Loading...
Denton Creek NH-LR090529SAM ENGINEERING ~ TESTING, L. P. Serving The Geo-Industry Since 1974 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 • FAX: (972) 790-0967 GRADATION TEST REPORT Geotechnical Materials .SE&T Failure Testing Investigation Environmental DATE: 6/1/09 SAMPLE DATE: 5/29/09 CLIENT: SCI Construction, LTD PROJECT NO.: 108TX5K9 5467 New Copeland Rd. Tyler, TX 75703 REPORT NO.: 11 PROJECT: Pro. Denton Creek Nursing Home METHOD OF TEST: N.C.T.C.O.G. 4.6.4. 1410 E. Sandy Lake Rd. Coppell, TX PAGE 1 OF 1 ATTN: Brandon Parker SE8~T TECHNICIAN: Adel Alhemidawi RESULTS On the above date, representatives of SAM Engineering & Testing, L.P. performed the following te sting and inspection services: A. Three gradation tests were performed on the lime stabilized subgrade with the following results: Test #1 Firelane -NEC of Building 100% passing 1.75" 66 % passing no.4 sieve. Test #2 Firelane - N. Center of Building 100% passing 1.75" 69 % passing no.4 sieve. Test #3 Firelane - NWC of Building 100% passing 1.75" 63 % passing no.4 sieve. B. Based on the above data and our experience, the gradations of the stabilized subgrade meet/exceed the minimum requirement per N.C.T.C.O.G. 4.6.4. Very Truly Yours, Sadik (SAM) AI-Musawe, M.Sc., Ph.D., P.E., F.ASCE Civil & Environmental Engineer (Texas Registration Number: 61893 s.~# ~.#. •rrrN~rnrr9fod/6rP~e9r~~,~ SADIK JA~FC:R A;.-;?;)~,' a~'r\Jc ~ ~d~~~rree~ana~ ~r ~r,p,awae:~wea. is report is for the sole use of the client addressed. The use of our company name must receive prior written consent.' ' ` `•~''~ is report app{ies only to the sample tested and does not necessarily represent identical or similar samples. G:\2009\108tx5k9\grad\Grad 11