Loading...
North Gateway 9-CS090319CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT CASE NO.: PD-240R2-HC, North Gateway Center Lit 9 floc k A ~_----_- P&Z HEARING DATE: March 19, 2009 C.C. HEARING DATE: April 14, 2009 STAFF REP.: Matt S. Steer, City Planner LOCATION: NWC of S.H. 121 and Denton Tap Road SIZE OF AREA: 1 .624 acres of property CURRENT ZONING: HC (Highway Commercial) REQUEST: A zoning change to PD-240R2-HC (Planned Development- 240 Revision 2-Highway Commercial), to attach a Detail Site Plan to allow the development of an 8,100-square-foot structure for professional/medical office and personal service uses. APPLICANT Owner: Tom Wouters Realty Capital 99 Main St. #200 Colleyville, TX 76034 (817) 488-4200 FAX: (817) 424-2448 Engineer: Don Harrelson Baird Hampton Brown 4550 SH 360 # 180 Grapevine, TX 76051 (817) 251-8550 FAX: (817) 251-8810 Architect: Lisa Swift GSO Architects 5310 Harvest Hill Rd. # 146 Dallas, TX 75230 (972) 385-3462 FAX: (972) 385-3462 HISTORY: A site plan for a three-story, 68,350-square-foot medical office was approved January 2007, on a portion (6.67 acres) of this property and has since expired. The land remains vacant. ITEM # 8 Page 1 of 4 TRANSPORTATION: Denton Tap Road is a P6D divided major arterial built to standard in a 150-foot right-of-way. State Highway 121 has recently been completed as a 140-foot, six-lane divided tollway facility within a 450-foot right-of-way. SURROUNDING LAND USE ~ ZONING: North -residential; PD-134R-SF7 (Planned Development-134 Revised- Single Family-7) South -vacant; HC (Highway Commercial) East - Coppell Market Street Center; PD-228-HC (Planned Development-228-Highway Commercial) West -residential; PD-1348-SF7 (Planned Development-134 Revised- Single Family-7) COMPREHENSIVE PLAN: The Comprehensive Plan of May 1996 shows the property as suitable for freeway commercial uses. DISCUSSION: This is a request for a zoning change to PD-240R2-HC (Planned Development-240 Revision 2-Highway Commercial), to attach a Detail Site Plan to allow the development of an 8,100-square-foot structure for professional/medical office and personal service uses. This is Lot 9, Block A, the northernmost lot of the entire 12-acre proposal. This site has been well thought out with a large buffer yard on the north and west sides between the parking area and the Coppell Greens Subdivision. The applicant is not proposing to remove any of the existing major trees, maintaining the natural buffer currently in place. As mentioned in the Conceptual PD, the fourth leg of the Highland Drive traffic signal will need to be installed at the southern drive. This provides the entire 12-acre development a major ingress/egress point. A mutual access and fire lane easement will need to be shown at this location. The fire lane easement is required to encircle the building, and is noted as a condition of approval. The number of parking spaces required for a structure with 50% professional office and 50% medical office is 38. They are providing 45 parking spaces, exceeding the required. The personal service use (nail salon, hair salon, etc.) component is calculated at one parking space per 200- square-feet of building area; therefore, this use will not ITEM # 8 Page 2 of 4 exceed the allotted parking, as the medical office half was calculated at a ratio of one parking space per 175 square feet and the professional office has been calculated at a ratio of one space per 300 square feet. The parking area will be effectively screened from the Denton Tap right-of-way with the use of Chinese Fringe Flower. The landscape plan depicts Cedar Elms with Mexican Plums planted in groupings on Denton Tap as called for in the Streetscape Section of the Subdivision Ordinance. There is a six-foot reddish-brown brick screening wall proposed along the northern and western property lines. Currently, the wall is depicted on the Site Plan approximately ten-feet from the western property line and the same wall is shown directly on the property line on the Landscape Plan. The location of this wall should be consistent on all plans and should be constructed in a location, so as not to disturb the existing trees. The details for the proposed wall are shown on the elevation sheet. This depicts the wall segments with a ten-foot separation between the minor pilasters and a 30- foot separation between major columns. The proposed elevations match the conceptual planned development in materials and colors. The brick is proposed to be reddish-brown. A secondary beige stone material is proposed at the entries. Metal, grey canopies are proposed at the major entries with dark blue canvas awnings proposed above the remainder of the storefronts and doors. A grey standing-seam metal is proposed as the roof material. The proposed sign areas are depicted on the elevations. No specific attached signage is shown; therefore, it will need to comply with the sign section of the Zoning Ordinance. There is no proposed monument signage on-site as a multitenant sign is shown on the overall Conceptual PD on Lot 8, directly to the south. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff is recommending APPROVAL of this request subject to the following conditions being met: 1 . Ensure all comments related to the Final Plat are reflected within this Detail PD. ITEM # 8 Page 3 of 4 2. Include a dumpster enclosure on elevation sheet. This will need to show the same brick as the main structure and include a note that states that the gate remain closed when not in use. 3. Depict all existing and proposed easements on the Site Plan and Landscape Plan. 4. Label all colors on the black and white elevations. ALTERNATIVES: 1 . Recommend approval of the request 2. Recommend disapproval of the request 3. Recommend modification of the request 4. Take under advisement for reconsideration at a later date ATTACHMENTS: 1 . Detail Site Plan 2. Detail Landscape Plan 3. Detail Elevations ITEM # 8 Page 4 of 4 CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT North Gateway Center Lot 9, Block A Finnl Plnt P&Z HEARING DATE: March 19, 2009 C.C. HEARING DATE: April 14, 2009 STAFF REP.: Matt S. Steer, City Planner LOCATION: NWC of S.H. 121 and Denton Tap Road SIZE OF AREA: 1 .624 acres of property CURRENT ZONING: HC (Highway Commercial) REQUEST: A Final Plat to establish various utility and fire lane easements to allow the development of an 8,100-square-foot professional and medical office. APPLICANT: Owner: Tom Wouters Realty Capital 99 Main St. #200 Colleyville, TX 76034 (817) 488-4200 FAX: (81 7) 424-2448 Representative: Don Harrelson Baird Hampton Brown 4550 S H 360 # 180 Grapevine, TX 76051 (817) 251-8550 FAX: (81 7) 251-8810 Surveyor: Andrew Stevens Stevens Land Surveying 7300-8 Weatherford Hwy Fort Worth, TX 761 16 (817) 696-9775 FAX: (81 7) 696-9780 HISTORY: A site plan for a three-story, 68,350-square-foot medical office was approved January 2007, on a portion (6.67 acres) of this property and has since expired. ITEM # 9 Page 1 of 3 TRANSPORTATION: Denton Tap Road is a P6D divided major arterial built to standard in a 150' right-of-way. State Highway 121 has recently been completed as a 140' six-lane divided tollway facility within a 450' right-of-way. SURROUNDING LAND USE & ZONING: North -residential; PD-134R-SF7 (Planned Development-134 Revised- Single Family-7) South -vacant; HC (Highway Commercial) East - Coppell Market Street Center; PD-228-HC (Planned Development-228-Highway Commercial) West -residential; PD-134R-SF7 (Planned Development-134 Revised- Single Family-7) COMPREHENSIVE PLAN: The Comprehensive Plan of May 1996 shows the property as suitable for freeway commercial uses. DISCUSSION: This is the companion request to PD-240R2-HC. The proposed fire lane easement should encircle the building and not dead-end. This has been listed as a condition of approval within the staff recommendation. As mentioned in the previous cases, a Property Owner's Association is required for the maintenance of the drainage, pavement, and six-foot wall and landscaping. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff is recommending APPROVAL of this request subject to the following conditions being met: 1. A property owner's agreement is required for maintenance of drainage, pavement, six-foot masonry wall and landscaping. 2. Grading and drainage plans will be further evaluated during the engineering plan review. 3. Place the double check and meter in a vault in the 20' x 20' easement. The fire hydrant should come off of the private fire line. The detached FDC should be within 50-feet of the fire hydrant on the same side of the fire lane outside of the collapse zone. 4. Fire lane shall encircle the entire building. 5. Include width, bearings, distances and labels for each easement. 6. Correct vicinity map to show City limit line in the appropriate location. 7. Remove notary verbiage from under the City Secretary signature block, and include after the Surveyor's signature block. ITEM # 9 Page 2 of 3 ALTERNATIVES: 1 . Recommend approval of the request 2. Recommend disapproval of the request 3. Recommend modification of the request ATTACHMENTS: 1 . Final Plat iTEPJ~ # 9 Page 3 of 3