Denton Creek/Sandy Lake-CS090701(9/3/2009) DiWanna Baskins - RE: Akula Home Project, Denton Creek at Sandy Lake
From: "ROBERT SCHNEEBERG" <robert.schneeberg@gs-engineers.com>
To: "'DiWanna Baskins"' <dbaskins@ci.coppell.tx.us>
CC: "'Daniel St. Claire"' <ghomes@att.net>
Date: 712/20091:35 PM
Subject: RE: Akula Home Project, Denton Creek at Sandy Lake
Will that suffice to get them started? I will have final sets delivered
with the plat included if everything looks ok.
Robert schneeberg
Gonzalez &schneeberg, Engineers & Surveyors. Inc.
660 North Central Expressway, Suite 250
Plano, Texas 75074
Phone:972-516-8855 Fax:972-516-8901
-----Original Message-----
From: DiWanna Baskins [mailto:dbaskins@ci.coppell.tx.us]
Sent: Wednesday, July 01, 20091:57 PM
To: ROBERT SCHNEEBERG
Cc: 'Daniel St. Claire'; 'Raj'
Subject: RE: Akula Home Project, Denton Creek at Sandy Lake
As I review this pdf...
Let me remind you that a copy of the plat will need to be submitted with the
early grading plan set before the early grading permit can be approved.
»> "ROBERT SCHNEEBERG" <robert.schneeberg@gs-engineers.com> 711/200911:07
AM »>
DiWanna,
Try this. The owner and contractor asked me to revise the grading plan to
keep the retaining wall under 4 feet. Additionally, they told me they
wanted to construct a stacked stone and mortar gravity wall and that they
would provide details with the building plans.
Please take a look and let me know if we are ready to print final sets for
the grading permit.
Thanks,
Robert schneeberg
Gonzalez &schneeberg, Engineers & Surveyors. Inc.
660 North Central Expressway, Suite 250
Plano, Texas 75074
Phone:972-516-8855 Fax:972-516-8901
-----Original Message-----
From: DiWanna Baskins [mailto:dbaskins@ci.coppell.tx.us]
Sent: Monday, June 29, 200910:13 AM
To: Robert.schneeberg@gs-engineers.com
Subject: Akula Home Project, Denton Creek at Sandy Lake
Page
I prematurely sent the last a-mail.
(9/3/2009) DiWanna Baskins - RE: Akula Home Project, Denton Creek at Sandy Lake
I do have a couple of concerns regarding the submital. First is the
proposed wall. We will need engineering plans forthe wall. When do you
plan on building the wall? Also, some of the bold elevations are shown
higher than the FF.
Sincerely,
DiWanna Baskins
Graduate Engineer
Engineering Department
(P)972-304-3562
(F)972-304-3570
Page 2
,~~, ,~~ x 1 , I
\ .
~ I L \ \\
~ \ \
I ~ .
I ~ ~ ~00°1242 W \
= _- \
-M
1 t I, TP=449.80 - \'
,,,, TP-450.20 \ 135• \
s' •, ~ ; I DENTON CREEK LANG COMPANY- W=4 6.50 BW=446.50 \
1 1 ' 1 I °_,: 1316 SANDY LAKE RD. __--A4:i-- ----
I ~ I \ _. -- _ -_. --.. _. - V: 2003133, R. ~f5b9 „...- - - _. __ -- ~; ~, -
I _
..
_ _
.. l .. ,- _ -_.~
is ;! .. ,, Ay __ 0 ,,. .-._~
.y ~ .. "" ~° ..;..,..
.. ~,. i _` _ .._
1 0
I 446.,,, - _ \ _
\ s-
- - - -
1
~ r ~,_ \
446 _ 7P=450.70 TP=450.00 _\ 8
` ~ .P 2~ 5q.fl 449 _ _ ._ .496.50 _ \ ~ ~ ~ - 20 0 20 40
, _ `. ~ ~ \,~ bps-- ~ -
_,
, ~ 1 I 145 >•es _ ___ _ - ___ -- --- _--- \ ^`.
~.;;_ Scale in Feet
` I ^ ' ~ LO ;,BLOCK A ,--- ---- - --_ ...__..___-_._c5a' _ -- - _ \,,,, :, •a~e• .~ .
1 ~ 1 a~ ' ~` NTON CREEK a I _ ~ NE.au _ ~.. ~ 30:,,
`U •. , .
!
1 ~ , ANDY LAKE ADDITO wail ~, -- _ \ ~ ~ .. ~~, '"LEGEND
~.\ _
_-
~, - '. \~
..
' ' ~ I
~.-... \
~ {' t .:a' _ `~ \~ ~ ,°, ' :. \ TC=563.25 TOP OF CURB
~ \•z ' G56275 TOP OF GUTTER
I qn ~ ~. ', I II O If80 E. SANDY LAKE ROAD \ -
~.
~ ~ TWO-STORY
` ~~ I ~ ~ BRICK BUILDING ~! - \ ~ •'' ~ \ TP=565.00 TOP OF PAVEMENT
r ~ _, I RESIDENCE I i i ~ -.
.. ,.. ,
' *"A' ~ , BW=565.00 BOTTOM OF WALL
` 449 1 ~ a.~ FF_45L70' _. ~ \~_ \~~ "~
.4 j I ~ °, E. ~ F FLOW LINE
' I ~ 448 `~ ~ \\ \~ • ~, ~ 564 PROPOSED CONTOUR LINE
•„, • , 1
'~ r
rr,:y I ;\ \ 1 ~~+ WATER METER
-_____ __
1 1 443" ~ S 53°342j" E 1' \\ ~ ~~ .,, 1 ~ m~~ WATER VALVE
1 G I '' 7' \ r~~ tr LIGHT STANDARD
1. 60.36, 8.9 - _ ._ T - _ - _ I e ~ _ba~ \ 1 I
\ \\ r ' ` \~ • \ ', ~ TRANSFORMER
1 ` 1 4 6 ', ~
''~ E . / \' \ r ~ ~~ FIR HYDRANT
~ s~~, , ~ l~ 6` I - - - - N 50 OT 03" E _ _ 180.15' _ _ 451 ,;, ~ ~ ~\\ \\ ; , `II ,., E
o. , ~ 1 '{ I \ 451 N , 1 i ~ \ \~ ~J ~ METAL SIGN
I ~ ~ ~ I I '+ \ \\ \\~ •`~pp , ~~ SANITARY SEWER MANHOLE
r ,
1m. r, II 445 1 1 ~ 452 ~
1
+ ~ ~ ,- __. g - FENCE
q I l \- , ~~ i \ \~ I
1 ~ I ~ /II 1 I \ ~ .450 i~ '\\ \~ + ~ier TELEPHONE MANHOLE
0„ WptER 11 ,( 1 I \\ ~ 0' ~ I ~ \ '\\~ • ~' ny .. STORM MANHOLE
°, W ~ / 11 ' 11 `, a~ ~P soy I ~ . W ~ 1 ; \ , ; '/ ., \.. ~ ~
i ~ _, ,~
, ,
,~ 'I t0 I II ~ I F~~NF ~ ~ - - - - -~ - -~ ~ \ 1 ' /l /l - ~ ~~ _. \~~, ,.~f\
..
r +
i,
G 4M.64 ' ~. i i i I ~ 6a
_ ,
' .._,---
-' ~ / „.. '
1
o
_ 1 '. 1 y - ,
_ i ,, a,.
_ ,
11 __ ;
r ;; ~•, ~ I a . ~ rr,, ~ / ~, E v
~ 1 \ Imo, . ' ~' d / \ \
' t ! / I n--
l/ ~
1 / \ _ ~ - / i
4`°,~: 11 ~ ' .~/ // X36' \ \
` I ~
.,
~ ~ ~., . ~
< I '~_
~:
,~ ,
_ .;
1
o~ 5s I, 1 1 ~ `, ~ ~ ~ ~ ~ \
_ I ,, , ~.,,. ~ \ 36,922 sq.ft. -- -- ,!~ ;~ V `~ / .aA ,
c h ~ I y I 0.8476 acres v, /, ~, i 1 5
1 m - 11 1 1 _~ f ~, /
~ I+ ~ ~ 11 ', 1 ~ 1 1 i LOT 2, BLOCK A I ;/t . 1 / / ~
" ~ ' t ', ~ ! I DENTON CREEK ~ i ~ / ~ : ~',
i ', llt.~~~`- I 1 11 I SANDY LAKE ADDITION f ,~ ~ NOTE,
I
~ i ~ ,, /~~ ~ I I ;,~ - - - - - - - - -,` _,, f ; 1 _, No work ossocfOted with the approved CLOMR /s proposed
o i vR r ~ ~ Y \ J ' / I ! / , ~' of this t(me. That portion of the project is being delayed
1 '~ `'~ ~~ ', 11 j/ ',' ~ \ ~ _ I I I ~ ~9 until the commercial portion of the project Is cons)ructed In
1 f , ~~1 - ~ ~ 1' \ ~~-~ d~,° ,~ r I I I ~ry a subsequent phase.
_.
~' ...
S 50.07'03 327,9 '
111 ~ - - ~/
1 I x ~ \ HENRY H• TA 7E ~- ~ ~
'R `, \ 1200 SANDY LAKE RD. RODRaoUND j ' ' / 1h
1 ' V. 84098, P. 0782 ~
~ v. e4o9a P. o7e5 ~ 6 *>k Y *#
µ ~~ ~. _ D.R.D.~.T.__ ISSUED FOR GRADING ONL
r 't 4t ~ '~ r, \ T ' " -445- - _..- \ .. ~ /
° ~ r
1 , i cc,,~a
IXtIVE ~.~ / ~ & 5C
I ' - ~~ ~~ ,pTION YO E
~, ;/ ~y~ti5 33T
"gel zw iEOF.rF t ~~~,
+
1 N \ r ,P AOBEAT, W. SCNN~ERG
~ n 1 ~ ~~` 'h ~~`''`•TrTgTE~'•'\Z~
i ~ ~ SS .
1 ~ \ / 6 /ONAL `o"
I ' `rgs /
~ '~
1 ~r 1 ~ NEW HOUSE ~ THE SEAL APPEARING ON THIS DOCUMENT WAS
~} + ' ' ~~
1 V _ i ~ ~ ? / AUTHORIZED BY R09ERT W. SCHN®ERG, P.E 65352 ON
" ~ ~ 06/26/2009. ALTERATION CF A SEALED DOCUMENT
~. ~:~ ~ ~C~ \~, ~ WITHOUT PROPER NOI1FlCAl10N TO THE RESPONSIBLE
-~ "'.V . ~'1 ~ ENGINEER IS AN OFFENSE UNDER THE TEXAS
~•~ ° ~ ENGINEERING PRACTICE ACT.
,4 1 ~g .- ~ 1 w vARrEs
~ ~~ a
MONOLITHIC CURB Wl7H 6" /
-'~ a OPENING EVERY 70 FEET
1 1 - - a C2
' ~ 3 ~- 70 PERMIT DRAINAGE.
LESS THAN 4' 20 I
Gonzalez & Schneeberg 880 K Central Expressway
STACKED STONE AND MORTAR GRAVITY Suite 250, Plano, Tex 76074
5 RETAlNfNG WALL WITH DRAINS OR OWNER 817 IhBerS ^ surve Of S 19721 51'8.8855 Fax:19721 516-8A0
APPROVED EQUAL. CONTRACTOR WILL GRADING PLH1V
PROVIDE DETAILS WITH BUILDING PLANS. BENCHMARKS:
SITE BM l: sg0ure cut on the curb inlet directly north at LOT 1, BLOCK A
WALL DETAIL ELEV se~~~ ~oncrete median in Sandy Loke Rd.; DENTON CREEK ®SANDY LAKE ADDITION
NOT-TO-SCALE 6
SITE BM 2: A 5/B" iron rod with red plastic cap, Set /n CITY OF COPPELL TEXAS
the gravel median approximately l18.50't /eel west of the ~~, ~~ pt~ y~ NOTES Alf N0.
southwest property corner of site.
ELEV :449.46' NOVEMBER H. t'=20'
GSES GSES 2008 V. t"=5'