Loading...
SW0801-CS090717 (2)(9/4/2009) DiWanna Baskins -Denton Tap Sidewalk Project (Coppell, TX) 300 Denton Tap From: DiWanna Baskins To: bob.carroll~atmosenergy.com; david.cramer~atmosenergy.com Date: 7/17/2009 3:45 PM Subject: Denton Tap Sidewalk Project (Coppell, TX) 300 Denton Tap Attachments: SW08-01 PLANS-SHEET 17.pdf Hello Bob and David, Following up with the voicemail, I have attached a pdf showing the proposed location of the sidewalk that we would like to construct in the Enserch Corp ROW. Basically, anything that the city must do so that we can connect the sidewalk, let me know. Thanks! Sincerely, DiWanna Baskins Graduate Engineer Engineering Department (P)972-304-3562 (F)972-304-3570 Page 1 } ~ 1 . I - i I I i ~iR~ ~~, ~ • ~ ~~ I ~ ~ IA IL ~~~ ~f, I ~ - ~ • ~ .. ~ x i ~ ~ . , ~ ti. t ~r_~~_~._- - ~ __ _ ~ y~ _ ~ - ~.,, HORIZ ~_, zo o i o zo 1 inch = 20 ft. SIDEWALK LEGEND APP UTILITY POLE 040 ~ LIGHT PDSi , WV WATER VALVE m~ ~ ~ .. '. 9 -. 4 i' ~ ~ ~. E - ~ WM WA1ER METER T FH m ~ FlRE HYDRANT ' IJ I ~ I = - .` ~ ~J I UPA I ~ GUYWIRE v O~ m " ~ :,`. -t. ~ ,,* ~ MH ~ STORK SEVER MANHOLE ~ CQ MH SANITARY SEWER MANHOLE ~ ~,~~ SANITARY CLEANOUT T °~ EL MH O TELEPHONE MANHOLE Q TRAFFIC SIGN ~( _ - \. _ _ _ -^ ~ _~ - 11°la ~ - ' ~„`_ X X ~ X ~ ~ l~ SIGN EDGE OF CURB ~~ X , +~` EXISTING SIDEWALK ` <- ~ , ~ , N. ~. ~ ~ e. , ~.. ` . PROPOSED SIDEWALK ' , ^~ °. I l ~ . ~ .C ~ , .. `~~' ~ ~ ~ ._. GENERAL LEGEND R R,O.W /PROPERTY LINE . r ~ ~ -- " :` ~~ EASEMENT - ~ - ~ - ~ - WATER UNE vRt u ~~ - ~ ~ - - ~ I I - }~I~~~~',}~J_I~y~} N~ ' SANITARY SEWER s ss OVERHEAD TV/DATA ~' ~~ r _i ~~ I~ ~ _ ~ - I~ 7.;, ' ^'_ ~ "~ - ~+ 1 ~ OVERHEAD ELECTRIC acs UNDERGROUND lE1/DA TA wTc UNDERGRWND FIBER OPTIC uao UNDERGROUND ELECTRIC um TXU CAS LINE GAS ~ . •,+! 1 : t I 1. _.. i ' ~ ' 11 ``ii++`` +++` 11 ~'7~1111'~~I11~~'~1 PETROLEUM PIPELINE PEiRD SHEET 18 NOTE: 1. ALL DIMENSIONS ARE IN FEET AND TO THE BACK OF CURB UNLESS OTHERWISE SHOWN. 2. ALL WORK AND MATERIALS SHALL CONFORM TO CITY DF COPPELL STANDARD CONSTRUCTION DETAILS AND SPECIFICATIONS AND TxDOT SIGNALIZATION STANDARD PLANS, 3. ALL MATERIAL TO BE DEMOLISHED AND/OR REMOVED SHALL BE LEGALLY AND PROPERLY DISPOSED OF OFF-SITE. 4. PRIVATE PROPERTY WHICH IS DISTURBED OR DAMAGED DURING THE CONSTRUCTION SHALL BE RETURNED TO ORIGINAL CONDITION OR BETTER BY THE CONTRACTOR AT THEIR OWN EXPENSE. PRELIMINARY THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW UNDER THE AUTHORITY OF KEITH R. MARMN P.E. 89388 IT IS NOT TO BE USED FOR CONSTRUCTION, BIDDING OR PERMITTING PURPOSES SCALE; 1"=20FT PROJECT GENERAL NOTES 1. WS11NC UIIUtt DATA AND ALL OBSTAUC710NS SHOWN ARE PRONDED FOR INFDAMANON T VA E C I T Y O F NO. h E pr o OES O N S C ~ SIDEWALK -PLAN & PROFILE I r D NDT SLY OR ASSU ANY RE PIXHSIBLItt FOR iFE ACCURAC Y DF h115 DATA 2 THE CONTRACTOR IS TO VEIAFY 1HE LOCATION AND ELEVATION OF ANY EMIS11N0 VNUTES 'DEB DESIGNED. SVV08.01 PRIOR ro coxsmucnoN, ' ~ ~ ~~ DRAWN: KWR - SHEET 3. ALL WORK 9HAIL BE IN ACCORDANCE W11H THE Cltt OF COPPELL 3 DESIGN STANDARDS AW SPEgFlCAIIDNS ~ - _ - -' ~ f' ;,`'; ~~:~ ~ ~, - ~` a x e DATE: --___-- - Fl s ~ CITY OF COPPELL 17 N0. REVISION BY DATE PATH: S~DADvNrAOa-N~DA-~,LAN~DNS DALLAS COUNTY, TEXAS of 30