Loading...
BP 2025-02-20 PZPlanning & Zoning Commission City of Coppell, Texas Meeting Agenda 255 E. Parkway Boulevard Coppell, Texas 75019-9478 255 Parkway Blvd.6:00 PMThursday, February 20, 2025 Edmund Haas Cindy Bishop (Chair) Sue Blankenship Freddie Guerra Kent Hafemann Ed Maurer Samit J. Patel Notice is hereby given that the Planning and Zoning Commission of the City of Coppell, Texas, will meet on Thursday, February 20, 2025, in Regular Called Session at 6:00 p.m. for Work Session, and Regular Session at 6:30 p.m., at Town Center, 255 Parkway Boulevard, Coppell, Texas. As authorized by Section 551.071(2) of the Texas Government Code, this meeting may be convened into closed Executive Session for the purpose of seeking confidential legal advice from the City Attorney on any agenda item listed herein. The City of Coppell reserves the right to reconvene, recess or realign the Work Session, or called Executive Session, or order of business, at any time prior to adjournment. As authorized by Section 551.127, of the Texas Government Code, one or more commissioners or employees may attend this meeting remotely using videoconferencing technology. The purpose of this meeting is to consider the following items: Regular Session (Open to the Public) 1.Call To Order 2.Work Session (Open to the Public) a. Discussion of agenda items. 3.Regular Session (Open to the Public) 4.Citizens Appearance Page 1 City of Coppell, Texas Printed on 2/14/2025 1 February 20, 2025Planning & Zoning Commission Meeting Agenda Provide an opportunity for citizens to address the Planning and Zoning Commission on any matter. Anyone wishing to address the commission should register prior to the start of the meeting. There is a three (3) minute time limit for each citizen to speak however, additional time may be granted by the commissioners. The Planning and Zoning Commission is not permitted to take action on any subject raised by a speaker during Citizens' Appearance. Election of Officers.5. 6.Consider approval of the December 19, 2024, Planning and Zoning meeting minutes. December 19, 2024, Planning & Zoning Meeting Minutes .pdfAttachments: 7.PUBLIC HEARING: Consider approval of PD-322-A, Carrollton Farmers Branch ISD Ag Barn, a zoning change request from A (Agricultural) to PD-322-A (Planned Development-322-Agricultural), to allow the construction of a new 14,000-sf educational building, and an approximate 21,800-sf metal barn, butterfly station and education stations on 41.673 acres located along the north side of Sandy Lake Road, abutting the Elm Fork Trinity River to the east at the City limits; at the request of Ben Sanchez of Parkhill, representing Carrollton Farmers Branch ISD. STAFF REP.: Mary Paron-Boswell Continuation Memo.pdfAttachments: 8.Consider approval of Carrollton Farmers Branch I.S.D. Ag Barn Addition, Lot 1, Block A, Minor Plat, to plat the property into one lot, for the construction of a new educational building, on 41.96 acres located along the north side of Sandy Lake Road abutting the Elm Fork Trinity River to the east at the city limits; at the request of Ben Sanchez of Parkhill, representing Carrollton Farmers Branch ISD. STAFF REP.: Mary Paron-Boswell Continuation Memo.pdfAttachments: 9.PUBLIC HEARING: Consider approval of PD-317R-C, Graystone Construction Building, Lot 2, Northlake Estates, a zoning change request from C (Commercial) to PD-317R-C (Planned Development-317 - Commercial), to approve a new Detail Site Plan for an 1,800-sf office building on 0.23 acres of property located at 192 Southwestern Blvd., at the request of Danny Didyk, Graystone Construction, being represented by Macatee Engineering, LLC. STAFF REP.: Mary Paron-Boswell Staff Report.pdf Detail Site Plan.pdf Landscape Plan.pdf Building Elevations and Signage.pdf Attachments: Page 2 City of Coppell, Texas Printed on 2/14/2025 2 February 20, 2025Planning & Zoning Commission Meeting Agenda Floor Plan.pdf Applicants Letter.pdf 10.PUBLIC HEARING: Consider approval of PD-323-HC, Coppell Entertainment Plaza, Lot 1, Block A, a zoning change request from HC (Highway Commercial) to PD-323-HC (Planned Development 323-Highway Commercial) to allow for a Detail Site Plan for a building containing five (5) pickleball courts (13,000-sf) with a speculative restaurant (2,485-sf) and retail space (2,170-sf), totaling 17,655-sf on 1.6 acres of property, located on the north side of State Highway 121, approximately 940 feet west of N Denton Tap Road, being developed by Coppell PKB LLC, and being represented by Lindsey Mayer, Dynamic Engineering Consultants, PC. STAFF REP.: Matthew Steer Staff Report.pdf Site Plan.pdf Landscape Plan & Tree Survey.pdf Elevations, Details & Rendering.pdf Floor Plan.pdf Photometric Plan.pdf Attachments: 11.Consider approval of an Coppell Entertainment Plaza, Lot 1, Block A, Minor Plat, a minor plat to create a building site for an indoor pickleball/retail/restaurant facility and associated easements on 1.62 acres of property located on the north side of State Highway 121, approximately 940 feet west of N Denton Tap Road. STAFF REP.: Matthew Steer Staff Report.pdf Minor Plat.pdf Attachments: 12.PUBLIC HEARING: Consider text change amendments to the Code of Ordinances, Chapter 12, Article 42, Special Definitions to add definitions for “showroom”, “warehouse”, “distribution center”, “fulfillment center”, and “retail center”; and, to amend Article 25, Light Industrial District, of said chapter to add said new definitions to permitted uses; and, to amend Article 31 of said chapter to allow conversion of dock areas to additional parking, to allow “warehouse”, “distribution center” and “fulfillment center” as defined herein to require not less than one (1) parking space per 2,000 square feet, “showroom” as defined herein to require not less than one (1) parking space per 1,000 square feet; to allow the Director of Community Development to approve up to a 10% reduction in parking required for retail centers with buildings greater than 10,000 square feet. STAFF REP.: Matthew Steer Staff Report.pdfAttachments: Page 3 City of Coppell, Texas Printed on 2/14/2025 3 February 20, 2025Planning & Zoning Commission Meeting Agenda Redlined Sec 12-25-1 Use Regulations.pdf Redlined Sec 12-31-6 Parking Requirements Based on Use.pdf Redlined Sec 12-31-7 Rules for Computing Number of Parking Spaces.pdf Redlined Sec. 12-31-3 Off Street Loading Space All Districts.pdf Relined Sec 12-42-1 Definitions.pdf 13.Update on City Council items. 14.Adjournment PUBLIC NOTICE - STATEMENT FOR ADA COMPLIANCE The City of Coppell acknowledges its responsibility to comply with the Americans With Disabilities Act of 1990. Thus, in order to assist individuals with disabilities who require special services (i.e. sign interpretative services, alternative audio/visual devices, and amanuenses) for participation in or access to the City of Coppell sponsored public programs, services and/or meetings, the city requests that individuals make requests for these services seventy-two (72) hours – three (3) business days ahead of the scheduled program, service, and/or meeting. To make arrangements, contact Kori Allen, ADA Coordinator, or other designated official at (972) 462-0022, or (TDD 1-800-RELAY, TX 1-800-735-2989). CERTIFICATE I certify that the above Notice of Meeting was posted on the bulletin board at the City Hall of the City of Coppell, Texas on this 14th day of February, 2025, at _____________. ______________________________ Kami McGee, Board Secretary Page 4 City of Coppell, Texas Printed on 2/14/2025 4 255 E. Parkway Boulevard Coppell, Texas 75019-9478City of Coppell, Texas Minutes Planning & Zoning Commission 6:00 PM 255 Parkway Blvd.Thursday, December 19, 2024 Edmund Haas Cindy Bishop (Chair) Sue Blankenship Freddie Guerra Kent Hafemann Ed Maurer PRESENT: Chairman, Edmund Haas; Commissioner, Sue Blankenship; Commissioner, Cindy Bishop; Commissioner, Ed Maurer; Commissioner, Kent Hafemann; and Commissioner, Freddie Guerra Also present were Mary Paron-Boswell, Senior Planner; Matt Steer, Development Services Administrator; Luay Rahil, Assistant Director of Community Development; and Kami McGee, Board Secretary. Notice was given that the Planning and Zoning Commission of the City of Coppell, Texas, met on Thursday, December 19, 2024, in Regular Called Session at 6:00 p.m. for Work Session, and Regular Session at 6:30 p.m., at Town Center, 255 Parkway Boulevard, Coppell, Texas. As authorized by Section 551.071(2) of the Texas Government Code, this meeting may be convened into closed Executive Session for the purpose of seeking confidential legal advice from the City Attorney on any agenda item listed herein. The City of Coppell reserves the right to reconvene, recess or realign the Work Session, or called Executive Session, or order of business, at any time prior to adjournment. As authorized by Section 551.127, of the Texas Government Code, one or more commissioners or employees may attend this meeting remotely using videoconferencing technology. The purpose of this meeting was to consider the following items: Regular Session (Open to the Public) Call To Order1. Chairman Haas called the meeting to order at 6 p.m. Page 1City of Coppell, Texas 7 December 19, 2024Planning & Zoning Commission Minutes Work Session (Open to the Public)2. The Planning and Zoning Commission was briefed on each posted agenda item, no vote was taken on any item discussed. Regular Session (Open to the Public)3. Citizens Appearance4. Chairman Haas advised that no one signed up to speak at Citizens Appearance. 5.Consider approval of the November 21, 2024, Planning and Zoning meeting minutes. A motion was made by Commissioner Hafemann, seconded by Commissioner Guerra, to approve the minutes of the November 21, 2024, Planning and Zoning meeting. The motion was approved 4-0, with Commissioner Guerra and Commissioner Maurer abstaining. 6.PUBLIC HEARING: Consider approval of a zoning change request from PD-157R8-C (Planned Development-157 Revision 8-Commercial) to PD-157R9-C (Planned Development 157-Revision 9-Commercial) to allow the operation of a 1,167-square-foot restaurant located at 817 S MacArthur along the west side of S MacArthur Blvd; south of E Belt Line Road at the request of MM Valley Ranch, LLC, being represented by Mark Guest, Ebarb + Guest Architecture. Matt Steer, Development Services Administrator, presented the case with exhibits stating that staff is recommending approval of PD-157R9-C, Valley Ranch Plaza, subject to the following conditions: 1. Proposed PD to increase allowed restaurant area on Lots 1 & 3, Block A from 8,400 to 10,120 square feet. 2. Proposed PD to utilize an exception to allow 209 parking spaces to accommodate the proposed increase in restaurant uses that would typically require 214 parking spaces. 3. Hours of operation shall not exceed 10 a.m. to 12:00 a.m., daily. 4. Proposed signage shall require a permit. 5. A grease trap be installed that is adequately sized to support the restaurant use. Mark Guest, 3309 Elm Street, #102-241, Dallas TX, 75226, was present to answer questions of the commission and stated they were in agreement with staff conditions. Chairman Haas opened the Public Hearing and stated that no one signed up to speak. Chairman Haas closed the Public Hearing. A motion was made by Commissioner Guerra, seconded by Commissioner Maurer, to approve the agenda item with staff conditions. The motion passed unanimously, 6-0. Page 2City of Coppell, Texas 8 December 19, 2024Planning & Zoning Commission Minutes 7.PUBLIC HEARING: Consider approval of PD-320-TC, a zoning change request from TC (Town Center) to PD-320-TC (Planned Development 320- Town Center) to allow the operation of a 4,618 square-foot drive-through restaurant located along the east side of Denton Tap Road; North of Town Center Blvd at 240 N. Denton Tap Road on 1.674 acres of property. Mary Paron-Boswell presented the case with exhibits and stated that staff is recommending approval of PD-320-TC, subject to the following PD conditions: 1. To allow for a restaurant with a drive-through area as presented. 2. To allow for the landscaping as presented. 3. Hours of operation shall not exceed 10 am to 10 p.m., daily. 4. Any proposed signage shall require a separate submittal and permit. 5. The restaurant must be served by an adequately sized grease trap on-site. Travis Brown, GPD Group, 5050 Quorum Drive, Ste. 338, Dallas, Texas 75254, was present to answer questions of the commission and stated they were in agreement with staff conditions. Chairman Haas opened the Public Hearing and stated that no one signed up to speak. Chairman Haas closed the Public Hearing. A motion was made by Commissioner Maurer, seconded by Commissioner Blankenship, to approve the agenda item with staff conditions. The motion passed unanimously, 6-0. Update on City Council items.8. Chairman Haas stated that the commission was updated on City Council items during Work Session. Adjournment9. There being no further business before the Commission, Chairman Haas adjourned the meeting at 7:03p.m. ______________________________ Edmund Haas, Chair ______________________________ Kami McGee, Board Secretary Page 3City of Coppell, Texas 9 MEMORANDUM To: Planning and Zoning Commission From: Mary Paron-Boswell, Sr. Planner Date: February 20, 2025 Reference: Consider approval of PD-322-A, Carrollton Farmers Branch ISD Ag Barn, a zoning change request from A (Agricultural) to PD-322-A (Planned Development-322- Agricultural), to allow the construction of a new 14,000-sf educational building, and an approximate 21,800-sf metal barn, butterfly station and education stations on 41.673 acres located along the north side of Sandy Lake Road, abutting the Elm Fork Trinity River to the east at the City limits; at the request of Ben Sanchez of Parkhill, representing Carrollton Farmers Branch ISD. The applicant has requested that this item be continued to the March 20th Planning and Zoning meeting, allowing them time to address some items that came up unexpectedly. Staff requests that the Public Hearing be opened and continued to the March 20th meeting as requested. 11 MEMORANDUM To: Planning and Zoning Commission From: Mary Paron-Boswell, Sr. Planner Date: February 20, 2025 Reference: Consider approval of Carrollton Farmers Branch ISD Ag Barn Addition, Lot 1, Block A, Minor Plat, to plat the property into one lot, for the construction of a new educational building, and metal barn, on 41.96 acres located along the north side of Sandy Lake Road, abutting the Elm Fork Trinity River to the east at the City limits; at the request of Ben Sanchez of Parkhill, representing Carrollton Farmers Branch ISD. The applicant has requested that this item be continued to the March 20th Planning and Zoning meeting, allowing them time to address some items that came up unexpectedly. Staff requests that the Public Hearing be opened and continued to the March 20th meeting as requested. 13 ITEM # 9 Page 1 of 4 CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT CASE No.: PD-317R-C, Grayston Construction Offices P&Z HEARING DATE: February 20, 2025 C.C. HEARING DATE: March 11, 2025 STAFF REP.: Mary Paron-Boswell, AICP Senior Planner LOCATION: 192 Southwestern Blvd SIZE OF AREA: 0.23 acres CURRENT ZONING: C (Commercial) REQUEST: A zoning change request from C (Commercial) to PD-317R-C (Planned Development-317 Revised- Commercial), to approve a new Detail Site Plan for an 1,800-sf office building on 0.23 acres of property located at 192 Southwestern Blvd at the request Danny Didyk, Graystone Construction being represented by Macatee Engineering, LLC. APPLICANT: Applicant: Owner: Dayton Macatee Danny Didyk Macatee Engineering, LLC. Graystone Construction 4144 N Central Expressway 192 Southwestern Blvd Dallas, Texas 75243 Coppell, TX 75019 214-373-1180 214-761-3461 HISTORY: This property consists of Lot 2 within the North Lake Estates Subdivision, recorded in 1961. The homes to the north were constructed in the late 1960’s and early 1970’s. The entire subdivision was commercially zoned until 2002, when some of the homes were rezoned to SF-7 within a Planned Development (PD-198-SF-7) with conditions. This gave the residences a “conforming” status to allow for legal site improvements and the associated insurance and financing requirements. This property along with several others in the subdivision were never rezoned and remain Commercial (C). There have been several Special Use Permits (SUP’s) approved for the remaining commercially zoned properties which have included a beauty salon, a construction office, landscaping business, and a Tren-Trench safety consultant. These businesses were also granted parking, landscaping and fencing exceptions. The property to the west had a Planned Development approved in 1999 for a commercial specialty contractor that did waterproofing and restoration of commercial buildings. The existing house was used as an office, and they were granted permission to add on a 1,560-sf warehouse building. They were also granted several development variances. 15 ITEM # 9 Page 2 of 4 An office building was previously requested in 2024, at this location, with the warehouse existing building to remain. This request was ultimately withdrawn. HISTORIC COMMENT: This property does not have any historic significance. TRANSPORTATION: Howell Drive is a 24-ft unimproved local road within a 50-ft right-of-way. Plans have been approved to improve Howell Drive and Bullock Drive. SURROUNDING LAND USE & ZONING: North: Commercial; (C) Commercial South: Office Warehouse; (LI) Light industrial East: Office Building; (C) Commercial West: Office Building; (C) Commercial (PD-174-C) COMPREHENSIVE PLAN: Coppell 2030, A Comprehensive Master Plan, shows this property as suitable for development in accordance with the Mixed-Use Community Center (or Single Family Residential) and includes office uses. DISCUSSION: As mentioned in the History section above, the site was platted as part of the Northlake Estates subdivision in 1961. This is one of several original lots that face Southwestern Blvd that are zoned Commercial (C). There are another three lots located on Howell Dr. directly north of these lots along Southwestern Blvd, which are also zoned Commercial. On the east side of Howell Dr., facing Southwestern Blvd, Cavalry Construction built a professional office building and garage over two lots. They were approved for a professional office with a driveway on Southwestern Blvd which is their primary entrance as well as a driveway on Howell Dr., that has not been constructed but is shown as “future” on the approved plans. An office building was previously requested on the subject property, with the existing warehouse building to remain. This request was ultimately denied at Planning and Zoning Commission and withdrawn prior to City Council. They have made changes to this overall request, with the main focus still being the construction of the 1,800-sf office. As it relates to land use, the request for professional office use is the least intensive land use within the list of permissible commercial uses within the current Commercial District. The amount of parking required and total trip generation is low in comparison to what could be allowed. The building is proposed to contain offices and a conference room. According to the applicant, the majority of the time, the employees will be on a job site. Site Plan This site has several challenges in being able to be developed. The setbacks for this commercial lot create a very small area for any development to occur without 16 ITEM # 9 Page 3 of 4 using the Planned Development process, which allows for variances. The Site Plan identifies the existing garage/warehouse at the northern portion of the site that is proposed to remain. This will house their refuse bins and other materials that need to be stored indoors, out of the weather. This building was recently updated and the proposed plans show adding a brick wainscot to match the brick on the proposed office space. The applicant plans to construct a new 1,800-sf office building with four offices and a small conference room. Six new parking spaces are proposed. The other change to the site plan is the removal of the outside storage for their trailers. The trailers will be stored off-site. The access to the site is proposed to be from Howell Drive. The applicant considered alternative entrance locations, but this proposed layout provides the best layout both for parking, building layout and landscaping the site. The applicant has no plans to park any of their vehicles on Howell Drive. An eight (8) foot wooden board on board privacy fence with a trim cap is proposed to screen the site along the northern and western sides. The western side abuts another commercial property, while the northern property line abuts an alley that has not been constructed and a commercial property beside it. The applicant is requesting PD conditions that relate to the setbacks, reflecting the existing building location on site and the limited room for development. Staff is not opposed to this setback request. Building Elevations & Signage The building will have a brick veneer with a standing seam metal roof and canopy across the northern façade. Large glass windows will frame the northern portion of the building and a good portion of the southern elevation. The eastern and western elevations will be brick. The main entrance will be from the northern elevation, accessed from the parking area. The address and sign for the business is proposed to be located on the southern elevation with 12” pin mounted anodized aluminum letters. A variance to the 50% glazing requirement is being requested for the northern elevation where they are showing 60% glass. Landscaping The proposal shows a minimum 15-ft landscape strip along Howell Drive and 20- ft along the southern portion of their site. The 10-ft perimeter landscaping fluctuates in certain areas, but the amount of landscaping provided exceeds the requirement. At the northern end, landscaping is being provided adjacent to the parking area and some pavement in front of the warehouse is proposed to be replaced with landscaping. Additional landscaping is being provided along the western perimeter and in front of the building. The site is approximately 36% landscaped, not including the right-of-way in front of this property along Southwestern Blvd which will also be landscaped. This portion adds 2,033-sf of landscaping that will be maintained by the applicant. They are providing the overall required number of trees, spread throughout the site and onto the right-of- way that they will be required to maintain. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: 17 ITEM # 9 Page 4 of 4 Staff is recommending APPROVAL of the request subject to the following conditions: 1. There may be additional comments during the Detail Engineering review. 2. PD Conditions: a. Approve the reduced setbacks. b. To allow the landscaping areas as proposed. c. To allow the glazing of the building as shown. d. Allow parking as shown. ALTERNATIVES: 1. Approval of the request 2. Denial of the request 3. Modification of the request 4. Take the case under advisement to a future date ATTACHMENTS: 1. Detail Site Plan 2. Landscape Plan 3. Building Elevations & Signage 4. Floor Plan 5. Applicants letter 18 ZONING: CZONING: CZONING: CZONING: PD-198-SF-7ZONING: PD-198-SF-7ZONING: CZONING: CZONING: PD-174-CZONING: UZONING: C(Tex. Reg. No. F-456)4144 N. CENTRAL EXPWY, SUITE 340DALLAS, TEXAS 75243TEL 214-373-1180daytonm@macatee-engineering.com192 SOUTHWESTERN BLVD GRAYSTONE CONSTRUCTION OFFICEOWNER/DEVELOPER:GRAYSTONE CONSTRUCTION, LLCCONTACT: DANNY DIDYK1300 POWDER RIVER TRLSOUTHLAKE, TX 76092TEL: 214-761-3461EMAIL: danny@graystoneconstruction.comPROPERTY LOCATED AT 192 SOUTHWESTERN BOULEVARD, IN THE CITY OFCOPPELL, TEXAS AND DESCRIBED AS LOT NO. 2 OF NORTH LAKE ESTATES,AN ADDITION TO THE CITY OF COPPELL, DALLAS COUNTY, TEXAS ACCORDINGTHE MAP THEREOF RECORDED ON VOLUME 45, AT PAGE 65 OF THE MAPRECORDS OF DALLAS COUNTY, TEXAS.LEGAL DISCRIPTIONSITE DATA TABLEEXISTING ZONING: CPROPOSED USE: BUSINESS OFFICESITE AREA: 10,048 SFOFFICE BUILDING: 1,800 SFWAREHOUSE: 879 SFBUILDING HEIGHT: 14'-8"LOT COVERAGE: 18%FLOOR AREA RATIO: 5:1PARKINGREQUIRED: OFFICE: 1,800SF AT 1:300 6 SPACESTOTAL PARKING REQUIRED: 6 SPACESPROVIDED:EXISTING PARKING 1 SPACESNEW PARKING 6 SPACESTOTAL PARKING PROVIDED: 7 SPACESIMPERVIOUS AREA: 6,752 SF (67%)PERVIOUS AREA: 3,296 SF (33%)PROPOSED DEVELOPMENT CONDITIONS TABLE1.To allow for reduced setbacks as listed: -20-ft from Southwestern Blvd. (southern property line)-15-ft off Howell Dr. (eastern property line)-0-ft off alley (northern property line)-10=ft off western property line2.To allow landscaping as shown.3.Allow parking as shown.4.To allow for more than 60% glazing on the north elevation of building.(Refer to Architectural North Elevation)19 ZONING: CSOUTHWESTERN BLVDHOWELL DRIVE 8 FTFENCE8 FTFENCE24"X24"CONCRETEPAVERSWITH BLACKRIVER ROCKAC UNIT5.068.869.544.110.1INTERIORZONENON-VEHICULARZONEPERIMETERZONEWAREHOUSEOFFICE2,033 SFR.O.W. LANDSCAPE55.20510204010PLANT MATERIAL LISTSUMMARY CHARTQNTYSYMCOMMON NAMEBOTANICAL NAMESIZETREES3SHRUBSGREEN CLOUD SAGEIlex vomitoria 'Nana'192' HGT; 5 GALLON CONT.; 3' O.C.12" HGT; 1 GALLON CONT.; 3' O.C.BLUE RUG JUNIPERJuniperus horizontalis8" HGT; 1 GALLON CONT.; 3' O.C.GROUNDCOVER/TURF GRASSCynodon dactylonCOMMON BERMUDASOD; SFCHINESE PISTACHEPistacia chinensis2BIG TOOTH MAPLEAcer grandidentatumSUNSHINE LIGUSTRUMLigustrum sinense 'Sunshine'2' HGT; 5 GALLON CONT.; 3' O.C.32432945803LACEBARK ELMUlmus parvifolia3" CAL.; 12' MIN HT; 30 GAL MIN. CONT.3" CAL.; 12' MIN HT; 30 GAL MIN. CONT.CHINQUAPIN OAKQuercus muhlenbergii3" CAL.; 12' MIN HT; 30 GAL MIN. CONT.4TEXAS SEDGECarex texensis2" CAL.; 12' MIN HT; 30 GAL MIN. CONT.9SPREADING JAPANESE YEWTaxus cuspidata8" HGT; 1 GALLON CONT.; 3' O.C.18BLACK RIVER ROCK2 INCH DEPTH; CY6121-2"SOUTHERN WAX MYRTLEMyrica cerifera3" CAL.; 12' MIN HT; 30 GAL MIN. CONT.4" O.C.35164"ConcreteFillPost Profile: Cut View / Elevation View316"1564"* Length may varyQUANTITYCOMPONENTS LENGTHTop RailInterlocking PicketPost CapAluminumBottom RailFence BracketBottom Rail Cover132"Concrete Fill164"D:\$- 00 -Cl ie nt -Ce da r Fen ce Co \CFC Fe nce S ys tem \ex te ri or wo od s cre w. jp g Post Profile:Elevation View4"112" Typ.Consult localconditions, codes,and standard building practicesfor post depth12"Typ4116"4332"1"x5.75" Interlocking Picket1991" * 1 5/8" (Typ) Exterior Wood Screws244" x 4.9" Top Rail191" *Fence Bracket4Aluminum Bottom Rail190 1/2"1" x 5.75"Bottom Rail Cover291" *5" x 5" Post1144" *Post Cap: Pyramid, Flat,or Crown1L-1LANDSCAPE PLANSCALE: 1" = 10'-0"NORTH VICINITY MAPNTSE. BROOKEASSOCIATES, LLCP: 817.219.2665E: erin@ebrooke.com02/10/2025192 Southwestern PERMIT SET 192 Southwestern COPPELL, TX 75231 SITELANDSCAPE ARCHITECTURE DESIGNPD CONDITIONS:LANDSCAPE NOTES:LANDSCAPE DATA TABLEEXISTING & PROPOSED:TREES--9 REQUIRED--9 PROVIDED (7 SMALL CANOPY TREES & 6 LARGE)INTERIOR LANDSCAPING--330 SF REQUIRED--431 SF PROVIDED-TREES--2 REQUIRED--0 PROVIDEDNON-VEHICULAR LANDSCAPING--1,237 SF REQUIRED--298 SF PROVIDED-TREES--2 REQUIRED--0 PROVIDEDPERCENTAGE OF SITE AREA DEVOTED TO LANDSCAPING: 36%AREA OF ROW DEVOTED TO LANDSCAPING: 2,033 SFADDITIONAL TREES MAY BE PLANTED ONCE THE UNDERGROUNDLINE HAS BEEN ABANDONED20 GRAYSTONE CONSTRUCTION GRAYLITE II GLASS BRICK VENEER16'-9"TOP END WALL PEAK TOP OF SLAB 11'-5"10'-0"STANDING SEAM METAL ROOF 12" PIN MOUNTED SIGNAGE EAST ELEVATION WEST ELEVATIONNORTH ELEVATION SOUTH ELEVATION16'-9"STANDING SEAM METAL ROOF 11'-5"16'-1"10'-0"CEILING HT. GRAYLITE II GLASS BRICK VENEER GUTTER / FASCIA BRICK VENEER7'-0"3'-0"TOP END WALL PEAK TOP OF SLAB STANDING SEAM METAL ROOF BEYOND 16'-9"TOP END WALL PEAK TOP OF SLAB11'-5"BEYOND BRICK VENEER 10'-0"CEILING HT. BRICK VENEER BRICK VENEER BRICK VENEER BRICK VENEER GUTTER / FASCIA 192 EAST ELEVATION STANDING SEAM METAL ROOF BEYOND 16'-9"TOP END WALL PEAK TOP OF SLAB 11'-5"CANTILEVERED METAL CANOPY BRICK VENEER 10'-0"CEILING HT. METAL CAP FLASHINGMETAL CAP FLASHING METAL CAP FLASHING PAINTED METAL DOOR AND FRAME -RANDOM BRICK PROTRUSIONS SAME AS FACE BRICK COLOR METAL CAP FLASHING 12" PIN MOUNTED ADDRESS NUMBER WITH 1" STROKE (CLEAR ANODIZED ALUMINUM) RANDOM BRICK PROTRUSIONS SAME AS FACE BRICK COLOR BEYOND CANTILEVERED METAL CANOPY IN BLACK FRAME IN BLACK FRAME (CLEAR ANODIZED ALUMINUM) NOTE: SEE SUBMITTED SAMPLE BOARD FOR ACTUAL MATERIALS AND COLORS. METAL CAP FLASHING NOT F O R C O N S T R U C TI O N DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY NOTE : 60% GLASS THIS FACADE NOTE : 46% GLASS THIS FACADE D E S I G N A R C H I T E C T U R E I N T E R I O R NIGEDS NIGEDSGRAPHIC HCLA E M Y DESIGN ALCHEMY, L.L.C. COMMENTSDATENO. PROJECT NO.: DATE: CHECKED BY: DRAWN BY: TITLE: ISSUE LOG: SHEET NUMBER: XX-XXXX JUNE 20, 2016 JHW JHWGRAYSTONE CONSTRUCTION192 SOUTHWESTERN BLVDCCOPPELL, TEXAS 750191 02-05-25 P&Z SUBMITTAL PL-2L EXTERIOR ELEVATIONS 21 NTS EXTERIOR RENDERING1 D E S I G N A R C H I T E C T U R E I N T E R I O R NIGEDS NIGEDSGRAPHIC HCLA E M Y DESIGN ALCHEMY, L.L.C. COMMENTSDATENO. PROJECT NO.: DATE: CHECKED BY: DRAWN BY: TITLE: ISSUE LOG: SHEET NUMBER: XX-XXXX JUNE 20, 2016 JHW JHWGRAYSTONE CONSTRUCTION192 SOUTHWESTERN BLVDCOPPELL, TEXAS 750191 07/01/24 BLDG RENDERING RENDERING BUILDING RENDERING 22 EXISTING OVERHEAD BRICK VENEER WAINSCOT EXISTING METAL SIDING EXISTING GUTTER SOUTH ELEVATION DOOR EAST ELEVATION NORTH ELEVATION EXISTING METAL SIDING4'-0"BRICK VENEER WAINSCOT4'-0"4'-0"BRICK VENEER WAINSCOT EXISTING METAL SIDING 8'-0" WOOD PERIMETER FENCE WEST ELEVATION EXISTING METAL SIDING NOT F O R C O N S T R U C TI O N DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY DARK GRAY16'-0"16'-0"16'-0"16'-0" NOTE : 27% BRICK MASONRY PER FACADE 72% EXISTING METAL SIDING PER FACADE D E S I G N A R C H I T E C T U R E I N T E R I O R NIGEDS NIGEDSGRAPHIC HCLAE M Y DESIGN ALCHEMY, L.L.C. COMMENTSDATENO. PROJECT NO.: DATE: CHECKED BY: DRAWN BY: TITLE: ISSUE LOG: SHEET NUMBER: XX-XXXX JUNE 20, 2016 JHW JHWGRAYSTONE CONSTRUCTION192 SOUTHWESTERN BLVDCCOPPELL, TEXAS 750191 02/05/25 P&Z SUBMITTAL PZ-2A EXISTING WAREHOUSE ELEVATIONS 23 24 FLOOR PLAN NORTH PROPERTY LOCATED AT 192 SOUTHWESTERN BOULEVARD, IN THE CITY OF COPPELL, TEXAS AND DESCRIBED AS LOT NO. 2 OF NORTH LAKE ESTATES, AN ADDITION TO THE CITY OF COPPELL, DALLAS COUNTY, TEXAS ACCORDING THE MAP THEREOF RECORDED ON VOLUME 45, AT PAGE 65 OF THE MAP RECORDS OF DALLAS COUNTY, TEXAS. LEGAL DISCRIPTION NOT F O R C O N S T R U C TI O N EXISTING WAREHOUSE PARKING 2 SOUTHWESTERNBLVDHOWELL DRIVE 30'-0" BUILDING SETBACK 24'-0" DRIVE AISLE PROPERTY LINE 75.00'PROPERTY LINE 75.01'PROPERTY LINE 134.66' PROPERTY LINE 134.00'EXISTING ALLEYFENCEFENCEFENCEFENCE CONCRETE DRIVEWAY EXISTING WAREHOUSE DRIVEWAY HC LOADING ZONE HC VAN PARKING 1 PARKING 3 PARKING 4 PARKING 5 20'-0"15'-0"30'-0" BUILDING SETBACKSIDEWALK15'-0"RESTROOM RESTROOM CONFERENCE PARTNER OFFICE PARTNER OFFICE OFFICE OFFICE REFRIG WAITING GALLEY ESTIMATING / COPIERFILES FILES FILES FILES FILES FILES FILES FILES FENCELANDSCAPED AREA LANDSCAPED AREA 15'-0" ABANDONED ALLEY ADJACENT PROPERTY LINEPARKING 6 36'-0"5'-0"11'-0"20'-0"9'-0"20'-0"10'-0"LANDSCAPED AREA 5'-0"REFUGE BINS WILL BE KEPT INSIDE WAREHOUSE AND ROLLED OUT ON PICK-UP DAYS D E S I G N A R C H I T E C T U R E I N T E R I O R NIGEDS NIGEDSGRAPHIC HCLAE M Y DESIGN ALCHEMY, L.L.C. COMMENTSDATENO. PROJECT NO.: DATE: CHECKED BY: DRAWN BY: TITLE: ISSUE LOG: SHEET NUMBER: XX-XXXX JUNE 20, 2016 JHW JHWGRAYSTONE CONSTRUCTION192 SOUTHWESTERN BLVDCCOPPELL, TEXAS 750191 02/05/25 P&Z SUBMITTAL PZ-1A FLOOR PLAN 25 February 5, 2025 Revised: February 6, 2025 1300 S. Polk Street Suite 160-B Dallas, Texas 75224 214.893.7543 f. 214.941.9988 A R C H I T E C T U R E I N TE RI O R DE SI G N G R A P H I C D E S I G N Graystone Construction 192 Southwestern Boulevard Coppell, Texas 75019 Plan Number: PD25-01-000857 PROPOSED PROVISIONS for ZONING APPROVAL The following are issues for consideration and the property Owner’s commitment concessions presented to the City of Coppell – Planning and Zoning for approval. 1. To prevent commercial vehicles from parking on the street and/or on the property the Owner will post “NO COMMERCIAL VEHICLES” signage on the Owner’s property along Howell Street. 2. The existing warehouse on the property has been a viable functioning facility for over 40 years. The warehouse has existing utilities (water, sewer, gas and electrical services). 3. The existing warehouse is currently listed in the Dallas County Central Appraisal District as a taxable structure. 4. The Owner has already invested $50K in significant improvements to the existing warehouse to improve the aesthetic street appeal as well as added energy saving insulation. 5. To further enhance the existing warehouse building the Owner will install a 4’-0” high brick wainscot around the North, South and East sides. The wainscot will match the brick used on the new office Building. See submitted warehouse exterior elevations. 6. It is noted that there is a 15’ wide abandoned alley on the North side of the property with no property line abutting a neighboring property See hashed area on the plan. 7. The previously proposed outside trailer parking has been removed from the West end of the existing warehouse and is now showing as a one vehicle parking space. If needed trailers will be parked inside the warehouse or on a site outside the City of Coppell. 26 ITEM 10 Page 1 of 3 CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT PD-323-HC, Coppell Entertainment Plaza, Lot 1, Block A, P&Z HEARING DATE: February 20, 2025 CITY COUNCIL HEARING DATE: March 11, 2025 STAFF REP.: Matthew Steer, AICP, Development Services Administrator LOCATION: North side of State Highway 121, approximately 940 feet west of N Denton Tap Road SIZE OF AREA: 1.6 acres of property CURRENT ZONING: Highway Commercial (HC) REQUEST: Zoning change request from HC (Highway Commercial) to PD-323-HC (Planned Development 323-Highway Commercial) to allow for a Detail Site Plan for a building containing five (5) pickleball courts (13,000-sf) with a speculative restaurant (2,485-sf) and retail space (2,170-sf), totaling 17,655-sf. APPLICANT: Owner Owner’s Representative/Engineer Jinting Chen Lindey Mayer, P.E. Coppell PKB LLC Dynamic Engineering Consultants, PC 3120 Golden Springs Drive 714 S Greenville Avenue, Suite 100 Plano, Texas 75025 Allen, Texas 75002 972-302-7625 972-534-2100 JasonC@IndoorPickleballNow.com LMayer@DynamicEC.com HISTORY: This property has never been platted. The zoning was changed from Light Industrial to Highway Commercial District in 2004. HISTORIC COMMENT: This property has no historic significance. TRANSPORTATION: State Highway 121 and frontage road. SURROUNDING LAND USE & ZONING: North: Residential, Coppell Greens; Planned Development-134R-Single Family-7 South: Residential, Magnolia Park; Planned Development-133R-Single Family-9 East: LA Fitness; Planned Development-240R3-Highway Commercial West: Medical Office; Highway Commercial 29 ITEM 10 Page 2 of 3 COMPREHENSIVE PLAN: Coppell 2030, A Comprehensive Master Plan, shows this land as appropriate for Freeway Special District use. DISCUSSION: Site Plan The Site Plan for Coppell Entertainment Plaza consists of a one-story building containing five pickleball courts (13,000-sf) with speculative restaurant (2,485-sf) and retail space (2,170-sf), totaling 17,655-sf. The site has four shared mutual access/fire lanes connecting it to the east and west properties. There are 66 parking spaces required and 73 parking spaces proposed. As calculated, this plan shows six parking spaces for each pickleball court (five courts, 13,000-sf), 25 parking spaces for the speculative 2,485-sf restaurant at one parking space per 100 square feet and 11 parking spaces for the speculative 2,170-sf retail space. The current layout of the building is depicted in the attached floor plan. A six-foot masonry screening wall is proposed to be constructed on the north property line, adjacent to the Coppell Greens residential subdivision. The screening wall will be required to be constructed prior to the buildings going vertical. There is a detention area west of the proposed building with a tie-in the TXDOT drainage system. TxDOT’s approval is listed as a condition of staff’s recommendation. Landscape Plan The Landscape Plan is compliant with the total landscape area requirements of the Landscape Section of the Zoning Ordinance. The total landscape area required is 21,101-sf, which is 30% of the total site area. Depicted is 17,810-sf (25%) of landscape area and 6,262-sf of enhanced paving (8%). The Ordinance allows for up to 5% of the total required landscape area to be enhanced pavement: therefore, the applicant is meeting the minimum 30% requirement with the enhanced paving included. According to the Tree Survey, nine protected trees are proposed to be removed and four protected trees are proposed to be preserved. The tree mitigation required for this site is $1,660. There are 40, 3” caliper overstory trees required and 25, 4” caliper overstory trees proposed to be planted. These consist of 12 Big Tooth Maples, five Lacey Oaks, three Bald Cypress, and five Cedar Elms. In addition, there are seven, 2.5” caliper Chinese Pistache proposed. These will need to be increased in size to a minimum 3 caliper inches to meet the minimum requirements of the Ordinance. This is listed as a condition within staff’s recommendation. Also, there are 21 accent trees shown (10 red and 11 white Crape Myrtles). At a ratio of three to one, these can be counted toward fulfilling the requirement of an overstory tree (seven overstory trees). These are being utilized in certain locations to minimize the impacts on existing utilities. 30 ITEM 10 Page 3 of 3 Building Elevations, Lighting & Signage The proposed metal building is 23’ in height and clad with grey stucco and stone. It is proposed to have a grey standing seam roof. Grey metal canopies are proposed on the south elevation at each entry. A Photometric Study and Lighting Plan was submitted and appears to be in compliance with the provisions of the Zoning Ordinance. This information will be reviewed at the time of Building Permit. All signage for the site will be required to comply with ordinance requirements. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff is recommending APPROVAL of PD-323-HC, Coppell Entertainment Plaza, subject to the following conditions: 1. TxDOT will be required to approve the tie-in to their stormwater system. 2. There will be additional comments at the time of Detail Engineering Review and Building Permit. 3. A plat will be required to be filed of record prior to permitting. 4. All attached building signage shall comply with the Sign Section of the Zoning Ordinance. 5. The seven Chinese Pistache proposed will need to be increased in size to a minimum 3 caliper inches to meet the minimum requirements of the Ordinance. 6. Rectify the discrepancies between what is shown in the rendering and the elevations. 7. The six-foot screening wall will be required to be constructed prior to the buildings going vertical. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: 1. Recommend approval of the request 2. Recommend disapproval of the request 3. Recommend modification of the request 4. Take under advisement for reconsideration at a later date ATTACHMENTS: 1. Site Plan 2. Landscape Plan & Tree Survey 3. Elevations, Details & Rendering 4. Floor Plan 5. Photometric Plan 31 LINDSEY G. MAYER ã www.dynamicec.comwww.dynamicec.com LAND DEVELOPMENT CONSULTING ● PERMITTING GEOTECHNICAL ● ENVIRONMENTAL TRAFFIC ● SURVEY ● PLANNING & ZONING Offices conveniently located throughout the United States: New Jersey | Delaware | Florida | Maryland | Pennsylvania | Texas (dba) MIDWEST DYNAMIC ENGINEERING CONSULTANTS, PC714 S. Greenville AvenueSuite 100Allen, TX 75002 T: 972.534.2100 Texas Registered Engineering Firm No. F-13660 · · · · 32 ZONE: HC (HIGHWAYCOMMERCIAL)ZONE: SF-7ZONE: SF-7ZONE: SF-7ZONE: SF-7METALEDGE; TYP.METALEDGE; TYP.METALEDGE;TYP.10' LANDSCAPEBUFFERMETAL EDGE; TYP.ITITITITPT (E)PT (E)PT (E)PT (E)PT (E)PT (E)PT (E)ITPT (N)ITITPT (N)PW (W)ITOTITOTITITITPT (N)PT (N)PT (N)PT (N)PT (N)PT (N)PT (N)PT (N)PT (N)PT (N)7HPY2UC1QG12SGA26IVN18ARC4HPY1QG4HPY4HPY1QG1QG4HPY1QG27IVN4HPY15ARC13MLL43ICN4AG2PC3UC7AG29MPMENHANCEDPAVING; REFERTO CIVILPW (W)PW (W)PW (W)PT (N)PT (N)R.O.W T (11)OTOTOTOTOTOTOTOTOT6LIG6LID15SGAOTOTOTPW (W)R.O.W T12LID12LIG13ARC4TD(dba) MIDWEST DYNAMIC ENGINEERING CONSULTANTS, PC714 S. Greenville AvenueSuite 100Allen, TX 75002T: 972.534.2100Texas Registered Engineering Firm No. F-13660www.dynamicec.comwww.dynamicec.comLAND DEVELOPMENT CONSULTING ● PERMITTINGGEOTECHNICAL ● ENVIRONMENTALTRAFFIC ● SURVEY ● PLANNING & ZONINGOffices conveniently located throughout the United States:New Jersey | Delaware | Florida | Maryland | Pennsylvania | Texas02/12/2025LANDSCAPE ARCHITECTURELAND PLANNING · IRRIGATION DESIGN800.680.6630www.evergreendesigngroup.comNational Presence. Local Expertise.EVERGREEN DESIGN GROUP020'40'1" = 20'-0"NORTHROOT BARRIERSIRRIGATION CONCEPTPLANTING & IRRIGATION GUARANTEEPLANT SCHEDULETHE CONTRACTOR SHALL INSTALL ROOT BARRIERS NEAR ALL NEWLY-PLANTED TREESTHAT ARE LOCATED WITHIN FIVE (5) FEET OF PAVING OR CURBS. ROOT BARRIERSSHALL BE "CENTURY" OR "DEEP-ROOT" 24" DEEP PANELS (OR EQUAL). BARRIERS SHALLBE LOCATED IMMEDIATELY ADJACENT TO HARDSCAPE. INSTALL PANELS PERMANUFACTURER'S RECOMMENDATIONS. UNDER NO CIRCUMSTANCES SHALL THECONTRACTOR USE ROOT BARRIERS OF A TYPE THAT COMPLETELY ENCIRCLE THEROOTBALL.THE LANDSCAPE CONTRACTOR SHALL GUARANTEE THAT ALL NEWLY INSTALLED ANDEXISTING PLANTS SHALL SURVIVE FOR ONE YEAR AFTER FINAL OWNER ACCEPTANCEOF THE INSTALLATION WORK. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FORAPPROPRIATE WATERING OF THE LANDSCAPE THROUGH INSTALLATION OF APROPERLY DESIGNED IRRIGATION SYSTEM. THE OWNER SHALL APPROVE THE SYSTEMDESIGN BEFORE INSTALLATION OF PLANTS OR IRRIGATION.1.AN AUTOMATIC IRRIGATION SYSTEM SHALL BE INSTALLED AND OPERATIONAL BY THE TIME OF FINALINSPECTION. THE ENTIRE IRRIGATION SYSTEM SHALL BE INSTALLED BY A LICENSED AND QUALIFIED IRRIGATIONCONTRACTOR.2.THE IRRIGATION SYSTEM WILL OPERATE ON POTABLE WATER, AND THE SYSTEM WILL HAVE APPROPRIATEBACKFLOW PREVENTION DEVICES INSTALLED TO PREVENT CONTAMINATION OF THE POTABLE SOURCE.3.ALL NON-TURF PLANTED AREAS SHALL BE DRIP IRRIGATED. SODDED AND SEEDED AREAS SHALL BE IRRIGATEDWITH SPRAY OR ROTOR HEADS AT 100% HEAD-TO-HEAD COVERAGE.4.ALL PLANTS SHARING SIMILAR HYDROZONE CHARACTERISTICS SHALL BE PLACED ON A VALVE DEDICATED TOPROVIDE THE NECESSARY WATER REQUIREMENTS SPECIFIC TO THAT HYDROZONE.5.THE IRRIGATION SYSTEM SHALL BE DESIGNED AND INSTALLED, TO THE MAXIMUM EXTENT POSSIBLE, TOCONSERVE WATER BY USING THE FOLLOWING DEVICES AND SYSTEMS: MATCHED PRECIPITATION RATETECHNOLOGY ON ROTOR AND SPRAY HEADS (WHEREVER POSSIBLE), RAIN SENSORS, AND MULTI-PROGRAMCOMPUTERIZED IRRIGATION CONTROLLERS FEATURING SENSORY INPUT CAPABILITIES.6.NO PERMANENT IRRIGATION SHALL BE INSTALLED WITHIN THE PUBLIC RIGHT-OF-WAY. WHERE REQUIRED,R.O.W. IRRIGATION SHALL BE TEMPORARY AND REMOVED WITHIN ONE YEAR ONCE THE LANDSCAPE HAS BEENESTABLISHED.LANDSCAPE PLANLANDSCAPE CALCULATIONSTOTAL SITE AREA:70,388 SF (1.61 AC)BUILDING AREA:17,655 SFPAVING AREA:30,158 SFTOTAL LANDSCAPE AREA REQUIRED:21,101 SF (30%)TOTAL LANDSCAPE AREA PROVIDED:17,810 SF (25%)PROPOSED ENHANCED PAVING TOTAL:6,262 SF (8%)PROPOSED ENHANCED PAVING*:3,519 SF (5%)*ENHANCED PAVING TO ACCOUNT FOR LANDSCAPE DEFICIT. REFER TO CIVIL. REFER TO CODE 12-34-10.PARKING LOT LANDSCAPINGINTERIOR LANDSCAPINGREQUIREDPROVIDED10% OF THE PAVING AREAREQUIRED: 3,016 SF (10%)30,158 SF x 10% = 3,016 SFPROVIDED:3,037 SF (10%)ISLAND & PARKING LOT TREES REQUIRED:1 TREE / 400 SF, 1 TREE PER ISLAND, 1 TREE AT EACH TERMINUS ISLANDMIN. TREES REQUIRED:3,016 SF / 400 SF - 7.54 TREESPARKING LOT ISLAND & TERMINUS ISLANDS:12 ISLANDSTOTAL TREES REQUIRED: 12 TREESPROVIDED:12 TREESPERIMETER LANDSCAPINGPUBLIC R.O.W. - VEHICULAR USE AREAS (VUA)PERIMETER LANDSCAPE AREA 15' WIDE:15' / 2,552 SFPROPERTY LINES 10' WIDEPERIMETER LANDSCAPE AREA TOTAL:10' / 6,587 SFN PERIMETER:10' / 2,774 SFE PERIMETER:10' / 2,156 SFW PERIMETER:10' / 1,657 SFTREES REQUIRED:1 TREE PER 50 LFR.O.W. PERIMETER: 12 UNDERSTORY TREES159' LF/50 = 3.18 TREES (4)N PERIMETER: 2 OVERSTORY TREES (1 PROPOSED + 1 EXISTING)272' LF/50 = 5.44 TREES (6)12 UNDERSTORY TREES*E PERIMETER:7 OVERSTORY TREES329' LF/50 = 6.58 TREES (7)W PERIMETER:5 OVERSTORY TREES250' LF/50 = 5 TREES (5)SHRUBS REQUIRED:30" CONTINUOUS HEDGEPROVIDED AS REQUIREDNON-VEHICULAR OPEN SPACE (NVOS)FEATURE LANDSCAPINGREQUIREDPROVIDEDNVOS AREA:SITE AREA - BUILDING FOOTPRINT70,388 SF - 17,655 SF = 52,733 SF15% OF NVOS LANDSCAPE AREA REQUIRED:7,910 SF (15%)52,733 SF x 15% = 7,910 SFNVOS LANDSCAPE AREA PROVIDED:5,634 SF (11%)17,810 SF - 9,139 SF- 3,037 SF = 5,634 SF(OVERALL LA - BUFFER LA - INTERNAL LA)50% SHALL BE IN REQ. FRONT YARD7,910 SF SF x 50% = 3,955 SF1,843 SF (23.2%)OPEN SPACE TREES REQUIRED:PERCENTAGE OF NVOS LANDSCAPE AREA / NVOS AREA14,773 SF / 52,733 = 28%1 TREE / 2,500 SF (UNDER 30%, PER CHART SEC. 12-34-9)14,773 / 2,500 SF = 5.9 TREES (6)TREES PROVIDED:2 OVERSTORY TREES12 UNDERSTORY TREES*___________________________________________________________________________________TOTAL TREES REQUIRED = 40 TREES63 TREES PROVIDED(27 OVERSTORY, 36 ACCENT, 1 EXISTING)*NOTE:1. UNDERSTORY TREES PROPOSED DUE TO ENCROACHMENT ON EASEMENTS & UTILITY LOCATIONS. 1.a. REFER TO TREE KEY FOR REFERENCE. 1.b 3:1 UNDERSTORY TO OVERSTORY TREE RATIO PER CITY REQUIREMENT.SYMBOLCODEBOTANICAL NAMECOMMON NAMESIZEQTYREMARKSACCENT TREELIDLagerstroemia indica 'Dallas Red'Dallas Red Crape Myrtle2.5" Cal.107' MIN. HT.LIGLagerstroemia indica 'Glendora White"White Crape Myrtle2.5" Cal.117' MIN. HT.OVERSTORY/CANOPYAGAcer grandidentatum x saccharumBig Tooth Maple4" Cal.127' MIN. HT.PCPistacia chinensisChinese Pistache2.5" Cal.77' MIN. HT.QGQuercus glaucoidesLacey Oak4" Cal.57' MIN. HT.TDTaxodium distichumBald Cypress4" Cal.37' MIN. HT.UCUlmus crassifoliaCedar Elm4" Cal.57' MIN. HT.LARGE SHRUBSICNIlex cornuta 'Burfordii Nana'Dwarf Burford Holly5 gal.4330" MIN. HT.IVNIlex vomitoria 'Nana'Dwarf Yaupon Holly5 gal.5330" MIN. HT.MPMMyrica pusillaDwarf Wax Myrtle5 gal.2930" MIN. HT.ORNAMENTAL GRASSESMLLMuhlenbergia lindheimeriLindheimer's Muhly1 gal.1318" MIN. HT.SMALL SHRUBSARCAbelia x `Rose Creek`Rose Creek Abelia3 gal.4624" MIN. HT.HPYHesperaloe parvifloraRed Yucca3 gal.2724" MIN. HT.SGASalvia greggiiAutumn Sage3 gal.2724" HT. MIN.SYMBOLCODEBOTANICAL NAMECOMMON NAMESIZESPACINGQTYREMARKSSOD/SEEDTRFCynodon dactylon x transvaalensis `DT-1`TifTuf™ Bermudagrasssod11,297 sfLEGENDEXISTING TREES OR PALMSTO BE PRESERVED &PROTECTED IN PLACETREE PROTECTIONFENCEEXISTING TREES OR PALMSOUTSIDE OF PROPERTY LINELP-1MULCHESAFTER ALL PLANTING IS COMPLETE, CONTRACTOR SHALL INSTALL 3" THICK LAYER OF1-1/2" SHREDDED WOOD MULCH, NATURAL (UNDYED), OVER LANDSCAPE FABRIC IN ALLPLANTING AREAS (EXCEPT FOR TURF AND SEEDED AREAS). CONTRACTOR SHALL SUBMITSAMPLES OF ALL MULCHES TO LANDSCAPE ARCHITECT AND OWNER FOR APPROVALPRIOR TO CONSTRUCTION. ABSOLUTELY NO EXPOSED GROUND SHALL BE LEFTSHOWING ANYWHERE ON THE PROJECT AFTER MULCH HAS BEEN INSTALLED (SUBJECTTO THE CONDITIONS AND REQUIREMENTS OF THE "GENERAL GRADING AND PLANTINGNOTES" AND SPECIFICATIONS).*REFER TO TD-1 FOR MORE INFORMATION..HIAENSSTE HCCTTES A P ETSTAIREG 03OF47ETX LRLDR E CAANDSWEPAESETS TREE MITIGATION:162" TOTAL INCHES104" TO BE REMOVED58" TO REMAIN1. 58" / 162" = 35.8% TREE PRESERVATION CREDIT1.a. 35.8% x 104" = 37.2" TO BE MITIGATED.2. LANDSCAPE CREDIT CAN BE GIVEN TO SATISFY UP TO 50% OF THE 37.2" (16.6").2. a. LANDSCAPE PLAN SHOWS MORE THAN 16.6".3. THE REMAINING 16.6" TO BE PAID IN LIEU OF TREE REPLACEMENT TO THE CITY OFCOPPELL REFORESTATION AND NATURAL AREAS FUND AT $100.00 PER ONE INCHDBH FOR TREES LESS THAN 12 INCHES DBH AND $200 PER ONE INCH DBH FOR TREESOVER 12 INCHES DBH.3.a. (16.6" x $100.00 = $1,660.00 TOTAL FEE)TREE KEYPARKING LOT LANDSCAPING:IT - PARKING LOT ISLAND TREEPERIMETER LANDSCAPING:R.O.W T - R.O.W PERIMETER TREEPT N - NORTH PERIMETER TREEPT E - EAST PERIMETER TREEPT W - WEST PERIMETER TREENON-VEHICULAR OPEN SPACE LANDSCAPING:OT - OPEN SPACE TREETREE MITIGATION:MT - MITIGATION TREE33 GENERALA.QUALIFICATIONS OF LANDSCAPE CONTRACTOR1.ALL LANDSCAPE WORK SHOWN ON THESE PLANS SHALL BE PERFORMED BY A SINGLE FIRM SPECIALIZING INLANDSCAPE PLANTING.2.A LIST OF SUCCESSFULLY COMPLETED PROJECTS OF THIS TYPE, SIZE AND NATURE MAY BE REQUESTED BY THEOWNER FOR FURTHER QUALIFICATION MEASURES.3.THE LANDSCAPE CONTRACTOR SHALL HOLD A VALID NURSERY AND FLORAL CERTIFICATE ISSUED BY THE TEXASDEPARTMENT OF AGRICULTURE, AS WELL AS OPERATE UNDER A COMMERCIAL PESTICIDE APPLICATOR LICENSEISSUED BY EITHER THE TEXAS DEPARTMENT OF AGRICULTURE OR THE TEXAS STRUCTURAL PEST CONTROL BOARD.B.SCOPE OF WORK1.WORK COVERED BY THESE SECTIONS INCLUDES THE FURNISHING AND PAYMENT OF ALL MATERIALS, LABOR,SERVICES, EQUIPMENT, LICENSES, TAXES AND ANY OTHER ITEMS THAT ARE NECESSARY FOR THE EXECUTION,INSTALLATION AND COMPLETION OF ALL WORK, SPECIFIED HEREIN AND / OR SHOWN ON THE LANDSCAPE PLANS,NOTES, AND DETAILS.2.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES AND REGULATIONS REQUIREDBY AUTHORITIES HAVING JURISDICTION OVER SUCH WORK, INCLUDING ALL INSPECTIONS AND PERMITS REQUIRED BYFEDERAL, STATE AND LOCAL AUTHORITIES IN SUPPLY, TRANSPORTATION AND INSTALLATION OF MATERIALS.3.THE LANDSCAPE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITY LINES (WATER, SEWER,ELECTRICAL, TELEPHONE, GAS, CABLE, TELEVISION, ETC.) PRIOR TO THE START OF ANY WORK.PRODUCTSA.ALL MANUFACTURED PRODUCTS SHALL BE NEW.B.CONTAINER AND BALLED-AND-BURLAPPED PLANTS:1.FURNISH NURSERY-GROWN PLANTS COMPLYING WITH ANSI Z60.1-2014. PROVIDE WELL-SHAPED, FULLY BRANCHED,HEALTHY, VIGOROUS STOCK FREE OF DISEASE, INSECTS, EGGS, LARVAE, AND DEFECTS SUCH AS KNOTS, SUN SCALD,INJURIES, ABRASIONS, AND DISFIGUREMENT. ALL PLANTS WITHIN A SPECIES SHALL HAVE SIMILAR SIZE, AND SHALL BEOF A FORM TYPICAL FOR THE SPECIES. ALL TREES SHALL BE OBTAINED FROM SOURCES WITHIN 200 MILES OF THEPROJECT SITE, AND WITH SIMILAR CLIMACTIC CONDITIONS.2.ROOT SYSTEMS SHALL BE HEALTHY, DENSELY BRANCHED ROOT SYSTEMS, NON-POT-BOUND, FREE FROM ENCIRCLINGAND/OR GIRDLING ROOTS, AND FREE FROM ANY OTHER ROOT DEFECTS (SUCH AS J-SHAPED ROOTS).3.ANY PLANT DEEMED UNACCEPTABLE BY THE LANDSCAPE ARCHITECT OR OWNER SHALL BE IMMEDIATELY REMOVEDFROM THE SITE AND SHALL BE REPLACED WITH AN ACCEPTBLE PLANT OF LIKE TYPE AND SIZE AT THE CONTRACTOR'SOWN EXPENSE. ANY PLANTS APPEARING TO BE UNHEALTHY, EVEN IF DETERMINED TO STILL BE ALIVE, SHALL NOT BEACCEPTED. THE LANDSCAPE ARCHITECT AND OWNER SHALL BE THE SOLE JUDGES AS TO THE ACCEPTABILITY OFPLANT MATERIAL.4.ALL TREES SHALL BE STANDARD IN FORM, UNLESS OTHERWISE SPECIFIED. TREES WITH CENTRAL LEADERS WILL NOTBE ACCEPTED IF LEADER IS DAMAGED OR REMOVED. PRUNE ALL DAMAGED TWIGS AFTER PLANTING.5.CALIPER MEASUREMENTS FOR STANDARD (SINGLE TRUNK) TREES SHALL BE AS FOLLOWS: SIX INCHES ABOVE THEROOT FLARE FOR TREES UP TO AND INCLUDING FOUR INCHES IN CALIPER, AND TWELVE INCHES ABOVE THE ROOTFLARE FOR TREES EXCEEDING FOUR INCHES IN CALIPER.6.MULTI-TRUNK TREES SHALL BE MEASURED BY THEIR OVERALL HEIGHT, MEASURED FROM THE TOP OF THE ROOT BALL.7.ANY TREE OR SHRUB SHOWN TO HAVE EXCESS SOIL PLACED ON TOP OF THE ROOT BALL, SO THAT THE ROOT FLAREHAS BEEN COMPLETELY COVERED, SHALL BE REJECTED.C.SOD: PROVIDE WELL-ROOTED SOD OF THE VARIETY NOTED ON THE PLANS. SOD SHALL BE CUT FROM HEALTHY, MATURETURF WITH SOIL THICKNESS OF 3/4" TO 1". EACH PALLET OF SOD SHALL BE ACCOMPANIED BY A CERTIFICATE FROMSUPPLIER STATING THE COMPOSITION OF THE SOD.D.SEED: PROVIDE BLEND OF SPECIES AND VARIETIES AS NOTED ON THE PLANS, WITH MAXIMUM PERCENTAGES OF PURITY,GERMINATION, AND MINIMUM PERCENTAGE OF WEED SEED AS INDICATED ON PLANS. EACH BAG OF SEED SHALL BEACCOMPANIED BY A TAG FROM THE SUPPLIER INDICATING THE COMPOSITION OF THE SEED.E.TOPSOIL: SANDY TO CLAY LOAM TOPSOIL, FREE OF STONES LARGER THAN ½ INCH, FOREIGN MATTER, PLANTS, ROOTS, ANDSEEDS.F.COMPOST: WELL-COMPOSTED, STABLE, AND WEED-FREE ORGANIC MATTER, pH RANGE OF 5.5 TO 8; MOISTURE CONTENT 35TO 55 PERCENT BY WEIGHT; 100 PERCENT PASSING THROUGH 3/4-INCH SIEVE; SOLUBLE SALT CONTENT OF 5 TO 10DECISIEMENS/M; NOT EXCEEDING 0.5 PERCENT INERT CONTAMINANTS AND FREE OF SUBSTANCES TOXIC TO PLANTINGS.NO MANURE OR ANIMAL-BASED PRODUCTS SHALL BE USED.G.FERTILIZER: GRANULAR FERTILIZER CONSISTING OF NITROGEN, PHOSPHORUS, POTASSIUM, AND OTHER NUTRIENTS INPROPORTIONS, AMOUNTS, AND RELEASE RATES RECOMMENDED IN A SOIL REPORT FROM A QUALIFIED SOIL-TESTINGAGENCY (SEE BELOW).H.MULCH: SIZE AND TYPE AS INDICATED ON PLANS, FREE FROM DELETERIOUS MATERIALS AND SUITABLE AS A TOP DRESSINGOF TREES AND SHRUBS.I.WEED FABRIC: 5 OUNCE, WOVEN, NEEDLE-PUNCHED FABRIC, SUCH AS DEWITT PRO5 LANDSCAPE FABRIC (OR APPROVEDEQUAL).J.TREE STAKING AND GUYING1.STAKES: 6' LONG GREEN METAL T-POSTS.2.GUY AND TIE WIRE: ASTM A 641, CLASS 1, GALVANIZED-STEEL WIRE, 2-STRAND, TWISTED, 0.106 INCH DIAMETER.3.STRAP CHAFING GUARD: REINFORCED NYLON OR CANVAS AT LEAST 1-1/2 INCH WIDE, WITH GROMMETS TO PROTECTTREE TRUNKS FROM DAMAGE.M.STEEL EDGING: PROFESSIONAL STEEL EDGING, 10 GAUGE THICK X 4 INCHES WIDE, FACTORY PAINTED DARK GREEN.ACCEPTABLE MANUFACTURERS INCLUDE COL-MET OR APPROVED EQUAL.N.PRE-EMERGENT HERBICIDES: ANY GRANULAR, NON-STAINING PRE-EMERGENT HERBICIDE THAT IS LABELED FOR THESPECIFIC ORNAMENTALS OR TURF ON WHICH IT WILL BE UTILIZED. PRE-EMERGENT HERBICIDES SHALL BE APPLIED PER THEMANUFACTURER'S LABELED RATES.METHODSA.SOIL PREPARATION1.BEFORE STARTING WORK, THE LANDSCAPE CONTRACTOR SHALL VERIFY THAT THE GRADE OF ALL LANDSCAPE AREASARE WITHIN +/-0.1' OF FINISH GRADE. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY SHOULD ANYDISCREPANCIES EXIST.2.SOIL TESTING:a.AFTER FINISH GRADES HAVE BEEN ESTABLISHED, CONTRACTOR SHALL HAVE SOIL SAMPLES TESTED BY ANESTABLISHED SOIL TESTING LABORATORY FOR THE FOLLOWING: SOIL TEXTURAL CLASS, GENERAL SOILFERTILITY, pH, ORGANIC MATTER CONTENT, SALT (CEC), LIME, SODIUM ADSORPTION RATIO (SAR) AND BORONCONTENT. EACH SAMPLE SUBMITTED SHALL CONTAIN NO LESS THAN ONE QUART OF SOIL.b.CONTRACTOR SHALL ALSO SUBMIT THE PROJECT'S PLANT LIST TO THE LABORATORY ALONG WITH THE SOILSAMPLES.c.THE SOIL REPORT PRODUCED BY THE LABORATORY SHALL CONTAIN RECOMMENDATIONS FOR THE FOLLOWING(AS APPROPRIATE): GENERAL SOIL PREPARATION AND BACKFILL MIXES, PRE-PLANT FERTILIZER APPLICATIONS,AND ANY OTHER SOIL RELATED ISSUES. THE REPORT SHALL ALSO PROVIDE A FERTILIZER PROGRAM FOR THEESTABLISHMENT PERIOD AND FOR LONG-TERM MAINTENANCE.3.THE CONTRACTOR SHALL INSTALL SOIL AMENDMENTS AND FERTILIZERS PER THE SOILS REPORT RECOMMENDATIONS.ANY CHANGE IN COST DUE TO THE SOIL REPORT RECOMMENDATIONS, EITHER INCREASE OR DECREASE, SHALL BESUBMITTED TO THE OWNER WITH THE REPORT.4.FOR BIDDING PURPOSES ONLY, THE SOIL PREPARATION SHALL CONSIST OF THE FOLLOWING:a.TURF: INCORPORATE THE FOLLOWING AMENDMENTS INTO THE TOP 8" OF SOIL BY MEANS OF ROTOTILLINGAFTER CROSS-RIPPING:i.NITROGEN STABILIZED ORGANIC AMENDMENT - 4 CU. YDS. PER 1,000 S.F.ii.PREPLANT TURF FERTILIZER (10-20-10 OR SIMILAR, SLOW RELEASE, ORGANIC) - 15 LBS PER 1,000 S.F.iii."CLAY BUSTER" OR EQUAL - USE MANUFACTURER'S RECOMMENDED RATEb.TREES, SHRUBS, AND PERENNIALS: INCORPORATE THE FOLLOWING AMENDMENTS INTO THE TOP 8" OF SOIL BYMEANS OF ROTOTILLING AFTER CROSS-RIPPING:i.NITROGEN STABILIZED ORGANIC AMENDMENT - 4 CU. YDS. PER 1,000 S.F.ii.12-12-12 FERTILIZER (OR SIMILAR, ORGANIC, SLOW RELEASE) - 10 LBS. PER CU. YD.iii."CLAY BUSTER" OR EQUAL - USE MANUFACTURER'S RECOMMENDED RATEiv.IRON SULPHATE - 2 LBS. PER CU. YD.5.CONTRACTOR SHALL ENSURE THAT THE GRADE IN SOD AREAS SHALL BE 1" BELOW FINISH GRADE BEFORE INSTALLINGSOIL AMENDMENTS, AND 2" BELOW FINISH GRADE IN SHRUB AREAS BEFORE INSTALLING SOIL AMENDMENTS. MULCHCOVER WITHIN 6" OF CONCRETE WALKS AND CURBS SHALL NOT PROTRUDE ABOVE THE FINISH SURFACE OF THEWALKS AND CURBS. MULCH COVER WITHIN 12" OF WALLS SHALL BE AT LEAST 3" LOWER THAN THE TOP OF WALL.6.ONCE SOIL PREPARATION IS COMPLETE, THE LANDSCAPE CONTRACTOR SHALL ENSURE THAT THERE ARE NO DEBRIS,TRASH, OR STONES LARGER THAN 1" REMAINING IN THE TOP 6" OF SOIL.B.GENERAL PLANTING1.REMOVE ALL NURSERY TAGS AND STAKES FROM PLANTS.2.EXCEPT IN AREAS TO BE PLANTED WITH ORNAMENTAL GRASSES, APPLY PRE-EMERGENT HERBICIDES AT THEMANUFACTURER'S RECOMMENDED RATE.3.TRENCHING NEAR EXISTING TREES:a.CONTRACTOR SHALL NOT DISTURB ROOTS 1-1/2" AND LARGER IN DIAMETER WITHIN THE CRITICAL ROOT ZONE(CRZ) OF EXISTING TREES, AND SHALL EXERCISE ALL POSSIBLE CARE AND PRECAUTIONS TO AVOID INJURY TOTREE ROOTS, TRUNKS, AND BRANCHES. THE CRZ IS DEFINED AS A CIRCULAR AREA EXTENDING OUTWARD FROMTHE TREE TRUNK, WITH A RADIUS EQUAL TO 1' FOR EVERY 1" OF TRUNK DIAMETER-AT-BREAST-HEIGHT (4.5'ABOVE THE AVERAGE GRADE AT THE TRUNK).b.ALL EXCAVATION WITHIN THE CRZ SHALL BE PERFORMED USING HAND TOOLS. NO MACHINE EXCAVATION ORTRENCHING OF ANY KIND SHALL BE ALLOWED WITHIN THE CRZ.c.ALTER ALIGNMENT OF PIPE TO AVOID TREE ROOTS 1-1/2" AND LARGER IN DIAMETER. WHERE TREE ROOTS 1-1/2"AND LARGER IN DIAMETER ARE ENCOUNTERED IN THE FIELD, TUNNEL UNDER SUCH ROOTS. WRAP EXPOSEDROOTS WITH SEVERAL LAYERS OF BURLAP AND KEEP MOIST. CLOSE ALL TRENCHES WITHIN THE CANOPY DRIPLINES WITHIN 24 HOURS.d.ALL SEVERED ROOTS SHALL BE HAND PRUNED WITH SHARP TOOLS AND ALLOWED TO AIR-DRY. DO NOT USEANY SORT OF SEALERS OR WOUND PAINTS.C.TREE PLANTING1.TREE PLANTING HOLES SHALL BE EXCAVATED TO MINIMUM WIDTH OF TWO TIMES THE WIDTH OF THE ROOTBALL, ANDTO A DEPTH EQUAL TO THE DEPTH OF THE ROOTBALL LESS TWO TO FOUR INCHES.2.SCARIFY THE SIDES AND BOTTOM OF THE PLANTING HOLE PRIOR TO THE PLACEMENT OF THE TREE. REMOVE ANYGLAZING THAT MAY HAVE BEEN CAUSED DURING THE EXCAVATION OF THE HOLE.3.FOR CONTAINER AND BOX TREES, TO REMOVE ANY POTENTIALLY GIRDLING ROOTS AND OTHER ROOT DEFECTS, THECONTRACTOR SHALL SHAVE A 1" LAYER OFF OF THE SIDES AND BOTTOM OF THE ROOTBALL OF ALL TREES JUSTBEFORE PLACING INTO THE PLANTING PIT. DO NOT "TEASE" ROOTS OUT FROM THE ROOTBALL.4.INSTALL THE TREE ON UNDISTURBED SUBGRADE SO THAT THE TOP OF THE ROOTBALL IS TWO TO FOUR INCHESABOVE THE SURROUNDING GRADE.5.BACKFILL THE TREE HOLE UTILIZING THE EXISTING TOPSOIL FROM ON-SITE. ROCKS LARGER THAN 1" DIA. AND ALLOTHER DEBRIS SHALL BE REMOVED FROM THE SOIL PRIOR TO THE BACKFILL. SHOULD ADDITIONAL SOIL BE REQUIREDTO ACCOMPLISH THIS TASK, USE STORED TOPSOIL FROM ON-SITE OR IMPORT ADDITIONAL TOPSOIL FROM OFF-SITEAT NO ADDITIONAL COST TO THE OWNER. IMPORTED TOPSOIL SHALL BE OF SIMILAR TEXTURAL CLASS ANDCOMPOSITION IN THE ON-SITE SOIL.6.THE TOTAL NUMBER OF TREE STAKES (BEYOND THE MINIMUMS LISTED BELOW) WILL BE LEFT TO THE LANDSCAPECONTRACTOR'S DISCRETION. SHOULD ANY TREES FALL OR LEAN, THE LANDSCAPE CONTRACTOR SHALL STRAIGHTENTHE TREE, OR REPLACE IT SHOULD IT BECOME DAMAGED. TREE STAKING SHALL ADHERE TO THE FOLLOWINGGUIDELINES:a.1"-2" TREESTWO STAKES PER TREEb.2-1/2"-4" TREESTHREE STAKES PER TREEc.TREES OVER 4" CALIPERGUY AS NEEDEDd.MULTI-TRUNK TREESTHREE STAKES PER TREE MINIMUM, QUANTITY AND POSITIONS AS NEEDED TOSTABILIZE THE TREE7.UPON COMPLETION OF PLANTING, CONSTRUCT AN EARTH WATERING BASIN AROUND THE TREE. COVER THE INTERIOROF THE TREE RING WITH THE WEED BARRIER CLOTH AND TOPDRESS WITH MULCH (TYPE AND DEPTH PER PLANS).D.SHRUB, PERENNIAL, AND GROUNDCOVER PLANTING1.DIG THE PLANTING HOLES TWICE AS WIDE AND 2" LESS DEEP THAN EACH PLANT'S ROOTBALL. INSTALL THE PLANT INTHE HOLE. BACKFILL AROUND THE PLANT WITH SOIL AMENDED PER SOIL TEST RECOMMENDATIONS.2.INSTALL THE WEED BARRIER CLOTH, OVERLAPPING IT AT THE ENDS. UTILIZE STEEL STAPLES TO KEEP THE WEEDBARRIER CLOTH IN PLACE.3.WHEN PLANTING IS COMPLETE, INSTALL MULCH (TYPE AND DEPTH PER PLANS) OVER ALL PLANTING BEDS, COVERINGTHE ENTIRE PLANTING AREA.E.SODDING1.SOD VARIETY TO BE AS SPECIFIED ON THE LANDSCAPE PLAN.2.LAY SOD WITHIN 24 HOURS FROM THE TIME OF STRIPPING. DO NOT LAY IF THE GROUND IS FROZEN.3.LAY THE SOD TO FORM A SOLID MASS WITH TIGHTLY FITTED JOINTS. BUTT ENDS AND SIDES OF SOD STRIPS - DO NOTOVERLAP. STAGGER STRIPS TO OFFSET JOINTS IN ADJACENT COURSES.4.ROLL THE SOD TO ENSURE GOOD CONTACT OF THE SOD'S ROOT SYSTEM WITH THE SOIL UNDERNEATH.5.WATER THE SOD THOROUGHLY WITH A FINE SPRAY IMMEDIATELY AFTER PLANTING TO OBTAIN AT LEAST SIX INCHESOF PENETRATION INTO THE SOIL BELOW THE SOD.G.CLEAN UP1.DURING LANDSCAPE PREPARATION AND PLANTING, KEEP ALL PAVEMENT CLEAN AND ALL WORK AREAS IN A NEAT,ORDERLY CONDITION.2.DISPOSED LEGALLY OF ALL EXCAVATED MATERIALS OFF THE PROJECT SITE.H.INSPECTION AND ACCEPTANCE1.UPON COMPLETION OF THE WORK, THE LANDSCAPE CONTRACTOR SHALL PROVIDE THE SITE CLEAN, FREE OF DEBRISAND TRASH, AND SUITABLE FOR USE AS INTENDED. THE LANDSCAPE CONTRACTOR SHALL THEN REQUEST ANINSPECTION BY THE OWNER TO DETERMINE FINAL ACCEPTABILITY.2.WHEN THE INSPECTED PLANTING WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS, THE LANDSCAPECONTRACTOR SHALL REPLACE AND/OR REPAIR THE REJECTED WORK TO THE OWNER'S SATISFACTION WITHIN 24HOURS.3.THE LANDSCAPE MAINTENANCE PERIOD WILL NOT COMMENCE UNTIL THE LANDSCAPE WORK HAS BEEN RE-INSPECTEDBY THE OWNER AND FOUND TO BE ACCEPTABLE. AT THAT TIME, A WRITTEN NOTICE OF FINAL ACCEPTANCE WILL BEISSUED BY THE OWNER, AND THE MAINTENANCE AND GUARANTEE PERIODS WILL COMMENCE.I.LANDSCAPE MAINTENANCE1.THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL WORK SHOWN ON THESEPLANS FOR 90 DAYS BEYOND FINAL ACCEPTANCE OF ALL LANDSCAPE WORK BY THE OWNER. LANDSCAPEMAINTENANCE SHALL INCLUDE WEEKLY SITE VISITS FOR THE FOLLOWING ACTIONS (AS APPROPRIATE): PROPERPRUNING, RESTAKING OF TREES, RESETTING OF PLANTS THAT HAVE SETTLED, MOWING AND AERATION OF LAWNS,WEEDING, RESEEDING AREAS WHICH HAVE NOT GERMINATED WELL, TREATING FOR INSECTS ANDDISEASES,REPLACEMENT OF MULCH, REMOVAL OF LITTER, REPAIRS TO THE IRRIGATION SYSTEM DUE TO FAULTYPARTS AND/OR WORKMANSHIP, AND THE APPROPRIATE WATERING OF ALL PLANTINGS. THE LANDSCAPECONTRACTOR SHALL MAINTAIN THE IRRIGATION SYSTEM IN PROPER WORKING ORDER, WITH SCHEDULINGADJUSTMENTS BY SEASON TO MAXIMIZE WATER CONSERVATION.2. SHOULD SEEDED AND/OR SODDED AREAS NOT BE COVERED BY AN AUTOMATIC IRRIGATION SYSTEM, THELANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR WATERING THESE AREAS AND OBTAINING A FULL, HEALTHYSTAND OF GRASS AT NO ADDITIONAL COST TO THE OWNER.3.TO ACHIEVE FINAL ACCEPTANCE AT THE END OF THE MAINTENANCE PERIOD, ALL OF THE FOLLOWING CONDITIONSMUST OCCUR:a.THE LANDSCAPE SHALL SHOW ACTIVE, HEALTHY GROWTH (WITH EXCEPTIONS MADE FOR SEASONALDORMANCY). ALL PLANTS NOT MEETING THIS CONDITION SHALL BE REJECTED AND REPLACED BY HEALTHYPLANT MATERIAL PRIOR TO FINAL ACCEPTANCE.b.ALL HARDSCAPE SHALL BE CLEANED PRIOR TO FINAL ACCEPTANCE.c.SODDED AREAS MUST BE ACTIVELY GROWING AND MUST REACH A MINIMUM HEIGHT OF 1 1/2 INCHES BEFOREFIRST MOWING. HYDROMULCHED AREAS SHALL SHOW ACTIVE, HEALTHY GROWTH. BARE AREAS LARGER THANTWELVE SQUARE INCHES MUST BE RESODDED OR RESEEDED (AS APPROPRIATE) PRIOR TO FINAL ACCEPTANCE.ALL SODDED TURF SHALL BE NEATLY MOWED.J.WARRANTY PERIOD, PLANT GUARANTEE AND REPLACEMENTS1.THE LANDSCAPE CONTRACTOR SHALL GUARANTEE ALL TREES, SHRUBS, PERENNIALS, SOD, SEEDED/HYDROMULCHEDAREAS, AND IRRIGATION SYSTEMS FOR A PERIOD OF ONE YEAR FROM THE DATE OF THE OWNER'S FINAL ACCEPTANCE(90 DAYS FOR ANNUAL PLANTS). THE CONTRACTOR SHALL REPLACE, AT HIS OWN EXPENSE AND TO THESATISFACTION OF THE OWNER, ANY PLANTS WHICH DIE IN THAT TIME, OR REPAIR ANY PORTIONS OF THE IRRIGATIONSYSTEM WHICH OPERATE IMPROPERLY.2.AFTER THE INITIAL MAINTENANCE PERIOD AND DURING THE GUARANTEE PERIOD, THE LANDSCAPE CONTRACTORSHALL ONLY BE RESPONSIBLE FOR REPLACEMENT OF PLANTS WHEN PLANT DEATH CANNOT BE ATTRIBUTEDDIRECTLY TO OVERWATERING OR OTHER DAMAGE BY HUMAN ACTIONS.K.PROVIDE A MINIMUM OF (2) COPIES OF RECORD DRAWINGS TO THE OWNER UPON COMPLETION OF WORK. A RECORDDRAWING IS A RECORD OF ALL CHANGES THAT OCCURRED IN THE FIELD AND THAT ARE DOCUMENTED THROUGH CHANGEORDERS, ADDENDA, OR CONTRACTOR/CONSULTANT DRAWING MARKUPS.3.PLANTING SPECIFICATIONSPLANTING AT PARKING AREASCALE: NOT TO SCALEEDISTANCE PER PLAN24" MIN. TO EDGEOF MATURE CANOPY23411CURB.2MULCH LAYER.3PLANT.4TURF (WHERE SHOWN ON PLAN).STEEL EDGINGSCALE: NOT TO SCALED1ROLLED-TOP STEEL EDGING PER PLANS.2TAPERED STEEL STAKES.3MULCH, TYPE AND DEPTH PER PLANS.NOTES:1)INSTALL EDGING SO THAT STAKES WILL BE ON INSIDE OF PLANTING BED.2)BOTTOM OF EDGING SHALL BE BURIED A MINIMUM OF 1" BELOW FINISH GRADE.3)TOP OF MULCH SHALL BE 1" LOWER THAN TOP OF EDGING.12344FINISH GRADE.4X2X3215674123SHRUB, PERENNIAL, OR ORNAMENTAL GRASS.MULCH, TYPE AND DEPTH PER PLANS. PLACE NOMORE THAN 1" OF MULCH WITHIN 6" OF PLANTCENTER.FINISH GRADE.BACKFILL. AMEND AND FERTILIZE ONLY ASRECOMMENDED IN SOIL FERTILITY ANALYSIS.ROOT BALL.UNDISTURBED NATIVE SOIL.3" HIGH EARTHEN WATERING BASIN.567SHRUB AND GROUNDCOVER PLANTINGSCALE: NTSB8WEED FABRIC UNDER MULCH.8TREE PLANTINGSCALE: NOT TO SCALEA5674189111012PREVAILINGWINDSNOTES:1.SCARIFY SIDES OF PLANTING PIT PRIOR TO SETTING TREE.2.REMOVE EXCESS SOIL APPLIED ON TOP OF THE ROOTBALL THATCOVERS THE ROOT FLARE. THE PLANTING HOLE DEPTH SHALL BESUCH THAT THE ROOTBALL RESTS ON UNDISTURBED SOIL, AND THEROOT FLARE IS 2"-4" ABOVE FINISH GRADE.3.FOR B&B TREES, CUT OFF BOTTOM 1/3 OF WIRE BASKET BEFOREPLACING TREE IN HOLE, CUT OFF AND REMOVE REMAINDER OFBASKET AFTER TREE IS SET IN HOLE, REMOVE ALL NYLON TIES,TWINE, ROPE, AND OTHER PACKING MATERIAL. REMOVE AS MUCHBURLAP FROM AROUND ROOTBALL AS IS PRACTICAL.4.REMOVE ALL NURSERY STAKES AFTER PLANTING.5.FOR TREES 36" BOX/2.5" CAL. AND LARGER, USE THREE STAKES ORDEADMEN (AS APPROPRIATE), SPACED EVENLY AROUND TREE.6.STAKING SHALL BE TIGHT ENOUGH TO PREVENT TRUNK FROMBENDING, BUT LOOSE ENOUGH TO ALLOW SOME TRUNK MOVEMENTIN WIND.123TREE CANOPY.CINCH-TIES (24" BOX/2" CAL. TREES AND SMALLER) OR12 GAUGE GALVANIZED WIRE WITH NYLON TREESTRAPS AT TREE AND STAKE (36" BOX/2.5" CAL. TREESAND LARGER). SECURE TIES OR STRAPS TO TRUNKJUST ABOVE LOWEST MAJOR BRANCHES.GREEN STEEL T-POSTS. EXTEND POSTS 12" MIN. INTOUNDISTURBED SOIL.24" X 3/4" P.V.C. MARKERS OVER WIRES.PRESSURE-TREATED WOOD DEADMAN, TWO PERTREE (MIN.). BURY OUTSIDE OF PLANTING PIT AND18" MIN. INTO UNDISTURBED SOIL.MULCH, TYPE AND DEPTH PER PLANS. DO NOTPLACE MULCH WITHIN 6" OF TRUNK.FINISH GRADE.BACKFILL. AMEND AND FERTILIZE ONLY ASRECOMMENDED IN SOIL FERTILITY ANALYSIS.ROOT BALL.UNDISTURBED NATIVE SOIL.4" HIGH EARTHEN WATERING BASIN.TRUNK FLARE.CONIFEROUSTREEPREVAILINGWINDSSTAKING EXAMPLES (PLAN VIEW)2467891011143X ROOTBALL DIA.523512NON-CONIFEROUSTREE1313FINISH GRADE.ROOT BARRIER - PLAN VIEWSCALE: NOT TO SCALEFTYPICAL CURB AND GUTTERTYPICAL PLANTING AREALINEAR ROOT BARRIER MATERIAL.SEE PLANTING NOTES FOR TYPEAND MANUFACTURER. INSTALL PERMANUFACTURER'S SPECIFICATIONS.TREE CANOPYTREE TRUNKTYPICAL WALKWAY OR PAVING1234561423565'5'5'5'OPEN LANDSCAPETO 10'PARKWAYOR ISLANDNOTES:1)INSTALL ROOT BARRIERS NEAR ALLNEWLY-PLANTED TREES THAT ARELOCATED WITHIN FIVE (5) FEET OFPAVING OR CURBS.2)BARRIERS SHALL BE LOCATEDIMMEDIATELY ADJACENT TOHARDSCAPE. UNDER NOCIRCUMSTANCES SHALL THECONTRACTOR USE ROOT BARRIERSOF A TYPE THAT COMPLETELYENCIRCLE THE ROOTBALL.PLANT SPACINGSCALE: NTSCPLANT CENTER (TYP.)EQUAL EQUALE Q U A LEDGE OF PLANTING AREAEQUALNOTE: ALL PLANTS SHALL BE PLANTED AT EQUAL TRIANGULAR SPACING (EXCEPT WHERE SHOWN ON PLANS ASINFORMAL GROUPINGS). REFER TO PLANT LEGEND FOR SPACING DISTANCE BETWEEN PLANTS.1) STEP 1: DETERMINE TOTAL PLANTS FOR THE AREA WITH THE FOLLOWING FORMULA:TOTAL AREA / AREA DIVIDER = TOTAL PLANTSPLANT SPACINGAREA DIVIDERPLANT SPACINGAREA DIVIDER6"0.2218"1.958"0.3924"3.4610"0.6030"5.4112"0.8736"7.7915"1.352) STEP 2: SUBTRACT THE ROW (S) OF PLANTS THAT WOULD OCCUR AT THE EDGE OF THE PLANTED AREA WITHTHE FOLLOWING FORMULA: TOTAL PERIMETER LENGTH / PLANT SPACING = TOTAL PLANT SUBTRACTIONEXAMPLE: PLANTS AT 18" O.C. IN 100 SF PLANTING AREA, 40 LF PERIMETERSTEP 1: 100 SF/1.95 = 51 PLANTSSTEP 2: 51 PLANTS - (40 LF / 1.95 = 21 PLANTS) = 30 PLANTS TOTALGENERAL GRADING & PLANTING NOTES1.BY SUBMITTING A PROPOSAL FOR THE LANDSCAPE PLANTING SCOPE OF WORK, THE CONTRACTOR CONFIRMS THAT HE HAS READ, AND WILL COMPLY WITH, THE ASSOCIATED NOTES, SPECIFICATIONS,AND DETAILS WITH THIS PROJECT.2.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL EXISTING VEGETATION (EXCEPT WHERE NOTED TO REMAIN).3.IN THE CONTEXT OF THESE PLANS, NOTES, AND SPECIFICATIONS, "FINISH GRADE" REFERS TO THE FINAL ELEVATION OF THE SOIL SURFACE (NOT TOP OF MULCH) AS INDICATED ON THE GRADING PLANS.a.BEFORE STARTING WORK, THE LANDSCAPE CONTRACTOR SHALL VERIFY THAT THE ROUGH GRADES OF ALL LANDSCAPE AREAS ARE WITHIN +/-0.1' OF FINISH GRADE. SEE SPECIFICATIONS FORMORE DETAILED INSTRUCTION ON TURF AREA AND PLANTING BED PREPARATION.b.CONSTRUCT AND MAINTAIN FINISH GRADES AS SHOWN ON GRADING PLANS, AND CONSTRUCT AND MAINTAIN SLOPES AS RECOMMENDED BY THE GEOTECHNICAL REPORT. ALL LANDSCAPE AREASSHALL HAVE POSITIVE DRAINAGE AWAY FROM STRUCTURES AT THE MINIMUM SLOPE SPECIFIED IN THE REPORT AND ON THE GRADING PLANS, AND AREAS OF POTENTIAL PONDING SHALL BEREGRADED TO BLEND IN WITH THE SURROUNDING GRADES AND ELIMINATE PONDING POTENTIAL.c.THE LANDSCAPE CONTRACTOR SHALL DETERMINE WHETHER OR NOT THE EXPORT OF ANY SOIL WILL BE NEEDED, TAKING INTO ACCOUNT THE ROUGH GRADE PROVIDED, THE AMOUNT OF SOILAMENDMENTS TO BE ADDED (BASED ON A SOIL TEST, PER SPECIFICATIONS), AND THE FINISH GRADES TO BE ESTABLISHED.d.AFTER INSTALLING SOIL AMENDMENTS IN SHRUB AREAS, AND IN ORDER TO ALLOW FOR PROPER MULCH DEPTH, ENSURE THAT THE FINISH GRADE IMMEDIATELY ADJACENT TO WALKS AND OTHERWALKING SURFACES IS 3" BELOW FINISH GRADE, TAPERING TO MEET FINISH GRADE AT APPROXIMATELY 18" AWAY FROM THE SURFACE.e.AFTER INSTALLING SOIL AMENDMENTS IN TURF AREAS, ENSURE THAT THE FINISH GRADE IN TURF AREAS IMMEDIATELY ADJACENT TO WALKS AND OTHER WALKING SURFACES IS 1" BELOW FINISHGRADE, TAPERING TO MEET FINISH GRADE AT APPROXIMATELY 18" AWAY FROM THE SURFACE.f.SHOULD ANY CONFLICTS AND/OR DISCREPANCIES ARISE BETWEEN THE GRADING PLANS, GEOTECHNICAL REPORT, THESE NOTES AND PLANS, AND ACTUAL CONDITIONS, THE CONTRACTOR SHALLIMMEDIATELY BRING SUCH ITEMS TO THE ATTENTION OF THE LANDSCAPE ARCHITECT, GENERAL CONTRACTOR, AND OWNER.4.ALL PLANT LOCATIONS ARE DIAGRAMMATIC. ACTUAL LOCATIONS SHALL BE VERIFIED WITH THE LANDSCAPE ARCHITECT OR DESIGNER PRIOR TO PLANTING. THE LANDSCAPE CONTRACTOR SHALLENSURE THAT ALL REQUIREMENTS OF THE PERMITTING AUTHORITY ARE MET (I.E., MINIMUM PLANT QUANTITIES, PLANTING METHODS, TREE PROTECTION METHODS, ETC.).a.THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR DETERMINING PLANT QUANTITIES; PLANT QUANTITIES SHOWN ON LEGENDS AND CALLOUTS ARE FOR GENERAL INFORMATION ONLY. IN THEEVENT OF A DISCREPANCY BETWEEN THE PLAN AND THE PLANT LEGEND, THE PLANT QUANTITY AS SHOWN ON THE PLAN (FOR INDIVIDUAL SYMBOLS) OR CALLOUT (FOR GROUNDCOVER PATTERNS)SHALL TAKE PRECEDENCE.b.NO SUBSTITUTIONS OF PLANT MATERIALS SHALL BE ALLOWED WITHOUT THE WRITTEN PERMISSION OF THE LANDSCAPE ARCHITECT. IF SOME OF THE PLANTS ARE NOT AVAILABLE, THELANDSCAPE CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT IN WRITING (VIA PROPER CHANNELS).c.THE CONTRACTOR SHALL, AT A MINIMUM, PROVIDE REPRESENTATIVE PHOTOS OF ALL PLANTS PROPOSED FOR THE PROJECT. THE CONTRACTOR SHALL ALLOW THE LANDSCAPE ARCHITECT ANDTHE OWNER/OWNER'S REPRESENTATIVE TO INSPECT, AND APPROVE OR REJECT, ALL PLANTS DELIVERED TO THE JOBSITE. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS FORSUBMITTALS.5.THE CONTRACTOR SHALL MAINTAIN THE LANDSCAPE IN A HEALTHY CONDITION FOR 90 DAYS AFTER ACCEPTANCE BY THE OWNER. REFER TO SPECIFICATIONS FOR CONDITIONS OF ACCEPTANCE FORTHE START OF THE MAINTENANCE PERIOD, AND FOR FINAL ACCEPTANCE AT THE END OF THE MAINTENANCE PERIOD.6.CONTRACTOR SHALL MODIFY EXISTING IRRIGATION SYSTEM TO ACCOMMODATE PROPOSED PLANTINGS & ENSURE FULL FUNCTIONALITY OF SYSTEM.7.SEE SPECIFICATIONS AND DETAILS FOR FURTHER REQUIREMENTS.(dba) MIDWEST DYNAMIC ENGINEERING CONSULTANTS, PC714 S. Greenville AvenueSuite 100Allen, TX 75002T: 972.534.2100Texas Registered Engineering Firm No. F-13660www.dynamicec.comwww.dynamicec.comLAND DEVELOPMENT CONSULTING ● PERMITTINGGEOTECHNICAL ● ENVIRONMENTALTRAFFIC ● SURVEY ● PLANNING & ZONINGOffices conveniently located throughout the United States:New Jersey | Delaware | Florida | Maryland | Pennsylvania | Texas02/12/2025LANDSCAPE ARCHITECTURELAND PLANNING · IRRIGATION DESIGN800.680.6630www.evergreendesigngroup.comNational Presence. Local Expertise.EVERGREEN DESIGN GROUPLANDSCAPE DETAILS &SPECIFICATIONSLP-2.HIAENSSTE HCCTTES A P ETSTAIREG 03OF47ETX LRLDR E CAANDSWEPAESETS 34 43133369980200993201979978989737981988991945(dba) MIDWEST DYNAMIC ENGINEERING CONSULTANTS, PC714 S. Greenville AvenueSuite 100Allen, TX 75002T: 972.534.2100Texas Registered Engineering Firm No. F-13660www.dynamicec.comwww.dynamicec.comLAND DEVELOPMENT CONSULTING ● PERMITTINGGEOTECHNICAL ● ENVIRONMENTALTRAFFIC ● SURVEY ● PLANNING & ZONINGOffices conveniently located throughout the United States:New Jersey | Delaware | Florida | Maryland | Pennsylvania | Texas02/12/2025LANDSCAPE ARCHITECTURELAND PLANNING · IRRIGATION DESIGN800.680.6630www.evergreendesigngroup.comNational Presence. Local Expertise.EVERGREEN DESIGN GROUP020'40'1" = 20'-0"NORTHTREE DISPOSITION PLANNOTE: TREE PROTECTION FOR ANY PRESERVED OR RELOCATEDTREES MUST BE PROVIDED PER DETAILS AND SPECIFICATIONS ONSHEET TD-2. THESE MUST BE UP PRIOR TO THE COMMENCEMENT OFANY WORK AND MAINTAINED THROUGHOUT CONSTRUCTION.NOTE: ALL TREE TRIMMING MUST BE APPROVED BY THE OWNER ANDLOCAL JURISDICTION PRIOR TO COMMENCEMENT OF WORK. ALLTREE TRIMMING MUST BE DONE BY AN ISA CERTIFIED ARBORIST INACCORDANCE WITH LOCAL TREE PRESERVATION ORDINANCE.(A) REMOVED(B) NO PERSON SHALL ATTACH ANY SIGN, NOTICE OR OTHER OBJECT TO ANY PROTECTED TREE OR FASTEN ANY WIRES, CABLES, NAILS ORSCREWS TO ANY PROTECTED TREE IN ANY MANNER THAT COULD PROVE HARMFUL TO THE PROTECTED TREE, EXCEPT AS NECESSARYIN CONJUNCTION WITH ACTIVITIES IN THE PUBLIC INTEREST.(C) DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE CONTRACTOR SHALL NOT CAUSE OR PERMIT THE CLEANING OFEQUIPMENT OR MATERIAL WITHIN THE OUTSIDE PERIMETER OF THE CROWN (DRIPLINE) OR ON THE NEARBY GROUND OF ANY TREE ORGROUP OF TREES WHICH IS TO BE PRESERVED. WITHIN THE OUTSIDE PERIMETER OF THE CROWN (DRIPLINE) OF ANY TREE OR ONNEARBY GROUND, THE CONTRACTOR SHALL NOT CAUSE OR PERMIT STORAGE OF BUILDING MATERIAL AND/OR EQUIPMENT, ORDISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OIL, SOLVENTS, ASPHALT, CONCRETE, MORTAR OR ANY OTHER MATERIAL HARMFULTO THE LIFE OF THE TREE.(D) NO PERSON SHALL PERMIT ANY UNNECESSARY FIRE OR BURNING WITHIN 30 FEET OF THE DRIPLINE OF A PROTECTED TREE.(E)ANY LANDSCAPING ACTIVITIES WITHIN THE BARRIER AREA SHALL BE ACCOMPLISHED WITH HAND LABOR.(F) PRIOR TO ISSUING A CERTIFICATE OF OCCUPANCY OR COMPLIANCE FOR ANY DEVELOPMENT, BUILDING OR STRUCTURE, ALL TREESDESIGNATED TO BE PRESERVED THAT WERE DESTROYED DURING CONSTRUCTION SHALL BE REPLACED BY THE CONTRACTOR WITHTREES OF EQUIVALENT DIAMETER AT BREAST HEIGHT TREE CALIPER AND OF THE SAME SPECIES AS SPECIFIED BY THE CITY STAFF,BEFORE OCCUPANCY OR USE, UNLESS APPROVAL FOR THEIR REMOVAL HAS BEEN GRANTED UNDER PERMIT.(G) THE CITY STAFF MAY CONDUCT PERIODIC INSPECTIONS OF THE SITE DURING LAND CLEARANCE AND CONSTRUCTION.(H) IF, IN THE OPINION OF THE CITY STAFF, DEVELOPMENT ACTIVITIES WILL SO SEVERELY STRESS SLASH PINES OR ANY OTHERPROTECTED TREE SUCH THAT THEY ARE MADE SUSCEPTIBLE TO INSECT ATTACK, PREVENTATIVE SPRAYING OF THESE TREES BY THECONTRACTOR MAY BE REQUIRED.TREE PROTECTION GENERAL NOTESLEGENDTHE DEVELOPER SHALL ERECT AN ORANGE PLASTIC MESH FENCE, OR OTHER APPROVED FENCING MATERIAL, A MINIMUM OFFOUR FEET IN HEIGHT AROUND EACH TREE OR GROUP OF TREES TO PREVENT THE PLACEMENT OF DEBRIS, EQUIPMENT, ORFILL WITHIN THE DRIPLINE OR CRITICAL ROOT ZONE. THE FENCE SHALL BE INSTALLED PRIOR TO THE RELEASE OF ANY PERMIT.IF THE PROTECTION FENCE IS FOUND REMOVED, DAMAGED, OR ALTERED AT ANY TIME DURING CONSTRUCTION PRIOR TOFINAL INSPECTION OR LANDSCAPE INSTALLATION, A STOP WORK ORDER MAY BE ISSUED BY THE BUILDING OFFICIAL.TREE INVENTORYSITE VICINITY MAP, NTSEXISTING TREES OR PALMSTO BE PRESERVED &PROTECTED IN PLACEEXISTING TREE OR PALM TOBE REMOVEDTREE PROTECTIONFENCEEXISTING TREES OR PALMSOUTSIDE OF PROPERTY LINETREE #TREE #TD-1SITETREE NO.SPECIESBOTANICAL NAMEDBH (INCHES)DISPOSITIONREASON200OAKQUERCUS SPP.12TO BE REMOVEDCONSTRUCTION201OAKQUERCUS SPP.14TO BE REMOVEDCONSTRUCTION737OAKQUERCUS SPP.12TO REMAIN*OFFSITE,CONSTRUCTION945OAKQUERCUS SPP.18TO REMAIN*OFFSITE978DT COTTONWOODPOPULUS SPP.8UNPROTECTED,TO BE REMOVED CONSTRUCTION979MT WILLOWSALIX SPP.8TO BE REMOVEDCONSTRUCTION980OAKQUERCUS SPP.14TO BE REMOVEDCONSTRUCTION981OAKQUERCUS SPP.10TO BE REMOVED*OFFSITE,CONSTRUCTION988OAKQUERCUS SPP.8TO BE REMOVED*OFFSITE,CONSTRUCTION989OAKQUERCUS SPP.10TO BE REMOVED*OFFSITE,CONSTRUCTION991OAKQUERCUS SPP.14TO REMAIN*OFFSITE993OAKQUERCUS SPP.18TO BE REMOVEDCONSTRUCTION3369LOCUSTGLEDITSIA SPP.10TO BE REMOVEDCONSTRUCTION4313OAKQUERCUS SPP.14TO REMAINTREE MITIGATIONMITIGATION RATIODBH (INCHES)REMOVEDDBH (INCHES)REQUIREDREPLACEMENT1" REMOVED = 1"REPLACED104104.HIAENSSTE HCCTTES A P ETSTAIREG 03OF47ETX LRLDR E CAANDSWEPAESETS TREE MITIGATION:162" TOTAL INCHES104" TO BE REMOVED58" TO REMAIN1. 58" / 162" = 35.8% TREE PRESERVATION CREDIT1.a. 35.8% x 104" = 37.2" TO BE MITIGATED.2. LANDSCAPE CREDIT CAN BE GIVEN TO SATISFY UP TO 50% OF THE 37.2" (16.6").2. a. LANDSCAPE PLAN SHOWS MORE THAN 16.6".3. THE REMAINING 16.6" TO BE PAID IN LIEU OF TREE REPLACEMENT TO THE CITY OFCOPPELL REFORESTATION AND NATURAL AREAS FUND AT $100.00 PER ONE INCHDBH FOR TREES LESS THAN 12 INCHES DBH AND $200 PER ONE INCH DBH FOR TREESOVER 12 INCHES DBH.3.a. (16.6" x $100.00 = $1,660.00 TOTAL FEE)35 (dba) MIDWEST DYNAMIC ENGINEERING CONSULTANTS, PC714 S. Greenville AvenueSuite 100Allen, TX 75002T: 972.534.2100Texas Registered Engineering Firm No. F-13660www.dynamicec.comwww.dynamicec.comLAND DEVELOPMENT CONSULTING ● PERMITTINGGEOTECHNICAL ● ENVIRONMENTALTRAFFIC ● SURVEY ● PLANNING & ZONINGOffices conveniently located throughout the United States:New Jersey | Delaware | Florida | Maryland | Pennsylvania | Texas02/12/2025LANDSCAPE ARCHITECTURELAND PLANNING · IRRIGATION DESIGN800.680.6630www.evergreendesigngroup.comNational Presence. Local Expertise.EVERGREEN DESIGN GROUPTREE PROTECTIONSPECIFICATIONS & DETAILSTUNNEL TO MINIMIZE ROOT DAMAGE (TOP) AS OPPOSED TO SURFACE-DUGTRENCHES IN ROOT PROTECTION ZONE WHEN THE 5' MINIMUM DISTANCEFROM TRUNK CAN NOT BE ACHIEVED.TREES THAT ARE MARKED TO BE PRESERVED ON A SITE PLAN AND FOR WHICHUTILITIES MUST PASS TROUGH THEIR ROOT PROTECTION ZONES MAY REQUIRETUNNELING AS OPPOSED TO OPEN TRENCHES. THE DECISION TO TUNNEL WILL BEDETERMINED ON A CASE BY CASE BASIS BY THE ENGINEER.TUNNELS SHALL BE DUG THROUGH THE ROOT PROTECTION ZONE IN ORDER TOMINIMIZE ROOT DAMAGE.(RPZ)ROOT PROTECTION ZONEIF BARE DIRT8" MULCH OUTSIDE RPZ ESTABLISH FENCE PROTECTIONMINIMUM 5' FROM TRUNK6" MULCH INSIDE RPZDRIP LINEOPEN TRENCHING MAY BE USED IF EXPOSED TREE ROOTS DO NOTEXCEED 3" OR ROOTS CAN BE BENT BACK.ROOT PROTECTION ZONE (RPZ)PROPERTY LINETREE TRUNKS T R E E T 5'CURBNOTES:1.THE FENCING LOCATION SHOWN ABOVE IS DIAGRAMATIC ONLY AND WILLCONFORM TO THE DRIP LINE AND BE LIMITED TO PROJECT BOUNDARY. WHEREMULTIPLE ADJACENT TREES WILL BE ENCLOSED BY FENCING, THE FENCING SHALLBE CONTINUOUS AROUND ALL TREES.2.FOR ACCEPTABLE FENCING MATERIALS SEE SPECIFICATIONS.AND UNDER DRIP LINE AS MINIMALPROTECTION FOR ROOTS FROMCONSTRUCTION ACTIVITIESNOTES:1.OPTION USED FOR TIGHT CONSTRUCTIONAREAS OR WHEN CONSTRUCTIONOCCURS IN ROOT PROTECTION ZONE.2.FOR ACCEPTABLE FENCING MATERIALSSEE SPECIFICATIONS.12" MIN & 48" MAX DEPTH TREE PROTECTION FENCESCALE: NOT TO SCALEABSCALE: NOT TO SCALETREE PROTECTION FENCE - TIGHT CONSTRUCTIONBORING THROUGH ROOT PROTECTION ZONESCALE: NOT TO SCALECROOT PROTECTION ZONE (RPZ)MULCH INSIDE RPZPROTECTION FENCE(SEE SPECS)MATERIALS1.FABRIC: 4 FOOT HIGH ORANGE PLASTIC FENCING AS SHOWNON THE PLANS AND SHALL BE WOVEN WITH 2 INCH MESHOPENINGS SUCH THAT IN A VERTICAL DIMENSION OF 23INCHES ALONG THE DIAGONALS OF THE OPENINGS THERESHALL BE AT LEAST 7 MESHES.2.POSTS: POSTS SHALL BE A MINIMUM OF 72 INCHES LONG ANDSTEEL 'T' SHAPED WITH A MINIMUM WEIGHT OF 1.3 POUNDSPER LINEAR FOOT.3.TIE WIRE: WIRE FOR ATTACHING THE FABRIC TO THET-POSTS SHALL BE NOT LESS THAN NO. 12 GAUGEGALVANIZED WIRE,4.USED MATERIALS: PREVIOUSLY-USED MATERIALS, MEETINGTHE ABOVE REQUIREMENTS AND WHEN APPROVED BY THEOWNER, MAY BE USED.CONSTRUCTION METHODS1.ALL TREES AND SHRUBS SHOWN TO REMAIN WITHIN THEPROXIMITY OF THE CONSTRUCTION SITE SHALL BEPROTECTED PRIOR TO BEGINNING ANY DEVELOPMENTACTIVITY.2.EMPLOY THE SERVICES OF AN ISA (INTERNATIONAL SOCIETYOF ARBORICULTURE) CERTIFIED ARBORIST AND OBTAIN ALLREQUIRED PERMITS TO PRUNE THE EXISTING TREES FORCLEANING, RAISING AND THINNING, AS MAY BE REQUIRED.3.PROTECTIVE FENCING SHALL BE ERECTED OUTSIDE THECRITICAL ROOT ZONE (CRZ, EQUAL TO 1' FROM THE TRUNKFOR EVERY 1" OF DBH) AT LOCATIONS SHOWN IN THE PLANSOR AS DIRECTED BY THE LANDSCAPE CONSULTANT AND/ORCITY ARBORIST, AND IN ACCORDANCE WITH THE DETAILSSHOWN ON THE PLANS. FENCING SHALL BE MAINTAINED ANDREPAIRED BY THE CONTRACTOR DURING SITECONSTRUCTION. TREES IN CLOSE PROXIMITY SHALL BEFENCED TOGETHER, RATHER THAN INDIVIDUALLY.4.PROTECTIVE FENCE LOCATIONS IN CLOSE PROXIMITY TOSTREET INTERSECTIONS OR DRIVES SHALL ADHERE TO THEAPPLICABLE JURISDICTION'S SIGHT DISTANCE CRITERIA.5.THE PROTECTIVE FENCING SHALL BE ERECTED BEFORE SITEWORK COMMENCES AND SHALL REMAIN IN PLACE DURINGTHE ENTIRE CONSTRUCTION PHASE.6.THE INSTALLATION POSTS SHALL BE PLACED EVERY 6 FEETON CENTER AND EMBEDDED TO 18 INCHES DEEP. MESHFABRIC SHALL BE ATTACHED TO THE INSTALLATION POSTS BYTHE USE OF SUFFICIENT WIRE TIES TO SECURELY FASTENTHE FABRIC TO THE T-POSTS TO HOLD THE FABRIC IN ASTABLE AND UPRIGHT POSITION.7.WITHIN THE CRZ:a.DO NOT CLEAR, FILL OR GRADE IN THE CRZ OF ANY TREE.b.DO NOT STORE, STOCKPILE OR DUMP ANY JOB MATERIAL,SOIL OR RUBBISH UNDER THE SPREAD OF THE TREEBRANCHES.c.DO NOT PARK OR STORE ANY EQUIPMENT OR SUPPLIESUNDER THE TREE CANOPY.d.DO NOT SET UP ANY CONSTRUCTION OPERATIONSUNDER THE TREE CANOPY (SUCH AS PIPE CUTTING ANDTHREADING, MORTAR MIXING, PAINTING OR LUMBERCUTTING).e.DO NOT NAIL OR ATTACH TEMPORARY SIGNS METERS,SWITCHES, WIRES, BRACING OR ANY OTHER ITEM TO THETREES.f.DO NOT PERMIT RUNOFF FROM WASTE MATERIALSINCLUDING SOLVENTS, CONCRETE WASHOUTS, ASPHALTTACK COATS (MC-30 OIL), ETC. TO ENTER THE CRZ.BARRIERS ARE TO BE PROVIDED TO PREVENT SUCHRUNOFF SUBSTANCES FROM ENTERING THE CRZWHENEVER POSSIBLE, INCLUDING IN AN AREA WHERERAIN OR SURFACE WATER COULD CARRY SUCHMATERIALS TO THE ROOT SYSTEM OF THE TREE.8.ROUTE UNDERGROUND UTILITIES TO AVOID THE CRZ. IFDIGGING IS UNAVOIDABLE, BORE UNDER THE ROOTS, ORHAND DIG TO AVOID SEVERING THEM.9.WHERE EXCAVATION IN THE VICINITY OF TREES MUST OCCUR,SUCH AS FOR IRRIGATION INSTALLATION, PROCEED WITHCAUTION, AND USING HAND TOOLS ONLY.10.THE CONTRACTOR SHALL NOT CUT ROOTS LARGER THANONE INCH IN DIAMETER WHEN EXCAVATION OCCURS NEAREXISTING TREES. ALL ROOTS LARGER THAN ONE INCH INDIAMETER ARE TO BE CUT CLEANLY. FOR OAKS ONLY, ALLWOUNDS SHALL BE PAINTED WITH WOUND SEALER WITHIN 30MINUTES11.REMOVE ALL TREES, SHRUBS OR BUSHES TO BE CLEAREDFROM PROTECTED ROOT ZONE AREAS BY HAND.12.TREES DAMAGED OR KILLED DUE TO CONTRACTOR'SNEGLIGENCE DURING CONSTRUCTION SHALL BE MITIGATEDAT THE CONTRACTOR'S EXPENSE AND TO THE PROJECTOWNER'S AND LOCAL JURISDICTION'S SATISFACTION.13.ANY TREE REMOVAL SHALL BE APPROVED BY THE OWNERAND LOCAL JURISDICTION PRIOR TO ITS REMOVAL, AND THECONTRACTOR SHALL HAVE ALL REQUIRED PERMITS FORSUCH ACTIVITIES.14.COVER EXPOSED ROOTS AT THE END OF EACH DAY WITHSOIL, MULCH OR WET BURLAP.15.IN CRITICAL ROOT ZONE AREAS THAT CANNOT BEPROTECTED DUING CONSTRUCTION AND WHERE HEAVYTRAFFIC IS ANTICIPATED, COVER THE SOIL WITH EIGHTINCHES OF ORGANIC MULCH TO MINIMIZE SOIL COMPACTION.THIS EIGHT INCH DEPTH OF MULCH SHALL BE MAINTAINEDTHROUGHOUT CONSTRUCTION.16.WATER ALL TREES IMPACTED BY CONSTRUCTION ACTIVITIES,DEEPLY ONCE A WEEK DURING PERIODS OF HOT DRYWEATHER. SPRAY TREE CROWNS WITH WATERPERIODICALLY TO REDUCE DUST ACCUMULATION ON THELEAVES.17.WHEN INSTALLING CONCRETE ADJACENT TO THE ROOT ZONEOF A TREE, USE A PLASTIC VAPOR BARRIER BEHIND THECONCRETE TO PROHIBIT LEACHING OF LIME INTO THE SOIL.18.CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL TREEPROTECTION FENCING WHEN ALL THREATS TO THE EXISTINGTREES FROM CONSTRUCTION-RELATED ACTIVITIES HAVEBEEN REMOVED.DSCALE: NOT TO SCALEROOT PRUNING DETAILEXISTING GRADENOTES1.RETENTION AREAS WILL BE SET AS PART OF THE REVIEW PROCESS AND PRE-CONSTRUCTIONMEETING.2.BOUNDARIES OF RETENTION AREAS MUST BE STAKED AT THE PRE-CONSTRUCTION MEETINGAND FLAGGED PRIOR TO ROOT PRUNING.3.EXACT LOCATION OF ROOT PRUNING SHALL BE DETERMINED IN THE FIELD IN COORDINATIONWITH THE FORESTRY INSPECTOR .4.TRENCH SHOULD BE IMMEDIATELY BACKFILLED WITH EXCAVATED SOIL OR OTHER ORGANIC SOILAS SPECIFIED PER PLAN OR BY THE FORESTRY INSPECTOR.5.ROOTS SHALL BE CLEANLY CUT USING VIBRATORY KNIFE OR OTHER ACCEPTABLE EQUIPMENT.ROT PRUNING METHODS AND MEANS MUST BE IN ACCORDANCE WITH ANSI STANDARD A3000.6.ALL PRUNING MUST BE EXECUTED AT LOD SHOWN ON PLANS OR AS AUTHORIZED IN WRITING BYTHE FORESTRY INSPECTOR.7.SUPPLEMENTAL WATERING MAY BE REQUIRED FOR ROOT PRUNED TREES THROUGHOUT THEGROWING SEASON DURING CONSTRUCTION AND SUBSEQUENT WARRANTY AND MAINTENANCEPERIOD.ROOT PRUNE VIA AIRSPACE ORTRENCH (6" WIDE MAX.) 24" MIN.DEPTH OR AS DETERMINED ATPRE-CONSTRUCTION MEETING.TREE PROTECTION FENCE TOBE ERECTED IN LINE WITHROOT PRUNING LIMITS. SEEDETAILS AND SPECIFICATIONSFOR TREE PROTECTIONFENCE REQUIREMENTS.TREE RELOCATION GUIDELINES1.TREES SHALL NOT BE UNNECESSARILY DAMAGED DURING REMOVAL, TRANSPORT OR REPLANTING OF THE TREE.2.IF THE TREE HAS A DORMANT PERIOD, THEY SHOULD BE TRANSPLANTED DURING THAT TIME. TREES SHOULD NOT BE TRANSPLANTED DURING PERIODS OFSTRONG WINDS, DRY WINTER WINDS OR DURING DROUGHT.3.ADEQUATE SPACES FOR ROOT AND CROWN DEVELOPMENT SHALL BE PROVIDED.4.TREES SHALL BE ROOT AND CANOPY PRUNED IN ACCORDANCE WITH SOUND ARBORICULTURAL STANDARDS PRIOR TO TRANSPLANTING.5.DURING AND FOLLOWING TRANSPLANTING, THE ROOT BALL AND TRUNK SHALL BE PROTECTED. THE ROOT BALL MUST BE KEPT MOIST AT ALL TIMES.6.TRANSPLANTED TREES SHALL BE BRACED FOR A MINIMUM OF ONE (1) YEAR.7.TRANSPLANTED TREES SHALL NOT BE FERTILIZED AT PLANTING TIME, BUT SHALL BE WATERED SUFFICIENTLY UNTIL THE TREE GROWTH IS REESTABLISHED.8.ALL CROWN PRUNING SHALL BE DONE IN ACCORDANCE WITH "THE AMERICAN NATIONAL STANDARDS INSTITUTE A-300, TREE SHRUB AND OTHER WOODY PLANTMAINTENANCE-STANDARD PRACTICES", AND "Z-133.1 PRUNING, REPAIRING, MAINTAINING AND REMOVING TREES, AND CUTTING BRUSH-SAFETY REQUIREMENTS"OR PALM PRUNING IN ACCORDANCE WITH THE STANDARDS IN, RICHARD HARRIS, "ARBORICULTURE INTEGRATED MANAGEMENT OF LANDSCAPE TREES, SHRUBSAND VINES", AS AMENDED.9.CONTRACTOR IS RESPONSIBLE FOR REGULAR WATERING AND MAINTENANCE OF TRANSPLANTED TREES DURING STORAGE PERIOD.(A) PRIOR TO THE LAND CLEARING STAGE OF DEVELOPMENT, THE CONTRACTOR SHALL CLEARLY MARK ALL PROTECTED TREES FOR WHICH A TREE REMOVAL PERMITHAS NOT BEEN ISSUED AND SHALL ERECT BARRIERS FOR THE PROTECTION OF THE TREES ACCORDING TO THE FOLLOWING:(1)  AROUND AN AREA AT OR GREATER THAN A SIX-FOOT RADIUS OF ALL SPECIES OF MANGROVES AND PROTECTED CABBAGE PALMS;(2)  AROUND AN AREA AT OR GREATER THAN THE FULL DRIPLINE OF ALL PROTECTED NATIVE PINES;(3)  AROUND AN AREA AT OR GREATER THAN TWO-THIRDS OF THE DRIPLINE OF ALL OTHER PROTECTED SPECIES.(B) NO PERSON SHALL ATTACH ANY SIGN, NOTICE OR OTHER OBJECT TO ANY PROTECTED TREE OR FASTEN ANY WIRES, CABLES, NAILS OR SCREWS TO ANYPROTECTED TREE IN ANY MANNER THAT COULD PROVE HARMFUL TO THE PROTECTED TREE, EXCEPT AS NECESSARY IN CONJUNCTION WITH ACTIVITIES IN THEPUBLIC INTEREST.(C) DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE CONTRACTOR SHALL NOT CAUSE OR PERMIT THE CLEANING OF EQUIPMENT OR MATERIAL WITHINTHE OUTSIDE PERIMETER OF THE CROWN (DRIPLINE) OR ON THE NEARBY GROUND OF ANY TREE OR GROUP OF TREES WHICH IS TO BE PRESERVED. WITHIN THEOUTSIDE PERIMETER OF THE CROWN (DRIPLINE) OF ANY TREE OR ON NEARBY GROUND, THE CONTRACTOR SHALL NOT CAUSE OR PERMIT STORAGE OF BUILDINGMATERIAL AND/OR EQUIPMENT, OR DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OIL, SOLVENTS, ASPHALT, CONCRETE, MORTAR OR ANY OTHER MATERIALHARMFUL TO THE LIFE OF THE TREE.(D) NO PERSON SHALL PERMIT ANY UNNECESSARY FIRE OR BURNING WITHIN 30 FEET OF THE DRIPLINE OF A PROTECTED TREE.(E)ANY LANDSCAPING ACTIVITIES WITHIN THE BARRIER AREA SHALL BE ACCOMPLISHED WITH HAND LABOR.(F) PRIOR TO ISSUING A CERTIFICATE OF OCCUPANCY OR COMPLIANCE FOR ANY DEVELOPMENT, BUILDING OR STRUCTURE, ALL TREES DESIGNATED TO BEPRESERVED THAT WERE DESTROYED DURING CONSTRUCTION SHALL BE REPLACED BY THE CONTRACTOR WITH TREES OF EQUIVALENT DIAMETER AT BREASTHEIGHT TREE CALIPER AND OF THE SAME SPECIES AS SPECIFIED BY THE COUNTY ADMINISTRATOR, BEFORE OCCUPANCY OR USE, UNLESS APPROVAL FOR THEIRREMOVAL HAS BEEN GRANTED UNDER PERMIT.(G) THE COUNTY ADMINISTRATOR MAY CONDUCT PERIODIC INSPECTIONS OF THE SITE DURING LAND CLEARANCE AND CONSTRUCTION.(H) IF, IN THE OPINION OF THE COUNTY ADMINISTRATOR, DEVELOPMENT ACTIVITIES WILL SO SEVERELY STRESS SLASH PINES OR ANY OTHER PROTECTED TREESUCH THAT THEY ARE MADE SUSCEPTIBLE TO INSECT ATTACK, PREVENTATIVE SPRAYING OF THESE TREES BY THE CONTRACTOR MAY BE REQUIRED.TREE PROTECTION GENERAL NOTESTREE PROTECTION SPECIFICATIONSTD-2.HIAENSSTE HCCTTES A P ETSTAIREG 03OF47ETX LRLDR E CAANDSWEPAESETS 36 FIRST FLOOR PLAN -0' - 0" RCP10' - 0" T.O. ROOF23' - 0" STUCCO STONE-1 SSMT-1 PRE-ENGINEERED AWNING CAP STONE 118' - 0"FIRST FLOOR PLAN - 0' - 0" RCP10' - 0" T.O. ROOF23' - 0" STUCCO STONE-1 CAP STONE SSMT-1 1 18' - 0"THIS DOCUMENT IS NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION. SHEET TITLE: PROJECT NO: DRAWN BY: CHECKED BY: NO:DESCRIPTION:DATE: ISSUED BY: CONSULTANTS: 1201 EVANS AVE. SUITE 300 FORT WORTH, TX 76104 PHONE: 817 653-3007 matthijs@melarch.com DATE: REVISIONS COPYRIGHT: MELCHIORS ARCHITECTURE, LLC. 2025 EXTERIOR ELEVATIONS A300 Project Status 360 State Hwy 121, Coppell, TX 75019 PC24024 JM 02/11/2025 MM MM COPPELL ENTERTAINMENT PLAZA, LOT 1, BLOCK A GENERAL NOTESNOTES BY NUMBER 1. 2. 3. 4. 5. 6. REFER TO CIVIL, STRUCTURAL, MECHANICAL, AND ELECTRICAL SHEETS FOR ADDITIONAL CONSTRUCTION INFORMATION. CONTRACTOR TO COORDINATE ALL WORK WITH OTHER TRADES INVOLVED IN ORDER TO MINIMIZE CONFLICT AND TO COORDINATE ALL ACTIVITIES. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING UTILITIES, GENERAL SITE CONDITIONS, SPOT ELEVATIONS, AND DIMENSIONS PRIOR TO CONSTRUCTION - NOTIFIY ARCHITECT OF ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS IMMEDIATELY. IT SHALL BE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO FAMILIARIZE HIMSELF/HERSELF WITH EXISTING SITE CONTITIONS AND ALL APPLICABLE FEDERAL, STATE, LOCA LAWS AND REGULATIONS. IF THERE IS A CONFLICT BETWEEN THESE DOCUMENTS AND ALL APPLICABLE LAWS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING PRIOR TO THE COMMENCEMENT OF WORK.. THE CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, AND MATERIALS UNLESS INDICATED OTHERWISE, AS WELL AS SECURE ALL NECESSARY PERMITS TO PERFORM THE WORK INDICATED WITHIN THESE DOCUMENTS. THESE CONSTRUCTION DRAWINGS DO NOT CONTAIN INFORMATION WITH REGARD TO CONSTRUCTION SAFETY PROCEDURES. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION SAFETY AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE CONSTRUCTION SAFETY GUIDELINES. 7.PROVIDE CONTROL JOINTS AT ALL COLOR AND FINISH MATERIAL TRANSITIONS AT SPACING PER MANUFACTURER RECOMMENDATIONS. EXTERIOR FINISH SCHEDULE AWNING SSMT-1 MARK DESCRIPTION MANUFACTURER SERIES COLOR REMARKS STANDING SEAM METAL ROOF MATL DESCRIPTION TO BE DETERMINED -- 1HM DOOR & FRAME. 2 3 4 5 6 7 8 9 TO BE DETERMINED TO BE DETERMINED -- -- -- GRAY -- -- GRAY 1/8" = 1'-0"A300 1SOUTH ELEVATION 1/8" = 1'-0"A300 2NORTH ELEVATION STONE-1 STUCCO-1 STUCCO WALL CULTURED STONE EL DORADO STONE CAP STONE-1 LIMESTONE CAP TO BE DETERMINED --DARK GRAY 37 FIRST FLOOR PLAN -0' - 0" RCP 10' - 0" T.O. ROOF23' - 0" STUCCO STONE-1 CAP STONE SSMT-1 PRE-ENGINEERED AWNING 1 18' - 0"FIRST FLOOR PLAN -0' - 0" RCP 10' - 0" T.O. ROOF 23' - 0" STONE-1 PRE-ENGINEERED AWNING SSMT-1 CAP STONE STUCCO 18' - 0"THIS DOCUMENT IS NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION. SHEET TITLE: PROJECT NO: DRAWN BY: CHECKED BY: NO:DESCRIPTION:DATE: ISSUED BY: CONSULTANTS: 1201 EVANS AVE. SUITE 300 FORT WORTH, TX 76104 PHONE: 817 653-3007 matthijs@melarch.com DATE: REVISIONS COPYRIGHT: MELCHIORS ARCHITECTURE, LLC. 2025 EXTERIOR ELEVATIONS A301 Project Status 360 State Hwy 121, Coppell, TX 75019 PC24024 JM 02/11/2025 MM MM COPPELL ENTERTAINMENT PLAZA, LOT 1, BLOCK A GENERAL NOTESNOTES BY NUMBER 1. 2. 3. 4. 5. 6. REFER TO CIVIL, STRUCTURAL, MECHANICAL, AND ELECTRICAL SHEETS FOR ADDITIONAL CONSTRUCTION INFORMATION. CONTRACTOR TO COORDINATE ALL WORK WITH OTHER TRADES INVOLVED IN ORDER TO MINIMIZE CONFLICT AND TO COORDINATE ALL ACTIVITIES. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING UTILITIES, GENERAL SITE CONDITIONS, SPOT ELEVATIONS, AND DIMENSIONS PRIOR TO CONSTRUCTION - NOTIFIY ARCHITECT OF ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS IMMEDIATELY. IT SHALL BE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO FAMILIARIZE HIMSELF/HERSELF WITH EXISTING SITE CONTITIONS AND ALL APPLICABLE FEDERAL, STATE, LOCA LAWS AND REGULATIONS. IF THERE IS A CONFLICT BETWEEN THESE DOCUMENTS AND ALL APPLICABLE LAWS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING PRIOR TO THE COMMENCEMENT OF WORK.. THE CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, AND MATERIALS UNLESS INDICATED OTHERWISE, AS WELL AS SECURE ALL NECESSARY PERMITS TO PERFORM THE WORK INDICATED WITHIN THESE DOCUMENTS. THESE CONSTRUCTION DRAWINGS DO NOT CONTAIN INFORMATION WITH REGARD TO CONSTRUCTION SAFETY PROCEDURES. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION SAFETY AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE CONSTRUCTION SAFETY GUIDELINES. 7.PROVIDE CONTROL JOINTS AT ALL COLOR AND FINISH MATERIAL TRANSITIONS AT SPACING PER MANUFACTURER RECOMMENDATIONS. EXTERIOR FINISH SCHEDULE STONE-1 STUCCO-1 MARK DESCRIPTION MANUFACTURER SERIES COLOR REMARKS STUCCO WALL CULTURED STONE TO BE DETERMINED -- 1HM DOOR & FRAME. 2 3 4 5 6 7 8 9 EL DORADO STONE TO BE DETERMINED TO BE DETERMINED -- -- -- -- -- 1/8" = 1'-0"A301 1EAST ELEVATION 1/8" = 1'-0"A301 2WEST ELEVATION AWNING SSMT-1 STANDING SEAM METAL ROOF MATL DESCRIPTION GRAY GRAY CAP STONE-1 LIMESTONE CAP TO BE DETERMINED --DARK GRAY 38 EX.ELECTRICTRANSFORMEREX. 48" RCPEX. 21" STMEX. 21" STMEX. 18" STMEX. 33" STMEX. 18" STMEX. 24" STMEX. 24" STMEX. 24" STMEX. 24" STMEX. 18" STMEX. 18" STMEX. 33" STM468468469469471471472473474471472473474476471472473474476477468469471472473474476476477478468469471469471472473474467467470470470475475475470475475470470EX. INLETEX. INLETRIM: 572.28FL: 464.65EX. INLETRIM: 471.30FL: 465.54EX. 3'X3'JUNCTIONBOXRIM: 472.35FL: 466.24EX. 48" RCPFL: 470.39EX. GRATE INLETEX. 3'X3' JUNCTIONBOXRIM: 469.85FL 24" (N): 464.36±FL 18" (E): 464.36±FL 24" (S): 464.28±EX. 5' CURB INLETAPPROXIMATE LOCATIONOF EX. SSMHRIM: 470.71FL 27": 454.54±EX. GRATE INLET20' LANDSCAPE EASEMENTEX. ELECTRIC LINEEX. 12" SSEX. 8" SSEX. 8"WATER LINEEX. 27" SSEX. CONCRETE FENCE FOOTEREX. WALLEX. LIGHT (TYP.)EX.FIREHYDRANT(TYP.)EX. FENCEEX. MAILBOXEXIST.IRRIGATIONVALVESEX. GRATE INLET (TYP.)EX. 18' RCPEX. IRON FENCEEX. WOODEN FENCEEX. ELECTRIC MHEX. WALLEX. TRANSFORMEREXIST.IRRIGATIONVALVESEX. FIRE HYDRANT (TYP.)EX. SS MHEX. INLETEX. GRATE INLETEX. FIREHYDRANT(TYP.)98873798997920199320043139459919819803369978EMDENTON COUNTYDALLAS COUNTY5/8" IRF EX. 20' SANITARYSEWER EASEMENTCAB. P, SLD. 160,O.P.R.D.C.T.LOT 1, BLOCK ANORTH GATEWAY PLAZAINS. NO. 201800044533,O.P.R.Da.C.T. 250 W STATE HWY 121LOT 2R, BLOCK 1COPPELL/121 OFFICE PARKINS. NO. 200600246548,O.P.R.Da.C.T.CAB. X, SLIDE 169,O.P.R.De.C.T.370 W STATE HWY 121 LOT 18, BLOCK CCOPPELL GREENSPHASE ONECAB. P, SLIDE 160,O.P.R.D.C.T.LOT 17,BLOCK C LOT 16,BLOCK C LOT 15,BLOCK CLOT 19,BLOCK CLOT 33, BLOCK CCOPPELL GREENSPHASE ONECAB. P, SLIDE 160,O.P.R.De.C.T.217 TURNBERRY LNLOT 30,BLOCK CLOT 32,BLOCK CLOT 31,BLOCK CLOT 34,BLOCK CLOT 18X,BLOCK CLOT 35,BLOCK CCALLED: 1.615 ACRESDENTON 121 COPPELLSHOPPING CENTRE, LLCINS. NO. 201900233593,O.P.R.Da.C.T.INS. NO. 2019-107570,O.P.R.De.C.T.360 W STATE HWY 121LOT 18X,BLOCK CLOT 58X, BLOCK CCOPPELL GREENSPHASE TWOCAB. R, SLIDE 104,O.P.R.De.C.T.1.6159 ACRES(70,388 SQ. FT.)1/2" IRF5/8" IRF1/2" IRF 5/8" CIRF BHB INC.TBM #2BM X CUTEL=471.15'N=7046895.022E=2429865.070EL=470.94202471.08CP X-CUTTBM #1BM X CUTN=7047212.899E=2429692.597EL=478.33205471.24CP X-CUT206472.52CP X-CUT201474.35CP X-CUT207472.32CP X-CUT203471.29CP X-CUT204471.48CP X-CUT5/8" CIRFSURVCONINC.5/8" CIRFBHB INC.5/8" CIRFBHB INC.10' LANDSCAPE EASEMENT20' REAR YARD SETBACK60' FRONTYARD SETBACK30' SIDEYARDSETBACK30' SIDE YARD SETBACK165.0'106.7'PROP. 1 STORYBUILDING17,655 SFPROP.DETENTIONPONDEX. 24' ACCESS & FIRELANE EASEMENTINS. NO. 200402888858,O.P.R.Da.C.T.EX. 20' UTILITY EASEMENTINS. NO. 200402888858,O.P.R.Da.C.T.EX. 20' DRAINAGE EASEMENTINS. NO. 200402888858,O.P.R.D.C.T.EX. 7.5' UTILITY EASEMENTCAB. P, SLD. 160,O.P.R.D.C.T.EX. 20' DRAINAGE EASEMENTCAB. P, SLD. 160,O.P.R.D.C.T.EX. DRAINAGE &UTIL. EASEMENTCAB. R, SLD. 104,O.P.R.De.C.T.EX. 20' EASEMENTTEXAS UTILITIES ELECTRICCO. & COSERV, LLCVOL. 99036, PG. 1401,O.P.R.Da.C.T.EX. 20' EASEMENTTEXAS UTILITIES ELECTRICCO. & COSERV, LLCVOL. 99036, PG. 1401,O.P.R.Da.C.T.EX. 10' SIDEWALK EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 24' FIRE LANE &MUTUAL ACCESS EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 10' DRAINAGEEASEMENTCAB. V, SLD. 727,O.P.R.De.C.T.EX. 10' DRAINAGEEASEMENTCITY OF COPPELL,TEXASINS. NO. 200402885527,O.P.R.D.C.T.EX. 10' EASEMENTCOSERV ELECTRICINS. NO. 2004-138839,O.P.R.De.C.T.EX. 5' UTILITY EASEMENTCAB. P, SLD. 160,O.P.R.De.C.T.EX. 7.5' UTILITY EASEMENTCAB. P, SLD. 160,O.P.R.De.C.T.EX. 7.5' UTILITY EASEMENTCAB. R, SLD. 104,O.P.R.De.C.T.EX. 24' FIRE LANE &MUTUAL ACCESS EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 10' SIDEWALK EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 15' PRIVATEDRAINAGE EASEMENTD.C.C.I. NO. 201800044533, O.P.R.Da.C.T.EX. 20' SANITARYSEWER EASEMENTCITY OF COPPELLVOL. 98146, PG. 4736,O.P.R.Da.C.T.VOL. 4155, PG. 21,O.P.R.Dn.C.T.EX. 20' UTILITY EASEMENTVOL. 2004093, PG. 28,O.P.R.Da.C.T.(50' WIDE PUBLIC R.O.W.,CAB. P, SLD. 160, O.P.R.D.C.T.)(50' WIDE PUBLIC R.O.W.,CAB. P, SLD. 160, O.P.R.D.C.T.)TURNBERRY LANEKILBRIDGE LANE(VARIABLE WIDE PUBLIC R.O.W.)STATE HIGHWAY 121S23° 26'05"W328.60'N89° 59'54"E164.48'S66° 29'20"E107.54'N23° 25'32"E249.98'N66° 36'18"W125.15'N60° 48'33"W133.94' 10' LANDSCAPE EASEMENTDDDDDDSSS SDDYHDYHDYHDSTDYHDYHDYHSSEX.ELECTRICTRANSFORMEREX. 48" RCPEX. 21" STMEX. 21" STMEX. 18" STMEX. 33" STMEX. 18" STMEX. 24" STMEX. 24" STMEX. 24" STMEX. 24" STMEX. 18" STMEX. 18" STMEX. 33" STM468468469469471471472473474471472473474476471472473474476477468469471472473474476476477478468469471469471472473474467467470470470475475475470475475470470EX. INLETEX. INLETRIM: 572.28FL: 464.65EX. INLETRIM: 471.30FL: 465.54EX. 3'X3'JUNCTIONBOXRIM: 472.35FL: 466.24EX. 48" RCPFL: 470.39EX. GRATE INLETEX. 3'X3' JUNCTIONBOXRIM: 469.85FL 24" (N): 464.36±FL 18" (E): 464.36±FL 24" (S): 464.28±EX. 5' CURB INLETAPPROXIMATE LOCATIONOF EX. SSMHRIM: 470.71FL 27": 454.54±EX. GRATE INLET20' LANDSCAPE EASEMENTEX. ELECTRIC LINEEX. 12" SSEX. 8" SSEX. 8"WATER LINEEX. 27" SSEX. CONCRETE FENCE FOOTEREX. WALLEX. LIGHT (TYP.)EX.FIREHYDRANT(TYP.)EX. FENCEEX. MAILBOXEXIST.IRRIGATIONVALVESEX. GRATE INLET (TYP.)EX. 18' RCPEX. IRON FENCEEX. WOODEN FENCEEX. ELECTRIC MHEX. WALLEX. TRANSFORMEREXIST.IRRIGATIONVALVESEX. FIRE HYDRANT (TYP.)EX. SS MHEX. INLETEX. GRATE INLETEX. FIREHYDRANT(TYP.)98873798997920199320043139459919819803369978EMDENTON COUNTYDALLAS COUNTY5/8" IRFEX. 20' SANITARYSEWER EASEMENTCAB. P, SLD. 160,O.P.R.D.C.T.LOT 1, BLOCK ANORTH GATEWAY PLAZAINS. NO. 201800044533,O.P.R.Da.C.T. 250 W STATE HWY 121LOT 2R, BLOCK 1COPPELL/121 OFFICE PARKINS. NO. 200600246548,O.P.R.Da.C.T.CAB. X, SLIDE 169,O.P.R.De.C.T.370 W STATE HWY 121LOT 18, BLOCK CCOPPELL GREENSPHASE ONECAB. P, SLIDE 160,O.P.R.D.C.T.LOT 17,BLOCK CLOT 16,BLOCK CLOT 15,BLOCK CLOT 19,BLOCK CLOT 33, BLOCK CCOPPELL GREENSPHASE ONECAB. P, SLIDE 160,O.P.R.De.C.T.217 TURNBERRY LNLOT 30,BLOCK CLOT 32,BLOCK CLOT 31,BLOCK CLOT 34,BLOCK CLOT 18X,BLOCK CLOT 35,BLOCK CCALLED: 1.615 ACRESDENTON 121 COPPELLSHOPPING CENTRE, LLCINS. NO. 201900233593,O.P.R.Da.C.T.INS. NO. 2019-107570,O.P.R.De.C.T.360 W STATE HWY 121LOT 18X,BLOCK CLOT 58X, BLOCK CCOPPELL GREENSPHASE TWOCAB. R, SLIDE 104,O.P.R.De.C.T.1.6159 ACRES(70,388 SQ. FT.)1/2" IRF5/8" IRF1/2" IRF5/8" CIRF BHB INC.TBM #2BM X CUTEL=471.15'N=7046895.022E=2429865.070EL=470.94202471.08CP X-CUTTBM #1BM X CUTN=7047212.899E=2429692.597EL=478.33205471.24CP X-CUT206472.52CP X-CUT201474.35CP X-CUT207472.32CP X-CUT203471.29CP X-CUT204471.48CP X-CUT5/8" CIRFSURVCONINC.5/8" CIRFBHB INC.5/8" CIRFBHB INC.10' LANDSCAPE EASEMENT20' REAR YARD SETBACK60' FRONTYARD SETBACK30' SIDEYARDSETBACK30' SIDE YARD SETBACK165.0'106.7'PROP. 1 STORYBUILDING17,655 SFPROP.DETENTIONPONDEX. 24' ACCESS & FIRELANE EASEMENTINS. NO. 200402888858,O.P.R.Da.C.T.EX. 20' UTILITY EASEMENTINS. NO. 200402888858,O.P.R.Da.C.T.EX. 20' DRAINAGE EASEMENTINS. NO. 200402888858,O.P.R.D.C.T.EX. 7.5' UTILITY EASEMENTCAB. P, SLD. 160,O.P.R.D.C.T.EX. 20' DRAINAGE EASEMENTCAB. P, SLD. 160,O.P.R.D.C.T.EX. DRAINAGE &UTIL. EASEMENTCAB. R, SLD. 104,O.P.R.De.C.T.EX. 20' EASEMENTTEXAS UTILITIES ELECTRICCO. & COSERV, LLCVOL. 99036, PG. 1401,O.P.R.Da.C.T.EX. 20' EASEMENTTEXAS UTILITIES ELECTRICCO. & COSERV, LLCVOL. 99036, PG. 1401,O.P.R.Da.C.T.EX. 10' SIDEWALK EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 24' FIRE LANE &MUTUAL ACCESS EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 10' DRAINAGEEASEMENTCAB. V, SLD. 727,O.P.R.De.C.T.EX. 10' DRAINAGEEASEMENTCITY OF COPPELL,TEXASINS. NO. 200402885527,O.P.R.D.C.T.EX. 10' EASEMENTCOSERV ELECTRICINS. NO. 2004-138839,O.P.R.De.C.T.EX. 5' UTILITY EASEMENTCAB. P, SLD. 160,O.P.R.De.C.T.EX. 7.5' UTILITY EASEMENTCAB. P, SLD. 160,O.P.R.De.C.T.EX. 7.5' UTILITY EASEMENTCAB. R, SLD. 104,O.P.R.De.C.T.EX. 24' FIRE LANE &MUTUAL ACCESS EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 10' SIDEWALK EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 15' PRIVATEDRAINAGE EASEMENTD.C.C.I. NO. 201800044533, O.P.R.Da.C.T.EX. 20' SANITARYSEWER EASEMENTCITY OF COPPELLVOL. 98146, PG. 4736,O.P.R.Da.C.T.VOL. 4155, PG. 21,O.P.R.Dn.C.T.EX. 20' UTILITY EASEMENTVOL. 2004093, PG. 28,O.P.R.Da.C.T.(50' WIDE PUBLIC R.O.W.,CAB. P, SLD. 160, O.P.R.D.C.T.)(50' WIDE PUBLIC R.O.W.,CAB. P, SLD. 160, O.P.R.D.C.T.)TURNBERRY LANEKILBRIDGE LANE(VARIABLE WIDE PUBLIC R.O.W.)STATE HIGHWAY 121S23° 26'05"W328.60'N89° 59'54"E164.48'S66° 29'20"E107.54'N23° 25'32"E249.98'N66° 36'18"W125.15'N60° 48'33"W133.94' 10' LANDSCAPE EASEMENTDDDDDDSSSSDDYHDYHDYHDSTDYHDYHDYHSS 20' - 0"10' - 0"10' - 0"DUMPSTER SOLID METAL GATES. REF ELEVS 4" EXTRA STRONG PIPE POST FILLED W/ CONCRETE. BOTH SIDES OF GATE CMU BLOCK WALLS. REFER TO ELEVS & SECTION A8002 A8003 A800 4 A800 5 1% SLOPE2' - 0"2' - 0"2' - 0"2' - 0"6" CONCRETE PIPE BOLLARD. PAINTED SAFETY YELLOW. TYPICAL OF 2.6" CONCRETE PIPE BOLLARD. PAINTED SAFETY YELLOW. TYPICAL OF 2. SLOPED CONC. REINFORCED TRASH ENCLOSURE PAD, REF: CIVIL 2' - 0"4' - 0"6' - 8"4' - 0"2' - 0"1' - 6"1' - 6"7' - 4"CMU BLOCK WALL WITH STUCCO FINISH3' - 2"GALV. MTL CAP W/ SLOPED WD BLOCKING. CONFIRM FINISH. CMU BLOCK WALL WITH STUCCO FINISH (CMU-1)6' - 0"T.O. MASONRYSINGLE METAL GATE. GALV. MTL CAP W/ SLOPED WD BLOCKING. CONFIRM FINISH. CMU BLOCK WALL WITH STUCCO FINISH (CMU-1)6' - 0"T.O. MASONRYGALV. MTL CAP W/ SLOPED WD BLOCKING. CONFIRM FINISH. CMU BLOCK WALL WITH STUCCO FINISH (CMU-1)6' - 0"T.O. MASONRYGALV. MTL CAP W/ SLOPED WD BLOCKING. CONFIRM FINISH. DUMPSTER SOLID METAL GATES.6' - 0"T.O. MASONRY8" BOND BEAM w/ 2) #5 CONT. 8" CMU w/#5 @24" O.C. (CENTER IN WALL) PROVIDE DOWEL w/STD. HK TO MATCH VERT. REINF. SIZE & SPACING GROUT SOLID BELOW GRADE PAVEMENT PER CIV. 1/2" EXPANSION JOINT 6" SLAB ON GRADE w/#3 @ 16" O.C. (CENTERED IN SLAB) SEE ARCH. FOR SIZE & LOCATION 95% MAX DRY DENSITY @ +4% ABOVE OPTIMUM MOISTURE CONTENT #5 @ 8" O.C.E.W. SEE ARCH. FOR INFO NOT SHOWN 3000 psi 3'-0".1'-0".1'-8".8'-0" MAXTHIS DOCUMENT IS NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION. SHEET TITLE: PROJECT NO: DRAWN BY: CHECKED BY: NO:DESCRIPTION:DATE: ISSUED BY: CONSULTANTS: 1201 EVANS AVE. SUITE 300 FORT WORTH, TX 76104 PHONE: 817 653-3007 matthijs@melarch.com DATE: REVISIONS COPYRIGHT: MELCHIORS ARCHITECTURE, LLC. 2025 TRASH ENCLOSURE & DETAILS A800 Project Status 360 State Hwy 121, Coppell, TX 75019 PC24024 JM 02/11/2025 MM MM COPPELL ENTERTAINMENT PLAZA, LOT 1, BLOCK A 1/2" = 1'-0"A800 1ENLARGED TRASH ENCLOSURE PLAN 1/2" = 1'-0"A800 2 EAST ELEVATION - DUMPSTER 1/2" = 1'-0"A800 3 WEST ELEVATION - DUMPSTER 1/2" = 1'-0"A800 4NORTH ELEVATION - DUMPSTER 1/2" = 1'-0"A800 5 SOUTH ELEVATION - DUMPSTER 3/4" = 1'-0"A800 6 TRASH WALL SECTION DETAIL 39 EX.ELECTRICTRANSFORMEREX. 48" RCPEX. 21" STMEX. 21" STMEX. 18" STMEX. 33" STMEX. 18" STMEX. 24" STMEX. 24" STMEX. 24" STMEX. 24" STMEX. 18" STMEX. 18" STMEX. 33" STM468468469469471471472473474471472473474476471472473474476477468469471472473474476476477478468469471469471472473474467467470470470475475475470475475470470EX. INLETEX. INLETRIM: 572.28FL: 464.65EX. INLETRIM: 471.30FL: 465.54EX. 3'X3'JUNCTIONBOXRIM: 472.35FL: 466.24EX. 48" RCPFL: 470.39EX. GRATE INLETEX. 3'X3' JUNCTIONBOXRIM: 469.85FL 24" (N): 464.36±FL 18" (E): 464.36±FL 24" (S): 464.28±EX. 5' CURB INLETAPPROXIMATE LOCATIONOF EX. SSMHRIM: 470.71FL 27": 454.54±EX. GRATE INLET20' LANDSCAPE EASEMENTEX. ELECTRIC LINEEX. 12" SSEX. 8" SSEX. 8"WATER LINEEX. 27" SSEX. CONCRETE FENCE FOOTEREX. WALLEX. LIGHT (TYP.)EX.FIREHYDRANT(TYP.)EX. FENCEEX. MAILBOXEXIST.IRRIGATIONVALVESEX. GRATE INLET (TYP.)EX. 18' RCPEX. IRON FENCEEX. WOODEN FENCEEX. ELECTRIC MHEX. WALLEX. TRANSFORMEREXIST.IRRIGATIONVALVESEX. FIRE HYDRANT (TYP.)EX. SS MHEX. INLETEX. GRATE INLETEX. FIREHYDRANT(TYP.)98873798997920199320043139459919819803369978EMDENTON COUNTYDALLAS COUNTY5/8" IRFEX. 20' SANITARYSEWER EASEMENTCAB. P, SLD. 160,O.P.R.D.C.T.LOT 1, BLOCK ANORTH GATEWAY PLAZAINS. NO. 201800044533,O.P.R.Da.C.T. 250 W STATE HWY 121LOT 2R, BLOCK 1COPPELL/121 OFFICE PARKINS. NO. 200600246548,O.P.R.Da.C.T.CAB. X, SLIDE 169,O.P.R.De.C.T.370 W STATE HWY 121LOT 18, BLOCK CCOPPELL GREENSPHASE ONECAB. P, SLIDE 160,O.P.R.D.C.T.LOT 17,BLOCK CLOT 16,BLOCK CLOT 15,BLOCK CLOT 19,BLOCK CLOT 33, BLOCK CCOPPELL GREENSPHASE ONECAB. P, SLIDE 160,O.P.R.De.C.T.217 TURNBERRY LNLOT 30,BLOCK CLOT 32,BLOCK CLOT 31,BLOCK CLOT 34,BLOCK CLOT 18X,BLOCK CLOT 35,BLOCK CCALLED: 1.615 ACRESDENTON 121 COPPELLSHOPPING CENTRE, LLCINS. NO. 201900233593,O.P.R.Da.C.T.INS. NO. 2019-107570,O.P.R.De.C.T.360 W STATE HWY 121LOT 18X,BLOCK CLOT 58X, BLOCK CCOPPELL GREENSPHASE TWOCAB. R, SLIDE 104,O.P.R.De.C.T.1.6159 ACRES(70,388 SQ. FT.)1/2" IRF5/8" IRF1/2" IRF5/8" CIRF BHB INC.TBM #2BM X CUTEL=471.15'N=7046895.022E=2429865.070EL=470.94202471.08CP X-CUTTBM #1BM X CUTN=7047212.899E=2429692.597EL=478.33205471.24CP X-CUT206472.52CP X-CUT201474.35CP X-CUT207472.32CP X-CUT203471.29CP X-CUT204471.48CP X-CUT5/8" CIRFSURVCONINC.5/8" CIRFBHB INC.5/8" CIRFBHB INC.10' LANDSCAPE EASEMENT20' REAR YARD SETBACK60' FRONTYARD SETBACK30' SIDEYARDSETBACK30' SIDE YARD SETBACK165.0'106.7'PROP. 1 STORYBUILDING17,655 SFPROP.DETENTIONPONDEX. 24' ACCESS & FIRELANE EASEMENTINS. NO. 200402888858,O.P.R.Da.C.T.EX. 20' UTILITY EASEMENTINS. NO. 200402888858,O.P.R.Da.C.T.EX. 20' DRAINAGE EASEMENTINS. NO. 200402888858,O.P.R.D.C.T.EX. 7.5' UTILITY EASEMENTCAB. P, SLD. 160,O.P.R.D.C.T.EX. 20' DRAINAGE EASEMENTCAB. P, SLD. 160,O.P.R.D.C.T.EX. DRAINAGE &UTIL. EASEMENTCAB. R, SLD. 104,O.P.R.De.C.T.EX. 20' EASEMENTTEXAS UTILITIES ELECTRICCO. & COSERV, LLCVOL. 99036, PG. 1401,O.P.R.Da.C.T.EX. 20' EASEMENTTEXAS UTILITIES ELECTRICCO. & COSERV, LLCVOL. 99036, PG. 1401,O.P.R.Da.C.T.EX. 10' SIDEWALK EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 24' FIRE LANE &MUTUAL ACCESS EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 10' DRAINAGEEASEMENTCAB. V, SLD. 727,O.P.R.De.C.T.EX. 10' DRAINAGEEASEMENTCITY OF COPPELL,TEXASINS. NO. 200402885527,O.P.R.D.C.T.EX. 10' EASEMENTCOSERV ELECTRICINS. NO. 2004-138839,O.P.R.De.C.T.EX. 5' UTILITY EASEMENTCAB. P, SLD. 160,O.P.R.De.C.T.EX. 7.5' UTILITY EASEMENTCAB. P, SLD. 160,O.P.R.De.C.T.EX. 7.5' UTILITY EASEMENTCAB. R, SLD. 104,O.P.R.De.C.T.EX. 24' FIRE LANE &MUTUAL ACCESS EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 10' SIDEWALK EASEMENTD.C.C.I. NO. 201800044533,O.P.R.Da.C.T.EX. 15' PRIVATEDRAINAGE EASEMENTD.C.C.I. NO. 201800044533, O.P.R.Da.C.T.EX. 20' SANITARYSEWER EASEMENTCITY OF COPPELLVOL. 98146, PG. 4736,O.P.R.Da.C.T.VOL. 4155, PG. 21,O.P.R.Dn.C.T.EX. 20' UTILITY EASEMENTVOL. 2004093, PG. 28,O.P.R.Da.C.T.(50' WIDE PUBLIC R.O.W.,CAB. P, SLD. 160, O.P.R.D.C.T.)(50' WIDE PUBLIC R.O.W.,CAB. P, SLD. 160, O.P.R.D.C.T.)TURNBERRY LANEKILBRIDGE LANE(VARIABLE WIDE PUBLIC R.O.W.)STATE HIGHWAY 121S23° 26'05"W328.60'N89° 59'54"E164.48'S66° 29'20"E107.54'N23° 25'32"E249.98'N66° 36'18"W125.15'N60° 48'33"W133.94' 10' LANDSCAPE EASEMENTDDDDDDSSSSDDYHDYHDYHDSTDYHDYHDYHSS SEE ARCH. FOR INFO NOT SHOWN TYPE- S MORTAR GROUT CAPSTONE 3000 psi PAVEMENT PER CIV. 6" SLAB ON GRADE w/#3 @ 16" O.C. (CENTERED IN SLAB) SEE ARCH. FOR SIZE & LOCATION 1/2" EXPANSION JOINT #5 @ 6" O.C.E.W. 95% MAX DRY DENSITY @ +4% ABOVE OPTIMUM MOISTURE CONTENT 5" MIN. THICKNESS PCC STEM WALL FOOTING @ 12 FT O.C. 3' - 0"1' - 8"2' - 6"8'-0" MAX10' - 0"10' - 0"10' - 0"10' - 0"10' - 0" MODULAR BRICK WALL 6' - 0"7' - 0"THIS DOCUMENT IS NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION. SHEET TITLE: PROJECT NO: DRAWN BY: CHECKED BY: NO:DESCRIPTION:DATE: ISSUED BY: CONSULTANTS: 1201 EVANS AVE. SUITE 300 FORT WORTH, TX 76104 PHONE: 817 653-3007 matthijs@melarch.com DATE: REVISIONS COPYRIGHT: MELCHIORS ARCHITECTURE, LLC. 2025 SCREENING WALL DETAIL A801 Project Status 360 State Hwy 121, Coppell, TX 75019 PC24024 JM 02/11/2025 MM MM COPPELL ENTERTAINMENT PLAZA, LOT 1, BLOCK A 1" = 1'-0"A801 2SCREENING WALL SECTION DETAIL 1/4" = 1'-0"A801 1SCREENING WALL ELEVATION 40 THIS DOCUMENT IS NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION. SHEET TITLE: PROJECT NO: DRAWN BY: CHECKED BY: NO:DESCRIPTION:DATE: ISSUED BY: CONSULTANTS: 1201 EVANS AVE. SUITE 300 FORT WORTH, TX 76104 PHONE: 817 653-3007 matthijs@melarch.com DATE: REVISIONS COPYRIGHT: MELCHIORS ARCHITECTURE, LLC. 2025 PERSPECTIVE A802 Project Status 360 State Hwy 121, Coppell, TX 75019 PC24024 JM 02/13/2025 MM MM COPPELL ENTERTAINMENT PLAZA, LOT 1, BLOCK A STUCCO-1STONE-1 BRICK-1LIMESTONE-1 STONE-1 SSMT-1 CAP STONE-1STUCCO-1 BRICK-1 41 ST S S 10' ELE C T RI C LI N E EASEM E N T 10' DRAINAGE EASEMENT 10' DRAINAGE EASEMENT TBM #1 "X" CUT S E T 478.33' TRANS F O R M E R P A D 10' LANDSCAPE EASEMENT 10' LANDS C A P E EASEM E N T 165' - 0"106' - 8 3/4"10' - 0 "4' - 0"4' - 0"4' - 0"4' - 0"4' - 0" 13' - 0"1' - 0"9' - 0 3/4"35' - 0 1/4"PROP. DETENTION POND 1960 SF FUTURE RETAIL 100 11833 SF PICKLEBALL FACILITY 200 40 SF MOP SINK 300 56 SF RESTROOM 202 56 SF RESTROOM 201 SPECTATOR BENCH (3)SPECTATOR BENCH (3)SPECTATOR BENCH (3)SPECTATOR BENCH (3)SPECTATOR BENCH (3)1 2 345 9' - 0 3/4"2' - 0"7' - 0"202 SF EQUIPMENT ROOM 204 56 SF FIRE RISER ROOM 205DYH99 7 2 10 157' - 0"133' - 0" LEAVE OUT 7' - 0"PICKLEBALL RACKPICKLEBALL RACKPICKLEBALL RACK PICKLEBALL RACK PICKLEBALL RACK A800 1 DYH10' - 0"10' - 0" 6' TALL B RI C K S C R E E NI N G W A L L EGRESS 133' - 0" FIRE LANE EASEMENT FIRE LANE EASEMENT 2461 SF FUTURE RESTAURANT 20828' - 5 5/8"28' - 0" 8' - 0"15' - 3 1/8"1' - 4"3' - 4"3' - 4" 3' - 0"24' - 2 1/4"36' - 4 3/4"30' - 0"39' - 5"8' - 4 3/4"5' - 0"24' - 0" 5' - 0"25' - 0"THIS DOCUMENT IS NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION. SHEET TITLE: PROJECT NO: DRAWN BY: CHECKED BY: NO:DESCRIPTION:DATE: ISSUED BY: CONSULTANTS: 1201 EVANS AVE. SUITE 300 FORT WORTH, TX 76104 PHONE: 817 653-3007 matthijs@melarch.com DATE: REVISIONS COPYRIGHT: MELCHIORS ARCHITECTURE, LLC. 2025 FIRST LEVEL FLOOR PLAN A201 Project Status 360 State Hwy 121, Coppell, TX 75019 PC24024 JM 02/11/2025 MM MM COPPELL ENTERTAINMENT PLAZA, LOT 1, BLOCK A GENERAL NOTES NOTES BY NUMBER 1 FIRE SPRINKLER RISER ROOM MINIMUM OF 56 S.F. (8'X7') DIMENSIONS. 2 3 4 5 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. REFER TO CIVIL, STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS FOR ADDITIONAL CONSTRUCTION INFORMATION. CONTRACTOR TO COORDINATE ALL WORK WITH OTHER TRADES. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING UTILITIES, GENERAL SITE CONDITIONS, SPOT ELEVATIONS AND DIMENSIONS PRIOR TO CONSTRUCTION-NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS IMMEDIATELY. IT SHALL BE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO FAMILIARIZE HIMSELF/HERSELF WITH EXISTING SITE CONTITIONS AND ALL APPLICABLE FEDERAL, STATE, LOCA LAWS AND REGULATIONS. IF THERE IS A CONFLICT BETWEEN THESE DOCUMENTS AND ALL APPLICABLE LAWS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING PRIOR TO THE CONSTRUCTION PHASE. THE CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, AND MATERIALS UNLESS INDICATED OTHERWISE, AS WELL AS SECURE ALL NECESSARY PERMITS TO PERFORM THE WORK INDICATED WITHIN THESE DOCUMENTS. INTERIOR DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD UNLESS NOTED OTHER WISE. BUILDING CODE REQUIRES THAT INTERIOR PARTITION WALLS TO BE DESIGNED AFOR A LATERAL LOAD OF 5 PSF. MAXIMUM HORIZONTAL DEFLECTION IS ASSUMED TO BE LIMITED TO H/240. PROVIDE LATERAL BRACING PER SCHEDULE. BRACE STUDS ABOVE CEILINGTO CREATE RIGID WALLS THROUGHOUT. COMPLY WITH LATERAL BRACING SCHEDULE ON THIS SHEET. REFER TO STRUCTURAL DRAWINGS FOR LOCATIONS OF ALL SHEER WALLS CONSTRUCTION NOTES AND DETAILS. CONCEALED SPACES IN WALLS AND BULKHEADS NOT COMPLETELY FILLED WITH NON- COMBUSTIBLE INSULATION, TO BE FIRESTOPPED AT THE LEVEL OF ALL ADJACENT CEILINGS AND AT ROOF DECK TO PREVENT SPREAD OF FIRE INOT OR OUT OF WALL CAVITY AND/OR PLENUM SPACE. CONTRACTOR TO COORDINATE QUANTITY AND LOCATION OF FIRE EXTINGUISHERS WITH LOCAL FIRE MARSHALL. PROVIDE BLOCKING FOR FIRE EXTINGUISHER PRIOR TO CLOSING OFF WALLS. USED RECESSED CABINETS IN PUBLIC/OFFICE AREAS. SURFACE MOUNTED IN MAINTENANCE AREAS. TOP OF CABINET AT 44 1/2" A.F.F. PROVIDE BLOCKING IN WALLS AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT SHOWN THROUGHOUT PLANS: TOILET ACCESSORIES, BUILDING SIGNAGE, PHONE BOARD, AND WALL SHELVING. 1/16" = 1'-0"A201 1FLOOR PLAN LEGEND 42 0.1 0.2 0.2 0.3 0.6 1.0 0.1 0.2 0.3 0.8 1.5 3.1 0.5 0.1 0.2 0.4 0.9 1.7 3.1 0.9 0.6 0.4 0.2 0.1 0.1 0.2 0.4 0.8 1.5 1.7 1.3 1.2 0.9 0.5 0.3 0.2 0.1 0.2 0.2 0.4 0.7 1.3 1.1 2.2 2.7 1.6 0.9 0.5 0.3 0.2 0.2 0.1 0.2 0.3 0.4 0.6 1.0 1.5 4.8 7.3 2.0 1.0 0.6 0.4 0.3 0.2 0.3 0.3 0.1 0.1 0.2 0.3 0.4 0.6 1.0 1.8 3.5 0.3 0.2 0.2 0.4 0.4 0.4 0.4 0.4 0.1 0.1 0.2 0.3 0.5 0.7 1.2 2.0 2.8 0.2 0.4 0.6 0.9 0.9 0.7 0.5 0.6 0.1 0.1 0.1 0.5 0.5 0.6 0.9 1.6 2.4 1.7 0.6 1.5 1.5 1.1 0.8 0.9 1.5 2.2 0.2 0.2 0.9 0.9 0.8 0.9 1.3 1.9 2.7 1.6 2.4 1.2 1.1 2.0 3.4 0.3 0.1 0.4 0.2 2.5 1.3 0.9 1.1 1.6 2.2 1.9 8.1 4.5 1.1 1.1 1.7 0.2 0.2 0.3 3.4 2.4 1.3 1.0 1.3 1.8 2.4 2.3 1.8 0.7 0.6 0.7 0.1 0.1 0.1 0.2 2.5 1.8 1.1 1.1 1.4 1.7 1.5 0.4 0.8 0.7 0.4 0.3 0.1 0.1 0.1 0.7 1.3 1.1 1.0 1.2 1.7 2.1 0.9 0.8 0.5 0.3 0.2 0.1 0.1 0.1 0.5 0.7 0.8 0.9 1.3 1.8 2.4 1.5 1.0 0.6 0.4 0.2 0.1 0.1 0.1 0.2 0.3 0.5 0.7 1.0 1.5 1.7 1.3 2.2 1.8 1.2 0.9 0.6 0.1 0.1 0.1 0.2 0.3 0.4 0.7 1.2 1.9 2.2 4.6 2.3 1.4 1.5 1.3 0.1 0.1 0.1 0.2 0.3 0.5 0.8 1.4 2.1 2.4 3.0 4.9 2.2 1.8 2.3 1.0 0.1 0.1 0.2 0.4 0.6 1.0 1.6 2.1 1.9 2.2 1.7 2.2 2.8 0.3 0.1 0.2 0.3 0.6 0.8 1.2 1.9 2.7 2.3 2.0 1.5 1.3 1.8 2.9 0.3 0.1 0.2 0.4 0.8 1.2 1.6 2.1 1.5 1.5 1.1 0.9 1.2 0.2 0.1 0.1 0.1 0.1 0.2 1.3 1.7 1.9 2.3 3.6 3.0 1.2 1.0 0.7 0.5 0.4 0.1 0.1 0.1 0.1 0.2 0.3 2.9 2.1 2.0 2.7 4.9 5.7 6.8 1.3 1.3 1.1 0.8 0.5 0.3 0.1 0.1 0.1 0.1 0.1 0.3 0.5 0.5 2.5 1.5 1.8 2.3 2.7 1.3 0.7 0.6 1.8 1.2 0.7 0.4 0.2 0.1 0.1 0.1 0.1 0.1 0.4 0.3 0.2 0.7 0.7 0.8 0.9 0.9 1.1 1.3 1.4 1.4 2.0 2.5 1.8 1.1 0.8 0.5 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 1.8 2.1 2.3 2.0 2.1 2.3 1.6 1.0 0.9 1.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.5 3.3 2.3 1.7 1.6 1.3 1.1 1.1 2.4 0.2 0.1 0.1 0.1 0.1 0.1 0.3 0.5 0.4 0.4 1.1 1.0 1.0 1.0 1.3 2.6 0.3 0.2 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.6 0.8 1.2 2.4 0.3 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.6 0.9 1.1 0.1 0.1 0.1 0.2 0.3 0.4 0.6 0.4 0.2 0.2 0.3 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 8.3 Plan View Scale - 1" = 20ft Statistics Description Symbol Avg Max Min Max/Min Avg/Min Calc Zone #2 0.9 fc 8.3 fc 0.0 fc N/A N/A Schedule Symbol Label Image QTY Manufacturer Catalog Description Number Lamps Lamp Output LLF Input Power Polar Plot A 13 Lithonia Lighting DSXW1 P2 40K 80CRI T3M 3000 4000K 80CRI Type 3 Medium 1 2058 1 14.58 B 5 Lithonia Lighting WDGE1 LED P2 40K 80CRI VW WDGE1 LED WITH P2 - PERFORMANCE PACKAGE, 4000K, 80CRI, VISUAL COMFORT WIDE OPTIC 1 1982 1 15.0178 C 7 Lithonia Lighting DSX0 LED P3 35K 80CRI BLC3 EGS-F D-Series Size 0 Area Luminaire P3 Performance Package 3500K CCT 80 CRI Type 3 Extreme Backlight Control Forward External Glare Shield 1 3458 1 68.95 Coppell Pickleball Court360 SH 121Coppell, TexasDesigner Wesley St.John Date 02/10/2025 Scale Not to Scale Drawing No. 1 Summary Photometric Site Plan 1 of 1 43 ITEM 11 Page 1 of 2 CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT Coppell Entertainment Plaza, Lot 1, Block A, Minor Plat P&Z HEARING DATE: February 20, 2025 CITY COUNCIL HEARING DATE: March 11, 2025 STAFF REP.: Matthew Steer, AICP, Development Services Administrator LOCATION: North side of State Highway 121, approximately 940 feet west of N Denton Tap Road SIZE OF AREA: 1.6 acres of property CURRENT ZONING: Highway Commercial (HC) REQUEST: Consider approval of Coppell Entertainment Plaza, Lot 1, Block A, Minor Plat, a minor plat to create a building site for an indoor pickleball/retail/restaurant facility and associated easements. APPLICANT: Owner Owner’s Representative/Engineer Jinting Chen Lindey Mayer, P.E. Coppell PKB LLC Dynamic Engineering Consultants, PC 3120 Golden Springs Drive 714 S Greenville Avenue, Suite 100 Plano, Texas 75025 Allen, Texas 75002 972-302-7625 972-534-2100 JasonC@IndoorPickleballNow.com LMayer@DynamicEC.com HISTORY: This property has never been platted. The zoning was changed from Light Industrial to Highway Commercial District in 2004. HISTORIC COMMENT: This property has no historic significance. TRANSPORTATION: State Highway 121 and frontage road. SURROUNDING LAND USE & ZONING: North: Residential, Coppell Greens; Planned Development-134R-Single Family-7 South: Residential, Magnolia Park; Planned Development-133R-Single Family-9 East: LA Fitness; Planned Development-240R3-Highway Commercial West: Medical Office; Highway Commercial 45 ITEM 11 Page 2 of 2 COMPREHENSIVE PLAN: Coppell 2030, A Comprehensive Master Plan, shows this land as appropriate for Freeway Special District use. DISCUSSION: This is the companion request to the Planned Development to allow for construction of an indoor pickleball/retail/restaurant facility. The plat addresses the easements and fire lanes required to serve the building. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff is recommending APPROVAL of the plat, subject to the following conditions: 1. TxDOT will be required to approve the tie-in to their stormwater system. 2. There will be additional comments at the time of Detail Engineering Review and Building Permit. 3. The tree mitigation fees are paid at time of tree removal permit. 4. The 6’ screening wall will be required to be constructed prior to the buildings going vertical. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: 1. Recommend approval of the request 2. Recommend disapproval of the request 3. Recommend modification of the request 4. Take under advisement for reconsideration at a later date ATTACHMENTS: 1. Minor Plat 46 LOT 1, BLOCK A NORTH GATEWAY PLAZA INS. NO. 201800044533, O.P.R.Da.C.T. LOT 2R, BLOCK 1 COPPELL/121 OFFICE PARK INS. NO. 200600246548, O.P.R.Da.C.T. CAB. X, SLIDE 169, O.P.R.De.C.T.EX. 24' ACCESS & FIRELANE EASEMENTINS. NO. 200402888858,O.P.R.Da.C.T.1/2" IRF 5/8" IRF 1/2" IRF LOT 33, BLOCK C COPPELL GREENS PHASE ONE CAB. P, SLIDE 160, O.P.R.De.C.T. 217 TURNBERRY LN LOT 32, BLOCK C LOT 31, BLOCK C LOT 34, BLOCK C LOT 18X, BLOCK C LOT 35, BLOCK C CAB. P, SLD. 160, O.P.R.D.C.T.)LOT 1, BLOCK A COPPELL ENTERTAINMENT PLAZA 1.615 ACRES CALLED: 1.546 ACRES COPPELL PKB, LLC. INS. NO. 202400249061, O.P.R.Da.C.T. LOT 18X, BLOCK C LOT 58X, BLOCK C COPPELL GREENS PHASE TWO CAB. R, SLIDE 104, O.P.R.De.C.T. DENT O N C O U N T Y DALL A S C O U N T Y TURNBERRY LANE(VARIABLE WIDE PUBLIC R.O.W.) STATE HIGHWAY 121 EX. 10' DRAINAGE EASEMENT CITY OF COPPELL, TEXAS INS. NO. 200402885527, O.P.R.D.C.T. EX. 10' EASEMENT COSERV ELECTRIC INS. NO. 2004-138839, O.P.R.De.C.T. EX. 5' UTILITY EASEMENT CAB. P, SLD. 160, O.P.R.De.C.T. EX. 7.5' UTILITY EASEMENT CAB. P, SLD. 160, O.P.R.De.C.T. EX. 7.5' UTILITY EASEMENT CAB. R, SLD. 104, O.P.R.De.C.T. 5/8" CIRF SURVCON INC. 5/8" CIRF BHB INC. 5/8" CIRF BHB INC. EX. DRAINAGE & UTIL. EASEMENT CAB. R, SLD. 104, O.P.R.De.C.T. 30' SIDE YARD SETBACK POINT OF BEGINNING 202 CP X-CUT EL = 471.08 N= 7046891.12 E= 2429862.97 TBM #1 BM X CUT N=7047212.89 E=2429692.59 EL=478.33 205 CP X-CUT EL = 471.24 N= 7047051.20 E= 2429965.96 206 CP X-CUT EL = 472.52 N= 7047137.31 E= 2429940.35 201 EL = 474.35 N= 7047042.10 E= 2429588.06 207 CP X-CUT EL = 472.32 N= 7046984.49 E= 2429619.87 204 CP X-CUT EL = 471.48 N= 7046963.68 E= 2429864.16 203 CP X-CUT EL = 421.29 N= 7046918.01 E= 2429754.38 TBM #2 BM X CUT N=7046895.02 E=2429865.07 EL=470.94 EX. 20' EASEMENT TEXAS UTILITIES ELECTRIC CO. & COSERV, LLC VOL. 99036, PG. 1401, O.P.R.Da.C.T. EX. 10' SIDEWALK EASEMENT D.C.C.I. NO. 201800044533, O.P.R.Da.C.T. EX. 24' FIRE LANE & MUTUAL ACCESS EASEMENT D.C.C.I. NO. 201800044533, O.P.R.Da.C.T. EX. 10' DRAINAGE EASEMENT CAB. V, SLD. 727, O.P.R.De.C.T. EX. 24' FIRE LANE & MUTUAL ACCESS EASEMENT D.C.C.I. NO. 201800044533, O.P.R.Da.C.T. EX. 10' SIDEWALK EASEMENT D.C.C.I. NO. 201800044533, O.P.R.Da.C.T. EX. 15' PRIVATE DRAINAGE EASEMENT D.C.C.I. NO. 201800044533, O.P.R.Da.C.T. EX. 20' SANITARY SEWER EASEMENT CITY OF COPPELL VOL. 98146, PG. 4736, O.P.R.Da.C.T. VOL. 4155, PG. 21, O.P.R.De.C.T. EX. 20' UTILITY EASEMENT VOL. 2004093, PG. 28, O.P.R.Da.C.T. EX. 20' DRAINAGE EASEMENT INS. NO. 200402888858, O.P.R.De.C.T. EX. 20' SANITARY SEWER EASEMENT CAB. P, SLD. 160, O.P.R.De.C.T. 20' REAR YARD SETBACK 60' FRONT YARD SETBACK PROP. 24" ACCESS AND FIRE LANE EASEMENT EX. 20' UTILITY EASEMENT INS. NO. 200402888858, O.P.R.Da.C.T. PROP. 24" ACCESS AND FIRE LANE EASEMENT PROP. 24" ACCESS AND FIRE LANE EASEMENT L6 L1 L2 L4L5L7L8 L9 L10 L11 L12 C1 C2 L3 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14L13L15L16 L14 S66° 29' 20"E ~ 107.54' N89° 5 9' 5 4 " E ~ 164. 4 8'S23° 26' 05"W~ 328.60'N60° 48' 33"W ~ 133.94' N66° 36' 18"W ~ 125.15'N23° 25' 32"E~ 249.98'EX. 20' EASEMENT TO CITY OF COPPELL VOL. 2004093, PG. 23 O.P.R.Da.C.T. PROP. 10' SIDEWALK EASEMENT 30' SIDE YARD SETBACK LOT 2A COPPELL ENTERTAINMENT PLAZA 0.0701 ACRES CALLED: 0.0701ACRES COPPELL PKB, LLC. INS. NO. 2024133334, O.P.R.Da.C.T. SHEET 1 OF 2 O.P.R.De.C.T. O.P.R.Da.C.T.OFFICIAL PUBLIC RECORDS DENTON COUNTY, TEXAS CIRF IRON ROD WITH CAP FOUND INS. NO.DENTON COUNTY CLERK'S INSTRUMENT NUMBER CAB.CABINET PG.PAGE R.O.W.RIGHT-OF-WAY ENGINEER: MINOR PLAT PREPARED: FEBRUARY 10, 2025 LOT 1, BLOCK A COPPELL ENTERTAINMENT PLAZA D.B.T.P.DEDICATED BY THIS PLAT PROJECT LOCATION * VICINITY MAP * (NOT TO SCALE) W P A R K W A Y B L V D 121 N COPPELL RDBus 121RIDGE W O O D D R W S H 1 2 1 DENTON COUNTY DALLAS COUNTY KILBRIDGE LN DENTON TAP RDHIGHLAND DROAKBEND DROffices conveniently located throughout the United States: New Jersey | Delaware | Florida | Maryland | Pennsylvania | Texas www.dynamicec.com 714 S. Greenville Avenue - Suite 100 Allen, TX 75002 T: 972.534.2100 Texas Registered Engineering Firm No. F-13660 THIS DOCUMENT IS PRELIMINARY FOR REVIEW PURPOSES ONLY FEBRUARY 10, 2025 BEING A MINOR PLAT OF A 1.6 ACRE TRACT OF LAND LOCATED WITHIN CLARINDA SQUIRES SURVEY ABST. NO 1682, CITY OF COPPELL, DENTON COUNTY, TEXAS AND IN THE CLARINDA SQUIRES SURVEY ABST. NO. 1327, CITY OF DALLAS, DALLAS COUNTY, TEXAS ZONING: HIGHWAY COMMERCIAL (HC) OWNER: COPPELL PKB, LLC 3120 GOLDEN SPRINGS DR PLANO, TX 75025 T: 972-3027625 EMAIL: JASONC@INDOORPICKLEBALLNOW.COM IRF IRON ROD FOUND OFFICIAL PUBLIC RECORDS DENTON COUNTY, TEXAS CURVE TABLE CURVE #RADIUS LENGTH CH BEARING CH LENGTH C1 30.00'33.26'N79° 41' 05"E 31.59' C2 53.99'40.15'N69° 13' 18"E 39.23' C3 30.00'7.69'S26° 10' 26"E 7.67' C4 15.00'24.93'S81° 07' 18"E 22.16' C5 4.18'7.80'N34° 44' 24"E 4.13' C6 30.00'42.99'S20° 11' 39"E 39.40' C7 30.00'47.12'N21° 37' 04"W 42.43' C8 30.00'47.12'N68° 22' 39"E 42.42' C9 54.00'20.50'N80° 30' 32"W 20.37' C10 30.00'12.67'N79° 17' 15"W 12.57' C11 54.00'24.88'N80° 23' 36"W 24.66' C12 29.25'11.21'N82° 44' 42"W 11.14' C13 185.65'2.84'N68° 22' 40"W 2.84' C14 52.44'4.83'N63° 13' 41"W 4.82' LINE TABLE LINE #BEARING DISTANCE L1 N66° 37' 04"W 184.46' L2 N89° 28' 40"W 21.26' L3 N51° 49' 28"E 1.04' L4 N23° 24' 56"E 156.54' L5 N61° 14' 40"W 1.35' L6 S66° 37' 04"E 175.76' L7 S23° 22' 56"W 93.23' L8 N66° 38' 55"W 138.67' L9 N67° 11' 31"W 5.17' L10 S67° 11' 31"E 2.51' L11 S66° 37' 04"E 151.62' L12 S59° 30' 15"E 62.45' L13 N23° 25' 32"E 12.00' L14 S66° 34' 28"E 12.00' L15 S23° 25' 32"W 12.00' L16 N66° 34' 28"W 12.00' 47 * DEDICATION STATEMENT * * GENERAL NOTES * ·The bearings, distances and coordinates shown hereon are referenced to the Texas Coordinate System of 1983, Texas North Central Zone 4202, and are based on the North American Datum of 1983, 2011 Adjustment. Coordinates shown are scaled to surface distances at N: 0.0 and E: 0.0 using a combined scale factor of 1.000150630. All areas shown hereon are calculated based on surface measurements. ·Vertical control is NAVD88 established from City of Coppell benchmark ID 10, having a published elevation of 463.69'. ·This survey was prepared without the benefit of a Title Commitment prepared by a title company. The easements shown hereon are the only easements known by Spooner & Associates and does not imply that any other easements, covenants, restrictions, or other matters of record do not affect the subject property. No other research was performed by Spooner & Associates, Inc. ·The subject tract appears to be located within Zone "HC" (Highway Commercial) according to the City of Coppell zoning map. The Surveyor did not attempt to interpret the zoning district information mentioned herein. Hereby, the Surveyor advises all interested parties to contact the City of Coppell Planning and Zoning Department to further verify all zoning regulations and restrictions before planning, designing, constructing, or developing on the subject property. ·According to the Flood Insurance Rate Map published by the Federal Emergency Management Agency, Department of Homeland Security and by graphic plotting only, the subject property appears to be located in Zone "X" (areas determined to be outside the 0.2 % annual chance floodplain) as shown on Map No. 48113C0155K; map revised July 7, 2014, for Dallas County and incorporated areas and also shown on Map No. 48121C0705G; map revised April 18, 2011, for Denton County and incorporated areas. This flood statement does not imply that the property and/or structures located in Zone "X" will be free from flooding or flood damage. This flood statement shall not create liability on the part of the Surveyor. ·Underground utilities shown hereon were taken from plans and/or reports provided to the Surveyor by others and from markings set by Texas811. Provided information combined with Texas811 markings and observed evidence of utilities was used to develop a view of the underground utilities. However, lacking excavation, the exact location of underground features cannot be accurately, completely and reliably depicted. No attempt has been made as a part of this Survey to confirm, obtain or show data concerning the depth or condition of any utility or municipal/public service facility. Subsurface and environmental conditions were not examined or considered as a part of this Survey. No statement is made concerning the existence of underground or overhead containers or facilities, which may affect the use or development of the subject tract of land. Where additional or more detailed underground utility information is required, the client is hereby advised that excavation may be necessary. ·All manhole / vault invert data provided hereon (eg. pipe sizes, pipe types, flowline elevations) is measured or estimated from the top of the structure by field crew personnel. While reasonable precautions are always taken, Spooner and Associates expressly assumes no liability for the risk of obtaining incorrect values inherent when making indirect measurements or estimates. No underground utility structures are entered by Spooner personnel to obtain measurements due to safety concerns. ·The size or shape of the tree/bush symbols included hereon do not necessarily represent the actual size and shape of the corresponding trees/bushes or their canopies. They represent location only. * OWNER'S CERTIFICATION * STATE OF TEXAS § COUNTY OF COPPELL § WHEREAS, COPPEL PKB, LLC is the sole owner of a 1.6 acre tract of land located within Clarinda Squires Survey Abst. No 1682, City of Coppell, Denton County, Texas and in the Clarinda Squires Survey Abst. No. 1327, city of Dallas, Dallas County, Texas. Abstract No. 437, and the W. J. Jackson Survey, Abstract No. 671, City of Carrollton, Denton County, Texas, said 1.6 acre tract of land being land conveyed to COPPEL PKB, LLC. Said 1.6 acre tract of land being more particularly described by metes and bounds as follows based on Instrument No. 201900233593 recorded in Dallas County and Topographic Survey prepared by Spooner & Associates on January 21, 2025: BEGINNING at a 1/2-inch rebar found for the Southwest corner of RS Denton Tap tract, same being the Southeast corner of Lot 2R, Block 1, of Coppell/121 Office Park in addition to the City of Coppell, Denton/Dallas Counties, Texas according to the Plat thereof recorded in Instrument No. 200600248548 (O.P.R.D.C.T), and lying on the Northeast right-of-way line of State Highway 121 (Variable Width right-of-way; THENCE North 23°25'32” East, departing the Northeast right-of-way line of said State Highway 121, with the East line of said Lot 2R, a distance of 249.98 feet to a 5/8 inch rebar found for the Northwest corner of said RS Denton Tap tract, same being the Northeast corner of said Lot 2R, and lying on the Southwest line of Lot 18X of Coppell Greens Phase One, an addition to the City of Coppell, Denton County, Texas according to the Plat thereof recorded in Cabinet P, Page 160 oof the Plat Reports of Denton County, Texas; THENCE South 66°29'20” East, with the Suth line of said Coppell Greens Phase One, a distance3 of 107.54 feet to a 5/8 inch rebar with a cap stamped “Survcon” found for corner; THENCE North 89°59'54” East, continuing with the South line of said Coppell Greens Phase One, a distance of 54.48 feet to a 5/8-inch rebar with a cap stamped “BHB” found for the Northeast corner of said RS Denton Tap tract, same being the Northwest corner of Lot 1, block A, of North Gateway Plaza, an addition to the City of Coppell, Dallas County, Texas according to the Plat thereof recorded in Instrument No. 201800044533 (O.P.R.D.C.T); THENCE South 23°26'05” West, departing the South line of said Coppell Greens Phase One, with the West line of said Lot 1, a distance of 328.60 feet to a 5/8-inch rebar with a cap stamped “BHB” found for the Southeast corner of said RD Denton Tap Tract, same being the Southwest corner of Lot 1, and lying on the Northeast right-of-way line of said State Highway 121; THENCE North 60°48'33” West, with the Northeast right-of-way line of said State Highway 121, a distance of 133.94 feet to a ½-inch rebar found for corner; THENCE North 66°36'18” West, continuing with the Northeast right-of-way line of said State Highway 121, a distance of 125.12 feet to the POINT OF BEGINNING and containing a total of 70,388 square feet or 1.6159 acres of lane, more or less. NOW THEREFORE, KNOW ALL MEN BY THESE PRESENTS: That, COPPELL PKB, LLC., does hereby adopt this plat designating the herein described property as COPPELL ENTERTAINMENT PLAZA, Lot 1, Block A, an addition to the City of Coppell, Texas, and does hereby dedicate, in fee simple, to the public use forever the streets shown thereon. The easements shown thereon are hereby reserved for the purposes indicated. The utility and fire lane easements shall be open to the public, fire and police units, garbage and rubbish collection agencies, and all public and private utilities for each particular use. The maintenance of paving on the utility and fire lane easements is the responsibility of the property owner. No buildings, fences, trees, shrubs, or other improvements or growths shall be constructed, reconstructed or placed upon, over or across the easements shown. Said easements being hereby reserved for the mutual use and accommodation of all public utilities using or desiring to use same. All and any public utility shall have the right to remove and keep removed all or parts of any buildings, fences, trees, shrubs, or other improvements or growths which in any way endanger or interfere with the construction, maintenance or efficiency of its respective right or ingress or egress to or from and upon the said easement for the purpose of constructing, reconstructing, inspecting, patrolling, maintaining and adding to or removing all or parts of its respective systems without the necessity at any time of procuring the permission of anyone. (Any public utility shall have the right to ingress or egress to private property for the purpose of reading meters and any maintenance or service required or ordinarily performed by the utility). Water main and wastewater easements shall also include additional areas of working space for construction and maintenance of the systems. Additional easement area is also conveyed for installation and maintenance of manholes, cleanouts, fire hydrants, water services and wastewater services from the main to the curb or pavement line, and description of such additional easements herein granted shall be determined by their location as installed. This plat approved subject to all platting ordinances, rules, regulations, and resolutions of the City of Coppell, Texas. WITNESS, my hand this the ___ day of ____, 2025. __________________________ ________________ NAME TITLE STATE OF TEXAS § COUNTY OF DENTON § BEFORE ME, the undersigned, a Notary Public in and for said County and State, on this day personally appeared ________________, of __________, known to me to be the person and officer whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same for the purposes and considerations therein expressed, and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE, this the _______day of _______, 2025. ___________________________________ Notary Public in and for the State of Texas Floodplain Development Permit Application No. ___ has been filed with the City of Coppell floodplain administrator on __________________, 2025. __________________________________________________________ Floodplain Administrator Date Approved and Accepted: _________________________________________________________ Chairman, Planning and Zoning Commission Date City of Coppell, Texas The undersigned, the Planning and Zoning Commission Secretary of the City of Coppell, Texas, hereby certifies that the foregoing plat of COPPELL ENTERTAINMENT PLAZA, Lot 1, Block A, an addition to the City of Coppell was submitted to the Planning and Zoning Commission on the ____ day of ________, 2025, and the Planning and Zoning Commission, by formal action, then and there accepted the dedication of streets, alleys, parks, easements, public places, and water and sewer lines, as shown and set forth in and upon said plat, and said Chairman to note the acceptance thereof by signing his name as hereinabove subscribed. Witness my hand this _____ day of _________, A.D., 2025. ___________________________ Planning and Zoning Commission Secretary, City of Coppell, Texas ______________________________________________________________________________________ “I, _________________________ (Engineer), verify that all franchise utilities have each been contacted and provided a copy of the plat and development proposal and all franchise utility easements and/or abandonments are currently shown.” SURVEYOR'S CERTIFICATE KNOW ALL MEN BY THESE PRESENTS: That I, _____, a Registered Professional Land Surveyor, do hereby certify that I have prepared this plat from an actual on the ground survey of the land; and the monuments shown hereon were found and/or placed under my personal supervision in accordance with the platting rules and regulations of the City of Coppell, Texas. ______________________ NAME Registered Professional Land Surveyor No. ______ STATE OF TEXAS § COUNTY OF DENTON § BEFORE ME, the undersigned, a Notary Public in and for said County and State, on this day personally appeared ________________, of __________, known to me to be the person and officer whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same for the purposes and considerations therein expressed, and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE, this the _______day of _______, 2025. ___________________________________ Notary Public in and for the State of Texas SHEET 1 OF 2 ENGINEER: MINOR PLAT PREPARED: FEBRUARY 10, 2025 LOT 1, BLOCK A COPPELL ENTERTAINMENT PLAZA Offices conveniently located throughout the United States: New Jersey | Delaware | Florida | Maryland | Pennsylvania | Texas www.dynamicec.com 714 S. Greenville Avenue - Suite 100 Allen, TX 75002 T: 972.534.2100 Texas Registered Engineering Firm No. F-13660 THIS DOCUMENT IS PRELIMINARY FOR REVIEW PURPOSES ONLY FEBRUARY 10, 2025 BEING A MINOR PLAT OF A 1.6 ACRE TRACT OF LAND LOCATED WITHIN CLARINDA SQUIRES SURVEY ABST. NO 1682, CITY OF COPPELL, DENTON COUNTY, TEXAS AND IN THE CLARINDA SQUIRES SURVEY ABST. NO. 1327, CITY OF DALLAS, DALLAS COUNTY, TEXAS ZONING: HIGHWAY COMMERCIAL (HC) OWNER: COPPELL PKB, LLC 3120 GOLDEN SPRINGS DR PLANO, TX 75025 T: 972-3027625 EMAIL: JASONC@INDOORPICKLEBALLNOW.COM 48 ITEM # 8 Page 1 of 2 1ITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT Public Hearing: Text Amendments to the Code of Ordinances Chapter 12, “Zoning”, Article 42, Special Definitions; Article 25, Light Industrial District; & Article 31, Off-Street Parking Requirements P&Z HEARING DATE: February 20, 2025 C.C. PUBLIC HEARING DATE March 11, 2025 STAFF REP.: Matthew Steer, AICP, Development Services Administrator PURPOSE: PUBLIC HEARING: Consider text change amendments to the Code of Ordinances, Chapter 12, Article 42, Special Definitions to add definitions for “showroom”, “warehouse”, “distribution center”, “fulfillment center”, and “retail center”; and, to amend Article 25, Light Industrial District, of said chapter to add said new definitions to permitted uses; and, to amend Article 31 of said chapter to allow conversion of dock areas to additional parking, to allow “warehouse”, “distribution center” and “fulfillment center” as defined herein to require not less than one (1) parking space per 2,000 square feet, “showroom” as defined herein to require not less than one (1) parking space per 1,000 square feet; to allow the Director of Community Development to approve up to a 10% reduction in parking for retail centers with buildings greater than 10,000 square feet. HISTORY: A portion of this proposed code amendment was brought before the Planning and Zoning Commission in October 2024. After the recommendation for approval by the Commission, staff paused on proceeding to City Council to combine all the parking related amendments and to add definitions for specific land uses. DISCUSSION: These are text amendments to the Zoning Ordinance that allow for more flexibility in parking for industrial and retail users as previously recommended for approval by the Planning and Zoning Commission in October 2024. The additional changes include definitions for specific uses not currently listed. Off-Street Loading/Dock Area Parking: This proposed amendment was the result of an Industrial 2.0 Roundtable held with industrial developers to discuss the future trends in Industrial type uses. During that roundtable, it was the consensus that the uses within the developments could change, which would necessitate the need for more off-street parking. This proposed amendment allows for conversion of the dock areas to standard parking spaces within an existing site within the Light Industrial District, provided the area is screened from view with either evergreen landscaping or a screening wall. Currently, a conversion of dock areas to car parking would necessitate a Minor Site Plan Amendment and would need approval prior to 51 ITEM # 8 Page 2 of 2 applying for a building permit. With this amendment, the change would be allowed by right and could be done directly at the time of building permit. The amendment would allow more flexibility for reconfiguration of the site to accommodate standard passenger vehicles for a change in tenant or operations of an existing tenant. If there is a need to convert these areas back, this too could easily be done. The Planning and Zoning Commission unanimously recommended approval of this amendment in October 2024. Parking: This amendment was also the result of the Industrial 2.0 Roundtable. During that roundtable, it was the consensus that with the increased use of technology within the industrial developments, the number of employees per square feet has decreased. It was recommended that staff research decreasing our minimum parking requirements. While staff is recommending that “showrooms” continue to have a parking requirement of 1 parking space per 1,000 square feet, the “warehouse”, “distribution center”, and “fulfillment center” uses are proposed to require one parking space per 2,000 square feet or one per employee on the maximum working shift. This is consistent with the recommendation given by the Planning and Zoning Commission in October 2024. Additions/Amendments to the Special Definitions: These further clarify the types of uses within the Light Industrial District and are defined as follows: ▪ Distribution Center - an established location that stores goods purchased by the operator for resale, that does engage in storing goods for hire, and where goods are not sold to retail customers. ▪ Fulfillment Center - an established location operated to receive orders from retail customers, placed primarily over the Internet through the use of websites, for purchase of goods held in inventory at that location that are shipped or delivered from the center directly to the place designated by the purchaser. A fulfillment center does not store goods for hire. It keeps or retains goods for sale to retail customers in the regular course of business. It is not a warehouse or a distribution center. ▪ Showroom - a room or area in excess of one thousand square feet where durable goods are displayed for retail sales to consumers. ▪ Warehouse - an established location engaged in storing goods for hire for multiple parties that does not sell goods in the regular course of business and that does not store goods that the operator has purchased for resale. “showroom”, “warehouse”, “distribution”, “fulfillment center”, and “retail center” A definition for Retail Center is also proposed to be included to coincide with the proposed parking variance. The definition is as follows: ▪ Retail store(s), shop(s) and Retail Center- established locations that display and sell goods in-person to consumers, but excluding the display and sale in the open, outside a building, of new or used automobiles, heavy machinery, building materials, used appliances, furniture or salvage materials. 52 ITEM # 8 Page 3 of 2 Parking for Retail Centers Over 10,000 sq. ft. in Building Area: The next text amendment was the result of a Retail Roundtable held with retail developers to discuss the future trends in retail. During the roundtable, the parking requirements for retail centers was brought up. The parking requirements of the Zoning Ordinance are based on extreme cases, during peak times, and often there is a large amount of parking that is never utilized except during the holidays. The proposed amendment would authorize the Director of Community Development to approve a reduction of the number of required parking spaces not to exceed a 10% reduction; however, any reduction greater than 5% shall require a parking study and alternate parking plan obtained by the owner or developer of the property that is prepared by a licensed transportation engineer. Originally, staff’s recommendation did not have a limit. In October 2024, the Planning and Zoning Commission recommended that a 10% reduction be the limit. This has now been introduced in the proposed changes. Greater flexibility in administering the parking requirements allows for more potential businesses to fill the retail centers. The redlined ordinance changes are attached for your review. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff is recommending approval of the Zoning Ordinance text amendments. ALTERNATIVES: 1. Recommend approval of the request 2. Recommend disapproval of the request 3. Recommend modification of the request 4. Take under advisement for reconsideration at a later date ATTACHMENTS: 1. Redlined Sec 12-25-1 Use Regulations 2. Redlined Sec 12-31-6 Parking Requirements Based on Use 3. Redlined Sec 12-31-7 Rules for Computing Number of Parking Spaces 4. Redlined Sec 12-31-3 Off Street Loading Space All Districts 5. Relined Sec 12-42-1 Definitions 53 Created: 2025-01-10 08:29:35 [EST] (Supp. No. 52) Page 1 of 2 Sec. 12-25-0. General purpose and description. The LI light industrial district is intended to provide for commercial and light manufacturing uses. (Ord. No. 91500-A-129) Sec. 12-25-1. Use regulations. The following uses are permitted in the "LI" district, provided that such manufacturing or industrial operation shall not disseminate dust, fumes, gas, noxious odor, smoke, glare, or other atmospheric influence beyond the boundaries of the property on which such use is located and which produces no noise exceeding in intensity at the boundary of the property the average intensity of noise of street traffic at that point and provided that such use does not create fire hazards on surrounding property. 1. Any use permitted in any of the "O" office, "R" retail, and "C" commercial districts. 2. Apparel and other products assembled from finished textiles. 3. Bottling works. 4. Carting, express, hauling or storage yard. 5. Contractor's yard. 6. Cosmetic manufacturer. 7. Distribution Center. 7.8. Drugs and pharmaceutical products manufacturing. 8.9. Electronic products manufacturing. 10. Fulfillment Center. 9.11. Fur goods manufacture, but not including tanning or dyeing. 10.12. Glass products from previously manufactured glass. 11.13. Household appliance products assembly and manufacture from prefabricated parts. 12.14. Industrial and manufacturing plants including the processing or assembling of parts for production of finished equipment where the process of manufacturing or treatment of materials is such that only a nominal amount of dust, odor, gas, smoke or noise is emitted and not more than 20 percent of the lot or tract is used for the open storage of products, materials, or equipment. 13.15. Musical instruments assembly and manufacture. 14.16. Plastic products manufacture, but not including the processing of raw materials. 17. Showroom. 15.18. Sporting and athletic equipment manufacture. 16.19. Testing and research laboratories. 17.20. Housing prefabrication. 18.21. General warehousing activities (including convenience storage or "mini warehouse"). 22. Veterinarian clinic (outside kennels). 19.23. Warehouse. 54 Created: 2025-01-10 08:29:35 [EST] (Supp. No. 52) Page 2 of 2 20.24. Any uses permitted by special use permit, section 12-30-12. 21.25. Technology equipment facility. 22.26. Oil and gas drilling and extraction. (Ord. No. 91500-A-129; Ord. No. 91500-A-334, § 3, 8-13-02; Ord. No. 91500-A-451, § 1, 2-13-07) 55 Created: 2024-03-20 09:38:07 [EST] (Supp. No. 51) Page 1 of 3 Sec. 12-31-6. Parking requirements based on use. In all districts there shall be provided at the time any building or structure is erected or structurally altered, off-street parking spaces in accordance with the preceding provisions and in accordance with the following requirements: 1. Auto laundry: One space per 500 square feet of gross floor area. 2. Bowling alley: Six parking spaces for each alley or lane. 3. Business or professional office, (general): One space per 300 square feet of gross floor area. 4. Church or other place of worship: One parking space for each three seats in the main auditorium. 5. College or university: One space per each day student. 6. Community center, library, museum, or art gallery: Ten parking spaces plus one additional space for each 300 square feet of floor area in excess of 2,000 square feet. If an auditorium is included as a part of the building, its floor area shall be deducted from the total and additional parking provided on the basis of one space for each four seats that it contains. 7. Commercial amusement: One space per three guests or one space per 100 square feet of gross floor area, whichever is greater. 8. Dance hall, assembly or exhibition hall without fixed seats: One parking space for each 100 square feet of floor area thereof. 9. Day nursery: One space per ten pupils. 10. Distribution Center: One parking space for each employee on the maximum working shift plus space to accommodate all trucks and other vehicles used in connection therewith, but not less than one parking space for each 2,000 square feet of floor area. 10.11. Dwellings, multi-family: Two spaces per one and two bedroom units and two and one-half spaces per three bedroom unit. 11.12. Fraternity, sorority, or dormitory: One parking space for each two beds. 13. Fulfillment Center: One parking space for each employee on the maximum working shift plus space to accommodate all trucks and other vehicles used in connection therewith, but not less than one parking space for each 2,000 square feet of floor area. 12.14. Furniture or appliance store, hardware store, wholesale establishments, machinery or equipment sales and service, clothing or shoe repair or service: Two parking spaces plus one additional parking space for each 300 square feet of floor area over 1,000. 13.15. Gasoline station: Minimum of six spaces. 14.16. Hospital: One space per employee on the largest shift, plus one and one -half spaces for each bed. 15.17. Hotel: One parking space for each one sleeping rooms or suites plus one space for each 200 square feet of commercial floor area contained therein. 16.18. Library or museum: Ten spaces plus one space for every 300 square feet. 17.19. Lodge or fraternal organization: One space per 200 square feet. 18.20. Manufacturing or industrial establishment, research or testing laboratory, creamery, bottling plant, warehouse, printing or plumbing shop, or similar establishment: One parking space for each 56 Created: 2024-03-20 09:38:07 [EST] (Supp. No. 51) Page 2 of 3 employee on the maximum working shift plus space to accommodate all trucks and other vehicles used in connection therewith, but not less than one parking space for each 1,000 square feet of floor area. 19.21. Medical or dental office: One space per 175 square feet of floor area. 20.22. Mini-warehouse (convenience storage): Four per complex plus one per 3,000 square feet of storage area. When access to individual storage units is adjacent to a fire lane, parallel (8′ × 22′) parking spaces shall be provided adjacent to the storage units. These parking spaces will be outside of the designated fire lane and are only required adjacent to one side of the fire lane. a. One parking space shall also be provided per 500 square feet of floor area of caretaker's quarters; however, no more than two spaces are required for each caretaker's quarters. 21.23. Mobile home park: Two spaces for each mobile home plus additional spaces as required herein for accessory uses. 22.24. Mortuary or funeral home: One parking space for each 50 square feet of floor space in slumber rooms, parlors or individual funeral service rooms. 23.25. Motel: One parking space for each sleeping room or suite plus one space for each 200 square feet of commercial floor area contained therein. 24.26. Motor-vehicle sales rooms and used car lots: One parking space for each 500 square feet of sales floor for indoor uses, or one parking space for each 1,000 square feet of lot area for outdoor uses. 25.27. Nursing home: One space per five beds and one for each day staff. 26.28. Private club, country club or golf club: One parking space for each 150 square feet of floor area or for every five members, whichever is greater. 27.29. Retail store or personal service establishment, except as otherwise specified herein: One space per 200 square feet of gross floor area. 28.30. Restaurant, night club, cafe or similar recreation or amusement establishment: a. One parking space for each 100 square feet of floor area. b. Where drive-through facilities are provided, there shall be a minimum of five stacking spaces behind the first point of order. Stacking/queuing shall not be permitted in a designated fire lane. 29.31. Rooming or boardinghouse: One parking space for each sleeping room. 30.32. Sanitarium, convalescent home, home for the aged or similar institution: One parking space for each five beds. 31.33. School, elementary: One parking space for each five seats in the auditorium or main assembly room, or one space for each classroom plus six spaces, whichever is greater. 32.34. School, secondary, and college: One parking space for each four seats in the main auditorium or eight spaces for each classroom, whichever is greater. 35. Showroom: One parking space for every 1,000 square feet. 33.36. Theater, auditorium (except school), sports arena, stadium, or gymnasium: One parking space for each three seats or bench seating spaces. 34.37. Golf course: Three parking spaces per hole. 38. Technology equipment facility: One space per 2,500 square feet of gross floor area devoted to technology or computer equipment, plus additional parking as required in section 12 -31 for all accessory uses, such as office, meeting or technical workspace. 57 Created: 2024-03-20 09:38:07 [EST] (Supp. No. 51) Page 3 of 3 35.39. Warehouse: One parking space for each employee on the maximum working shift plus space to accommodate all trucks and other vehicles used in connection therewith, but not less than one parking space for each 2,000 square feet of floor area. (Ord. No. 91500; Ord. No. 91500-A-322, § 1, 4-9-02; Ord. No. 91500-A-331, § 1, 8-13-02; Ord. No. 91500-A-334, § 2, 8-13-02) Sec. 12-31-7. Rules for computing number of parking spaces. In computing the number of parking spaces required for each of the above uses the following rules shall govern: 1. "Floor area" shall mean the gross floor area of the specific use. 2. Where fractional spaces result, the parking spaces required shall be constructed to be the nearest whole number. 3. The parking space requirement for a use not specifically mentioned herein shall be the same as required for a use of similar nature. 4. Whenever a building constructed and issuance of its initial certificate of occupancy results in an increase in the number of employees, dwelling units, seating capacity, and/or modifies its use, the building official shall recalculate the number of required parking spaces as provided in this article. In the event the recalculation results in an increase in the number of required spaces, the owner or occupant must comply with the recalculated parking requirements or seek a special exception under this chapter. 5. In the case of mixed uses, the parking spaces required shall equal the sum of the requirements of the various uses computed separately. (Ord. No. 91500; Ord. No. 91500-A-532, § 1, 10-13-09) 58 Created: 2024-03-20 09:38:07 [EST] (Supp. No. 51) Page 1 of 1 Sec. 12-31-7. Rules for computing number of parking spaces. In computing the number of parking spaces required for each of the above uses the following rules shall govern: 1. "Floor area" shall mean the gross floor area of the specific use. 2. Where fractional spaces result, the parking spaces required shall be constructed to be the nearest whole number. 3. The parking space requirement for a use not specifically mentioned herein shall be the same as required for a use of similar nature. 4. Whenever a building constructed and issuance of its initial certificate of occupancy results in an increase in the number of employees, dwelling units, seating capacity, and/or modifies its use, the building official shall recalculate the number of required parking spaces as provided in this article. In the event the recalculation results in an increase in the number of required spaces, the owner or occupant must comply with the recalculated parking requirements or seek a special exception under this chapter. 5. In the case of mixed uses, the parking spaces required shall equal the sum of the requirements of the various uses computed separately. 5.6. For retail centers greater than 10,000 square feet in building area, the Director of Community Development is authorized to approve a reduction of the number of required parking spaces not to exceed a ten percent (10%) reduction; however, any reduction greater than 5% shall require a parking study and alternate parking plan obtained by the owner or developer of the property that is prepared by a licensed transportation engineer. (Ord. No. 91500; Ord. No. 91500-A-532, § 1, 10-13-09) 59 Created: 2024-03-20 09:38:07 [EST] (Supp. No. 51) Page 1 of 1 Sec. 12-31-3. Off-street loading space, all districts. 1. All retail, commercial, and industrial structures having 5,000 square feet or more of gross floor area shall provide and maintain off-street parking facilities for the loading and unloading of merchandise and goods at a ratio of at least one space for the first 20,000 square feet of gross floor area and one space for each additional 20,000 square feet of gross floor area or fraction thereof for a building larger than 5,000 square feet. A loading space shall consist of an area of a minimum of 12 by 30 feet. All drives and approaches shall provide adequate space and clearances to allow for the maneuvering of trucks off -street. 2. Kindergartens, day schools, and similar child training and care establishments shall provide paved off -street loading and unloading space on a through "circular" drive or shall provide a minimum of three parking spaces by the main entrance plus one parking space for every ten children. Parking shall be designed to accommodate one motor vehicle for every ten students or children cared for by the establishment. 3. Uses not listed in Schedule 31.6 shall provide required off-street parking according to the most similar use listed in the schedule, as determined by the city council. 4. Loading docks and areas shall not be located on the street side of any structure unless screened according to section 12-33-1(4). 5. Existing loading dock areas of warehouse/distribution sites within the Light Industrial District may be converted to additional off-street parking spaces provided the area is screened from public view or adjacent property with evergreen landscaping in accordance with Section 12-34-7 General Standards, or with a masonry screening wall in accordance with Section 12-33 Screening Standards. (Ord. No. 91500; Ord. No. 91500-A-794 , § 1, 7-11-23) 60 Created: 2025-01-10 08:29:38 [EST] (Supp. No. 52) Page 1 of 11 Sec. 12-42-1. Definitions. Certain words in this Ordinance not heretofore defined are defined as follows: Words used in the present tense include the future; words in the singular number include the plural number, and words in the plural number include the singular number; the word "building" includes the word "structure"; the word "lot" includes the words "plot" or "tract"; the word "shall" is mandatory and not discretionary. Accessory building or use: One which: (a) is subordinate to and serves a principal use; and (b) is subordinate in area, extent, or purpose to the principal building or principal use served; and (c) contributes to the comfort, convenience and necessity of occupants of the principal building or principal use served; and (d) is located on the same building lot as the principal use served. "Accessory" when used in the text shall have the same meaning as accessory use. An accessory building may be a part of the principal building. Servants' quarters, as defined, are an accessory building or use. Alley: A public right-of-way which affords a secondary means of access to abutting property. Alterations: Any change, addition, or modification in construction, any change in the structural members of a building, such as walls or partitions, columns, beams or girders, the consummated act of which may be referred to herein as "altered" or "reconstructed." Apartment: A dwelling unit in an apartment building occupied as a place of residence. Apartment building: An "apartment building" is a building or any portion thereof, which contains three or more dwelling units, located in the same building lot. An apartment building is a multi -family dwelling. Assembly and manufacturing (limited): The assembly, repair, disassembly and manufacturing of finished products or parts from previously prepared materials and parts. Fabrication may be used in limited form to shape or define the final product, but shall not comprise the primary activity of su ch operations. Basic industrial processing, which transforms raw materials into a new substance, compound or product, is not permitted. Excluded uses include, but are not limited to, meat packing, chemical and petroleum processing and manufacturing, and foundries. Auto laundry: A building, or portion thereof containing facilities for washing automobiles using automated methods including chain conveyor, blower, steam cleaning device, or other mechanical devices. A self -service type car wash is an auto laundry. Automobile repair, major: Major repair, rebuilding, or reconditioning of engines or transmissions for motor vehicles; wrecker service with vehicle storage; collision services including body, frame or fender straightening or repair; customizing; overall painting or paint shop; thos e uses listed under "automobile repair, minor"; and other similar uses. Automobile repair, minor: Minor repair or replacement of parts, tires, tubes, and batteries; diagnostic services; minor motor services such as grease, oil, spark plug, and filter changing; tune -ups; emergency road service; replacement of starters, alternators, hoses, brake parts; mufflers; automobile washing, steam cleaning, and polishing; performing state inspections and making minor repairs necessary to pass said inspection; servicing of air-conditioning systems, and other similar minor services for motor vehicles except heavy load vehicles, but not including any operation named under "automobile repair, major" or any other similar use. Awning: A shelter supported entirely from the exterior wall of a building; a temporary or permanent nonloadbearing projection from an exterior wall of a building designed to provide shade or protection from elements, having a pitched surface which may not be used for any other purpose. A rooflike structure of fabric stretched over a rigid frame projecting from the elevation of a building designed to provide continuous overhead weather protection. 61 Created: 2025-01-10 08:29:38 [EST] (Supp. No. 52) Page 2 of 11 Basement: A story wholly or partly (at least 50 percent) measured from floor to ceiling, below the level of the ground on the street side of the building. A basement or cellar is not counted when measuring the height of a building. Bakery: A place for preparing, baking and selling all products on the premises where prepared. Block: A tract of land bounded by streets, or by a combination of streets and public parks, cemeteries, railroad rights-of-way, highways, streams, or corporate boundary lines. There may be more than one numbered block as shown on a plat falling within a single block as herein defined. Block face: A word used as a term of measurement. It shall mean the distance along a side of a street between the nearest two streets which intersect said street on the said side. Board: Shall mean the board of adjustment established in article 41 of this ordinance. Build: To erect, convert, enlarge, reconstruct, or alter a building or structure. Buildable width of a building site: The width of the building site left to be built upon after the required side yards are provided. Building: Any structure built for the support, shelter, or enclosure of persons, animals, chattels, or movable property of any kind. Building, detached: A building surrounded by yards or open space on the same building lot. Building height: See height. Building line: The rear line of a required front yard which is generally parallel to the street line forming the front lot line. Building lot: A single tract of land located within a single block which, (at time of filing for a building permit) is designed by its owner or developer as a tract to be used, developed, or built upon as a unit, under single ownership or control. It shall front upon a street or approved place. Therefore, a "building lot" may be subsequently subdivided into two or more "building lots", and a number of "building lots" may be cumulated into one "building lot", subject to the provisions of this ordinance and the subdivision ordinance. Building, mixed: A building used partly for residential use and partly for community facility and/or commercial use. A mixed building is a commercial use. Building official: The administrative official charged with responsibility for issuing permits and enforcing the zoning ordinance and building code. Building, principal: A building in which the principal use of the lot, on which it is located, is conducted. All residential uses, except bona fide servants quarters, are principal uses. Building, residential: A building which is arranged, designed, used, or intended to be used for residential occupancy by one or more families or lodgers. Canopy: A roofed structure constructed of metal, wood or any other solid material supported by the building or by support extending to the ground directly under the canopy [and] placed so as to extend outward from the building providing a protective shield from doors, windows, and other openings. Carport: A structure open on a minimum of three sides designed or used to shelter the owner's vehicle(s), not to exceed 24 feet on its longest dimension. Cellar: See basement. Certificate of occupancy or compliance: An official certificate issued by the city through the enforcing official which indicates conformance with or approved conditional waiver from the zoning regulations and authorizes legal use of the premises for which it is issued. 62 Created: 2025-01-10 08:29:38 [EST] (Supp. No. 52) Page 3 of 11 Charity house or transitional housing: Shall mean short or long-term temporary occupancy of a single family residential structure, uncompensated or de minimis fee, for person(s) that are sick, very poor, homeless or have special needs or disabled. This definition does not include assisted liv ing, group homes, half-way house or other type of temporary house licensed under state law or defined in the Code of Ordinances. City: Shall mean the City of Coppell, Texas. City council: The governing body of the City of Coppell, Texas. City manager: The chief city administrative officer. Clinic: The office of one or more medical doctors, dentists, optometrists, or similar members of the medical professions who may or may not have associated in the practice of their professions. Cleaning: A custom cleaning shop not exceeding 5,000 square feet of floor area. Clustering: A land development concept whereby the buildings on a site are grouped closely together but not attached to allow for communal open space and economies in development. Clustering permits variation in lot size, shape and orientation without an increase in the overall density of the development. Community club: Any club, (other than a private club), service club, sorority, fraternity, lodge or other private organization or club where alcoholic beverages are not served pursuant to a private club permit issued by the State of Texas. Concrete block: Any of the molded load-bearing or non-load-bearing concrete units normally 8" x 8" x 16". Convalescent home: Any structure used for or customarily occupied by persons recovering from illness or suffering from infirmities of age. College or university: An institution established for educational purposes and offering a curriculum similar to the public schools or an accredited college or university, but excluding trade and commercial schools. Convenience store: A small retail store, generally under 3,000 square feet, which typically sells groceries and retail sales of non-food items or prepared foods, hot and cold beverages and packaged beverages or a combination. The outside storage or display and sale in the open, outside the building of groceries, packaged beverages and consumer goods and drive-through or drive-up service is prohibited. Court: An open, unoccupied space, bounded on more than two sides by the walls of a building. An inner court is a court entirely surrounded by the exterior walls of a building. An outer court is a court having one side open to a street, alley, yard, or other permanent open space. Coverage: The percent of a lot or tract covered by the first floor or the largest floor of a building or structure whichever is larger, including all covered porches, patios, garages, accessory buildings, etc. Unsupported roof overhangs and other allowed architectural projections shall be excluded from coverage computation. Curb line: A line created by following the edge of the street or curb. Cumulative zoning: The successive addition of uses allowed in more restrictive zoning districts to lesser restrictive zoning districts. Custom personal service: A tailor, shoe repair, barber, beauty shop, health studio or travel consultant. Day nursery or day care center: An establishment where four or more children are left for care or training during the day or portion thereof. Density: The relationship of the total number of dwelling units to the area of the total site area commonly expressed as "dwelling units per acre." Depth of lot: The mean horizontal distance between the front and rear lot lines. See illustration # 12. 63 Created: 2025-01-10 08:29:38 [EST] (Supp. No. 52) Page 4 of 11 Development, or to develop: The construction of a new building or any structure on a building lot, the relocation of an existing building on another building lot, or the use of open land for a new use. To "develop" is to create a development. Distribution Center: an established location that stores goods purchased by the operator for resale, that does engage in storing goods for hire, and where goods are not sold to retail customers. District: A zoning district which is a part of the city wherein regulation of this Ordinance is uniform. Dwelling, one-family: A dwelling having accommodations for and occupied by not more than one family, or by one family and not more than four boarders and lodgers. Dwelling, two-family: A dwelling having separate accommodations for and occupied by not more than two families, or by two families and not more than four boarders and lodgers. (Two boarders or lodgers to each unit). Dwelling, multiple-family: Any building or portion thereof, which is designed, built, rented, leased, or let to be occupied as three or more dwelling units or apartments or which is occupied as a home or residence of three or more families. Dwelling unit: A building or portion of a building which is arranged, occupied, or intended to be occupied as living quarters of a family and including facilities for food preparation and sleeping. Family: Consists of one or more persons, each related to the other by blood, marriage, or adoption; or a group of not more than four persons (excluding servants) who are living together in a dwelling unit. Farm: An area of five acres or more which is used for growing of usual farm products, vegetables, fruits, trees and grain and for the raising thereon of the usual farm poultry and farm animals such as horses, cattle and sheep and including the necessary accessory uses for raising, treating and storing products raised on the premises, but not including the commercial feeding of offal or garbage to swine or other animals and not including any type of agriculture or husbandry specifically prohibited by ordinan ce or law. Floor area: The total square feet of floor space within the outside dimensions of a building including each floor level, but excluding cellars, carports, or garages. Floor area ratio (FAR): An indicated ratio between the number of square feet of total floor area in the main building(s) on a lot and the total square footage of land in the lot; it is the number resulting from dividing the main building floor area by the lot area. (See appendix illustration No. 15) Fulfillment Center: an established location operated to receive orders from retail customers, placed primarily over the Internet through the use of websites, for purchase of goods held in inventory at that location that are shipped or delivered from the center directly to the place designated by purchaser. A fulfillment center does not store goods for hire. It keeps or retains goods for sale to retail customers in the regular course of business. It is not a warehouse or a distribution center. Garage, private: An accessory building designed or used for the storage of motor vehicles owned and used by the occupants of the building to which it is necessary. Garage, public: A building or portion thereof, other than a private or storage garage, designed or used for storing motor driven vehicles. Garden center: The growing, displaying, and/or wholesale or retail sale or handling of plants, shrubs, trees, soils and related materials conducted within or without an enclosed building. Gasoline station or filling station: Any building or premises used for the dispensing, sale, or offering for sale at retail of any automobile fuels or oils. If the dispensing, sale or offering for sale is incidental to a public garage, the premises shall be classified as a public garage. Gross acreage: The total size of the property including floodplains, easements, and other non -buildable areas located on the property. 64 Created: 2025-01-10 08:29:38 [EST] (Supp. No. 52) Page 5 of 11 Health service: A charitable or government operated facility offering to the public medical examinations, diagnosis and limited treatment not for profit. Heavy load vehicle: A self-propelled vehicle having a load capacity greater than one and one-half tons, such as large recreation vehicles, tractor-trailers, buses, and other similar vehicles; the term "truck" shall be construed to mean "heavy load vehicle" unless specifically stated otherwise. Height: The vertical distance of a building measured from the average established grade at the street line or from the average natural front yard ground level, whichever is higher, to (1) the highest point of the roof's surface if a flat surface, (2) to the deck line of mansard roofs or, (3) to the mean height level between eaves and ridge for hip and gable roofs and, in any event, excluding chimneys, cooling towers, elevator bulk heads, penthouses, tanks, water towers, radio towers, ornamental cupolas, domes or spires, and parapet walls not exceeding ten feet in height. If the street grade has not been officially established, the average front yard grade shall be used for a base level. Home occupation:A business, occupation, or profession conducted within a residential dwelling unit by the resident thereof, and which shall have the following characteristics: 1. The activity shall employ only members of the immediate family of the resident of the dwelling unit; 2. There shall be no external evidence of the occupation detectable at any lot line, said evidence to include advertising signs or displays, smoke, dust, noise, fumes, glare, vibration, electrical disturbance, storage of materials or equipment, or traffic or parking of vehicles in a manner evidencing the conduct of a business; 3. Said home occupation shall not have a separate entrance for the business and shall not include appointed visits by the general public. Any business, occupation or profession conducted within a dwelling unit and which does not meet the aforesaid characteristics shall be construed to be a commercial activity and shall therefore be cause for the city to order a cease to all such activity within said dwelling unit. Hospital: A legally authorized institution in which there are complete facilities for diagnosis, treatment, surgery, laboratory, x-ray, and the prolonged care of bed patients. Clinics may have some but not all of these facilities. Hotel: An establishment offering lodging to the traveling public for compensation. Access to the majority of the guest rooms is through a common entrance and lobby. The establishment furnishes customary hotel services and may contain a restaurant, club, lounge, banquet hall and/ or meeting rooms. Microwave and small (under the counter) refrigerator is permitted in the rooms, however other kitchen facilities, such as cooktop, oven (except microwave) and full size refrigerator would not be permitted. A hotel is a non- residential use. Household appliance service and repair: An enclosed facility for repair of household and home equipment, including appliances, lawnmowers, power tools, radios, TV and similar items. Junk or salvage yard: A lot upon which waste or scrap materials are bought, sold, exchanged, stored, packed, disassembled, or handled, including but not limited to scrap iron and other metals, paper, rags, rubber tires and bottles. A "junk yard" includes an automobile wrecking yard and automobile parts yard. A "junk yard" does not include such uses conducted entirely within an enclosed building. Landscaping contractors yard: A lot upon which landscaping items such as trees, plants and shrubs may be stored for future sale. Loading space: A space within the main building or on the same lot therewith, providing for the standing, loading or unloading of trucks, and having minimum dimensions of 12 by 60 feet for industrial and warehouse uses and 12 by 30 feet for commercial, retail and institutional uses with a vertical clearance of at least 14 feet, together with access and maneuvering areas provided on the same building lot as the principal use for which the loading space is intended. 65 Created: 2025-01-10 08:29:38 [EST] (Supp. No. 52) Page 6 of 11 Lodging house: The rental of any single-family residence or its residential structure, mobile home, manufactured house or a portion of a single-family residence or residential structure including but not limited to pools, garages, and outdoor accessory structures for a period of less than 30 days. This term includes but not limited to: 1. Bed and breakfast; 2. Boarding home or hostel; 3. Vacation home; 4. Short-term rentals (STR); or 5. Corporate housing. The term does not include: 1. A unit that is used for a nonresidential purpose, including an educational, retail, restaurant, banquet space, or event center purpose or other commercial purposes another similar use; 2. A hotel/residence hotel; 3. A place for residence or use as a licensed health care or assisted living facility licensed by the State; or 4. Parsonage on the premise of a church, mosque or synagogue. 5. A commercial storage facility. Lot area: The area of a horizontal plane intercepted by the vertical projections of the front, side, and rear lot lines of a building lot. (See appendix illustration No. 12) Lot area per dwelling unit: The lot area required for each dwelling unit located on a building lot. Lot, corner: A building lot situated at the intersection of two streets, the interior angle of such intersection not to exceed 135 degrees. Lot depth: The mean horizontal distance between the front lot line and the rear lot line of a building lot measured at the respective mid points of the front lot line and rear lot line within the lot boundary. (See Appendix Illustration No. 12) Lot line: A boundary of a building lot. Lot line, front: That boundary of a building lot which is the line of an existing or dedicated street. Upon corner lots either street line may be selected as a front lot line providing a front and rear yard are provided adjacent and opposite, respectively, to the front lot line. (See appendix illustration No. 11) Lot line, side: That boundary of a building lot which is not a front lot line or a rear lot line. Lot line, rear: That boundary of a building lot which is most distant from and is, or is most nearly, parallel to the front lot line. Lot of record: An area of land designated as a lot on a plat of a subdivision recorded, pursuant to statutes of the State of Texas, with the county clerk of Dallas County, Texas or an area of land held in single ownership described by metes and bounds upon a deed record ed of registered with the county clerk. Lot, reverse corner: A corner lot, rear lot line of the street which abuts the side lot line of the lot to its rear. Lot, through: A "double frontage" lot is a building lot not a corner lot, both the front and rear lot lines which adjoin street lines. On a "through lot" both street lines shall be deemed front lot line. Lot width: The minimum distance between the side lot lines of a building lot measured along a straight line at the rear of the required front yard and parallel to the street line or a line tangent thereto. (See appendix illustration No. 11) 66 Created: 2025-01-10 08:29:38 [EST] (Supp. No. 52) Page 7 of 11 Manufactured home: A factory-built dwelling unit, attached or detached, which is wholly or partially constructed away from its building lot and moved to a building lot where it is affixed or situated as a permanent building. A manufactured home is a residential use. A manufactured home shall not be construed to be a mobile home. Masonry: Brick, stone, concrete or other similar materials but excluding stucco and "concrete blocks". The masonry requirement shall be computed for the area from the foundation to the top plate of the first floor and from plate to plate for each floor above the first. Mini-warehouse (convenience storage): A building or group of buildings containing one or more individual compartmentalized storage units for inside storage of customer's goods or wares, where no unit exceeds 500 square feet in floor area. No outside storage, storage of explosives, flammable materials, materials emitting noxious odors or other similar activities shall be allowed. Caretaker's quarters are required as an accessory use. Mobile home: A vehicle used for living or sleeping purposes and standing on wheels or on rigid supports, but which when properly equipped and situated can be towed behind a motor vehicle. A trailer coach is a mobile home. Mobile home park: Any premises on which two or more mobile homes are parked or situated and used for living or sleeping purposes, or any premises used or held out for the purpose of supplying to the public a parking space for two or more mobile homes whether such vehicles stand on wheels or on rigid supports. A trailer park is a mobile home park. Modular home: A factory-built dwelling unit, attached or detached, which is wholly or partially constructed away from its building lot and moved to a building lot where it is affixed or situated as a permanent building. A modular home is a residential use. A mobile home shall not be construed to be a modular home. Motorcycle: A usually two-wheeled self-propelled vehicle having one or two saddles or seats, and may have a side car attached. For purposes of this ordinance, motor bikes, motorscooters, mopeds, and similar vehicles are classified as motorcycles. Motor freight terminal: A building or area in which freight brought by motor truck is assembled and/or stored for shipping in interstate and intrastate commerce by motor truck. A motor freight terminal is a truck terminal. Net acreage: The total buildable area of a lot. Net acreage shall not include floodplain area, public rights -of- way, or other areas where buildings can not be located. Nonconforming use: Any building or land lawfully occupied by a use at the time of the adoption of this ordinance or amendments thereto, not permitted by the use regulations, lot requirements or other regulations of this ordinance of the district in which it is attained. Noxious matter: A material which is capable of causing injury to living organisms by chemical reaction or is capable of causing detrimental effects upon the physical or economic well -being or comfort of humans. Occupancy: The use or intended use of the land or buildings by proprietors or tenants. Open space: That part of a building lot, including courts or yards, which: 1. Is open and unobstructed from its lowest level to the sky, and 2. Is accessible to all residents upon a building lot, and 3. Is not part of the roof of that portion of the building containing dwelling units. Open storage: The storage of any equipment, machines, commodities, raw, semi-finished materials, and building materials, not accessory to a residential use which is visible from any point on the building lot line when viewed from ground level to six feet above ground level. 67 Created: 2025-01-10 08:29:38 [EST] (Supp. No. 52) Page 8 of 11 Outside storage and display—Retail stores and shops shall mean the display or offer of all types of consumer goods for sale in the open, outside a building footprint and under a roofline canopy of such building footprint, of groceries, packaged beverages, consumer goods, new or used automobiles, heavy mach inery, building materials, used appliances, furniture, vending machines or salvage materials typically not in a fixed position and capable of rearrangement, designed and used for the purposes of advertisin g or identifying a business, product, or service. For the purpose of this section, the definition of canopy does include any such structure extending outside the building footprint into an area used for motor vehicle traffic. (See Fig. 42 -1 for graphic explanation of this definition). Parking space: An enclosed or unenclosed all-weather surfaced area not on a public street or alley, together with an all-weather surfaced driveway connecting the area with a street or alley permitting free ingress and egress without encroachment on the street or alley. Any parking adjacent to a public street wherein the maneuvering is done on the public street shall not be classified as off-street parking in computing the parking area requirements for any use. Patio home: A single-family detached dwelling unit on an individually platted lot. The structure is situated on or near one side lot line to facilitate use of the remaining side yard on the opposite side of the building. Planning director: The administrative official responsible for the administration of this ordinance during the platting and/or rezoning process. Planning and zoning commission: The agency appointed by the city council as an advisory body to it and which is authorized to recommend changes in the zoning and review of subdivision plats. Plat: A plan of a subdivision of land creating building lots or tracts and showing all essential dimensions and other information essential to comply with the subdivision standards of the City of Coppell subject to review by the planning and zoning commission and approval by the city. Reference to a plat in the ordinance means an official plat of record which has been reviewed by the planning and zoning commission and approved by the city and filed in the plat records of Dallas County. 68 Created: 2025-01-10 08:29:38 [EST] (Supp. No. 52) Page 9 of 11 Premises: Land together with any buildings or structures occupying it. Private club: a club where alcoholic beverages belonging to members of the club are stored, possessed, mixed on the club premises and served for on-premises consumption to members of the club, their families and guests pursuant to a private club permit issued by the State of Texas. Public park: Any publicly owned park, playground, beach, parkway, greenbelt, or roadway within the jurisdiction and control of the city. Recreation area: A privately owned park, playground, or open space maintained by a community club, property-owners association, or similar organization. Residence hotel: A multi-dwelling, extended stay lodging facility consisting of efficiency units or suites with a complete kitchen (which are defined as containing a stove top and oven and full size refrigerator) suitable for long - term occupancy. Customary hotel services such as linens, maid service and telephone are provided. Residential districts:Includes the following districts: SF-ED, SF-18, SF-12, SF-9, SF-7, SF-O, 2F-9, TH-1, TH-2, MF-1, MF-2 and MH. Residential structure: Any single-family, multi-family, or apartment building, condominium project, town home, zero lot line home as defined by the Federal Department of Housing and Urban Development. Rest home or nursing home: A private facility for the care of children or the aged or infirm or a place of rest for those suffering bodily disorders. Such homes do not contain facilities for surgical care or the treatment of disease or injury. Restaurant: A commercial establishment primarily where food and beverages are prepared, served and consumed within the principal building, on the premises or for take out. Retail stores and shops: Facilities which offer all types of consumer goods for sale, but excluding the display and sale in the open, outside a building, of new or used automobiles, heavy machinery, building materials, used appliances, furniture or salvage materials. Retail store(s), shop(s) and Retail Center: established locations that display and sell goods in-person to consumers, but excluding the display and sale in the open, outside a building, of new or used automobiles, heavy machinery, building materials, used appliances, furniture or salvage materials. School: A school under the sponsorship of a public or religious agency having a curriculum generally equivalent to public elementary or secondary schools, but not including private or trade or commercial schools. Screened from view from an adjacent public street: A permanent structure of sufficient height to screen material and which in no event extends higher than the exterior wall of the primary building and constructed of the same or similar color and material as the primary building. Screening device: A "screening device" shall consist of a barrier of stone, brick, uniformly colored wood, or other permanent material of equal character, density, and acceptable design, at least six feet in height. Servant's quarters: An accessory building or portion of a main residential building located on the same lot as the principal residential building, occupied only by such persons and their families as are employed full time by the occupants of the principal residence. Showroom: a room or area in excess of one thousand square feet where durable goods are displayed for retail sales to consumers. Story: That part of a building between the surface of a floor and the ceiling immediately above. A standard story is 11 feet, six inches. Street: A public right-of-way which affords a primary means of access to abutting property. A driveway or alley which serves only to give secondary vehicular access to a building lot or to an accessory parking or loading 69 Created: 2025-01-10 08:29:38 [EST] (Supp. No. 52) Page 10 of 11 facility, or to allow vehicles to take or discharge passengers at the entrance to a building shall not be considered a street. Street, private: A street which has no publicly dedicated right-of-way. Street line: A "street line" is the right-of-way of a street. Stucco: A continuous plaster or mortar exterior veneer, finished by hand troweling over wire lath. Technology equipment facility: A structure that is occupied by telecommunications, computer and similar high technology equipment that provide electronic data switching, transmission, routing or other telecommunication functions between computers. Ancillary uses may include an office for personnel, conference room, back-up power generators, and fuel storage, which shall only be permitted as an accessory use to the back - up power generators. Tennis or swim club: A private recreational club with restricted membership, usually of less area than a country club, but including a club house and swimming pool, tennis courts and similar recreational facilities, none of which are available to the general public. Top plate line: That point at which the ceiling plane of the upper most story intersects the vertical wall plane. Townhouse: attached single-family dwelling units on individually platted lots. Toxic materials: Those materials which are capable of causing injury to living organisms by chemical means when present in relatively small amounts. Use: The purpose or activity for which the land, or building thereon, is designed, arranged, or intended, or for which it is occupied or ;maintained, and shall include any manner of such activity with respect to the standards of this ordinance. Use, principal: The main use of land or buildings as distinguished from a subordinate or accessory use. Video amusement: Arcade and other commercial indoor coin operated amusement facility. Visual screen: A wall, not of living plant material, permanently affixed to the ground in which the area of all openings and cracks in each square foot of wall is of sufficient height so that the objects being screened are not visible from any point on the lot line when viewed from any height between ground level and six feet above ground level. No wall shall exceed eight feet in height. Warehouse/distribution: A use devoted to storage, warehousing and distribution of goods, merchandise, supplies and equipment. Accessory uses not considered to be part of storage and warehousing areas may include, but are not limited to, retail and wholesale sales areas, offices, sales offices, research and development areas and display areas for products sold and distributed from the storage and warehousing areas. Parking for all herein - defined accessory uses shall be provided, on a gross square-foot basis, in accordance with the Section 12-31-6 of the Coppell Zoning Ordinance. Warehouse: an established location engaged in storing goods for hire for multiple parties that does not sell goods in the regular course of business and that does not store goods that the operator has purchased for resale. Wind energy system/wind turbine: A wind energy conservation system consisting of a wind turbine, a tower, mounting components and associated control or conversion electronics, or any combination thereof. Yard: An open space on the same building lot with a building, unoccupied and unobstructed by any portion of a structure from the ground upward, except as otherwise provided. In measuring a yard for the purpose of determining the width of a side yard, the depth of a rear yard, and the depth of a front yard, the minimum horizontal distance between the building site and the lot line shall be used. A "yard" extends along a lot line and at right angles to such lot line to a depth or width specified in the yard r egulations of the zoning district in which such building is located. (See appendix illustration No. 13) 70 Created: 2025-01-10 08:29:38 [EST] (Supp. No. 52) Page 11 of 11 Yard, front: A yard extending along the whole length of the front lot line between the side lot liens, and being the minimum horizontal distance between the street line and the main building or any projections thereof other than steps, planter box, unenclosed porches, and driveways. (See appendix illustration No. 13) Yard, rear: A yard extending across the rear of a lot between the side lot lines and being the minimum horizontal distance between the rear lot line and the rear of the principal building or any projections thereof other than steps, unenclosed balconies, unenclosed porches, or driveways. Yard, side: An open unoccupied space on the same lot with the building, situated between the building and the side property line of the lot, and extending through to the street or the front property line. (See appendix illustration No. 13) Zoning district map: The map or maps incorporated into this ordinance as a part thereof by reference thereto. (Ord. No. 91500; Ord. No. 91500-A-105; Ord. No. 91500-A-331, § 1, 8-13-02; Ord. No. 91500-A-334, § 1, 8-13-02; Ord. No. 91500-A-377, § 1, 5-11-04; Ord. No. 91500-A-434, § 4, 6-13-06; Ord. No. 91500-A-445, § 3, 12-12-06; Ord. No. 91500-A-473, § 2, 8-14-07; Ord. No. 91500-A-544, § 2, 3-23-10; Ord. No. 91500-A-551, § 2, 5-11-10; Ord. No. 2016-1433, § 3, 4-12-16; Ord. No. 91500-A-790, § 6, 5-9-23; Ord. No. 91500-A-814, § 3, 4-9-24) 71