Coppell Heights 9-CS091001Sep 30 09 03:34p Debbie Ingram T H E C [ T Y O F CC~PPELL ~~ ~ o F q X A 6 ~ 6 MEMORANDUM TO: Larry Davis, Engineering FROM: Danny Hightower, Public Works DATE: September 30, 2009 REF: Coppell Heights Lot 9 B & C, 920 Belt Line Rd 972-462-5199 p.1 1. Re-mark MLV and FHV on curb on Belt Line 2. Remove seal in sidewalk to BO; replace pad in sidewalk BO on 24" water 3. Missing 1" water service on Belt Line 4. Reset 2" DOM meters to grade 5. Vault on Sanders Loflp needs to be dry and sealed; 3" for drainage around vault 6. Mark FLV in red on curb for Fire Lane Valve and paint cap red -east building 7. Re-mark FLV in red on curb for Fire Lane Valve and paint cap red -west building 8. MLV valve on S. Belt Line needs extension and paint valve lid blue for City 16" water main 9. Check sewer invert at MH on S. Belt Line 10. Maintenance bond 11. Required water vault easement adjacent to S. Belt Line Rd. Call 972-462-5150 to schedule Danny Hightower for afollow-up inspection after punchlist completion. Sep 30 09 02:55p Debbie Ingram 972-462-5199 p.1 MEMORANDUM FROM THE DEPARTMENT OF PUBLIC WORK To: Larry Davis, Construction Inspector Engineering From: Frank Garza, Streets Department Date: September 30, 2009 RE; Walk-thru 920 S. Beltline Rd 1. Need to rout & seal cracks around manhole on N. Beltline entrance. Marked with pink paint. 2. Need to seal curb next to storm box on E. Beltline entrance. Also need to remove redwood and seal next to ramp. Marked with pink paint. 3. Need to remove some felt and seal joint all the way ap to curb on median on E. Beltline. I1larked with pink paint. 4. Need to rout and seal cracks on Sanders Loop entrance. Marked with pink paint. 5. Maintenance bond 6. ADA accessibility report 7. All geotechnical reports for concrete /soil 8. Left turn lettering (ONLY) 9. Stamped concrete in E. Belt Line Rd. median is non-compliant to approved details & standards /~ ~~~ ~~-/C/TYOPCOPPP'LL PUBLIC WORXSDEPARTbfEA'T From:Coppell Fire Department 9723043514 09/3012009 11:11 #675 P. 0021002 ~~~p~e Yr~ rt ent Ins e~~i®n s_ r ~, 920 Se eltline, ~®pp~ll Teas 09/30/2009 1. Fire 17epartment Connections (FI~C) shall be painted either a matching building color or red to match fire hydrants. 2. FDC's shall be addressed: "920 suite 100" and "920 suite 200" as they correspond to each building. 3. Exterior walls in riser rooms shall be insulated. 4. Riser rooms shall be provided with heat source to prevent freezing pipes. 5. Suites 100 and 200 shall be provided with heat source to prevent freezing pipes. 6. -Riser rooms shall be provided with light fixture. 7. I~.nox boxes shall be placed on exterior portion of walls at riser room doors. Call Fire Marshal's Office prior to installation to discuss placement. 9'12-304-7057 8. Riser room doors shall be labeled on exterior side: Riser Room