ST0702-LR090827FIELD DENSITY TEST REPORT
Report Number: 94091174.0005
Service Date: 08/20/09 8901 Carpenter Frwy.
Report Date: 08/27/09 Dallas, TX 75247
214-630-1010 Reg No: F-3272
Client Project
City of Coppell TX Coppell Road - #ST07-02
Attn: Riclc O'Dell Bethel Road to
Engineering Dept Southwestern Blvd.
PO Box 9478 Coppell, TX
Coppell, TX 75019 Project Number: 94091174
Material Information
Mat. Proctor
No. Ref. No.
1 94091174.0001
Field Test Data
Lab Test Data
Optimum Max. Lab
Water Dry Unit
Laboratory Content Weight
Classification and Description Test Method (%) (pef)
Dark brown silty clay, with sand ASTM D698 13.5 112.7
and asphalt
Test
No. Test Location
Probe Wet Water Water
Lift / Mat. Depth Density Content Content
Elev. No. (in) (pcf) (pcf) (%)
Project Requirements
Water Minimum
Content Compaction
(%) (%)
0/+4 95
Dry Unit Percent
Weight Compaction
(Pcfl (%)
36" RCP Storm Sewer, Line A
Sta. 8+45 1' beg 1 6 127.3 15.5 13.9 111.$ 99
Sta.8+50 Final 1 6 125.6 18.0 16.7 107.6 95
Sta. 4+00 1' beg 1 6 125.4 16.9 15.6 108.5 96
Sta.4+OS Final 1 6 127.5 17.1 15.5 110.4 98
30" RCP Storm Sewer, Line B
Sta. 16+30 1' beg 1 6 126.8 18.5 17.1 108.3 96
Sta. 16+35 Final 1 6 128.7 16.5 14.7 112.2 100
Datum: beg =below existing grade Gauge ID: 32769
Comments: Test results on this report meet project requirements as noted above.
Services: Perform in-place density and moisture content tests to determine degree of compaction and material moishu•e
condition.
Terracon Rep.: James C. Blackwell
Reported To: JRJ, Foreman
Contractor: JRJ Paving
Report Distribution: Reviewed By•
(1) City of Coppell TX (I) Freese and Nichols Inc
(I) JRJ Pavin6 LP E J. eveland, P.E.
Senior oject Manager
Test Methods: ASTM D6938
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
caooo~, aao.o9, ae~.z Page 1 of 1