Denton Creek NH-LR090529SAM ENGINEERING ~ TESTING, L. P.
Serving The Geo-Industry Since 1974
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910 • FAX: (972) 790-0967
GRADATION TEST REPORT
Geotechnical
Materials .SE&T Failure
Testing Investigation
Environmental
DATE: 6/1/09 SAMPLE DATE: 5/29/09
CLIENT: SCI Construction, LTD PROJECT NO.: 108TX5K9
5467 New Copeland Rd.
Tyler, TX 75703 REPORT NO.: 11
PROJECT: Pro. Denton Creek Nursing Home METHOD OF TEST: N.C.T.C.O.G. 4.6.4.
1410 E. Sandy Lake Rd.
Coppell, TX PAGE 1 OF 1
ATTN: Brandon Parker SE8~T TECHNICIAN: Adel Alhemidawi
RESULTS
On the above date, representatives of SAM Engineering & Testing, L.P. performed the following te sting and inspection
services:
A. Three gradation tests were performed on the lime stabilized subgrade with the following results:
Test #1 Firelane -NEC of Building 100% passing 1.75" 66 % passing no.4 sieve.
Test #2 Firelane - N. Center of Building 100% passing 1.75" 69 % passing no.4 sieve.
Test #3 Firelane - NWC of Building 100% passing 1.75" 63 % passing no.4 sieve.
B. Based on the above data and our experience, the gradations of the stabilized subgrade meet/exceed the
minimum requirement per N.C.T.C.O.G. 4.6.4.
Very Truly Yours,
Sadik (SAM) AI-Musawe, M.Sc., Ph.D., P.E., F.ASCE
Civil & Environmental Engineer
(Texas Registration Number: 61893
s.~#
~.#. •rrrN~rnrr9fod/6rP~e9r~~,~
SADIK JA~FC:R A;.-;?;)~,' a~'r\Jc ~
~d~~~rree~ana~ ~r ~r,p,awae:~wea.
is report is for the sole use of the client addressed. The use of our company name must receive prior written consent.' ' ` `•~''~
is report app{ies only to the sample tested and does not necessarily represent identical or similar samples.
G:\2009\108tx5k9\grad\Grad 11