Denton Creek NH-LR090709SAM ENGINEERING ~ TESTING, L.P.
Serving The Geo-Industry Since 1974
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910 • FAX; (972) 790-0967
Geoiechnical
Materials S.E~~. Failure
Testing Investigation
Environmental
CONCRETE PLACEMENT INSPECTION & STREN[~TH TEST Rf=pnRr
v-
CLIENT: SCI Construction, LTD STANDARD 6" X 12". v
5467 New Copeland Rd. AREA 28.27 SQ. IN.
Tyler, TX 75703
REPORT DATE: 7/9/09
PROJECT: Pro. Denton Creek Nursing Home
1410 E. Sandy Lake Rd. SAMPLE DATE: 7/9/09
Coppell, TX
PROJECT NO.: 108TX5K9
ATTN: Brandon Parker
REPORT NO.: 28
SE8~T TECHNICIAN: Jude Brignac
LOCATION OF PLACEMENT: East Fire Lane Paving-tie in @ South lake PAGE 1 OF 1
~,
~r~._ ~ ~ .. TEST f~AtA~ ~ ~
<> ~.
~ `; ',MAfiE
RfALS~SU1'PI_tER LIATA
Time Arrived: 8:45 AM Concrete Supplier: Cowtown
Time Left: 10:00 AM Ticket #: 525784
Slump (Inches): 4" Truck #: 932
Concrete Temperature (F): 86 Time Batched: 8:20 AM
Air Content: 4.75% Time Sampled: 9:20 AM
Total No, of Test C tinders Made 4 Product Code: 257
Total Cubic Yards Placed: 40 Cement: N/A
Added Water: N/A FI Ash: N/A
Weather Conditions: Cloudy Coarse A gre ate: N/A
Air Temperature (F): 86 Water: N/A
Unit Weigh t of Fresh Concrete: 147 % Air Content : N/A
~"pecimen Age '' Date Unit Wt, Total Load Connpressive Type of Strength Required':'
wz:-Number Da s Tested pcf Lbs, Stren th
psi Fracture
/d
s
.. p
i
a s
1A 7 7/16/09 3E00l2R
1 B
14
7/23/09 _
3600/28
1 C 28 8/6/09 3500/28
1 D 28 8/6/09 3600/28
Curing ASTM C-31 Test Method Cylinders Made By: Cylinders Tested By:
Slump ASTM C-143 ASTM C-39 & 231 SEAT
Remarks:
Very Truly Yours,
Mike Saint, Lab Manager & Vice President
Texas Professional Firm Registration No: F-001587
This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent.
This report only applies to the samples tested and does not necessarily represent identiral nr similar camnla¢
G:/2009/108tx5k9/Cpistr/CPISTR28/SA