COLLAR AND THE TOP OF THE STRUCTURAL ROOTS. b.TREES SHALL BE DUG FOR A MINIMUM OF 4 WEEKS AND A MAXIMUM OF 52 WEEKS PRIOR TO SHIPPING. TREES DUG 4 TO 52 WEEKS PRIOR TO SHIPPING ARE DEFINED AS HARDENED-OFF. DIGGING IS DEFINED AS CUTTING ALL ROOTS AND LIFTING THE TREE OUT OF THE GROUND AND EITHER MOVING IT TO A NEW LOCATION IN THE NURSERY OR PLACING IT BACK INTO THE SAME HOLE. TRESS THAT ARE STORED OUT OF THE GROUND SHALL BE PLACED IN A HOLDING AREA PROTECTED FROM EXTREMES OF WIND AND SUN WITH THE ROOT BALL PROTECTED BY COVERING WITH MULCH OR STRAW AND IRRIGATED SUFFICIENTLY TO KEEP MOISTURE IN THE ROOT BALL ABOVE WILT POINT AND BELOW SATURATION c.TWINE AND BURLAP USED FOR WRAPPING THE ROOT BALL PACKAGE SHALL BE NATURAL, BIODEGRADABLE MATERIAL. IF THE BURLAP DECOMPOSES AFTER DIGGING THE TREE THEN THE ROOT BALL SHALL BE RE-WRAPPED PRIOR TO SHIPPING IF ROOTS HAVE NOT YET GROWN TO KEEP ROOT BALL INTACT DURING SHIPPING. B.CONTAINER (INCLUDING ABOVE-GROUND FABRIC CONTAINERS AND BOXES) PLANTS 1.CONTAINER PLANTS MAY BE PERMITTED ONLY WHEN INDICATED ON THE DRAWING, IN THIS SPECIFICATION, OR APPROVED BY THE OWNER'S REPRESENTATIVE. 2.PROVIDE PLANTS SHALL BE ESTABLISHED AND WELL ROOTED IN REMOVABLE CONTAINERS. 3.CONTAINER CLASS SIZE SHALL CONFORM TO ANSI Z60.1 FOR CONTAINER PLANTS FOR EACH SIZE AND TYPE OF PLANT. 2.3 ANNUAL FLOWERING AND SEASONAL COLOR PLANTS A.CONTAINER OR FLAT-GROWN PLANTS SHOULD BE SIZED AS NOTED IN THE PLANTING PLAN. PLANTS SHALL BE WELL-ROOTED AND HEALTHY. 34 BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.LANDSCAPE SPECIFICATIONSLP 2.02 1.MODIFICATIONS, AT THE TIME OF PLANTING, TO MEET THE SPECIFICATIONS FOR THE DEPTH OF THE ROOT COLLAR AND REMOVAL OF STEM GIRDLING ROOTS AND CIRCLING ROOTS MAY MAKE THE PLANT UNSTABLE OR STRESS THE PLANT TO THE POINT THAT THE OWNER'S REPRESENTATIVE MAY CHOOSE TO REJECT THE PLANT RATHER THAN PERMITTING THE MODIFICATION. 2.ANY MODIFICATIONS REQUIRED BY THE OWNER'S REPRESENTATIVE TO MAKE THE ROOT SYSTEM CONFORM TO THE PLANT QUALITY STANDARDS OUTLINED IN PART 2 PRODUCTS: PLANTS GENERAL: QUALITY, OR OTHER REQUIREMENTS RELATED TO THE PERMITTED ROOT BALL PACKAGE, SHALL NOT BE CONSIDERED AS GROUNDS TO MODIFY OR VOID THE PLANT WARRANTY. 3.THE RESULTING ROOT BALL MAY NEED ADDITIONAL STAKING AND WATER AFTER PLANTING. THE OWNER'S REPRESENTATIVE MAY REJECT THE PLANT IF THE ROOT MODIFICATION PROCESS MAKES THE TREE UNSTABLE OR IF THE TREE IS NOT HEALTHY AT THE END OF THE WARRANTY PERIOD. SUCH PLANTS SHALL STILL BE COVERED UNDER THE WARRANTY 4.THE CONTRACTOR REMAINS RESPONSIBLE TO CONFIRM THAT THE GROWER HAS MADE ALL REQUIRED ROOT MODIFICATIONS NOTED DURING ANY NURSERY OBSERVATIONS. D.CONTAINER AND BOXED ROOT BALL SHAVING (IF REQUIRED -SEE DRAWINGS FOR CONDITIONS): THE OUTER SURFACES OF ALL PLANTS IN CONTAINERS AND BOXES, INCLUDING THE TOP, SIDES AND BOTTOM OF THE ROOT BALL SHALL BE SHAVED TO REMOVE ALL CIRCLING, DESCENDING, AND MATTED ROOTS. SHAVING SHALL BE PERFORMED USING SAWS, KNIVES, SHARP SHOVELS OR OTHER SUITABLE EQUIPMENT THAT IS CAPABLE OF MAKING CLEAN CUTS ON THE ROOTS. SHAVING SHALL REMOVE A MINIMUM OF ONE INCH OF ROOT MAT OR UP TO 2 INCHES AS REQUIRED TO REMOVE ALL ROOT SEGMENTS THAT ARE NOT GROWING REASONABLY RADIAL TO THE TRUNK. E.EXPOSED STEM TISSUE AFTER MODIFICATION: THE REQUIRED ROOT BALL MODIFICATIONS MAY RESULT IN STEM TISSUE THAT HAS NOT FORMED TRUNK BARK BEING EXPOSED ABOVE THE SOIL LINE. IF SUCH CONDITION OCCURS, WRAP THE EXPOSED PORTION OF THE STEM IN A PROTECTIVE WRAPPING WITH A WHITE FILTER FABRIC. SECURE THE FABRIC WITH BIODEGRADABLE MASKING TAPE. DO NOT USE STRING, TWINE, GREEN NURSERY TIES OR ANY OTHER MATERIAL THAT MAY GIRDLE THE TRUNK IF NOT REMOVED. F.EXCAVATION OF THE PLANTING SPACE: USING HAND TOOLS OR TRACKED MINI-EXCAVATOR, EXCAVATE THE PLANTING HOLE INTO THE PLANTING SOIL TO THE DEPTH OF THE ROOT BALL MEASURED AFTER ANY ROOT BALL MODIFICATION TO CORRECT ROOT PROBLEMS, AND WIDE ENOUGH FOR WORKING ROOM AROUND THE ROOT BALL OR TO THE SIZE INDICATED ON THE DRAWING OR AS NOTED BELOW. 1.FOR TREES AND SHRUBS PLANTED IN SOIL AREAS THAT ARE NOT TILLED OR OTHERWISE MODIFIED TO A DEPTH OF AT LEAST 12 INCHES OVER A DISTANCE OF MORE THAN 10 FEET RADIUS FROM EACH TREE, OR 5 FEET RADIUS FROM EACH SHRUB, THE SOIL AROUND THE ROOT BALL SHALL BE LOOSENED AS DEFINED BELOW OR AS INDICATED ON THE DRAWINGS. a.THE AREA OF LOOSENING SHALL BE A MINIMUM OF 3 TIMES THE DIAMETER OF THE ROOT BALL AT THE SURFACE SLOPING TO 2 TIMES THE DIAMETER OF THE ROOT BALL AT THE DEPTH OF THE ROOT BALL. b.LOOSENING IS DEFINED AS DIGGING INTO THE SOIL AND TURNING THE SOIL TO REDUCE THE COMPACTION. THE SOIL DOES NOT HAVE TO BE REMOVED FROM THE HOLE, JUST DUG, LIFTED AND TURNED. LIFTING AND TURNING MAY BE ACCOMPLISHED WITH A TRACKED MINI EXCAVATOR, OR HAND SHOVELS. 2.IF AN AUGER IS USED TO DIG THE INITIAL PLANTING HOLE, THE SOIL AROUND THE AUGER HOLE SHALL BE LOOSENED AS DEFINED ABOVE FOR TREES AND SHRUBS PLANTED IN SOIL AREAS THAT ARE NOT TILLED OR OTHERWISE MODIFIED. 3.THE MEASURING POINT FOR ROOT BALL DEPTH SHALL BE THE AVERAGE HEIGHT OF THE OUTER EDGE OF THE ROOT BALL AFTER ANY REQUIRED ROOT BALL MODIFICATION. 4.IF MOTORIZED EQUIPMENT IS USED TO DELIVER PLANTS TO THE PLANTING AREA OVER EXPOSED PLANTING BEDS, OR USED TO LOOSEN THE SOIL OR DIG THE PLANTING HOLES, ALL SOIL THAT HAS BEEN DRIVEN OVER SHALL BE TILLED TO A DEPTH OF 6 INCHES. G.FOR TREES TO BE PLANTED IN PREPARED PLANTING SOIL THAT IS DEEPER THAN THE ROOT BALL DEPTH, COMPACT THE SOIL UNDER THE ROOT BALL USING A MECHANICAL TAMPER TO ASSURE A FIRM BEDDING FOR THE ROOT BALL. IF THERE IS MORE THAN 12 INCHES OF PLANTING SOIL UNDER THE ROOT BALL EXCAVATE AND TAMP THE PLANTING SOIL IN LIFTS NOT TO EXCEED 12 INCHES. H.SET TOP OUTER EDGE OF THE ROOT BALL AT THE AVERAGE ELEVATION OF THE PROPOSED FINISH. SET THE PLANT PLUMB AND UPRIGHT IN THE CENTER OF THE PLANTING HOLE. THE TREE GRAFT, IF APPLICABLE, SHALL BE VISIBLE ABOVE THE GRADE. DO NOT PLACE SOIL ON TOP OF THE ROOT BALL. I.THE OWNER'S REPRESENTATIVE MAY REQUEST THAT PLANTS ORIENTATION BE ROTATED WHEN PLANTED BASED ON THE FORM OF THE PLANT. J.BACKFILL THE SPACE AROUND THE ROOT BALL WITH THE SAME PLANTING SOIL OR EXISTING SOIL THAT WAS EXCAVATED FOR THE PLANTING SPACE. SEE SPECIFICATION SECTION PLANTING SOIL, FOR REQUIREMENTS TO MODIFY THE SOIL WITHIN THE PLANTING BED. K.BRACE ROOT BALL BY TAMPING PLANTING SOIL AROUND THE LOWER PORTION OF THE ROOT BALL. PLACE ADDITIONAL PLANTING SOIL AROUND BASE AND SIDES OF BALL IN SIX-INCH (6") LIFTS. LIGHTLY TAMP EACH LIFT USING FOOT PRESSURE OR HAND TOOLS TO SETTLE BACKFILL, SUPPORT THE TREE AND ELIMINATE VOIDS. DO NOT OVER COMPACT THE BACKFILL OR USE MECHANICAL OR PNEUMATIC TAMPING EQUIPMENT. OVER COMPACTION SHALL BE DEFINED AS GREATER THAN 85% OF MAXIMUM DRY DENSITY, STANDARD PROCTOR OR GREATER THAN 250 PSI AS MEASURED BY A CONE PENETROMETER WHEN THE VOLUMETRIC SOIL MOISTURE IS LOWER THAN FIELD CAPACITY. 1.WHEN THE PLANTING HOLE HAS BEEN BACKFILLED TO THREE QUARTERS OF ITS DEPTH, WATER SHALL BE POURED AROUND THE ROOT BALL AND ALLOWED TO SOAK INTO THE SOIL TO SETTLE THE SOIL. DO NOT FLOOD THE PLANTING SPACE. IF THE SOIL IS ABOVE FIELD CAPACITY, ALLOW THE SOIL TO DRAIN TO BELOW FIELD CAPACITY BEFORE FINISHING THE PLANTING. AIR POCKETS SHALL BE ELIMINATED AND BACKFILL CONTINUED UNTIL THE PLANTING SOIL IS BROUGHT TO GRADE LEVEL. L.WHERE INDICATED ON THE DRAWINGS, BUILD A 4 INCH HIGH, LEVEL BERM OF PLANTING SOIL AROUND THE OUTSIDE OF THE ROOT BALL TO RETAIN WATER. TAMP THE BERM TO REDUCE LEAKING AND EROSION OF THE SAUCER. M.THOROUGHLY WATER THE PLANTING SOIL AND ROOT BALL IMMEDIATELY AFTER PLANTING. N.REMOVE ALL NURSERY PLANT IDENTIFICATION TAGS AND RIBBONS AS PER OWNER'S REPRESENTATIVE INSTRUCTIONS. THE OWNER'S REPRESENTATIVE'S SEALS ARE TO REMAIN ON PLANTS UNTIL THE END OF THE WARRANTY PERIOD. O.REMOVE ANY CORRUGATED CARDBOARD TRUNK PROTECTION AFTER PLANTING. P.FOLLOW ADDITIONAL REQUIREMENTS FOR THE PERMITTED ROOT BALL PACKAGES. 3.10 PERMITTED ROOT BALL PACKAGES AND SPECIAL PLANTING REQUIREMENTS A.THE FOLLOWING ARE PERMITTED ROOT BALL PACKAGES AND SPECIAL PLANTING REQUIREMENTS THAT SHALL BE FOLLOWED DURING THE PLANTING PROCESS IN ADDITION TO THE ABOVE GENERAL PLANTING REQUIREMENTS. B.BALLED AND BURLAPPED PLANTS 1.AFTER THE ROOT BALL HAS BEEN BACKFILLED, REMOVE ALL TWINE AND BURLAP FROM THE TOP OF THE ROOT BALL. CUT THE BURLAP AWAY AS INDICATED ON DRAWINGS; DO NOT FOLD DOWN ONTO THE PLANTING SOIL. 2.IF THE PLANT IS SHIPPED WITH A WIRE BASKET REMOVE THE BASKET WIRES JUST BEFORE THE FINAL BACKFILLING OF THE TREE AS INDICATED ON THE DRAWINGS. 3.EARTH ROOT BALLS SHALL BE KEPT INTACT EXCEPT FOR ANY MODIFICATIONS REQUIRED BY THE OWNER'S REPRESENTATIVE TO MAKE ROOT PACKAGE COMPLY WITH THE REQUIREMENT IN PART 2 PRODUCTS. C.CONTAINER PLANTS 1.THIS SPECIFICATION ASSUMES THAT MOST CONTAINER PLANTS HAVE SIGNIFICANT STEM GIRDLING AND CIRCLING ROOTS, AND THAT THE ROOT COLLAR IS TOO LOW IN THE ROOT BALL. 2.REMOVE THE CONTAINER. 3.PERFORM ROOT BALL SHAVING AS DEFINED IN INSTALLATION OF PLANTS: GENERAL ABOVE. 4.REMOVE ALL ROOTS AND SUBSTRATE ABOVE THE ROOT COLLAR AND THE MAIN STRUCTURAL ROOTS ACCORDING TO ROOT CORRECTION DETAILS SO ROOT SYSTEM CONFORMS TO ROOT OBSERVATIONS DETAIL. 5.REMOVE ALL SUBSTRATE AT THE BOTTOM OF THE ROOT BALL THAT DOES NOT CONTAIN ROOTS. 6.USING A HOSE, POWER WASHER OR AIR EXCAVATION DEVICE, WASH OUT THE SUBSTRATE FROM AROUND THE TRUNK AND TOP OF THE REMAINING ROOT BALL AND FIND AND REMOVE ALL STEM GIRDLING ROOTS WITHIN THE ROOT BALL ABOVE THE TOP OF THE STRUCTURAL ROOTS. 3.11 GROUND COVER, PERENNIAL AND ANNUAL PLANTS A.ASSURE THAT SOIL MOISTURE IS WITHIN THE REQUIRED LEVELS PRIOR TO PLANTING. IRRIGATION, IF REQUIRED, SHALL BE APPLIED AT LEAST 12 HOURS PRIOR TO PLANTING TO AVOID PLANTING IN MUDDY SOILS. B.ASSURE THAT SOIL GRADES IN THE BEDS ARE SMOOTH AND AS SHOWN ON THE PLANS. C.PLANTS SHALL BE PLANTED IN EVEN, TRIANGULARLY SPACED ROWS, AT THE INTERVALS CALLED OUT FOR ON THE DRAWINGS, UNLESS OTHERWISE NOTED. THE FIRST ROW OF ANNUAL FLOWER PLANTS SHALL BE 6 INCHES FROM THE BED EDGE UNLESS OTHERWISE DIRECTED. D.DIG PLANTING HOLES SUFFICIENTLY LARGE ENOUGH TO INSERT THE ROOT SYSTEM WITHOUT DEFORMING THE ROOTS. SET THE TOP OF THE ROOT SYSTEM AT THE GRADE OF THE SOIL. E.SCHEDULE THE PLANTING TO OCCUR PRIOR TO APPLICATION OF THE MULCH. IF THE BED IS ALREADY MULCHED, PULL THE MULCH FROM AROUND THE HOLE AND PLANT INTO THE SOIL. DO NOT PLANT THE ROOT SYSTEM IN THE MULCH. PULL MULCH BACK SO IT IS NOT ON THE ROOT BALL SURFACE. F.PRESS SOIL TO BRING THE ROOT SYSTEM IN CONTACT WITH THE SOIL. G.SPREAD ANY EXCESS SOIL AROUND IN THE SPACES BETWEEN PLANTS. H.APPLY MULCH TO THE BED BEING SURE NOT TO COVER THE TOPS OF THE PLANTS WITH OR THE TOPS OF THE ROOT BALL WITH MULCH. I.WATER EACH PLANTING AREA AS SOON AS THE PLANTING IS COMPLETED. APPLY ADDITIONAL WATER TO KEEP THE SOIL MOISTURE AT THE REQUIRED LEVELS. DO NOT OVER WATER. 3.12 STAKING AND GUYING A.DO NOT STAKE TREES UNLESS SPECIFICALLY REQUIRED BY THE CONTRACT DOCUMENTS, OR IN THE EVENT THAT THE CONTRACTOR FEELS THAT STAKING IS THE ONLY ALTERNATIVE WAY TO KEEP PARTICULAR TREES PLUMB. 1.THE OWNER'S REPRESENTATIVE SHALL HAVE THE AUTHORITY TO REQUIRE THAT TREES ARE STAKED OR TO REJECT STAKING AS AN ALTERNATIVE WAY TO STABILIZE THE TREE. 2.TREES THAT REQUIRED HEAVILY MODIFIED ROOT BALLS TO MEET THE ROOT QUALITY STANDARDS MAY BECOME UNSTABLE. THE OWNER'S REPRESENTATIVE MAY CHOOSE TO REJECT THESE TREES RATHER THAN UTILIZE STAKING TO TEMPORARILY SUPPORT THE TREE. 3.PLANTS SHALL STAND PLUMB AFTER STAKING. 4.STAKES SHALL BE DRIVEN TO SUFFICIENT DEPTH TO HOLD THE TREE RIGID. 3.13 STRAIGHTENING PLANTS B.MAINTAIN ALL PLANTS IN A PLUMB POSITION THROUGHOUT THE WARRANTY PERIOD. STRAIGHTEN ALL TREES THAT MOVE OUT OF PLUMB INCLUDING THOSE NOT STAKED. PLANTS TO BE STRAIGHTENED SHALL BE EXCAVATED AND THE ROOT BALL MOVED TO A PLUMB POSITION, AND THEN RE-BACKFILLED. C.DO NOT STRAIGHTEN PLANTS BY PULLING THE TRUNK WITH GUYS. 3.14 INSTALLATION OF FERTILIZER AND OTHER CHEMICAL ADDITIVES A.DO NOT APPLY ANY SOLUBLE FERTILIZER TO PLANTINGS DURING THE FIRST YEAR AFTER TRANSPLANTING UNLESS SOIL TEST DETERMINES THAT FERTILIZER OR OTHER CHEMICAL ADDITIVES IS REQUIRED. APPLY CHEMICAL ADDITIVES ONLY UPON THE APPROVAL OF THE OWNER'S REPRESENTATIVE. B.CONTROLLED RELEASE FERTILIZERS SHALL BE APPLIED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS, STANDARD HORTICULTURAL PRACTICES, AND PER THE SOIL TEST RECOMMENDATIONS. 3.15 PRUNING OF TREES AND SHRUBS A.PRUNE PLANTS AS DIRECTED BY THE OWNER'S REPRESENTATIVE. PRUNING TREES SHALL BE LIMITED TO ADDRESSING STRUCTURAL DEFECTS AS SHOWN IN DETAILS; FOLLOW RECOMMENDATIONS IN “STRUCTURAL PRUNING: A GUIDE FOR THE GREEN INDUSTRY” PUBLISHED BY URBAN TREE FOUNDATION, VISALIA CA. B.ALL PRUNING SHALL BE PERFORMED BY A PERSON EXPERIENCED IN STRUCTURAL TREE PRUNING. C.EXCEPT FOR PLANTS SPECIFIED AS MULTI-STEMMED OR AS OTHERWISE INSTRUCTED BY THE OWNER'S REPRESENTATIVE, PRESERVE OR CREATE A CENTRAL LEADER. D.PRUNING OF LARGE TREES SHALL BE DONE USING POLE PRUNERS OR IF NEEDED, FROM A LADDER OR HYDRAULIC LIFT TO GAIN ACCESS TO THE TOP OF THE TREE. DO NOT CLIMB IN NEWLY PLANTED TREES. SMALL TREES CAN BE STRUCTURALLY PRUNED BY LAYING THEM OVER BEFORE PLANTING. PRUNING MAY ALSO BE PERFORMED AT THE NURSERY PRIOR TO SHIPPING. E.REMOVE AND REPLACE EXCESSIVELY PRUNED OR MALFORMED STOCK RESULTING FROM IMPROPER PRUNING THAT OCCURRED IN THE NURSERY OR AFTER. F.PRUNING SHALL BE DONE WITH CLEAN, SHARP TOOLS. G.NO TREE PAINT OR SEALANTS SHALL BE USED. 3.16 MULCHING OF PLANTS A.APPLY MULCH BEFORE SETTLEMENT TO DEPTH SHOWN ON PLANS, COVERING THE ENTIRE PLANTING BED AREA. INSTALL NO MORE THAN 1 INCH OF MULCH OVER THE TOP OF THE ROOT BALLS OF ALL PLANTS. TAPER TO 2 INCHES WHEN ABUTTING PAVEMENT. B.FOR TREES PLANTED IN LAWN AREAS THE MULCH SHALL EXTEND TO A 4 FOOT RADIUS AROUND THE TREE OR TO THE EXTENT INDICATED ON THE PLANS. C.LIFT ALL LEAVES, LOW HANGING STEMS AND OTHER GREEN PORTIONS OF SMALL PLANTS OUT OF THE MULCH IF COVERED. 3.17 PLANTING BED FINISHING A.AFTER PLANTING, SMOOTH OUT ALL GRADES BETWEEN PLANTS BEFORE MULCHING. B.SEPARATE THE EDGES OF PLANTING BEDS AND LAWN AREAS WITH A SMOOTH, FORMED EDGE CUT INTO THE TURF WITH THE BED MULCH LEVEL SLIGHTLY LOWER, 1 AND 2 INCHES, THAN THE ADJACENT TURF SOD OR AS DIRECTED BY THE OWNER'S REPRESENTATIVE. BED EDGE LINES SHALL BE A DEPICTED ON THE DRAWINGS. 3.18 WATERING A.THE CONTRACTOR SHALL BE FULLY RESPONSIBLE TO ENSURE THAT ADEQUATE WATER IS PROVIDED TO ALL PLANTS FROM THE POINT OF INSTALLATION UNTIL THE DATE OF SUBSTANTIAL COMPLETION ACCEPTANCE. THE CONTRACTOR SHALL ADJUST THE AUTOMATIC IRRIGATION SYSTEM, IF AVAILABLE, AND APPLY ADDITIONAL OR ADJUST FOR LESS WATER USING HOSES AS REQUIRED. B.HAND WATER ROOT BALLS OF ALL PLANTS TO ASSURE THAT THE ROOT BALLS HAVE MOISTURE ABOVE WILT POINT AND BELOW FIELD CAPACITY. TEST THE MOISTURE CONTENT IN EACH ROOT BALL AND THE SOIL OUTSIDE THE ROOT BALL TO DETERMINE THE WATER CONTENT. 3.19 CLEAN-UP A.DURING INSTALLATION, KEEP THE SITE FREE OF TRASH, PAVEMENTS REASONABLY CLEAN AND WORK AREA IN AN ORDERLY CONDITION AT THE END OF EACH DAY. REMOVE TRASH AND DEBRIS IN CONTAINERS FROM THE SITE NO LESS THAN ONCE A WEEK. 1.IMMEDIATELY CLEAN UP ANY SPILLED OR TRACKED SOIL, FUEL, OIL, TRASH OR DEBRIS DEPOSITED BY THE CONTRACTOR FROM ALL SURFACES WITHIN THE PROJECT OR ON PUBLIC RIGHT OF WAYS AND NEIGHBORING PROPERTY. B.ONCE INSTALLATION IS COMPLETE, WASH ALL SOIL FROM PAVEMENTS AND OTHER STRUCTURES. ENSURE THAT MULCH IS CONFINED TO PLANTING BEDS AND THAT ALL TAGS AND FLAGGING TAPE ARE REMOVED FROM THE SITE. THE OWNER'S REPRESENTATIVE'S SEALS ARE TO REMAIN ON THE TREES AND REMOVED AT THE END OF THE WARRANTY PERIOD. C.MAKE ALL REPAIRS TO GRADES, RUTS, AND DAMAGE BY THE PLANT INSTALLER TO THE WORK OR OTHER WORK AT THE SITE. D.REMOVE AND DISPOSE OF ALL EXCESS PLANTING SOIL, SUBSOIL, MULCH, PLANTS, PACKAGING, AND OTHER MATERIAL BROUGHT TO THE SITE BY THE CONTRACTOR. 3.20 PROTECTION DURING CONSTRUCTION A.THE CONTRACTOR SHALL PROTECT PLANTING AND RELATED WORK AND OTHER SITE WORK FROM DAMAGE DUE TO PLANTING OPERATIONS, OPERATIONS BY OTHER CONTRACTORS OR TRESPASSERS. MAINTAIN PROTECTION DURING INSTALLATION UNTIL SUBSTANTIAL COMPLETION ACCEPTANCE. TREAT, REPAIR OR REPLACE DAMAGED WORK IMMEDIATELY. B.DAMAGE DONE BY THE CONTRACTOR, OR ANY OF THEIR SUB-CONTRACTORS TO EXISTING OR INSTALLED PLANTS, OR ANY OTHER PARTS OF THE WORK OR EXISTING FEATURES TO REMAIN, INCLUDING ROOTS, TRUNK OR BRANCHES OF LARGE EXISTING TREES, SOIL, PAVING, UTILITIES, LIGHTING, IRRIGATION, OTHER FINISHED WORK AND SURFACES INCLUDING THOSE ON ADJACENT PROPERTY, SHALL BE CLEANED, REPAIRED OR REPLACED BY THE CONTRACTOR AT NO EXPENSE TO THE OWNER. THE OWNER'S REPRESENTATIVE SHALL DETERMINE WHEN SUCH CLEANING, REPLACEMENT OR REPAIR IS SATISFACTORY. 3.21 PLANT MAINTENANCE PRIOR TO SUBSTANTIAL COMPLETION ACCEPTANCE A.DURING THE PROJECT WORK PERIOD AND PRIOR TO SUBSTANTIAL COMPLETION ACCEPTANCE, THE CONTRACTOR SHALL MAINTAIN ALL PLANTS. B.MAINTENANCE DURING THE PERIOD PRIOR TO SUBSTANTIAL COMPLETION ACCEPTANCE SHALL CONSIST OF PRUNING, WATERING, CULTIVATING, WEEDING, MULCHING, REMOVAL OF DEAD MATERIAL, REPAIRING AND REPLACING OF TREE STAKES, TIGHTENING AND REPAIRING OF GUYS, REPAIRING AND REPLACING OF DAMAGED TREE WRAP MATERIAL, RESETTING PLANTS TO PROPER GRADES AND UPRIGHT POSITION, AND FURNISHING AND APPLYING SUCH SPRAYS AS ARE NECESSARY TO KEEP PLANTINGS REASONABLY FREE OF DAMAGING INSECTS AND DISEASE, AND IN HEALTHY CONDITION. THE THRESHOLD FOR APPLYING INSECTICIDES AND HERBICIDE SHALL FOLLOW ESTABLISHED INTEGRATED PEST MANAGEMENT (IPM) PROCEDURES. MULCH AREAS SHALL BE KEPT REASONABLY FREE OF WEEDS, GRASS. 3.22 SUBSTANTIAL COMPLETION ACCEPTANCE A.UPON WRITTEN NOTICE FROM THE CONTRACTOR, THE OWNERS REPRESENTATIVE SHALL REVIEW THE WORK AND MAKE A DETERMINATION IF THE WORK IS SUBSTANTIALLY COMPLETE. 1.NOTIFICATION SHALL BE AT LEAST 7 DAYS PRIOR TO THE DATE THE CONTRACTOR IS REQUESTING THE REVIEW. B.THE DATE OF SUBSTANTIAL COMPLETION OF THE PLANTING SHALL BE THE DATE WHEN THE OWNER'S REPRESENTATIVE ACCEPTS THAT ALL WORK IN PLANTING, PLANTING SOIL, AND IRRIGATION INSTALLATION SECTIONS IS COMPLETE. C.THE PLANT WARRANTY PERIOD BEGINS AT DATE OF WRITTEN NOTIFICATION OF SUBSTANTIAL COMPLETION FROM THE OWNER'S REPRESENTATIVE. THE DATE OF SUBSTANTIAL COMPLETION MAY BE DIFFERENT THAN THE DATE OF SUBSTANTIAL COMPLETION FOR THE OTHER SECTIONS OF THE PROJECT. 3.23 MAINTENANCE DURING THE WARRANTY PERIOD BY OTHERS A.AFTER SUBSTANTIAL COMPLETION ACCEPTANCE, THE CONTRACTOR SHALL MAKE SUFFICIENT SITE VISITS TO OBSERVE THE OWNER'S MAINTENANCE AND BECOME AWARE OF PROBLEMS WITH THE MAINTENANCE IN TIME TO REQUEST CHANGES, UNTIL THE DATE OF END OF WARRANTY FINAL ACCEPTANCE. 1.NOTIFY THE OWNER'S REPRESENTATIVE IN WRITING IF MAINTENANCE, INCLUDING WATERING, IS NOT SUFFICIENT TO MAINTAIN PLANTS IN A HEALTHY CONDITION. SUCH NOTIFICATION MUST BE MADE IN A TIMELY PERIOD SO THAT THE OWNER'S REPRESENTATIVE MAY TAKE CORRECTIVE ACTION. A.NOTIFICATION MUST DEFINE THE MAINTENANCE NEEDS AND DESCRIBE ANY CORRECTIVE ACTION REQUIRED. 2.IN THE EVENT THAT THE CONTRACTOR FAILS TO VISIT THE SITE AND OR NOTIFY, IN WRITING, THE OWNER'S REPRESENTATIVE OF MAINTENANCE NEEDS, LACK OF MAINTENANCE SHALL NOT BE USED AS GROUNDS FOR VOIDING OR MODIFYING THE PROVISIONS OF THE WARRANTY. 3.24 MAINTENANCE DURING THE WARRANTY PERIOD BY THE PLANT INSTALLER A.DURING THE WARRANTY PERIOD, PROVIDE ALL MAINTENANCE FOR ALL PLANTINGS TO KEEP THE PLANTS IN A HEALTHY STATE AND THE PLANTING AREAS CLEAN AND NEAT. B.GENERAL REQUIREMENTS: 1.ALL WORK SHALL BE UNDERTAKEN BY TRAINED PLANTING CREWS UNDER THE SUPERVISION OF A FOREMAN WITH A MINIMUM OF 5 YEARS EXPERIENCE SUPERVISING COMMERCIAL PLANT MAINTENANCE CREWS. 2.ALL CHEMICAL AND FERTILIZER APPLICATIONS SHALL BE MADE BY LICENSED APPLICATORS FOR THE TYPE OF CHEMICALS TO BE USED. ALL WORK AND CHEMICAL USE SHALL COMPLY WITH ALL APPLICABLE LOCAL, PROVINCIAL AND FEDERAL REQUIREMENTS. 3.ASSURE THAT HOSES AND WATERING EQUIPMENT AND OTHER MAINTENANCE EQUIPMENT DOES NOT BLOCK PATHS OR BE PLACED IN A MANNER THAT MAY CREATE TRIPPING HAZARDS. USE STANDARD SAFETY WARNING BARRIERS AND OTHER PROCEDURES TO MAINTAIN THE SITE IN A SAFE MANNER FOR VISITORS AT ALL TIMES. 4.ALL WORKERS SHALL WEAR REQUIRED SAFETY EQUIPMENT AND APPAREL APPROPRIATE FOR THE TASKS BEING UNDERTAKEN. 5.THE CONTRACTOR SHALL NOT STORE MAINTENANCE EQUIPMENT AT THE SITE AT TIMES WHEN THEY ARE NOT IN USE UNLESS AUTHORIZED IN WRITING BY THE OWNER'S REPRESENTATIVE. 6.MAINTENANCE VEHICLES SHALL NOT PARK ON THE SITE INCLUDING WALKS AND LAWN AREAS AT ANY TIME WITHOUT THE OWNER'S REPRESENTATIVE'S WRITTEN PERMISSION. 7.MAINTAIN A DETAILED LOG OF ALL MAINTENANCE ACTIVITIES INCLUDING TYPES OF TASKS, DATE OF TASK, TYPES AND QUANTITIES OF MATERIALS AND PRODUCTS USED, WATERING TIMES AND AMOUNTS, AND NUMBER OF EACH CREW. PERIODICALLY REVIEW THE LOGS WITH THE OWNER'S REPRESENTATIVE, AND SUBMIT A COPY OF THE LOGS AT THE END OF EACH YEAR OF THE MAINTENANCE AGREEMENT. 8.MEET WITH THE OWNER'S REPRESENTATIVE A MINIMUM OF THREE TIMES A YEAR TO REVIEW THE PROGRESS AND DISCUSS ANY CHANGES THAT ARE NEEDED IN THE MAINTENANCE PROGRAM. AT THE END OF THE WARRANTY PERIOD ATTEND A HAND OVER MEETING TO FORMALLY TRANSFER THE RESPONSIBILITIES OF MAINTENANCE TO THE OWNER'S REPRESENTATIVE. PROVIDE ALL INFORMATION ON PAST MAINTENANCE ACTIVITIES AND PROVIDE A LIST OF CRITICAL TASKS THAT WILL BE NEEDED OVER THE NEXT 12 MONTHS. PROVIDE ALL MAINTENANCE LOGS AND SOIL TEST DATA. MAKE THE CONTRACTOR'S SUPERVISOR AVAILABLE FOR A MINIMUM OF ONE YEAR AFTER THE END OF THE WARRANTY PERIOD TO ANSWER QUESTIONS ABOUT PAST MAINTENANCE. C.PROVIDE THE FOLLOWING MAINTENANCE TASKS: 1.WATERING; PROVIDE ALL WATER REQUIRED TO KEEP SOIL WITHIN AND AROUND THE ROOT BALLS AT OPTIMUM MOISTURE CONTENT FOR PLANT GROWTH. a.MAINTAIN ALL WATERING SYSTEMS AND EQUIPMENT AND KEEP THEM OPERATIONAL. b.MONITOR SOIL MOISTURE TO PROVIDE SUFFICIENT WATER. CHECK SOIL MOISTURE AND ROOT BALL MOISTURE WITH A SOIL MOISTURE METER ON A REGULAR BASIS AND RECORD MOISTURE READINGS. DO NOT OVER WATER. 2.SOIL NUTRIENT LEVELS: TAKE A MINIMUM OF 4 SOIL SAMPLES FROM AROUND THE SITE IN THE SPRING AND FALL AND HAVE THEM TESTED BY AN ACCREDITED AGRICULTURAL SOIL TESTING LAB FOR CHEMICAL COMPOSITION OF PLANT REQUIRED NUTRIENTS, PH, SALT AND % ORGANIC MATTER. TEST RESULTS SHALL INCLUDE LABORATORY RECOMMENDATIONS FOR NUTRIENT APPLICATIONS. APPLY FERTILIZERS AT RATES RECOMMENDED BY THE SOIL TEST. a.MAKE ANY OTHER SOIL TEST AND/OR PLANT TISSUE TEST THAT MAY BE INDICATED BY PLANT CONDITIONS THAT MAY NOT BE RELATED TO SOIL NUTRIENT LEVELS SUCH AS SOIL CONTAMINATED BY OTHER CHEMICALS OR LACK OF CHEMICAL UPTAKE BY THE PLANT. 3.PLANT PRUNING: REMOVE CROSS OVER BRANCHING, SHORTEN OR REMOVE DEVELOPING CO DOMINANT LEADERS, DEAD WOOD AND WINTER-DAMAGED BRANCHES. UNLESS DIRECTED BY THE OWNER'S REPRESENTATIVE, DO NOT SHEAR PLANTS OR MAKE HEADING CUTS. 4.RESTORE PLANTS: RESET ANY PLANTS THAT HAVE SETTLED OR ARE LEANING AS SOON AS THE CONDITION IS NOTICED. 5.GUYING AND STAKING: MAINTAIN PLANT GUYS IN A TAUGHT POSITION. REMOVE TREE GUYS AND STAKING AFTER THE FIRST FULL GROWING SEASON UNLESS DIRECTED BY OWNER'S REPRESENTATIVE. 6.WEED CONTROL: KEEP ALL BEDS FREE OF WEEDS. HAND-REMOVE ALL WEEDS AND ANY PLANTS THAT DO NOT APPEAR ON THE PLANTING PLAN. CHEMICAL WEED CONTROL IS PERMITTED ONLY WITH THE APPROVAL OF THE OWNER'S REPRESENTATIVE. SCHEDULE WEEDING AS NEEDED BUT NOT LESS 12 TIMES PER YEAR. 7.TRASH REMOVAL: REMOVE ALL TRASH AND DEBRIS FROM ALL PLANTING BEDS AND MAINTAIN THE BEDS IN A NEAT AND TIDY APPEARANCE. THE NUMBER OF TRASH AND DEBRIS REMOVAL VISITS SHALL BE NO LESS THAN 12 TIMES PER YEAR AND MAY COINCIDE WITH OTHER MAINTENANCE VISITS. 8.PLANT PEST CONTROL: MAINTAIN DISEASE, INSECTS AND OTHER PESTS AT MANAGEABLE LEVELS. MANAGEABLE LEVELS SHALL BE DEFINED AS DAMAGE TO PLANTS THAT MAY BE NOTICEABLE TO A PROFESSIONAL BUT NOT TO THE AVERAGE PERSON. USE LEAST INVASIVE METHODS TO CONTROL PLANT DISEASE AND INSECT OUTBREAKS. D.THE OWNER'S REPRESENTATIVE MUST APPROVE IN ADVANCE THE USE OF ALL CHEMICAL PESTICIDE APPLICATIONS. 1.PLANT REPLACEMENT: REPLACE ALL PLANTS THAT ARE DEFECTIVE AS DEFINED IN THE WARRANTY PROVISIONS, AS SOON AS THE PLANT DECLINE IS OBVIOUS AND IN SUITABLE WEATHER AND SEASON FOR PLANTING AS OUTLINED IN ABOVE SECTIONS. PLANTS THAT BECOME DEFECTIVE DURING THE MAINTENANCE PERIOD SHALL BE COVERED AND REPLACED UNDER THE WARRANTY PROVISIONS. 2.MULCH: REFRESH MULCH ONCE A YEAR TO MAINTAIN COMPLETE COVERAGE BUT DO NOT OVER MULCH. AT NO TIME SHALL THE OVERALL MULCH THICKNESS BE GREATER THAT 4 INCHES. DO NOT APPLY MULCH WITHIN 6 INCHES OF THE TRUNKS OR STEMS OF ANY PLANTS. REPLACEMENT MULCH SHALL MEET THE REQUIREMENTS OF THE ORIGINAL APPROVED MATERIAL. MULCH SHALL BE NO MORE THAN ONE INCH ON TOP OF THE ROOT BALL SURFACE. 3.BED EDGING: CHECK AND MAINTAIN EDGES BETWEEN MULCH AND LAWN AREAS IN SMOOTH NEAT LINES AS ORIGINALLY SHOWN ON THE DRAWINGS. 4.LEAF, FRUIT AND OTHER PLANT DEBRIS REMOVAL: REMOVE FALL LEAF, SPENT FLOWERS, FRUIT AND PLANT PART ACCUMULATIONS FROM BEDS AND PAVED SURFACES. MAINTAIN ALL SURFACE WATER DRAINS FREE OF DEBRIS. DEBRIS REMOVAL SHALL BE UNDERTAKEN AT EACH VISIT TO WEED OR PICK UP TRASH IN BEDS. 5.DAMAGE FROM SITE USE: REPAIR OF DAMAGE BY SITE VISITORS AND EVENTS, BEYOND NORMAL WEAR, ARE NOT PART OF THIS MAINTENANCE. THE OWNER'S REPRESENTATIVE MAY REQUEST THAT THE CONTRACTOR REPAIR DAMAGE BEDS OR PLANTINGS FOR AN ADDITIONAL COST. ALL ADDITIONAL WORK SHALL BE APPROVED IN ADVANCE BY THE OWNER'S REPRESENTATIVE. 3.25 END OF WARRANTY FINAL ACCEPTANCE / MAINTENANCE OBSERVATION A.AT THE END OF THE WARRANTY AND MAINTENANCE PERIOD THE OWNER'S REPRESENTATIVE SHALL OBSERVE THE WORK AND ESTABLISH THAT ALL PROVISIONS OF THE CONTRACT ARE COMPLETE AND THE WORK IS SATISFACTORY. 1.IF THE WORK IS SATISFACTORY, THE MAINTENANCE PERIOD WILL END ON THE DATE OF THE FINAL OBSERVATION. 2.IF THE WORK IS DEEMED UNSATISFACTORY, THE MAINTENANCE PERIOD WILL CONTINUE AT NO ADDITIONAL EXPENSE TO THE OWNER UNTIL THE WORK HAS BEEN COMPLETED, OBSERVED, AND APPROVED BY THE OWNER'S REPRESENTATIVE. B.FAILURE TO PASS OBSERVATION: IF THE WORK FAILS TO PASS FINAL OBSERVATION, ANY SUBSEQUENT OBSERVATIONS MUST BE RESCHEDULED AS PER ABOVE. THE COST TO THE OWNER FOR ADDITIONAL OBSERVATIONS WILL BE CHARGED TO THE CONTRACTOR AT THE PREVAILING HOURLY RATE OF THE OWNERS REPRESENTATIVE. END OF SECTION 32 9300 2.4 PLANTING SOIL A.PLANTING SOIL AS USED IN THIS SPECIFICATION MEANS THE SOIL AT THE PLANTING SITE, OR IMPORTED AS MODIFIED AND DEFINED IN SPECIFICATION SECTION PLANTING SOIL. IF THERE IS NO PLANTING SOIL SPECIFICATION, THE TERM PLANTING SOIL SHALL MEAN THE SOIL AT THE PLANTING SITE WITHIN THE PLANTING HOLE. B.PLANTING SOIL SHALL BE 2" LAYER OF IMPORTED MIXED SOIL WITH COMPOST FROM LIVING EARTH OR APPROVED EQUAL. 1. CONTACT: PAUL TOMASO, 214.533.6296 2.5 MULCH A.MULCH SHALL BE COARSE, GROUND, FROM HARDWOOD TREES AND WOODY BRUSH SOURCES. THE SIZE RANGE SHALL BE A MINIMUM (LESS THAN 25% OR LESS OF VOLUME) FINE PARTICLES 3/8 INCH OR LESS IN SIZE, AND A MAXIMUM SIZE OF INDIVIDUAL PIECES (LARGEST 20% OR LESS OF VOLUME) SHALL BE APPROXIMATELY 1 TO 1-1/2 INCH IN DIAMETER AND MAXIMUM LENGTH APPROXIMATELY 4 TO 8". PIECES LARGER THAN 8 INCH LONG THAT ARE VISIBLE ON THE SURFACE OF THE MULCH AFTER INSTALLATION SHALL BE REMOVED. 1.IT IS UNDERSTOOD THAT MULCH QUALITY WILL VARY SIGNIFICANTLY FROM SUPPLIER TO SUPPLIER AND REGION TO REGION. THE ABOVE REQUIREMENTS MAY BE MODIFIED TO CONFORM TO THE SOURCE MATERIAL FROM LOCALLY RELIABLE SUPPLIERS AS APPROVED BY THE OWNER'S REPRESENTATIVE. B.SUBMIT SUPPLIER'S PRODUCT SPECIFICATION DATA SHEET AND A ONE GALLON SAMPLE FOR APPROVAL. 2.6 TREE STAKING AND GUYING MATERIAL A.TREE STAKING SHALL BE PER PLANTING DETAILS. B.ARBOR STAKE OR APPROVED EQUAL. 1.MANUFACTURER: WWW.ARBORSTAKES.COM C.SUBMIT MANUFACTURER'S PRODUCT DATA FOR APPROVAL 2.7 CHEMICAL OR BIOLOGICAL ADDITIVES A.PER SOILS TEST RESULTS. 2.8 COMPOST A.LIVING EARTH COMPOST OR APPROVED EQUAL 1.MANUFACTURER: LIVING EARTH: 972-869-4332 2.10 PLANTER POTTING SOIL A.LIVING EARTH CONTAINER POTTING SOIL OR APPROVED EQUAL 1.MANUFACTURER: LIVING EARTH: 972-869-4332 PART 3 EXECUTION 3.1 SITE EXAMINATION A.EXAMINE THE SURFACE GRADES AND SOIL CONDITIONS TO CONFIRM THAT THE REQUIREMENTS OF THE SPECIFICATION SECTION - PLANTING SOIL - AND THE SOIL AND DRAINAGE MODIFICATIONS INDICATED ON THE PLANTING SOIL PLAN AND DETAILS (IF APPLICABLE) HAVE BEEN COMPLETED. NOTIFY THE OWNER'S REPRESENTATIVE IN WRITING OF ANY UNSATISFACTORY CONDITIONS. 3.2 DELIVERY, STORAGE AND HANDLING A.PROTECT MATERIALS FROM DETERIORATION DURING DELIVERY AND STORAGE. ADEQUATELY PROTECT PLANTS FROM DRYING OUT, EXPOSURE OF ROOTS TO SUN, WIND OR EXTREMES OF HEAT AND COLD TEMPERATURES. IF PLANTING IS DELAYED MORE THAN 24 HOURS AFTER DELIVERY, SET PLANTS IN A LOCATION PROTECTED FROM SUN AND WIND. PROVIDE ADEQUATE WATER TO THE ROOT BALL PACKAGE DURING THE SHIPPING AND STORAGE PERIOD. 1.ALL PLANT MATERIALS MUST BE AVAILABLE FOR OBSERVATION PRIOR TO PLANTING. 2.USING A SOIL MOISTURE METER, PERIODICALLY CHECK THE SOIL MOISTURE IN THE ROOT BALLS OF ALL PLANTS TO ASSURE THAT THE PLANTS ARE BEING ADEQUATELY WATERED. VOLUMETRIC SOIL MOISTURE SHALL BE MAINTAINED ABOVE WILTING POINT AND BELOW FIELD CAPACITY FOR THE ROOT BALL SUBSTRATE OR SOIL. B.DO NOT DELIVER MORE PLANTS TO THE SITE THAN THERE IS SPACE WITH ADEQUATE STORAGE CONDITIONS. PROVIDE A SUITABLE REMOTE STAGING AREA FOR PLANTS AND OTHER SUPPLIES. 1.THE OWNER'S REPRESENTATIVE OR CONTRACTOR SHALL APPROVE THE DURATION, METHOD AND LOCATION OF STORAGE OF PLANTS. C.PROVIDE PROTECTIVE COVERING OVER ALL PLANTS DURING TRANSPORTING. 3.3 PLANTING SEASON A.PLANTING SHALL ONLY BE PERFORMED WHEN WEATHER AND SOIL CONDITIONS ARE SUITABLE FOR PLANTING THE MATERIALS SPECIFIED IN ACCORDANCE WITH LOCALLY ACCEPTED PRACTICE BELOW UNLESS OTHERWISE APPROVED IN WRITING BY THE OWNER'S REPRESENTATIVE. IN THE EVENT THAT THE CONTRACTOR REQUEST PLANTING OUTSIDE THE DATES OF THE PLANTING SEASON, APPROVAL OF THE REQUEST DOES NOT CHANGE THE REQUIREMENTS OF THE WARRANTY. 3.4 ADVERSE WEATHER CONDITIONS A.NO PLANTING SHALL TAKE PLACE DURING EXTREMELY HOT, DRY, WINDY OR FREEZING WEATHER. 3.5 COORDINATION WITH PROJECT WORK A.THE CONTRACTOR SHALL COORDINATE WITH ALL OTHER WORK THAT MAY IMPACT THE COMPLETION OF THE WORK. B.PRIOR TO THE START OF WORK, PREPARE A DETAILED SCHEDULE OF THE WORK FOR COORDINATION WITH OTHER TRADES. C.COORDINATE THE RELOCATION OF ANY IRRIGATION LINES, HEADS OR THE CONDUITS OF OTHER UTILITY LINES THAT ARE IN CONFLICT WITH TREE LOCATIONS. ROOT BALLS SHALL NOT BE ALTERED TO FIT AROUND LINES. NOTIFY THE OWNER'S REPRESENTATIVE OF ANY CONFLICTS ENCOUNTERED. 3.6 LAYOUT AND PLANTING SEQUENCE A.RELATIVE POSITIONS OF ALL PLANTS AND TREES ARE SUBJECT TO APPROVAL OF THE OWNER'S REPRESENTATIVE. B.NOTIFY THE OWNER'S REPRESENTATIVE, ONE (1) WEEK PRIOR TO LAYOUT. LAYOUT ALL INDIVIDUAL TREE AND SHRUB LOCATIONS. PLACE PLANTS ABOVE SURFACE AT PLANTING LOCATION OR PLACE A LABELED STAKE AT PLANTING LOCATION. LAYOUT BED LINES WITH PAINT FOR THE OWNER'S REPRESENTATIVE'S APPROVAL. SECURE THE OWNER'S REPRESENTATIVE'S ACCEPTANCE BEFORE DIGGING AND START OF PLANTING WORK. C.WHEN APPLICABLE, PLANT TREES BEFORE OTHER PLANTS ARE INSTALLED. D.IT IS UNDERSTOOD THAT PLANTS ARE NOT PRECISE OBJECTS AND THAT MINOR ADJUSTMENTS IN THE LAYOUT WILL BE REQUIRED AS THE PLANTING PLAN IS CONSTRUCTED. THESE ADJUSTMENTS MAY NOT BE APPARENT UNTIL SOME OR ALL OF THE PLANTS ARE INSTALLED. MAKE ADJUSTMENTS AS REQUIRED BY THE OWNER'S REPRESENTATIVE INCLUDING RELOCATING PREVIOUSLY INSTALLED PLANTS. 3.7 SOIL PROTECTION DURING PLANT DELIVERY AND INSTALLATION A.PROTECT SOIL FROM COMPACTION DURING THE DELIVERY OF PLANTS TO THE PLANTING LOCATIONS, DIGGING OF PLANTING HOLES AND INSTALLING PLANTS. 1.WHERE POSSIBLE DELIVER AND PLANT TREES THAT REQUIRE THE USE OF HEAVY MECHANIZED EQUIPMENT PRIOR TO FINAL SOIL PREPARATION AND TILLING. WHERE POSSIBLE, RESTRICT THE DRIVING LANES TO ONE AREA INSTEAD OF DRIVING OVER AND COMPACTING A LARGE AREA OF SOIL. 2.TILL TO A DEPTH OF 6 INCHES, ALL SOIL THAT HAS BEEN DRIVEN OVER DURING THE INSTALLATION OF PLANTS. 3.8 SOIL MOISTURE A.VOLUMETRIC SOIL MOISTURE LEVEL, IN BOTH THE PLANTING SOIL AND THE ROOT BALLS OF ALL PLANTS, PRIOR TO, DURING AND AFTER PLANTING SHALL BE ABOVE PERMANENT WILTING POINT AND BELOW FIELD CAPACITY FOR EACH TYPE OF SOIL TEXTURE WITHIN THE FOLLOWING RANGES. SOIL TYPE PERMANENT WILTING POINT FIELD CAPACITY SAND, LOAMY SAND, SANDY LOAM 5 - 8% 12-18% LOAM, SANDY CLAY, SANDY CLAY LOAM 14 - 25% 27-36% CLAY LOAM, SILT LOAM 11 - 22% 31 - 36% SILTY CLAY, SILTY CLAY LOAM 22 - 27% 38 - 41% 1.VOLUMETRIC SOIL MOISTURE SHALL BE MEASURED WITH A DIGITAL MOISTURE METER. THE METER SHALL BE THE DIGITAL SOIL MOISTURE METER, DSMM500 BY GENERAL SPECIALTY TOOLS AND INSTRUMENTS, OR APPROVED EQUIVALENT. B.THE CONTRACTOR SHALL CONFIRM THE SOIL MOISTURE LEVELS WITH A MOISTURE METER. IF THE MOISTURE IS TOO HIGH, SUSPEND PLANTING OPERATIONS UNTIL THE SOIL MOISTURE DRAINS TO BELOW FIELD CAPACITY. 3.9 INSTALLATION OF PLANTS: GENERAL A.OBSERVE EACH PLANT AFTER DELIVERY AND PRIOR TO INSTALLATION FOR DAMAGE OF OTHER CHARACTERISTICS THAT MAY CAUSE REJECTION OF THE PLANT. NOTIFY THE OWNER'S REPRESENTATIVE OF ANY CONDITION OBSERVED. B.NO MORE PLANTS SHALL BE DISTRIBUTED ABOUT THE PLANTING BED AREA THAN CAN BE PLANTED AND WATERED ON THE SAME DAY. C.THE ROOT SYSTEM OF EACH PLANT, REGARDLESS OF ROOT BALL PACKAGE TYPE, SHALL BE OBSERVED BY THE CONTRACTOR, AT THE TIME OF PLANTING TO CONFIRM THAT THE ROOTS MEET THE REQUIREMENTS FOR PLANT ROOT QUALITY IN PART 2 PRODUCTS: PLANTS GENERAL: PLANT QUALITY. THE CONTRACTOR SHALL UNDERTAKE AT THE TIME OF PLANTING, ALL MODIFICATIONS TO THE ROOT SYSTEM REQUIRED BY THE OWNER'S REPRESENTATIVE TO MEET THESE QUALITY STANDARDS. 35 BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643BDMLCLCSEPTEMBER 2024SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASLANDSCAPE ARCHITECT KIMLEY-HORN & ASSOCIATES, INC. 10101 REUNION PLACE, SUITE 400 SAN ANTONIO, TX 78216 PH. (726) 610-3728 CONTACT: BLAINE MIKULIK, PLA, LI 3486 BLAINE D. MIKULIK FOR REVIEW ONLY R.L.A. L.A. No.DATE 09/10/2024 Not for construction or permit purposes.LANDSCAPE SPECIFICATIONSLP 2.03 SECTION 32 9210: LAWNS AND GRASSES PART 1 -GENERAL 1.1 SECTION INCLUDES A.FURNISH ALL LABOR, MATERIAL, EQUIPMENT RELATED SERVICES AND SUPERVISION NECESSARY FOR OR INCIDENTAL TO THE INSTALLATION OF THE LAWNS AND GRASSES AS SHOWN OR INDICATED ON THE DRAWINGS AND/OR AS SPECIFIED. B.WORK INCLUDED: 1.SOIL PREPARATION AND FINE GRADING. 2.FERTILIZATION. 3.GRASS SODDING 4.SEEDING 1.2 SUBMITTALS A.DELIVERY RECEIPTS AND INVOICES: SUBMIT ORIGINAL DELIVERY RECEIPTS AND INVOICES FOR MATERIALS USED. B.PRODUCT DATA: SUBMIT SAMPLE LABEL OR SPECIFICATION OF FERTILIZER. C.CERTIFICATE: SUBMIT STATE CERTIFICATE STATING VARIETY AND PURITY OF GRASS SOD. D.SOIL FERTILITY TEST REPORTS: 1.SUBMIT ANALYSIS, TEST RESULTS AND CORRECTIVE RECOMMENDATIONS TO THE OWNER'S REPRESENTATIVE. 2.ONE TEST PER MEDIAN IS REQUIRED OF EXISTING SOIL TAKEN AT DIFFERENT LOCATIONS ON THE PROJECT SITE AS DIRECTED BY THE OWNER'S REPRESENTATIVE. 1.3 PROTECTION A.PROTECT PAVING SURFACES, CURBS, UTILITIES, PLANT MATERIALS, AND OTHER EXISTING IMPROVEMENTS FROM DAMAGE BY HEAVY EQUIPMENT. B.LOCATE AND STAKE IRRIGATION HEADS, VALVE RISERS AND EQUIPMENT PRIOR TO BEGINNING SOIL PREPARATION WORK. C.DURING WORK AND MAINTENANCE PERIOD, MAINTAIN TOPSOIL IN PLACE AT ESTABLISHED GRADES. REPLACE TOPSOIL AND GRASS LOSSES DUE TO EROSION. D.PROTECT IN PLACE WORK FROM DAMAGE BY HEAVY EQUIPMENT. PREPARE, GRADE, LEVEL, AND REPLANT DAMAGED AREAS. 1.4 SUBSTANTIAL COMPLETION & PROJECT CLOSEOUT A.A CERTIFICATE OF SUBSTANTIAL COMPLETION WILL BE ISSUED WHEN THE WORK PERFORMED UNDER THE CONTRACT HAS BEEN REVIEWED AND FOUND, TO THE OWNER'S REPRESENTATIVE'S BEST KNOWLEDGE, INFORMATION, AND BELIEF, TO BE SUBSTANTIALLY COMPLETE. SUBSTANTIAL COMPLETION IS THE STAGE IN THE PROGRESS OF THE WORK WHEN THE WORK OR DESIGNATED PORTION THEREOF IS SUFFICIENTLY COMPLETE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS SO THE OWNER CAN OCCUPY OR UTILIZE THE WORK FOR ITS INTENDED USE. THE DATE OF SUBSTANTIAL COMPLETION OF THE PROJECT OR PORTION THEREOF IS ALSO THE DATE OF COMMENCEMENT OF APPLICABLE GUARANTEES AS SPECIFIED. B.A LIST OF ITEMS TO BE COMPLETED OR CORRECTED WILL BE ATTACHED TO THE CERTIFICATE OR SUBSTANTIAL COMPLETION. THE FAILURE TO INCLUDE ANY ITEMS ON SUCH LIST DOES NOT ALTER THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLETE ALL WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. C.THE CONTRACTOR WILL COMPLETE OR CORRECT THE WORK ON THE LIST OF ITEMS WITHIN A SPECIFIC NUMBER OF DAYS AS SHOWN ON THE CERTIFICATE OF SUBSTANTIAL COMPLETION. D.UPON COMPLETION AND RE-INSPECTION OF ALL CORRECTED ITEMS LISTED, THE OWNER'S REPRESENTATIVE WILL RECOMMEND TO THE OWNER THAT THE WORK OF THIS SECTION IS READY FOR FINAL ACCEPTANCE. 1.5 QUALITY ASSURANCE A.GENERAL: COMPLY WITH APPLICABLE FEDERAL, STATE, COUNTY AND LOCAL REGULATIONS GOVERNING LANDSCAPE MATERIALS AND WORK. B.PERSONNEL: EMPLOY ONLY EXPERIENCED PERSONNEL WHO ARE FAMILIAR WITH THE REQUIRED WORK. PROVIDE SUPERVISION BY A QUALIFIED FOREMAN. 1.6 GUARANTEE A.GUARANTEE LAWNS AND GRASSES FOR ONE YEAR AFTER DATE OF FINAL ACCEPTANCE AT THE END OF THIS GUARANTEE PERIOD, ALL LAWN AND GRASS AREAS WILL HAVE ACHIEVED COVERAGE OF THE SPECIFIED GRASS AT A DENSITY OF 100% COVERAGE, FREE OF WEEDS, UNDESIRABLE GRASS SPECIES, DISEASE, AND INSECTS. REPLACE DEAD MATERIALS AND MATERIALS NOT IN VIGOROUS, THRIVING CONDITION AS SOON AS WEATHER PERMITS AND ON NOTIFICATION BY THE OWNER'S REPRESENTATIVE. B.REPLACE LAWNS AND GRASSES WITH SAME KIND AS ORIGINALLY PLANTED, AT NO COST TO THE OWNER. PROTECT IRRIGATION SYSTEM AND OTHER PIPING, CONDUIT, OR OTHER WORK DURING REPLACEMENT. REPAIR DAMAGE IMMEDIATELY. 1.7 JOB CONDITIONS A.DO NOT INSTALL SOD OR SEED ON SATURATED OR FROZEN SOIL. B.SOD AND SEED INSTALLATION SHALL BE SUBJECT TO SUITABILITY OF THE WEATHER AND OTHER CONDITIONS AFFECTING SOD GROWTH. 1.8 PROGRESS MEETINGS A.CONTRACTOR SHALL ATTEND ALL PROGRESS MEETINGS AS REQUESTED BY THE OWNER'S REPRESENTATIVE DURING INSTALLATION. 1.9 QUANTITY VERIFICATION A.THE BIDDING CONTRACTOR IS RESPONSIBLE FOR THE INCLUSION OF ALL MATERIALS, LABOR AND EQUIPMENT AS OUTLINED IN THE PLANS AND SPECIFICATION. THE PLANT LIST IS PROVIDED TO THE BIDDING CONTRACTOR AS A CONVENIENCE AND THE QUANTITIES ARE APPROXIMATE. VERIFICATION OF ALL QUANTITIES IS THE SOLE RESPONSIBILITY OF THE BIDDING CONTRACTOR. ANY DISCREPANCIES MUST BE REPORTED TO THE OWNER'S REPRESENTATIVE PRIOR TO SUBMITTAL OF BID. PART 2 PRODUCTS 2.1 GRASS A.GENERAL: 1.SOD SHALL BE NURSERY GROWN ON CULTIVATED AGRICULTURAL SOILS. SOD SHALL HAVE BEEN MOWED REGULARLY AND CAREFULLY AND OTHERWISE MAINTAINED FROM PLANTING TO HARVEST. 2.SOD SHALL BE OF SPECIES INDICATED. 3.THICKNESS OF CUT: SOD SHALL BE CUT TO THE SUPPLIER'S STANDARD WIDTH AND LENGTH. MAXIMUM ALLOWABLE DEVIATION FROM STANDARD WIDTHS AND LENGTHS SHALL BE PLUS OR MINUS .25 INCHES ON WIDTH AND PLUS OR MINUS 5% ON LENGTH. 4.BROKEN STRIPS AND TORN OR UNEVEN ENDS WILL NOT BE ACCEPTED. 5.STRENGTH OF SOD STRIPS: SOD STRIPS SHALL BE STRONG ENOUGH TO SUPPORT THEIR OWN WEIGHT AND RETAIN THEIR SIZE AND SHAPE IF SUSPENDED VERTICALLY WHEN GRASPED IN THE UPPER 10% OF THE SECTION. 6.MOISTURE CONTENT: SOD SHALL NOT BE HARVESTED OR TRANSPLANTED WHEN MOISTURE CONTENT (EXCESSIVELY WET OR DRY) MAY ADVERSELY AFFECT ITS SURVIVAL. SOD SHALL BE STORED IN A COMPACT GROUP TO PREVENT DRYING OUT OR FREEZING. 7.TIME LIMITATIONS: SOD SHALL BE HARVESTED, DELIVERED, AND TRANSPLANTED WITHIN A 30-HOUR PERIOD UNLESS A SUITABLE PRESERVATION METHOD IS APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO DELIVERY. SOD NOT TRANSPLANTED WITHIN THIS PERIOD SHALL BE INSPECTED FOR APPROVAL BY THE OWNER'S REPRESENTATIVE PRIOR TO ITS INSTALLATION. 8.THATCH: SOD SHALL BE FREE OF THATCH. 9.DISEASES. NEMATODES AND INSECTS: SOD SHALL BE FREE OF DISEASES, NEMATODES, AND SOIL-BORNE INSECTS. 10.WEEDS: SOD SHALL BE FREE OF OBJECTIONABLE GRASSY AND BROADLEAF WEEDS. B.SOD: 1.CYNODON DACTYLON (COMMON BERMUDA GRASS) C.SEED: 1.SEED: FRESH, CLEAN, AND NEW CROP SEED MIXTURE. A. COMPOSED OF THE FOLLOWING VARIETIES, MIXED TO THE SPECIFIED PROPORTIONS BY WEIGHT, AND TESTED TO MINIMUM PERCENTAGES OF PURITY AND GERMINATION. SHALL BE FREE OF: POA ANNUA, BENT GRASS, AND NOXIOUS WEED SEED. B. RATE: 2 - 3 POUNDS PER 1,000 SQUARE FEET. 2.TYPES: TYPES PARTS PURITY GERMINATION COMMON BERMUDA 100% 95% 95% 2.2 MULCH A.HYDRO-MULCH: CELLULOSE FIBER MULCH SHALL CONSIST OF SPECIALLY PREPARED CELLULOSE PROCESSED INTO A UNIFORM FIBROUS PHYSICAL STATE. THE FIBER MULCH, INCLUDING DYE, SHALL CONTAIN NO GERMINATION OR GROWTH INHIBITING FACTORS. THE MULCH MATERIAL SHALL BE MANUFACTURED AND PROCESSED IN SUCH A MANNER THAT THE CELLULOSE FIBER MULCH WILL REMAIN IN UNIFORM SUSPENSION IN WATER UNDER AGITATION AND WILL BLEND WITH SEED, FERTILIZER, AND OTHER ADDITIVES TO FORM A HOMOGENEOUS SLURRY. THE MULCH SHALL COVER AND HOLD GRASS SEED IN CONTACT WITH THE SOIL WITH OUT INHIBITING THE GROWTH OF THE GRASS SEEDLINGS. 2.3 TOPSOIL A.GENERAL TOPSOIL 1.REFERENCE PLANTING SOIL PLANS. 2.4 SEEDING ACCESSORIES A.WEED KILLER: IF NECESSARY IN THE OPINION OF THE LANDSCAPE ARCHITECT, AN APPLICATION OF BROADLEAF WEED KILLER MAY BE APPLIED PRIOR TO FINAL ACCEPTANCE. ORTHO WEED-B-GONE OR EQUAL AT A RATE OF 3 TEASPOONS/GALLON OF WATER OR 3 CUPS (25 OZ.) PER 50 GALLONS OF WATER SHALL BE APPLIED AT LEAST 48 HOURS BEFORE WATERING OR ANTICIPATED RAINFALL. B.MULCH TACKIFIER APPLY LIQUID TACKIFIER UNIFORMLY AT THE RATE OF 60 GALLONS PER ACRE, IF NEEDED, TO KEEP STRAW MULCH IN PLACE. C.GROUND LIMESTONE GROUND LIMESTONE SHALL CONTAIN NOT LESS THAN 85% OF TOTAL CARBONATES AND GROUND TO SUCH FINENESS THAT 50% WILL PASS THROUGH A NO. 100 MESH SIEVE, AND 90% WILL PASS THROUGH A NO. 20 MESH SIEVE. 2.5 FERTILIZER A.GENERAL: 1.FERTILIZER SHALL BE COMMERCIAL PRODUCT, UNIFORM IN COMPOSITION, FREE FLOWING, AND SUITABLE FOR APPLICATION WITH APPROVED EQUIPMENT. 2.DELIVER FERTILIZER TO SITE IN FULLY LABELED ORIGINAL CONTAINERS. 3.FERTILIZER WHICH HAS BEEN EXPOSED TO HIGH HUMIDITY AND MOISTURE HAS BECOME CAKED OR OTHERWISE DAMAGED, MAKING IT UNSUITABLE FOR USE, WILL NOT BE ACCEPTABLE. B.INITIAL APPLICATION: 1.17% NITROGEN 2.17% PHOSPHORIC ACID 3.17% POTASH C.SECOND APPLICATION: 1.21% NITROGEN 2.0% PHOSPHORIC ACID 3.0% POTASH PART 3 EXECUTION 3.1 GENERAL A. EXECUTE GRASS PLANTING OPERATIONS ACROSS SLOPE AND PARALLEL TO FINISHED GRADE CONTOURS. 3.2 PRE-PLANT WEED CONTROL A.IRRIGATED AND NON-IRRIGATED GRASS AREAS: 1.IF GRASSY OR BROADLEAF WEEDS EXIST ON SITE AT THE BEGINNING OF WORK, SPRAY WITH A NON-SELECTIVE SYSTEMIC CONTACT HERBICIDE, AS RECOMMENDED AND APPLIED BY AN APPROVED LICENSED LANDSCAPE PEST CONTROL ADVISOR AND APPLICATOR. LEAVE SPRAYED PLANTS INTACT FOR AT LEAST 15 DAYS TO ALLOW SYSTEMIC KILL. 2.CLEAR AND REMOVE THESE EXISTING WEEDS BY MOWING OR GRUBBING OFF ALL PLANT PARTS AT LEAST 0.25 INCHES BELOW THE SURFACE OF THE SOIL OVER THE ENTIRE AREA TO BE PLANTED. B.IRRIGATED GRASS AREAS ONLY: 1.AFTER IRRIGATION SYSTEM IS OPERATIONAL, APPLY WATER FOR 5 TO 10 DAYS AS NEEDED TO ACHIEVE WEED GERMINATION. APPLY CONTACT HERBICIDES AND WAIT AS NEEDED BEFORE PLANTING. REPEAT AS NEEDED. 2.MAINTAIN LAWN AND GRASS AREAS WEED FREE UNTIL FINAL ACCEPTANCE BY OWNER'S REPRESENTATIVE UTILIZING MECHANICAL AND CHEMICAL TREATMENT. 3.3 SOIL PREPARATION A.TILLAGE: 1.TILLAGE SHALL BE ACCOMPLISHED TO LOOSEN ALL AREAS OF COMPACTED SOIL. WHEN PLACEMENT OF TOPSOIL IS SPECIFIED, TILL COMPACTED AREAS PRIOR TO PLACEMENT. 2.TILL WITH HEAVY DUTY DISC, ROTOTILLER, OR CHISEL-TYPE BREAKING PLOW, CHISELS SET NOT MORE THAN 10 INCHES APART. TILL TO A DEPTH OF 1 TO 3 INCHES. 3.INITIAL TILLAGE SHALL BE DONE IN CROSSING PATTERN FOR DOUBLE COVERAGE THEN FOLLOWED BY A DISC HARROW. B.CLEANING: 1.REMOVE DEBRIS, BUILDING MATERIALS, RUBBISH, WEEDS, AND STONES LARGER THAN 1 INCH IN DIAMETER. 2.USE ROCK PICK OR OTHER MACHINERY TO GATHER SURFACE STONES LARGER THAN 1 INCH IN DIAMETER. C.FINE GRADING: 1.AFTER TILLAGE AND PLACEMENT OF TOPSOIL, LEVEL, FINE GRADE, AND DRAG WITH A WEIGHTED SPIKE HARROW OR FLOAT DRAG. 2.ELIMINATE RUTS, DEPRESSIONS, HUMPS, AND OBJECTIONABLE SOIL CLODS. 3.4 FERTILIZING A.THE FERTILIZER TYPES AND RATES SPECIFIED HEREIN ARE APPLICABLE UNLESS COUNTERMANDED BY THE SOIL FERTILITY TEST CORRECTIVE RECOMMENDATIONS, IN WHICH CASE THEY WILL BE APPLICABLE. B.BERMUDA SODDING: 1.INITIAL APPLICATION: APPLY NO MORE THAN 5 DAYS PRIOR TO COMMENCEMENT OF SODDING OPERATIONS AT A RATE OF 20 POUNDS PER 1,000 SQUARE FEET. INCORPORATE INTO SOIL WITH A CHAIN HARROW. 2.SECOND AND THIRD APPLICATIONS: APPLY EVERY 25 DAYS AFTER SODDING AT A RATE OF 10 POUNDS PER 1,000 SQUARE FEET. 3.IRRIGATE THE AREA WITH A MINIMUM OF .25 INCHES OF WATER TO PROPERLY INCORPORATE THE FERTILIZER INTO THE TURF. 3.5 PLANTING SOD A.WEATHER CONDITIONS: 1.SCHEDULE WORK FOR PERIODS OF FAVORABLE WEATHER. 2.SOD PLACEMENT ON DAYS WHICH, IN THE JUDGMENT OF THE OWNER'S REPRESENTATIVE, ARE TOO HOT, COLD, SUNNY, DRY, OR WINDY FOR OPTIMAL INSTALLATION MAY BE PROHIBITED. B.PLACEMENT PATTERN: 1.THE FIRST ROW SHALL BE LAID IN A STRAIGHT LINE WITH SUBSEQUENT ROWS PARALLEL TO THE FIRST ROW AND TIGHTLY ABUTTING EACH OTHER. 2.LATERAL JOINTS SHALL BE STAGGERED. CARE SHALL BE EXERCISED TO ENSURE THAT THE SOD IS NEITHER STRETCHED NOR OVERLAPPED. JOINTS MUST BE BUTTED TIGHTLY TO PREVENT VOIDS THAT COULD PERMIT AIR TO DRY OUT ROOT. 3.IMMEDIATELY AFTER PLACING, SOD SHALL BE PRESSED FIRMLY INTO CONTACT WITH BED BY TAMPING OR ROLLING TO ELIMINATE AIR POCKETS. FOLLOWING TAMPING, SCREENED TOPSOIL SHALL BE USED TO FILL ALL CRACKS AND EXCESS SOIL SHALL BE WORKED INTO THE SOD WITH RAKES OR OTHER SUITABLE EQUIPMENT. SOD SHALL NOT BE SMOTHERED WITH EXCESS FILL SOIL. 4.ON SLOPES STEEPER THAN 3 TO 1, SOD SHALL BE SECURED BY GALVANIZED PINS, WOOD PEGS OR OTHER METHODS APPROVED BY THE OWNER'S REPRESENTATIVE. 5.IMMEDIATELY AFTER SODDING OPERATIONS HAVE BEEN COMPLETED, THE ENTIRE SURFACE SHALL BE COMPACTED WITH A ROLLER OR OTHER APPROVED EQUIPMENT. THE COMPLETED AREA AFTER SODDING SHALL BE UNIFORMLY EVEN, FIRM, AND TRUE TO FINISHED GRADE LINES. C.WATERING: 1.INITIAL INSTALLATION: WATER MUST BE APPLIED WITHIN 2 HOURS OF EXPOSURE OF THE SOD TO SUN OR WIND. WATER NEWLY LAID SOD UNTIL SATURATION OF THE ENTIRE AREA IS APPARENT. AS A RESULT OF INITIAL IRRIGATION, STANDING WATER MAY BE PRESENT AND MODERATE TO HEAVY RUN OFF MAY OCCUR. CONTINUE TO IRRIGATE DAILY IN SHORTER DURATIONS SO THE ENTIRE AREA STAYS THOROUGHLY WET BUT WITHOUT STANDING WATER. THE LENGTH OF IRRIGATION TIME AND FREQUENCY OF APPLICATIONS WILL VARY AT DIFFERENT LOCATIONS DUE TO WEATHER CONDITIONS AND INDIVIDUAL SITE CHARACTERISTICS. 2.AFTER 7 TO 10 DAYS: CHECK FOR NEW ROOT GROWTH BY LIFTING CORNERS OF SOD BLOCKS. IF CONSISTENT ROOT GROWTH OVER THE ENTIRE SITE IS OBSERVED, WATER APPLICATIONS CAN BE REDUCED TO ONCE EVERY OTHER DAY. 3.AFTER 12 TO 14 DAYS: RECHECK FOR ADDITIONAL ROOTING. IF SOD BLOCKS ARE DIFFICULT TO PULL UP OR ADDITIONAL NEW ROOTS ARE PRESENT ALLOW THE AREA TO DRY TO THE EXTENT THAT MOWING CAN BE PERFORMED. 3.6 SEEDING LAWNS A.SEEDING LIMITS: ALL GROUND AREA WITHIN THE INDICATED PROJECT LIMIT LINES, OR ANY ADDITIONAL AREA WHICH HAS BEEN DISTURBED IN ANY WAY BY THE CONSTRUCTION OPERATIONS, SHALL BE FINE GRADED AND PLANTED IN SEED OR SOD UNLESS OTHERWISE INDICATED ON THE DRAWINGS TO BE COVERED WITH TREES, SHRUBS, STRUCTURE(S), WALKS, ROADS, OR OTHER SURFACED AREAS. B.RESPONSIBILITY: THE CONTRACTOR SHALL UTILIZE ALL SUCH MEASURES AS MAY BE NECESSARY, INCLUDING, BUT NOT LIMITED TO, PROTECTIVE FENCING, SOD, OR EROSION CONTROL NETTING TO PRODUCE A FINISHED CONTINUOUS BLANKET OF TURF OVER ALL AREAS DESIGNATED TO RECEIVE TURF. 1.ANY AREAS EXCEEDING 5:1 SLOPE SHOULD BE TREATED WITH EROSION CONTROL BLANKETS BY CURLEX®, APPROVED EQUAL, OR OTHER EROSION CONTROL METHODS DEEMED NECESSARY BY THE CONTRACTOR TO ESTABLISH A SOLID LAWN AREA. C.FERTILIZER 1.APPLY FERTILIZER TO INDICATED TURF AREAS AT A RATE EQUAL TO 1.0 POUND OF ACTUAL NITROGEN PER 1,000 SQUARE FEET (430 POUNDS OF FERTILIZER PER ACRE). 2.APPLY FERTILIZERS BY MECHANICAL ROTARY OR DROP TYPE DISTRIBUTOR, THOROUGHLY AND EVENLY INCORPORATED INTO SOIL TO A DEPTH OF 3", BY DISCING OR OTHER APPROVED METHOD. FERTILIZE AREAS INACCESSIBLE TO POWER EQUIPMENT WITH HAND TOOLS AND INCORPORATE INTO SOIL. 3.RESTORE PREPARED AREAS TO SPECIFIED CONDITION IF ERODED, SETTLED, OR OTHERWISE DISTURBED, AFTER FINE GRADING AND PRIOR TO SEEDING. D.HYDROSEEDING USE A HYDROMULCHER (SPRAYER) AND APPLY MIXTURE(S) AT THE FOLLOWING RATES. MIX IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 1.LAWNS a.GRASS SEED: PER SEED TYPE. b.FERTILIZER: PER SOIL TEST REPORT RECOMMENDATIONS. 3.7 GRADING A.MAINTAIN EXISTING ESTABLISHED GRADES, PROTECT TRUE AND EVEN DURING OPERATIONS. 3.8 EROSION CONTROL A.DURING WORK AND MAINTENANCE PERIOD, MAINTAIN TOPSOIL IN PLACE AT ESTABLISHED GRADES. REPLACE TOPSOIL AND TURF GRASS LOSSES DUE TO EROSION. 3.9 CLEAN-UP A.REMOVE EXCESS MATERIAL AND DEBRIS FROM SITE. 3.10 MAINTENANCE A.UNTIL FINAL ACCEPTANCE, MAINTAIN LAWN AND GRASS AREAS BY WATERING, MOWING, WEEDING, SPRAYING, CLEANING AND REPLACING AS NECESSARY TO KEEP THE TURF AND GRASS IN A VIGOROUS, HEALTHY CONDITION. 1.WATERING: AS NECESSARY. 2.MOWING: a)MOW NEWLY PLANTED GRASS AREAS WEEKLY AFTER INITIAL GROWTH REACHES 1.5 TO 2 INCHES. 3.WEEDING: REMOVE WEEDS AND FOREIGN GRASS OVER LAWN AND GRASS AREAS AT LEAST ONCE A WEEK. HERBICIDES MAY BE USED ONLY WHEN APPROVED BY THE OWNER'S REPRESENTATIVE. END OF SECTION 329210 36 FINISH FLOOR 100'-0" A B C D E T.O. PANEL 148'-0" T.O. PANEL 142'-0" 4 A7.02 B2 B2 B C P-77P-76P-75P-60P-61P-62P-63P-64P-65P-66P-67P-68P-70 2'-6"2'-0"1'-6"H.M. DOOR AND FRAME, TYP. - PAINT TO MATCH ADJ. WALL COLOR PANEL JOINT, TYP. TEXTURED COATED CONCRETE WALL ALUM. STOREFRONT GLAZING SYSTEM, TYP. ROOF BEYOND REVEALS, TYP.WALL PACK, TYP. TC-03 TC-02 TC-01 TC-04 TC-02 TC-02TC-03 TC-01 FINISH FLOOR 100'-0" T.O. PANEL 148'-0" 12345678910111213 C A A2 A3 A3 B B2 B2 DDDDDD CC DDDDDD E E2 E3 E3 FF F2 F2 F2 F2 CB B2 B2 A A2 A3 A3 P-01P-02P-03P-04P-05P-06P-07P-08P-09P-10P-11P-12P-13P-14P-15P-16P-17P-18P-19P-20P-21P-22P-23P-24P-25 1'-6"1'-6"1'-6"1'-6"ALUM. STOREFRONT CLERESTORY WINDOWS, TYP. H.M. DOOR AND FRAME, TYP. - PAINT TO MATCH ADJ. WALL COLOR TEXTURED COATED CONCRETE WALL PANEL REVEAL, TYP.ROOF BEYOND ALUM. STOREFRONT GLAZING SYSTEM, TYP. TC-01 TC-03 TC-02 TC-04 TC-03 TC-02 TC-02 A5.02 2 A5.02 3 FINISH FLOOR 100'-0" T.O. PANEL 148'-0" ABCDE T.O. PANEL 142'-0" C B2 B2 B P-35 P-34 P-33 P-32 P-31 P-30 P-29 P-28 P-27 P-26P-28 2'-6"2'-0"1'-6"H.M. DOOR AND FRAME, TYP. - PAINT TO MATCH ADJ. WALL COLOR PANEL JOINT, TYP. TEXTURED COATED CONCRETE WALL ALUM. STOREFRONT GLAZING SYSTEM, TYP. ROOF BEYOND P.J.P.J. P.J. P.J. REVEALS, TYP. WALL PACK, TYP. TC-03 TC-01 MTL-02 TC-04 TC-01 TC-02 TC-03 TC-02TC-02 A5.02 1 FINISH FLOOR 100'-0" 1 2 3 4 5 6 7 8 9 10 11 12 13 T.O. PANEL 142'-0" 1 A7.02 2 A7.02 3 A7.02 DDDDDDDD P-59 P-58 P-57 P-56 P-55 P-54 P-53 P-52 P-51 P-50 P-49 P-48 P-47 P-46 P-45 P-44 P-43 P-42 P-41 P-40 P-39 P-38 P-37 P-36 ALUM. STOREFRONT CLERESTORY WINDOWS, TYP. H.M. DOOR AND FRAME, TYP. - PAINT TO MATCH ADJ. WALL COLOR TEXTURED COATED CONCRETE WALL PANEL REVEAL, TYP.9' X 11' PREFINISHED LOUVER, TYP. PREFINISHED GUTTER AND RECESSED DOWNSPOUT, TYP.TC-01 TC-04TC-03 TC-02 WALL PACK, TYP. THE RECORD COPY OF THIS DRAWING IS ON FILE AT THE OFFICES OF: ALLIANCE ARCHITECTS, INC. 1600 N. COLLINS BLVD. SUITE 1000 RICHARDSON, TEXAS 75080 (972) 233-0400 FAX: (972) 233-2259 THIS ELECTRONIC DOCUMENT IS RELEASED FOR THE PURPOSES OF REFERENCE, COORDINATION, AND/OR FACILITY MANAGEMENT UNDER THE AUTHORITY OF: THOMAS M. MAXWELL, REG. #15730 ON . ANY MODIFICATION(S) TO THIS DRAWING SHALL BE IN COMPLIANCE WITH THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS' RULES. © COPYRIGHT 2024 ALLIANCE ARCHITECTS, INC. PROJECT NO.: 1600 N. Collins Blvd., Suite 1000 Richardson, Texas 75080 (972) 233-0400 AllianceArch.com 9/5/2024 3:28:53 PMC:\Users\robertb\Documents\Revit Local Files\Stonelake Skyport Building 1 2024162_NanaBatman89.rvtA5.01 2024162-1 EXTERIOR BUILDING ELEVATIONS800 S ROYAL LANE, COPPELL TX.STONELAKE SKYPORTBUILDING 109/05/2024 Scale:1" = 20'-0"3 SOUTH ELEVATION Scale:1" = 20'-0"1 WEST ELEVATION Scale:1" = 20'-0"4 NORTH ELEVATION Scale:1" = 20'-0"2 EAST ELEVATION DRAWING RECORD DATE DESCRIPTION GL-01 GL-01MATERIAL SCHEDULECOLOR DESCRIPTIONAL-01 Kawneer - Clear Anodized Storefront Anodized AluminumGL-01 Vitro - Solarban 70 Solarblue Tinted GlazingMTL-02 Archifab - Atlas Award Blue Prefabricated Metal Panel CanopyTC-01 SW 6253 Olympus White Texture Coated ConcreteTC-02 SW 7004 Snowbound Texture Coated ConcreteTC-03 SW 7072 Online Texture Coated ConcreteTC-04 SW 6804 Dignity Blue Texture Coated Concrete37 FINISH FLOOR100'-0"T.O. PANEL148'-0"AB2'-6"CBB2B2ALUM. STOREFRONTGLAZING SYSTEM, TYP.TEXTURED COATED CONCRETE WALLPANEL REVEAL, TYP.P-27P-26TC-01TC-03TC-01TC-04TC-02MTL-02MTL-02FINISH FLOOR100'-0"T.O. PANEL148'-0"78CCFF2F2FF2F2EE2E3E3TC-03TC-01TC-04TC-02TC-01MTL-02TC-02TC-03TC-01TC-04ALUM. STOREFRONTGLAZING SYSTEM, TYP.TEXTURED COATED CONCRETE WALLPANEL REVEAL, TYP.P-15P-14P-13P-12P-111'-6"1'-6"FINISH FLOOR100'-0"T.O. PANEL148'-0"31A7.03CBB2B2AA2A3A3P-03P-02P-011'-6"TC-02TC-03TC-01MTL-02MTL-02ALUM. STOREFRONTGLAZING SYSTEM, TYP.TEXTURED COATED CONCRETE WALLPANEL REVEAL, TYP.THE RECORD COPY OF THIS DRAWING IS ON FILE AT THE OFFICES OF:ALLIANCE ARCHITECTS, INC.1600 N. COLLINS BLVD.SUITE 1000RICHARDSON, TEXAS 75080(972) 233-0400FAX: (972) 233-2259THIS ELECTRONIC DOCUMENT IS RELEASED FOR THE PURPOSES OF REFERENCE, COORDINATION, AND/OR FACILITY MANAGEMENT UNDER THE AUTHORITY OF:THOMAS M. MAXWELL, REG. #15730 ON. ANY MODIFICATION(S) TO THIS DRAWING SHALL BE IN COMPLIANCE WITH THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS' RULES. © COPYRIGHT 2024 ALLIANCE ARCHITECTS, INC.PROJECT NO.:1600 N. Collins Blvd., Suite 1000Richardson, Texas 75080(972) 233-0400AllianceArch.com9/5/2024 3:28:54 PMC:\Users\robertb\Documents\Revit Local Files\Stonelake Skyport Building 1 2024162_NanaBatman89.rvtA5.022024162-1ENLARGED BUILDINGELEVATIONS800 S ROYAL LANE, COPPELL TX.STONELAKE SKYPORTBUILDING 109/05/2024Scale:1/8" = 1'-0"1ENLARGED ELEVATION - NORTHScale:1/8" = 1'-0"2ENLARGED ELEVATION - CENTERScale:1/8" = 1'-0"3ENLARGED ELEVATION - SWDRAWING RECORDDATE DESCRIPTIONGL-01 GL-01 GL-01MATERIAL SCHEDULECOLOR DESCRIPTIONAL-01 Kawneer - Clear Anodized Storefront Anodized AluminumGL-01 Vitro - Solarban 70 Solarblue Tinted GlazingMTL-02 Archifab - Atlas Award Blue Prefabricated Metal Panel CanopyTC-01 SW 6253 Olympus White Texture Coated ConcreteTC-02 SW 7004 Snowbound Texture Coated ConcreteTC-03 SW 7072 Online Texture Coated ConcreteTC-04 SW 6804 Dignity Blue Texture Coated Concrete38 FINISH FLOOR100'-0"123456789101112151413T.O. PANEL148'-0"AREA 'A'AREA 'B'P-75P-74P-73P-72P-71P-70P-69P-68P-67P-66P-65P-64P-63P-62P-61P-60P-59P-58P-57P-56P-55P-54P-53P-52P-51P-50P-49P-48P-47P-46P-45P-44P-43P-42P-41P-40FINISH FLOOR100'-0"ABCDET.0. PANEL142'-0"T.0. PANEL148'-0"P-29P-30P-31P-32P-33P-34P-35P-36P-37P-38P-39TC-01TC-03TC-01TC-04TC-03TC-02TC-02TC-01TC-02TC-03REVEALS, TYP.H.M. DOOR AND FRAME, TYP. -PAINT TO MATCH ADJ. WALL COLORPANEL JOINT, TYP.TEXTURED COATED CONCRETE WALLALUM. STOREFRONT GLAZING SYSTEM, TYP.P.J.ROOF BEYONDMTL-02MTL-02P.J. P.J. P.J. P.J.CBB2B2FINISH FLOOR100'-0"T.O. PANEL148'-0"ABCDET.0. PANEL142'-0"P-86P-85P-84P-83P-82P-81P-80P-79P-78P-77P-76REVEALS, TYP.H.M. DOOR AND FRAME, TYP. -PAINT TO MATCH ADJ. WALL COLORPANEL JOINT, TYP.TEXTURED COATED CONCRETE WALLALUM. STOREFRONT GLAZING SYSTEM, TYP.P.J.ROOF BEYONDP.J. P.J. P.J. P.J.1'-6"2'-0"2'-6"TC-01TC-03TC-03TC-01TC-04TC-02TC-01TC-02CBB2B2AA2A3A3FINISH FLOOR100'-0"23456789101112151413T.0. PANEL142'-0"AREA 'A'AREA 'B'P-27P-26P-25P-24P-23P-22P-21P-20P-19P-18P-17P-16P-15P-14P-13P-12P-11P-10P-09P-08P-07P-06P-05P-04P-03P-02P-01P-28THE RECORD COPY OF THIS DRAWING IS ON FILE AT THE OFFICES OF:ALLIANCE ARCHITECTS, INC.1600 N. COLLINS BLVD.SUITE 1000RICHARDSON, TEXAS 75080(972) 233-0400FAX: (972) 233-2259THIS ELECTRONIC DOCUMENT IS RELEASED FOR THE PURPOSES OF REFERENCE, COORDINATION, AND/OR FACILITY MANAGEMENT UNDER THE AUTHORITY OF:THOMAS M. MAXWELL, REG. #15730 ON. ANY MODIFICATION(S) TO THIS DRAWING SHALL BE IN COMPLIANCE WITH THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS' RULES. © COPYRIGHT 2024 ALLIANCE ARCHITECTS, INC.PROJECT NO.:1600 N. Collins Blvd., Suite 1000Richardson, Texas 75080(972) 233-0400AllianceArch.com9/5/2024 3:36:45 PMC:\Users\robertb\Documents\Revit Local Files\Stonelake Skyport Building 2 2024162_NanaBatman89.rvtA5.012024162-2EXTERIOR BUILDINGELEVATIONS800 S ROYAL LANE, COPPELL TXSTONELAKE SKYPORTBUILDING 209/05/2024Scale:1" = 30'-0"1EAST ELEVATIONScale:1" = 20'-0"4NORTH ELEVATIONScale:1" = 20'-0"3SOUTH ELEVATIONScale:1" = 30'-0"2WEST ELEVATIONMATERIAL SCHEDULECOLOR DESCRIPTIONAL-01 Kawneer - Clear Anodized Storefront Anodized AluminumGL-01 Vitro - Solarban 70 Solarblue Tinted GlazingMTL-02 Archifab - Atlas Award Blue Prefabricated Metal Panel CanopyTC-01 SW 6253 Olympus White Texture Coated ConcreteTC-02 SW 7004 Snowbound Texture Coated ConcreteTC-03 SW 7072 Online Texture Coated ConcreteTC-04 SW 6804 Dignity Blue Texture Coated ConcreteDRAWING RECORDDATE DESCRIPTION08/19/24 Site Plan SubmittalGL-01 GL-01 GL-01 39 FINISH FLOOR 100'-0" 8 9 10 11 12 151413 4 A7.01 D D D D D D D D D C B B2 B2 A A2 A3 A3 CF F2 F2 F F2 F2 E E2 E3 E3 P-40P-41P-42P-43P-44P-45P-46P-47P-48P-49P-50P-51P-52P-53P-54P-55P-56P-57 148'-0" T.O. PANEL A5.03 1 ALUM. STOREFRONT CLERESTORY WINDOWS, TYP. H.M. DOOR AND FRAME, TYP. - PAINT TO MATCH ADJ. WALL COLOR PANEL JOINT, TYP. TEXTURED COATED CONCRETE WALL ALUM. STOREFRONT GLAZING SYSTEM, TYP. ALUM. STOREFRONT GLAZING SYSTEM, TYP. PANEL REVEAL, TYP. TC-02 TC-01 TC-03 TC-02 TC-04TC-02 TC-03TC-01 WALL PACK, TYP. FINISH FLOOR 100'-0" 1 2 3 4 5 6 7 8 9 D D D D D D D D D D D D CB B2 B2 P-55P-56P-57P-58P-59P-60P-61P-62P-63P-64P-65P-66P-67P-68P-69P-70P-71P-72P-73P-74P-75 A5.03 2 A5.03 3 ALUM. STOREFRONT CLERESTORY WINDOWS, TYP. H.M. DOOR AND FRAME, TYP. - PAINT TO MATCH ADJ. WALL COLOR PANEL JOINT, TYP. TEXTURED COATED CONCRETE WALL ALUM. STOREFRONT GLAZING SYSTEM, TYP. ALUM. STOREFRONT GLAZING SYSTEM, TYP. PANEL REVEAL, TYP. P.J. C F F2 F2 E2 E E3 E3 F F2 F2 C TC-01 TC-04 TC-03 TC-02 TC-01 ROOF BEYOND FINISH FLOOR 100'-0" 234567891 A7.02 3 A7.02 2 A7.02 D D D D P-15 P-14 P-13 P-12 P-11 P-10 P-09 P-08 P-07 P-06 P-05 P-04 P-03 P-02 P-01 ALUM. STOREFRONT CLERESTORY WINDOWS, TYP. H.M. DOOR AND FRAME, TYP. - PAINT TO MATCH ADJ. WALL COLOR TEXTURED COATED CONCRETE WALL PANEL REVEAL, TYP. 5'-6" X 10' PREFINISHED LOUVER, TYP. PREFINISHED GUTTER AND RECESSED DOWNSPOUT, TYP. ROOF HATCH BEYOND TC-02 TC-01 TC-03 TC-04 TC-02 TC-03 WALL PACK, TYP. FINISH FLOOR 100'-0" 89101112151413 4 A7.01 D D D D P-14P-15P-16P-17P-18P-19P-20P-21P-22P-23P-24P-25P-26P-27P-28 ALUM. STOREFRONT CLERESTORY WINDOWS, TYP. H.M. DOOR AND FRAME, TYP. - PAINT TO MATCH ADJ. WALL COLOR TEXTURED COATED CONCRETE WALL PANEL REVEAL, TYP. 5'-6" X 10' PREFINISHED LOUVER, TYP. PREFINISHED GUTTER AND RECESSED DOWNSPOUT, TYP. ROOF HATCH BEYOND TC-03 TC-02 TC-04 TC-02 TC-03 TC-01TC-02 THE RECORD COPY OF THIS DRAWING IS ON FILE AT THE OFFICES OF: ALLIANCE ARCHITECTS, INC. 1600 N. COLLINS BLVD. SUITE 1000 RICHARDSON, TEXAS 75080 (972) 233-0400 FAX: (972) 233-2259 THIS ELECTRONIC DOCUMENT IS RELEASED FOR THE PURPOSES OF REFERENCE, COORDINATION, AND/OR FACILITY MANAGEMENT UNDER THE AUTHORITY OF: THOMAS M. MAXWELL, REG. #15730 ON . ANY MODIFICATION(S) TO THIS DRAWING SHALL BE IN COMPLIANCE WITH THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS' RULES. © COPYRIGHT 2024 ALLIANCE ARCHITECTS, INC. PROJECT NO.: 1600 N. Collins Blvd., Suite 1000 Richardson, Texas 75080 (972) 233-0400 AllianceArch.com 9/5/2024 3:36:48 PMC:\Users\robertb\Documents\Revit Local Files\Stonelake Skyport Building 2 2024162_NanaBatman89.rvtA5.02 2024162-2 EXTERIOR BUILDING ELEVATIONS800 S ROYAL LANE, COPPELL TXSTONELAKE SKYPORTBUILDING 209/05/2024 Scale:1" = 20'-0"1 EAST ELEVATION AREA 'A' Scale:1" = 20'-0"2 EAST ELEVATION AREA 'B' Scale:1" = 20'-0"3 WEST ELEVATION AREA 'A' Scale:1" = 20'-0"4 WEST ELEVATION AREA 'B' MATERIAL SCHEDULE COLOR DESCRIPTION AL-01 Kawneer - Clear Anodized Storefront Anodized Aluminum GL-01 Vitro - Solarban 70 Solarblue Tinted Glazing MTL-02 Archifab - Atlas Award Blue Prefabricated Metal Panel Canopy TC-01 SW 6253 Olympus White Texture Coated Concrete TC-02 SW 7004 Snowbound Texture Coated Concrete TC-03 SW 7072 Online Texture Coated Concrete TC-04 SW 6804 Dignity Blue Texture Coated Concrete DRAWING RECORD DATE DESCRIPTION GL-01 GL-01 GL-01 40 FINISH FLOOR100'-0"T.O. PANEL148'-0"1514A2AA3A3BB2B2C1'-6"MTL-02MTL-02TC-01TC-02TC-03TC-01TC-04TC-02ALUM. STOREFRONTGLAZING SYSTEM, TYP.TEXTURED COATED CONCRETE WALLPANEL REVEAL, TYP.P-40P-41P-42P.J.P.J.1A7.03FINISH FLOOR100'-0"T.O. PANEL148'-0"89P-55P-56P-57P-58P-54CFF2F2FF2F2EE3E3CTC-01TC-02TC-02MTL-02ALUM. STOREFRONTGLAZING SYSTEM, TYP.TEXTURED COATED CONCRETE WALLPANEL REVEAL, TYP.P.J.P.J. P.J. P.J. P.J.P.J.FINISH FLOOR100'-0"T.O. PANEL148'-0"1P-74P-75CBB2B21'-6"TC-01TC-02TC-03TC-01TC-04MTL-02MTL-02ALUM. STOREFRONTGLAZING SYSTEM, TYP.TEXTURED COATED CONCRETE WALLPANEL REVEAL, TYP.P.J.THE RECORD COPY OF THIS DRAWING IS ON FILE AT THE OFFICES OF:ALLIANCE ARCHITECTS, INC.1600 N. COLLINS BLVD.SUITE 1000RICHARDSON, TEXAS 75080(972) 233-0400FAX: (972) 233-2259THIS ELECTRONIC DOCUMENT IS RELEASED FOR THE PURPOSES OF REFERENCE, COORDINATION, AND/OR FACILITY MANAGEMENT UNDER THE AUTHORITY OF:THOMAS M. MAXWELL, REG. #15730 ON. ANY MODIFICATION(S) TO THIS DRAWING SHALL BE IN COMPLIANCE WITH THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS' RULES. © COPYRIGHT 2024 ALLIANCE ARCHITECTS, INC.PROJECT NO.:1600 N. Collins Blvd., Suite 1000Richardson, Texas 75080(972) 233-0400AllianceArch.com9/5/2024 3:39:15 PMC:\Users\robertb\Documents\Revit Local Files\Stonelake Skyport Building 2 2024162_NanaBatman89.rvtA5.032024162-2ENLARGED BUILDINGELEVATIONS800 S ROYAL LANE, COPPELL TXSTONELAKE SKYPORTBUILDING 209/05/2024Scale:1/8" = 1'-0"1ENLARGED BUILDING ELEVATIONScale:1/8" = 1'-0"2ENLARGED BUILDING ELEVATIONScale:1/8" = 1'-0"3ENLARGED BUILDING ELEVATIONMATERIAL SCHEDULECOLOR DESCRIPTIONAL-01 Kawneer - Clear Anodized Storefront Anodized AluminumGL-01 Vitro - Solarban 70 Solarblue Tinted GlazingMTL-02 Archifab - Atlas Award Blue Prefabricated Metal Panel CanopyTC-01 SW 6253 Olympus White Texture Coated ConcreteTC-02 SW 7004 Snowbound Texture Coated ConcreteTC-03 SW 7072 Online Texture Coated ConcreteTC-04 SW 6804 Dignity Blue Texture Coated ConcreteDRAWING RECORDDATE DESCRIPTIONGL-01 GL-01 GL-01 41 MEMORANDUM To: Michael Garza, P.E. Director of Public Works, City of Coppell From: Jake Halter, P.E., PTOE Jaric Jones, AICP Date: September 6, 2024 Subject: 800 S Royal Industrial - Trip Generation Introduction The proposed warehouse development is located northeast of Royal Lane and Gateway Boulevard in Coppell, Texas. A conceptual site plan is attached at the end of this memo. The parcel was but is not currently in use , previously a parking lot/shuttle service for DFW airport. The purpose of this memo is to show the expected trip generation from the proposed development. The proposed site will be (2) industrial warehouses totaling 282,512 SF – one building 117,608 SF and the other 164,904 SF. Trip Generation Table 1 shows the resulting weekday daily, and AM and PM peak hour trip generation for the proposed warehouse development. No reductions were taken for pass-by trips or multimodal use. Table 1 –Trip Generation The proposed trip generation does not exceed the Coppell TIA threshold of 1,000 daily trips nor does it exceed the 100 peak hour trip threshold in the AM or PM peak hour. END Daily One-Way Trips IN OUT TOTAL IN OUT TOTAL Warehousing - Total 282,500 SF 150 485 45 13 58 17 43 60 Warehousing - Trucks 282,500 SF 150 170 3 3 6 4 4 8 Warehousing - Passenger Cars 282,500 SF 150 315 42 10 52 13 39 52 Development Totals Total Net New External Vehicle Trips:485 45 13 58 17 43 60 Trip Generation rates based on ITE's Trip Generation Manual , 11th Edition. PM Peak Hour One-Way TripsLand Uses Amount Units ITE Code AM Peak Hour One-Way Trips 42 Attachments: Proposed Conceptual Site Plan 43 T3PT3PS S D D R1 0 ' R 10' R 10'9' 9' 9' 9' 9' 9' 9' 9' 9' 9' 9' 9'R10'R30' EXISTING MEDIAN OPENING PROPOSED BUILDING 1 (117,608 SF) BLDG. HEIGHT: 48'-0" 800 S ROYAL LANE ZONING: LI PROPOSED BUILDING 2 (164,904 SF) BLDG. HEIGHT: 48'-0" 800 S ROYAL LANE ZONING: LI EXISTING MEDIAN OPENING LOADING RAMP LOADING RAMP 9' 9' 9' LOADING RAMP LOADING RAMP R 3 0 'R 1 0 'R40' N85°31'02"E 841.31' N 5 6 ° 3 5 ' 0 4 " W 23 9 . 3 5 ' N70° 5 6 ' 4 4 " W 673. 8 9 'N0°15'27"W651.09'S0°03'01"E1068.65'LOT 1R-2, BLOCK 2 GATEWAY BUSINESS PARK PARK REPLAT INST.NO.201700235650 LANTHIAN COPPELL TX LLC INST.NO.202300259370 ZONING: LI ST. LOUIS & SOUTHWE S T E R N R A I L R O A D VOLUME 95, PAGE 518 (100' right-of-way) INT E R S T A T E H I G H W A Y 6 3 5 GAT E W A Y B O U L E V A R D (vari a b l e w i d t h r i g h t - o f - w a y )S. ROYAL LANE(variable width right-of-way)9'R30'R1 0' R 1 0 'R20 'PROP. 3" BACK FLOW PREVENTER PROP. BFR PROP. BFR PROP. BFR PROP. BFR PROP. BFR PROP. BFR PROP. BFR PROP. SSMH PROP. BFR PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. 24' FIRE LANE EASEMENT PROP. BFR PROP. SIDEWALK PROP. SIDEWALK PROP. SIDEWALK PROP. BFR PROP. BFR PROP. BACK FLOW PREVENTER PROP. BACK FLOW PREVENTER EX. MEDIAN EX. MEDIAN EX. MEDIAN EX. MEDIAN EX. CURB PROP. SIDEWALK EX. CURB (TYP.) EX. CURB (TYP.) PROP. BFR PROP. BFR PROP. BFR PROP. BFR PROP. FH PROP. FDC PROP. FDC PROP. SSMH PROP. MONUMENT SIGN PROP. MONUMENT SIGN PROP. CLEANOUT PROP. 60' BUILDING SETABACK PROP. 60' BUILDING SETABACK PROP. 60' BUILDING SETABACK 9' 9' PROP. 60' BUILDING SETBACK 10' BUILDING SETBACK VOL.95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' BUILDING SETBACK VOL.95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 60' BUILDING SETBACK 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 10' BUILDING SETBACK VOL.95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 15' LANSCAPE EASEMENT VOL. 95127, PG. 4328 20' UTILITY EASEMENT VOL. 95127, PG. 4328 10' BUILDING SETBACK VOL. 95127, PG. 4328 15' LANDSCAPE & UTILITY EASEMENT VOL. 95127, PG. 4328 ±418.9' ±4 9 9 . 8 'NOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKINGNOPARKING11 8 145 15 10 1114 9 8 9 15 12 15 15 15 14 14 1411 11 14 1111 7 8 8712 878 10 FLFLFLFLFLFLFLFLFLFL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL18.0'18.0' 18.0'18.0'18.0'18.0'18.0'18.0'18.0'18.0' 18.0'18.0' 18.0' 18.0'18.0'18.0'18.0'18.0'18.0'18.0'18.0' 18.0' 18.0'24.0'88.0' 200.0' 24.0'88.0' 200.0' 8.0'40.0'380.0'763.8'18.0'18.0'18.0' 18.0'45.0'45.0'18.0' 18.0'18.0' 18.0'9.0'9.0'9.0' 9.0' 9.0'9.0' 9.0'9.0'9.0'9.0'24.0'FIRE LANE24.0' FIRELANE 5.0' 10.0'10.0'88.0' 88.0'7.0'6.0' 6.0' 6.0' 10.0' 10.0' 9.0' 9.0' 9.0' 18.0' 18.0'3.0' (TYP.)30.0' 30.0' 200.0'220.0' 30.0'9.0'9.0'6.0'18.0' 10.0' 5.0' 10.0'5.0'25.0'25.0' 23.0'5.0'79.1'6.0'71.3'PROP. 15' WATER EASEMENT PROP. 24' FIRE LANE EASEMENT PROP. VARIABLE WIDTH FIRE LANE EASEMENT PROP. 24' FIRE LANE EASEMENT PROP. 24' FIRE LANE EASEMENT PROP. 30' FIRE LANE EASEMENT PROP. 24' FIRE LANE EASEMENT PROP. 24' FIRE LANE EASEMENT 15' LANSCAPE EASEMENT VOL. 95127, PG. 4328 20' UTILITY EASEMENT VOL. 95127, PG. 4328 PROP. RETAINING WALL PROP. RETAINING WALL PROP. RETAINING WALL PROP. 3P TRANSFORMER PROP. 3P TRANSFORMER 30.0'72.0'32.0'72.0'5.0'9'9.0'9.0'9.0'9.0'9.0'9.0'9.0'9.0'18.0'9.0'R30' 12' SCREENING WALL 12' SCREENING WALL 12' SCREENING WALL 12' SCREENING WALL ANTICIPATED PUMP ROOM LOCATION ANTICIPATED PUMP ROOM LOCATION PROP. TRASH COMPACTOR PROP. TRASH COMPACTOR PROP. 15' WATER EASEMENT 40.0' PROP. 6' SIDEWALK EASEMENTR100'R100'R100'R100'R100'R100'R100'R100'R60'R80'R60'R80'PROP. 3" WATER METER PROP. 30' WATER EASEMENT PROP. BFRR10'R30'R100'R 3 0 'R 1 0'R30' R 3 0 'R100'R100'R54'R30 'R54'R30'R 3 0 ' R 5 4 ' R 30'R 5 4 'PROP. IRRIGATION METER R2' R2' PROP. 18'x8' CONCRETE MEDIAN PROP. 10' SIDEWALK EASEMENT PROP. 10' SIDEWALK EASEMENT 56.0'S. ROYAL LANEINT E R S T A T E H I G H W A Y 6 3 5 GA T E W A Y B O U L E V A R D ST. LOUIS & SOUTHWESTERN RAILROAD SITE BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT13455 NOEL ROAD, TWO GALLERIA OFFICE TOWERSUITE 700, DALLAS, TX 75240PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-928© 2024 KIMLEY-HORN AND ASSOCIATES, INC.064405643NMHGCPAKAAUGUST 2024Engineer P.E. No. Date FOR REVIEW ONLY NOT FOR CONSTRUCTION OR PERMIT PURPOSES. NEDA M. HOSSEINY 126707 08/19/2024 STONELAKE SKYPORTLOT 1, BLOCK AGATEWAY BUSINESS PARKCOPPELLTEXASPRELIMINARY SITEPLAN1 OF 1 NORTH 1.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION FOR NORTH CENTRAL TEXAS, LATEST EDITION, AND THE CITY OF COPPELL STANDARD CONSTRUCTION DETAILS. 2.DURING THE CONSTRUCTION OF THESE IMPROVEMENTS, ANY INTERPRETATION OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION FOR NORTH CENTRAL TEXAS, AND ANY MATTER WHICH REQUIRES THE APPROVAL OF THE OWNER, MUST BE APPROVED BY THE DIRECTOR OF ENGINEERING OR HIS DESIGNEE BEFORE ANY CONSTRUCTION INVOLVING THAT DECISION COMMENCES. ASSUMPTIONS ABOUT WHAT THESE DECISIONS MIGHT BE WHICH ARE MADE DURING THE BIDDING PHASE WILL HAVE NO BEARING ON THE DECISION. 3.ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 4.ALL CURBS ARE 6" IN HEIGHT UNLESS OTHERWISE NOTED. 5.NO OUTSIDE STORAGE IS PROPOSED. NOTESLEGEND FIRE HYDRANT FIRE LANEFL PROPERTY LINE ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY, FLOOD INSURANCE RATE MAP COMMUNITY PANEL NO. 48113C0135K, DATED JULY 7, 2014, THIS PROPERTY IS WITHIN FLOOD ZONE X. ZONE X - AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. THE FLOOD STATEMENT DOES NOT IMPLY THAT THE PROPERTY AND/OR THE STRUCTURE THEREON WILL BE FREE FROM FLOODING OR FLOOD DAMAGE. ON RARE OCCASIONS, GREATER FLOODS CAN AND WILL OCCUR AND FLOOD HEIGHTS MAY BE INCREASED BY MAN-MADE OR NATURAL CAUSES. THIS FLOOD STATEMENT SHALL NOT CREATE LIABILITY ON THE PART OF THE SURVEYOR. FLOOD NOTE BFR (BARRIER FREE RAMP) CITY OF COPPELL FIRE LANE SITE PLAN STONELAKE SKYPORT LOT 1, BLOCK A TOTAL ACREAGE: 16.0719 ACRES ENGINEER / SURVEYOR / APPLICANT: KIMLEY-HORN & ASSOCIATES, INC. 13455 NOEL ROAD TWO GALLERIA OFFICE TOWER, SUITE 700 DALLAS, TEXAS 75240 PH (972) 770-1300 CONTACT: NEDA HOSSEINY, P.E. OWNER/DEVELOPER: ARCHITECT: ALLIANCE ARCHITECTS 1600 N. COLLINS BLVD. #1000 RICHARDSON, TX 75080 PH. (972) 233-0400 CONTACT: THOMAS M. MAXWELL, AIA, CCCA STONELAKE CAPITAL PARTNERS, 100 CRESCENT COURT, SUITE 850, DALLAS, TX 75201 PH. (214) 220-7297 CONTACT: BLAKE WILSON CITY OF COPPELL, DALLAS COUNTY, TEXAS ZONED LI (LIGHT INDUSTRIAL) CITY PROJECT NO. SITE24-08-000828 SUBMITTED SEPTEMBER 10, 2024 44