Denton Creek NH-LR090605A,FVt NG~NEER[NG ESTiNG, L.R.
Serving The Geo-Industry Since 1974
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910 • FAX: (972) 790-0967
IN-PLACE DENSITY OF SOIL
Geotechnical
Materials ~•I~~(T Failure
Testing Investigation
Environmental
CLIENT: SCI Construction, LTD REPORT DATE: 6/5/09 TEST DATE: 6/4/09
5467 New Copeland Rd.
Tyler, TX 75703 TEST METHOD:ASTMD-2922 & 3017
PROJECT: Pro. Denton Creek Nursing Home "ASTM D698A -See Proctor Report for details
1410 E. Sandy Lake Rd.
Coppell, TX
Minimum Required Compaction = 95%
PROJECT #: 108TX5K9 REPORT #: 16 PAGE 1 OF 1
ATTN: Brandon Parker SE&T TECHNICIAN: Adel Alhemidawi
TEST AREA FIEL D RESULTS LAB RESULTS
LOCATION. LIFT
# DEPTH
FEET DENSITY
PCF MC
% MAT
# MAX DEN
PCF OPT
MC % RANGE
MC COMP
% PASS/
FAIL
Firelane @ East Side of Buildin Final 0.5 92 27 4 94 27 27-31 98 P
Firelane @ South East Corner of Buildin Final 0.5 93 28 4 94 27 27-31 99 P
Firelane @ South Side of Buildin Final 0.5 93 28 4 94 27 27-31 99 P
Firelane @ South West Corner of Buildin Final 0.5 92 27 4 94 27 27-31 98 P
Firelane @ West Side of Buildin Final 0.5 92 28 4 94 27 27-31 98 P
Firelane South West Entrance Final 0.5 91 27 4 94 27 27-31 97 P
Firelane @ South East Entrance Final 0.5 92 28 4 94 27 27-31 98 P
Firelane @ Interior Parking Lot Final 0.5 93 28 4 94 27 27-31 99 P
All densities meet the minimum required values unless otherwise noted. It has been a pleasure to serve you on this
project and we trust that this report is satisfactory.
Very Truly Yours,
SAM Engineering & Testing, L. P.
._ .~
mike Saint, Lab Manager & Vice President