Loading...
Denton Creek NH-LR090605A,FVt NG~NEER[NG ESTiNG, L.R. Serving The Geo-Industry Since 1974 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 • FAX: (972) 790-0967 IN-PLACE DENSITY OF SOIL Geotechnical Materials ~•I~~(T Failure Testing Investigation Environmental CLIENT: SCI Construction, LTD REPORT DATE: 6/5/09 TEST DATE: 6/4/09 5467 New Copeland Rd. Tyler, TX 75703 TEST METHOD:ASTMD-2922 & 3017 PROJECT: Pro. Denton Creek Nursing Home "ASTM D698A -See Proctor Report for details 1410 E. Sandy Lake Rd. Coppell, TX Minimum Required Compaction = 95% PROJECT #: 108TX5K9 REPORT #: 16 PAGE 1 OF 1 ATTN: Brandon Parker SE&T TECHNICIAN: Adel Alhemidawi TEST AREA FIEL D RESULTS LAB RESULTS LOCATION. LIFT # DEPTH FEET DENSITY PCF MC % MAT # MAX DEN PCF OPT MC % RANGE MC COMP % PASS/ FAIL Firelane @ East Side of Buildin Final 0.5 92 27 4 94 27 27-31 98 P Firelane @ South East Corner of Buildin Final 0.5 93 28 4 94 27 27-31 99 P Firelane @ South Side of Buildin Final 0.5 93 28 4 94 27 27-31 99 P Firelane @ South West Corner of Buildin Final 0.5 92 27 4 94 27 27-31 98 P Firelane @ West Side of Buildin Final 0.5 92 28 4 94 27 27-31 98 P Firelane South West Entrance Final 0.5 91 27 4 94 27 27-31 97 P Firelane @ South East Entrance Final 0.5 92 28 4 94 27 27-31 98 P Firelane @ Interior Parking Lot Final 0.5 93 28 4 94 27 27-31 99 P All densities meet the minimum required values unless otherwise noted. It has been a pleasure to serve you on this project and we trust that this report is satisfactory. Very Truly Yours, SAM Engineering & Testing, L. P. ._ .~ mike Saint, Lab Manager & Vice President G:/2009/108tx5k9/Density/DEN 16