ST0702-LR090828CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94091 174.0006
Service Date: 08/20/09 8901 Carpenter Frwy.
Report Date: OS/2S/09 Dallas, TX 75247
214-630-1010 Reg No: F-3272
Client Project
City o1'Coppell TX Coppell Road - #ST07-02
Attn: Ricl: O'Dell Bethel Road to
Engineering Dept Southwestern Blvd.
PO Box 9478 Coppell, TX
Coppell, TX 7SU 19 Project Number: 94091174
Material Information Sample Information
Specii'ied Strength: 4,000 psi rt 28 days
Mix ID: 1701
Supplier: Lattimore
Batch Time: 1414 Plant: 3
Truck No.: 1049 Ticltet No.: 3268211
Field Test Data
Test
Slump (in):
Air Content ('%~):
Concrete Temp. (f ):
Ambient Temp. (F):
Plastic Unit Wt. (pcf):
Result Specification
4
3.8
95
92
146.4
Laboratory Test Data
Set Specimen Diameter
No. 1 D (in)
I I 6.00
3 6.00
I ~ 6.00
1 4 (.00
Sample Date:
Sampled Sy:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
Age at
Area Date Date Test
(sq in) Received Tested (days)
28.27 08/22/09 08/27/09 7
28.27 08/22/09 09/03/09 14
28.27 08/22/09 09/17/09 28
28.27 08/22/09 09/17/09 28
08/20/09 Sample Time: 1503
James C. Blackwell
Clear
8 Batch Size (cy): 8
Dit•ect Discharge
0
0
See Placement Location
Inlet bottom @ Sta. 16+OS and G'
manhole
Maximum Compressive
Load Strength Fracture
(Ibs) (psi) Type
116,300 4,1 10 4
Comments:
Samples Made 13y: Terracon
Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast compressive strength
samples.
Terracon Rep.: .lames C. Blackwell Started: 1300
Reported To:
Contractor: .Ilt.l Paving
Report Dish•ibulion:
11) Lily of Coppell l'x
Finished: 1600
(I) Freese and Nichols Inc
Reviewed By:
Test Methods: AS"fM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C10G4, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Page I of I
~ ~ Rnou i ;-' ~ .no, Rcc ;