Loading...
Denton Creek NH-LR090604SAM ENGINEERING ~ TESTING, L.P. Serving The Geo-Industry Since 1974 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 • FAX: (972) 790-0967 IN-PLACE DENSITY OF SOIL Geotechnical Materials SE&T Failure Testing Investigation Environmental CLIENT: SCI Construction, LTD REPORT DATE: 6/4/09 TEST DATE 5467 New Copeland Rd. Tyler, TX 75703 TEST METHOD:ASTMD-2922 & 3017 PROJECT: Pro. Denton Creek Nursing Home *ASTM D698A -See Proctor Report for Details 1410 E. Sandy Lake Rd. Coppell, TX Minimum Required Compaction = 95% ~ PROJECT #: 108TX5K9 REPORT #: 14 PAGE 1 OF 1 6/3/09 ATTN: Brandon Parker SE8~T TECHN ICIAN: Adel Alhemidawi TEST AREA FIEL D RESULTS LAB RESULTS " LIFT DEPTH DENSITY MC 'MAT MAXDEN APT RANGE CAMP PAS LOCATION # FEET ` PCF % # PCF MC % MC % '< FA Firelane -Northeast Corner of Buildin Final 0.5 111 16 3 112 15 13-19 99 P Firelane -North of Buildin Final 0.5 107 15 3 112 15 13-19 95.5 P Firelane -Northwest Corner of Buildin Final 0.5 108 16 3 112 15 13-19 96.4 P III densities meet the minimum required values unless otherwise noted. It has been a pleasure to serve you on this project and we trust that this report is satisfactory. /ery Truly Yours, 3AM Engineering es ing, L. P. - !~~ ~~ JI~ a ai t, L Manager & Vice President G:/2009/108tx5k9/Density/DEN 14