Denton Creek NH-LR090604SAM ENGINEERING ~ TESTING, L.P.
Serving The Geo-Industry Since 1974
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910 • FAX: (972) 790-0967
IN-PLACE DENSITY OF SOIL
Geotechnical
Materials SE&T Failure
Testing Investigation
Environmental
CLIENT: SCI Construction, LTD REPORT DATE: 6/4/09 TEST DATE
5467 New Copeland Rd.
Tyler, TX 75703 TEST METHOD:ASTMD-2922 & 3017
PROJECT: Pro. Denton Creek Nursing Home *ASTM D698A -See Proctor Report for Details
1410 E. Sandy Lake Rd.
Coppell, TX
Minimum Required Compaction = 95%
~ PROJECT #: 108TX5K9
REPORT #: 14 PAGE 1 OF 1
6/3/09
ATTN: Brandon Parker SE8~T TECHN ICIAN: Adel Alhemidawi
TEST AREA FIEL D RESULTS LAB RESULTS "
LIFT DEPTH DENSITY MC 'MAT MAXDEN APT RANGE CAMP PAS
LOCATION # FEET ` PCF % # PCF MC % MC % '< FA
Firelane -Northeast Corner of Buildin Final 0.5 111 16 3 112 15 13-19 99 P
Firelane -North of Buildin Final 0.5 107 15 3 112 15 13-19 95.5 P
Firelane -Northwest Corner of Buildin Final 0.5 108 16 3 112 15 13-19 96.4 P
III densities meet the minimum required values unless otherwise noted. It has been a pleasure to serve you on this
project and we trust that this report is satisfactory.
/ery Truly Yours,
3AM Engineering es ing, L. P. -
!~~
~~
JI~ a ai t, L Manager & Vice President
G:/2009/108tx5k9/Density/DEN 14