Duke Lesley 3A-LR091221Rone Engineering 7701 8908 Ambassador Row, Dallas, TX 75247
W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630 -9745
Report of In -Place Density Testing
Client: Duke Construction, LP
Report No.: 365089
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254 -2936
Project No.: 0915747
Date of Service: 12/16/2009
Report Date: 12/21/2009
Project: Samsung -Point West VII Parking Lot Expansion
Coppell, Texas
Services: Perform In -Place Density Testing
PROJECT DATA
Contractor: Duke Construction, LP
Standard Counts
Test Method: ASTM D -6938
Gauge: Troxler 3430
Moisture Density
Gauge Serial No: 34008
Current: 644 Current: 2392
Test Mode: DT
Previous: 648 Previous: 2305
MOISTURE DENSITY RELATIONS
Maximum
Moisture
Density Project Requirements
MID No. Description %
(pcf) Moisture Density
365094 Tan and Brown / Fat Clay
21.4
102.9 Optimum +4 95 min
FIELD DENSITY TESTS
Test
No
Probe MID Moisture Wet Density Dry Density Density
Test Location
Depth No.
% (pcf) (pcf) (% max)
Paving subgrade
1 40' west, 10' north of center storm drain,
final 6" 365094
18.8* 127.9 107.7 105
An asterisk ( *) appears next to results which do NOT meet the project specifications
Technician: Steve Sorem Started: 09:00am Finished: 10:30am R E
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX)
Attn: Ms. Ashley Hair (1 -ec copy)
1 -ec Duke Construction, LP Attn: Mr. Andy (Maverick) Otten
1 -ec Rone Project Manager Attn: Mr. K. Scott Watson AET
1 -ec City of Coppell Attn: Mr. Lee Stone
one ngineenng
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/KW)
Page 1 of 1