Duke Lesley 3A-LR091230Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: Duke Construction, LP Report No.: 365477 14241 Dallas Pkwy, Ste 1000 Project No.: 0915747 Dallas, TX 75254 -2936 Date of Service: 12/22/2009 Report Date: 12/30/2009 Project: Samsung -Point West VII Parking Lot Expansion Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: LMC Plant: 07 Specification Requirements Batch time: 05:1 lam Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air ( %): 3% -6% Test Method: ASTM C -172 Parking lot paving, east of west point #VII ASTM C -31 (except 10.1.2) 1 1 ASTM C -143 7 ASTM C -231 3,870 ASTM C -1064 1 2 ASTM C -138 28 ASTM C -39 Mix Design I.D.: 1621 Measured Placement Date: 12/22/2009 Slump Weather Conditions: Cloudy (inches) Time Sampled: 07:00am Batch time: 05:1 lam Temperature - Air: 56 °F Concrete: 62 °F Truck No: 5016 Ticket No: 7213296 `- Air Content: 3.7% Unit Weight (pcf): NA Overall Placement Location: (in) (in =) (Ibs) Parking lot paving, east of west point #VII Type Sample Location: 60' south, 10' east from northwest corner of parking lot REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder I Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in =) (Ibs) (psi) Type 1 1 12/29/2009 7 5.99 28.18 109,170 3,870 Type 2 1 2 01/19/2010 28 1 3 01/19/2010 28 4 02/16/2010 56 L1__JN I LJI �*_'__ I Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /KW) Page 1 of 10 8908 Ambassador Row, Dallas, TX 75247 Ro n e Engineering 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Repo of Concrete Compressive Strength Test Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254 -2936 Report No.: 365477 Project No.: 0915747 Date of Service: 12/22/2009 Report Date: 12/30/2009 Project: Samsung -Point West VII Parking Lot Expansion Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Results to superintendent. Water added at site: 10 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /KW ) Page 2 of 10 Ro n e Engineering 7701 8908 Ambassador Row, Dallas, TX 75247 W Little York, Ste 600, Houston, TX 77040 ■ 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Compressive Strength Test Client: Duke Construction, LP Report No.: 365477 14241 Dallas Pkwy, Ste 1000 Project No.: 0915747 Dallas, TX 75254 -2936 Date of Service: 12/22/2009 Report Date: 12/30/2009 Project: Samsung -Point West VII Parking Lot Expansion Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: LMC Plant: 07 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air ( %): 3%-6% Test Method: ASTM C -172 2 1 ASTM C -31 (except 10.1.2) 7 5.99 28.18 ASTM C -143 4,140 Type 6 ASTM C -231 01/19/2010 ASTM C -1064 ASTM C -138 2 3 ASTM C -39 Mix Design I.D.: 1621 Placement Date: 12/22/2009 Weather Conditions: Cloudy Time Sampled: 08:00am Temperature - Air: 59 °F Truck No: 3012 Air Content: 3.9% Overall Placement Location: Parking lot paving, east of west point #VII Sample Location: 20' north, 10' east from northeast island REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Measured Slump (inches) Batch time: 07:01 am 6.0 Concrete: 60 °F Ticket No: 7213312 Unit Weight (pcf): NA Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 2 1 12/29/2009 7 5.99 28.18 116,530 4,140 Type 6 2 2 01/19/2010 28 2 3 01/19/2010 28 2 4 02/16/2010 56 L I I I I P. It I IXJ n 4-d- 2' L 11 [-ILI El Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /KW) Page 3 of 10 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 R eport of Concrete Compressive Strength Test Lment: UuKe Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254 -2936 Report No.: 365477 Project No.: 0915747 Date of Service: 12/22/2009 Report Date: 12/30/2009 Project: Samsung -Point West VII Parking Lot Expansion Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Results to superintendent. Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /KW) Page 4 of 10 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Compressive Strength Test Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254 -2936 Report No.: 365477 Project No.: 0915747 Date of Service: 12/22/2009 Report Date: 12/30/2009 Project: Samsung -Point West VII Parking Lot Expansion Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: LMC Plant: 07 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air ( %): 3%-6% Test Method: ASTM C -172 ASTM C -31 (except 10.1.2) ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 Mix Design I.D.: 1621 Placement Date: 12/22/2009 Weather Conditions: Cloudy Time Sampled: 09 -00am Temperature -Air: 56 °F Truck No: 5013 Air Content: 4.5% Overall Placement Location: Parking lot paving, east of west point #VII Sample Location: 30' south, 10' east from northeast island REPORT OF TESTS Measured Slump (inches) Batch time: 08:48am 5.5 Concrete: 60 °F Ticket No: 6363746 Unit Weight (pcf): NA Concrete Compressive Cylinder 6" x 12" 01/19/2010 Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 3 1 12/29/2009 7 5.99 28.18 113,810 4,040 Type 5 3 2 01/19/2010 28 3 3 01/19/2010 28 3 4 02/16/2010 56 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /KW) Page 5 of 10 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Compressive Strength Test Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254 -2936 Report No.: 365477 Project No.: 0915747 Date of Service: 12/22/2009 Report Date: 12/30/2009 Project: Samsung -Point West VII Parking Lot Expansion Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Results to superintendent. Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /KW) Page 6 of 10 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Compressive Strength Test Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254 -2936 Report No.: 365477 Project No.: 0915747 Date of Service: 12/22/2009 Report Date: 12/30/2009 Project: Samsung -Point West VII Parking Lot Expansion Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: LMC Plant: 07 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air ( %): 3%-6% Test Method: ASTM C -172 4 1 ASTM C -31 (except 10.1.2) 7 5.99 28.18 ASTM C -143 2,960 Type 2 ASTM C -231 01/19/2010 ASTM C -1064 ASTM C -138 4 3 ASTM C -39 Mix Design I.D.: 1621 Placement Date: 12/22/2009 Weather Conditions: Cloudy Time Sampled: 11:20am Temperature - Air: 60 °F Truck No: 1039 Air Content: 5.9% Overall Placement Location: Parking lot paving, east of west point #VII Sample Location: 55' south, 20' east from northeast island REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Measured Slump (inches) Batch time: 6.25 Concrete: 64 °F Ticket No: 6363760 Unit Weight (pcf): NA Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 4 1 12/29/2009 7 5.99 28.18 83,500 2,960 Type 2 4 2 01/19/2010 28 4 3 01/19/2010 28 4 4 02/16/2010 56 [ILI I] Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 7 of 10 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Compressive Strength Test Client: Duke Construction, LP Report No.: 365477 14241 Dallas Pkwy, Ste 1000 Project No.: 0915747 Dallas, TX 75254 -2936 Date of Service: 12/22/2009 Report Date: 12/30/2009 Project: Samsung -Point West VII Parking Lot Expansion Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Results to superintendent. Water added at site: 10 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /KW) Page 8 of 10 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Re port of Concrete Compressive Strength Test Client: Duke Construction, LP Report No.: 365477 14241 Dallas Pkwy, Ste 1000 Project No.: 0915747 Dallas, TX 75254 -2936 Date of Service: 12/22/2009 Project: Samsung -Point West VII Parking Lot Expansion Report Date: 12/30/2009 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: LMC Plant: 07 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air ( %): 3%-6% Test Method: ASTM C -172 28 ASTM C -31 (except 10.1.2) 01/19/2010 ASTM C -143 5 4 ASTM C -231 56 ASTM C -1064 ASTM C -138 ASTM C -39 PROJECT DATA Mix Design I.D.: 1621 Placement Date: 12/22/2009 Weather Conditions: Cloudy Time Sampled: 01:10pm Temperature - Air: 62 °F Truck No: 1098 Air Content: 5.1% Overall Placement Location: Parking lot paving, east of west point #VII Measured Slump (inches) Batch time: 11:58am 6.25 Concrete: 64 °F Ticket No: 6363773 Unit Weight (pcf): NA Sample Location: 40' north, 20' east from southwest island REPORT OF TESTS Cylinder Marked Date Age Set No. Tested (days) 5 1 12/29/2009 7 5 2 01/19/2010 28 5 3 01/19/2010 28 5 4 02/16/2010 56 Concrete Compressive Cylinder 6" x 12" Maximum Diameter Area Load (in) (in') (Ibs) 5.99 28.18 95,830 . I Ir — F, �_X]N Ad Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Compressive Strength (psi) 3,400 Fracture Type Type 2 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /KW) Page 9 of 10 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Compressive Strength Test Client: Duke Construction, LP Report No.: 365477 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254 -2936 Project No.: 0915747 Date of Service: 12/22/2009 Project: Samsung -Point West VII Parking Lot Expansion Report Date: 12/30/2009 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Results to superintendent. Water added at site: 10 gallons Technician: Jose Villanueva Started Report Distribution: Ong: Duke Construction, LP (Dallas, TX) Attn: Ms. Ashley Hair (1 -ec copy) 1 -ec Duke Construction, LP Attn: Mr. Andy (Maverick) Otten 1 -ec Rone Project Manager Attn: Mr. K. Scott Watson AET 1 -ec City of Coppell Attn: Mr. Lee Stone 05:00am Finished: 03:00pm Rone Engineering 1 K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /KW) Page 10 of 10 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of In -Place Density Testing Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Report No.: 365449 Dallas, TX 75254 -2936 Project No.: 0915747 Date of Service: 12/21/2009 Project: Samsung -Point West VII Parking Lot Expansion Report Date: 12/30/2009 Coppell, Texas Services: Perform In -Place Density Testing PROJECT DATA Contractor: Duke Construction, LP Test Method: ASTM D -6938 Standard Counts Gauge: Troxler 3430 Moisture Density Gauge Serial No: 34008 Current: 642 Current: 2406 Test Mode: DT Previous: 645 Previous: 2411 MOISTURE DENSITY RELATIONS Maximum M/D No. Description Moisture Density Project Requirements 365094 Tan and Brown / Fat Clay % (pcf) Moisture Density 21.4 102.9 Optimum +4 95 min FIELD DENSITY TESTS Test No Test Location Probe M/D Moisture Wet Density Dry Density Density Depth No. Paving subgrade % (pcf) (Pcf) ( % max) 1 50' south, 40' west of south storm drain, final 6" 365094 Paving subgrade 21.8 123.5 101.4 99 2 55' south, 20' east of south storm drain, final 6" 365094 22.2 Paving subgrade 125.0 102.3 99 3 40' north, 25' east of south storm drain, final 6" 365094 21.6 Paving subgrade 123.4 101.5 99 4 50' north, 40' west of south storm drain, final 6" 365094 22.3 125.0 102.2 99 Technician: Steve Sorem Started Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attm Ms. Ashley Hair (1 -ec copy) 1 -ec Duke Construction, LP Attn: Mr. Andy (Maverick) Otten 1 -ec Rone Project Manager Attn: Mr. K. Scott Watson AET 1 -ec City of Coppell Attn: Mr. Lee Stone 02:45pm Finished: 04:30pm Rone Engineering n K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 1