Loading...
Denton Creek/Sandy Lake-CS090701(9/3/2009) DiWanna Baskins - RE: Akula Home Project, Denton Creek at Sandy Lake From: "ROBERT SCHNEEBERG" <robert.schneeberg@gs-engineers.com> To: "'DiWanna Baskins"' <dbaskins@ci.coppell.tx.us> CC: "'Daniel St. Claire"' <ghomes@att.net> Date: 712/20091:35 PM Subject: RE: Akula Home Project, Denton Creek at Sandy Lake Will that suffice to get them started? I will have final sets delivered with the plat included if everything looks ok. Robert schneeberg Gonzalez &schneeberg, Engineers & Surveyors. Inc. 660 North Central Expressway, Suite 250 Plano, Texas 75074 Phone:972-516-8855 Fax:972-516-8901 -----Original Message----- From: DiWanna Baskins [mailto:dbaskins@ci.coppell.tx.us] Sent: Wednesday, July 01, 20091:57 PM To: ROBERT SCHNEEBERG Cc: 'Daniel St. Claire'; 'Raj' Subject: RE: Akula Home Project, Denton Creek at Sandy Lake As I review this pdf... Let me remind you that a copy of the plat will need to be submitted with the early grading plan set before the early grading permit can be approved. »> "ROBERT SCHNEEBERG" <robert.schneeberg@gs-engineers.com> 711/200911:07 AM »> DiWanna, Try this. The owner and contractor asked me to revise the grading plan to keep the retaining wall under 4 feet. Additionally, they told me they wanted to construct a stacked stone and mortar gravity wall and that they would provide details with the building plans. Please take a look and let me know if we are ready to print final sets for the grading permit. Thanks, Robert schneeberg Gonzalez &schneeberg, Engineers & Surveyors. Inc. 660 North Central Expressway, Suite 250 Plano, Texas 75074 Phone:972-516-8855 Fax:972-516-8901 -----Original Message----- From: DiWanna Baskins [mailto:dbaskins@ci.coppell.tx.us] Sent: Monday, June 29, 200910:13 AM To: Robert.schneeberg@gs-engineers.com Subject: Akula Home Project, Denton Creek at Sandy Lake Page I prematurely sent the last a-mail. (9/3/2009) DiWanna Baskins - RE: Akula Home Project, Denton Creek at Sandy Lake I do have a couple of concerns regarding the submital. First is the proposed wall. We will need engineering plans forthe wall. When do you plan on building the wall? Also, some of the bold elevations are shown higher than the FF. Sincerely, DiWanna Baskins Graduate Engineer Engineering Department (P)972-304-3562 (F)972-304-3570 Page 2 ,~~, ,~~ x 1 , I \ . ~ I L \ \\ ~ \ \ I ~ . I ~ ~ ~00°1242 W \ = _- \ -M 1 t I, TP=449.80 - \' ,,,, TP-450.20 \ 135• \ s' •, ~ ; I DENTON CREEK LANG COMPANY- W=4 6.50 BW=446.50 \ 1 1 ' 1 I °_,: 1316 SANDY LAKE RD. __--A4:i-- ---- I ~ I \ _. -- _ -_. --.. _. - V: 2003133, R. ~f5b9 „...- - - _. __ -- ~; ~, - I _ .. _ _ .. l .. ,- _ -_.~ is ;! .. ,, Ay __ 0 ,,. .-._~ .y ~ .. "" ~° ..;..,.. .. ~,. i _` _ .._ 1 0 I 446.,,, - _ \ _ \ s- - - - - 1 ~ r ~,_ \ 446 _ 7P=450.70 TP=450.00 _\ 8 ` ~ .P 2~ 5q.fl 449 _ _ ._ .496.50 _ \ ~ ~ ~ - 20 0 20 40 , _ `. ~ ~ \,~ bps-- ~ - _, , ~ 1 I 145 >•es _ ___ _ - ___ -- --- _--- \ ^`. ~.;;_ Scale in Feet ` I ^ ' ~ LO ;,BLOCK A ,--- ---- - --_ ...__..___-_._c5a' _ -- - _ \,,,, :, •a~e• .~ . 1 ~ 1 a~ ' ~` NTON CREEK a I _ ~ NE.au _ ~.. ~ 30:,, `U •. , . ! 1 ~ , ANDY LAKE ADDITO wail ~, -- _ \ ~ ~ .. ~~, '"LEGEND ~.\ _ _- ~, - '. \~ .. ' ' ~ I ~.-... \ ~ {' t .:a' _ `~ \~ ~ ,°, ' :. \ TC=563.25 TOP OF CURB ~ \•z ' G56275 TOP OF GUTTER I qn ~ ~. ', I II O If80 E. SANDY LAKE ROAD \ - ~. ~ ~ TWO-STORY ` ~~ I ~ ~ BRICK BUILDING ~! - \ ~ •'' ~ \ TP=565.00 TOP OF PAVEMENT r ~ _, I RESIDENCE I i i ~ -. .. ,.. , ' *"A' ~ , BW=565.00 BOTTOM OF WALL ` 449 1 ~ a.~ FF_45L70' _. ~ \~_ \~~ "~ .4 j I ~ °, E. ~ F FLOW LINE ' I ~ 448 `~ ~ \\ \~ • ~, ~ 564 PROPOSED CONTOUR LINE •„, • , 1 '~ r rr,:y I ;\ \ 1 ~~+ WATER METER -_____ __ 1 1 443" ~ S 53°342j" E 1' \\ ~ ~~ .,, 1 ~ m~~ WATER VALVE 1 G I '' 7' \ r~~ tr LIGHT STANDARD 1. 60.36, 8.9 - _ ._ T - _ - _ I e ~ _ba~ \ 1 I \ \\ r ' ` \~ • \ ', ~ TRANSFORMER 1 ` 1 4 6 ', ~ ''~ E . / \' \ r ~ ~~ FIR HYDRANT ~ s~~, , ~ l~ 6` I - - - - N 50 OT 03" E _ _ 180.15' _ _ 451 ,;, ~ ~ ~\\ \\ ; , `II ,., E o. , ~ 1 '{ I \ 451 N , 1 i ~ \ \~ ~J ~ METAL SIGN I ~ ~ ~ I I '+ \ \\ \\~ •`~pp , ~~ SANITARY SEWER MANHOLE r , 1m. r, II 445 1 1 ~ 452 ~ 1 + ~ ~ ,- __. g - FENCE q I l \- , ~~ i \ \~ I 1 ~ I ~ /II 1 I \ ~ .450 i~ '\\ \~ + ~ier TELEPHONE MANHOLE 0„ WptER 11 ,( 1 I \\ ~ 0' ~ I ~ \ '\\~ • ~' ny .. STORM MANHOLE °, W ~ / 11 ' 11 `, a~ ~P soy I ~ . W ~ 1 ; \ , ; '/ ., \.. ~ ~ i ~ _, ,~ , , ,~ 'I t0 I II ~ I F~~NF ~ ~ - - - - -~ - -~ ~ \ 1 ' /l /l - ~ ~~ _. \~~, ,.~f\ .. r + i, G 4M.64 ' ~. i i i I ~ 6a _ , ' .._,--- -' ~ / „.. ' 1 o _ 1 '. 1 y - , _ i ,, a,. _ , 11 __ ; r ;; ~•, ~ I a . ~ rr,, ~ / ~, E v ~ 1 \ Imo, . ' ~' d / \ \ ' t ! / I n-- l/ ~ 1 / \ _ ~ - / i 4`°,~: 11 ~ ' .~/ // X36' \ \ ` I ~ ., ~ ~ ~., . ~ < I '~_ ~: ,~ , _ .; 1 o~ 5s I, 1 1 ~ `, ~ ~ ~ ~ ~ \ _ I ,, , ~.,,. ~ \ 36,922 sq.ft. -- -- ,!~ ;~ V `~ / .aA , c h ~ I y I 0.8476 acres v, /, ~, i 1 5 1 m - 11 1 1 _~ f ~, / ~ I+ ~ ~ 11 ', 1 ~ 1 1 i LOT 2, BLOCK A I ;/t . 1 / / ~ " ~ ' t ', ~ ! I DENTON CREEK ~ i ~ / ~ : ~', i ', llt.~~~`- I 1 11 I SANDY LAKE ADDITION f ,~ ~ NOTE, I ~ i ~ ,, /~~ ~ I I ;,~ - - - - - - - - -,` _,, f ; 1 _, No work ossocfOted with the approved CLOMR /s proposed o i vR r ~ ~ Y \ J ' / I ! / , ~' of this t(me. That portion of the project is being delayed 1 '~ `'~ ~~ ', 11 j/ ',' ~ \ ~ _ I I I ~ ~9 until the commercial portion of the project Is cons)ructed In 1 f , ~~1 - ~ ~ 1' \ ~~-~ d~,° ,~ r I I I ~ry a subsequent phase. _. ~' ... S 50.07'03 327,9 ' 111 ~ - - ~/ 1 I x ~ \ HENRY H• TA 7E ~- ~ ~ 'R `, \ 1200 SANDY LAKE RD. RODRaoUND j ' ' / 1h 1 ' V. 84098, P. 0782 ~ ~ v. e4o9a P. o7e5 ~ 6 *>k Y *# µ ~~ ~. _ D.R.D.~.T.__ ISSUED FOR GRADING ONL r 't 4t ~ '~ r, \ T ' " -445- - _..- \ .. ~ / ° ~ r 1 , i cc,,~a IXtIVE ~.~ / ~ & 5C I ' - ~~ ~~ ,pTION YO E ~, ;/ ~y~ti5 33T "gel zw iEOF.rF t ~~~, + 1 N \ r ,P AOBEAT, W. SCNN~ERG ~ n 1 ~ ~~` 'h ~~`''`•TrTgTE~'•'\Z~ i ~ ~ SS . 1 ~ \ / 6 /ONAL `o" I ' `rgs / ~ '~ 1 ~r 1 ~ NEW HOUSE ~ THE SEAL APPEARING ON THIS DOCUMENT WAS ~} + ' ' ~~ 1 V _ i ~ ~ ? / AUTHORIZED BY R09ERT W. SCHN®ERG, P.E 65352 ON " ~ ~ 06/26/2009. ALTERATION CF A SEALED DOCUMENT ~. ~:~ ~ ~C~ \~, ~ WITHOUT PROPER NOI1FlCAl10N TO THE RESPONSIBLE -~ "'.V . ~'1 ~ ENGINEER IS AN OFFENSE UNDER THE TEXAS ~•~ ° ~ ENGINEERING PRACTICE ACT. ,4 1 ~g .- ~ 1 w vARrEs ~ ~~ a MONOLITHIC CURB Wl7H 6" / -'~ a OPENING EVERY 70 FEET 1 1 - - a C2 ' ~ 3 ~- 70 PERMIT DRAINAGE. LESS THAN 4' 20 I Gonzalez & Schneeberg 880 K Central Expressway STACKED STONE AND MORTAR GRAVITY Suite 250, Plano, Tex 76074 5 RETAlNfNG WALL WITH DRAINS OR OWNER 817 IhBerS ^ surve Of S 19721 51'8.8855 Fax:19721 516-8A0 APPROVED EQUAL. CONTRACTOR WILL GRADING PLH1V PROVIDE DETAILS WITH BUILDING PLANS. BENCHMARKS: SITE BM l: sg0ure cut on the curb inlet directly north at LOT 1, BLOCK A WALL DETAIL ELEV se~~~ ~oncrete median in Sandy Loke Rd.; DENTON CREEK ®SANDY LAKE ADDITION NOT-TO-SCALE 6 SITE BM 2: A 5/B" iron rod with red plastic cap, Set /n CITY OF COPPELL TEXAS the gravel median approximately l18.50't /eel west of the ~~, ~~ pt~ y~ NOTES Alf N0. southwest property corner of site. ELEV :449.46' NOVEMBER H. t'=20' GSES GSES 2008 V. t"=5'