Loading...
Bellacere Addn-CS080722(8/3112009) DiWanna Baskins -Bellacere Addition Comments From: DiWanna Baskins To: michaduffy~charter.net Date: 7/22/2008 7:43 AM Subject: Bellacere Addition Comments Attachments: Bellacere Addn-CS080307.tif; Bellacere Addn-CS080221.tif Micha, I sent the last two review comments, one is dated August 15, 2007 and the latest is March 7, 2008. The comments dated Aug 15th include Finish Floor comments. I hope this helps. DiWanna Baskins Graduate Engineer Engineering Department (P)972-304-3562 (F)972-304-3570 Page 1 (8/3112009) DiWanna Baskins -Bellacere Addn-CS080307.tif T H E C I T Y O F X A ~ •- ~ ~ March 7, 2008 s Micha P. Duffy, P.E. Hamilton Duffy, PC b01 W. Harwood Rd Hurst, TX 7b454 13E; Bellacere Additions Construction Plan Review Comments The City of Coppell has reviewed the referenced plans and has the following comments to offer: Plat- The 24 ft. by 20 ft. drainage easement is na longer needed. The 14 ft. drainage easement should be extended to the west property line. 2. Show the limits of the inset. Grading Plan 3. Is the concrete flume still needed on the northwest corner of the property? 4. It appears the concrete Swale has been removed. It should be removed from the plan and profile. Paving Plan - 5, The paving notes shotiv a 7" fire lane and the legend shows a 6". If you are requesting a variance an the sub-grade, you must submit a Ietter for approval with the geotechnical report. Storm Drain Plan and Profile - b, Show the water crossing at the junction box on the storm drain profile. 7. Show proposed water line and sanitary sewer on storm drain plan. Utility Plan and Profile - 8. Show storm drain on utility plan. 9. Lighten the tree layer and clean up the utility plan to make it easier to read. 10. Show the water crossing an the profile. There may be additional comments throughout the plans that need attention as well. Please make the necessary changes and submit these marked-up plans and two sets of revised plans to the City for review, If you have any questions, please contact this office at your convenience. Sincerely, Mi h arza, E.I.T Graduate Engineer Office Phone: (972) 304-3b79 Fax: (972) 304-3570 E-mail mgarza@ci.coppell.tx.us Page 1 255 PARKWAY * P.O.BOX 9478 * CpPPELL 7X 75019 * TEL 972/462 OD22 * FAX 9721304 3673 (8/3112009) DiWanna Baskins -Bellacere Addn-CS080221.tif ~2-~1-~~ ~PG~ ~~7 kC'~D C O N S U L T I N O d411 t OMf10ME1RAL - PIANIiRS - CONSIAUCTIdV IIYIMiEAS ear w wNwooo sao - ~urtsr, roue rana~-~~a~ PM{'!!E (61~ ice-o~aa rroc Re,~ m+-a+aa $241 Mid-Cities Blvd Suite 100 North Richland Hills, Texas 751$0-4159 Phone: 817-26$-040$ Fax: 817-284-8408 Email: michaduff charter.nefi _... ~....:c::: f ~ `\., ~' fi'r`-' ~~ .9 In j ~ :~f ~ ~~'`1 DATE February 21, 200$ J4B N0.124-001 ATTN: Ken Griffin, PF RE Bellacere Addition Coppell, Texas From: Micha P. Dufify, PE J To Cit of Co ell - En ineerin 255 Parkwa Co e!I TX 75~19- 912.4G2.0022 _ Qty Date Sheet No. Descnpfion 2 02-18-2008 See Cover sheet for index X27 sets of preliminary engineering for review REMARKS Ken -Please accept these plans as preliminary engineering plans submittal far the Bellacere Addition Please contact this office if you have any questions or need additional information. Thanks, COPY TO fife, .. SIGNS Page 1 (8/3112009) DiWanna Baskins -Bellacere Addn-CS080221.tif T H E C{ T Y O F '~ r ~ F q x A ti $ s A~lgust 1 s, Zaa~ ~. Micha P. Duffy, P.E. ~' 1~M~: Hamilton Duffy, PC 601 w. Harwood Rd '~y Hurst, T~ x'6054 ., ~;; Bellacere Additions Construction Plan Review Comallent;~ ' of Co ell has reviewed the referenced plans and has the following comments to offer: ' The City pp ~ ,: Pl. 1. Label how the Right-of =~Vay is being dedicated ~By this Plat). 0 ~. ~. Is this a final plat`. ~(~~ ~. Label the property line correctly on all sheets. ply 1)rain~. e Area 1'~a - 4. Review drainage areas from the adjacent properties. Shadydale Acres is currently picking up Borne of the drainage from this site. ~~ ~- 4, ~~ ~~~~ c~~sv ~ ~~2 . 5. Provide storm sewer profiles with calculations to verify capacity of the existing and proposed system. D4C. 6. Shod calculations for swage at tine el~d of the fire large to the north. ~ .~ Gradin Plan-- 7. Is this enough grading information to build the project? Provide spot elevations at re~~r of prope~-ry, between property a~~d ~~long the ea.~t side of the property. Da not allow runoff onto alley; Convey runoff to the drop inlet to the north. S. Finished floor must be a minimum of l.' above paving grade. oK Prole - ~~ Plan and 9, Future edge of pavement is approximatel 10' from the proposed R,~.W. See plans for Sand Lake Rd. Teague Nall and Perl~ns). he grade at this .point needs to be b~' to 10" Y future flow line of Sal~cly Lake Rd. 1'~t~ ~ ~ ~aV"I'T~C~ ~~~~ ~,~" higher than l0.5howthe future grades of Sandy Lake Rd. on the profile sheet. ~~N (~ ~~~ v~ Pavin Pg lan - i l . Provide a 30' radius on the fire lane entrance per itre lane standard detail 2310. p~ Page 2 255 PARKWAY * P.U.BDX 9478 * COPpELL TX 75019 'k TEL g7~21e152 OD22 'k FAX 972/3U4 3673 (8/3112009) DiWanna Baskins - Bellacere Addn-CS080221.tif 12. The paving notes show a 7" fire lane and the legend shows 6". which one will be used? If you are requesting a variance on the sub-grade, you must submit a letter for approval with the geotechnical report. ~u WU~- ~~ U~~ . ~ t(~z.~A~C.~' 13. Any necessary lane closures will be from gam to 3:30 pm only. ~~ Utili Plan and Profile 14. Verify the size of the existing sanitary sewer. 15. Sanitary sewer manhole elevations notes do not match the profiles. w(~~ ~w u~2~~T' 16. The storm sewer is running through the sanitary sewer manhole. -~ u~~~,u. ~~~ 17. Show the water crossing on the profile. --~~ 18. Move the fire hydrant north towards lot 4 and add another one at the entrance of the firelane, c7i~. There maybe additional comments throughout the plans that need attention as well. Please make the necessary changes and submit these marked-up plans and two sets of revised plans to the City for review. If you have any questions, please contact this office at your convenience. Sincerely, Michael Garza, E.I.T Graduate Engineer Office Phone: (972) 344-3679 Fax: (9?2) 344-3574 E-mail mgarza@ci.coppell.tx.us Page 3