Loading...
Shake & Shingle 2-CS100125Jan 25 10 08:45a Hennessey Engineering 9722457087 p.l HENNESSEY E ;GINEERING, INC. 1417 W. MAIN ST. - SUITE 100 - CARROLLTON, TEXAS 75006 -6912 (972) 245 - 9473 - FAX (972) 245 -7087 El TRANSMITTAL 1:1 TELEPHONE ❑ MEETING OBSERVATION JOB NAME: K.� A M? 5t���1l�r� � INHOUSE DISTRIBUTTIO1s DATE. -- 14IV4v4RY Z' 2G' /Z9 JOB NO. FROM: TO: f='F� f � 4 1/�S : C 'r�J � L'77C/� %/�. TZ Liz 41W 41PP&I 04L =real ENVIRC NMENTAL STRUCTURAL CIVIL PLANNING SURVEYING Jan 25 10 08:45a Hennessey Engineering 9722457087 p.2 MATERIAL SUBMITTAL INDEX A. WATER MATERIALS: Gl: Diamond Pipe: 6 - 8" DR14 CL20(i PVC Pipe for Public Water & Fire Line 2. Presco: 2 "x1000' Detectable Tape for Water Line Installation 3. American: 6" CL52 Tyton Joint D [etile Iron Pipe for In -Bldg Fire Line Riser Mueller: #A423 5' Bury Super Centurion Model Fire Hydrant Romac: 8x8 & 8x6 Tapping Sleeve (,6- Mueller: 6 - 8" #A -2360 Resilient 'Tdedge Gate Valve lJ/. Bass & Hays: #2436 -S USA Adju, table Cast Iron Valve Box L.W"' 6 - 8" Compact Ductile Mechanical Joint Fittings - C 153 t-4 3000 PSI Concrete Bat -,h Design for Blocking at Fittings le . EBAA -Seal: 8" - 6" #2000 -PV M -,chanical Joint Restraint LYl. Mueller: 1 -1/2" K Soft Copper Tu ping for Public Service from Main to Meter t4l. Charlotte: 1" SCH 40 PVC for Dc mestic Service from Meter to 5' of building Ik`3: Mueller: #BR2B Dbl. Strap Bronz.: Service Saddle for Irrigation & Domestic +fi4. Mueller: #B25000 1 -1/2" Flare Cc -poration Valve for Meter Service a5. Mueller: #B25166 1-1/2" Flare Sti light Meter Valve for Meter Service L.1'6. Mueller: #B242399000 1 -1/2" Mater Setter per Coppell Specification 1 -n. Bass & Hays: #55 -AIS Galvanize, Meter Box for 1 -1/2" Meter Service L4 Park Equipment: 8" Double Check Detector Check Assembly & Vault !.1 Roemer: #5715 6" x 2 -Wai Rough Brass Fire Department Connection t?16'. Nibco: 6" ULFM Cast Iron Swin€ Check Valve w /' /2" Ball Drip X21. ProFlo: 1" Frost Proof Hydrant B. SANITARY SEWER MATERIALS: t L Diamond Pipe: 4" SDR35 PVC Sc wer Pipe .:2. PW Eagle: Wastewater Access De lice C. STORM SEWER MATERIALS: ". Park: 24" Type B Headwall d2. ADS: 4 - 24" Silt Tight Corrugated HDPE for Private Drainage 3. ADS: H -20 Nyoplast Hinged Drai Ls 4. Draintech: 12" Landscape Drains 5. Lattimore: 4200 PSI Mix Design f,)r Concrete Structures and Pavement Replacement Feb 02 10 08:49a Hennessey Engineering 9722457087 HENNESSEY FiNGINEERING 1417 W. MAIN ST. - SUITE 100 - CARROLLTON, TEXAS 75 (972) 245 -94 '8 - FAX (972) 245 -7087 n TRANSMITTAL El TELEPHON:3 El MEETING 006 -6912 OBSERVATION JOB NAME: So L DATE: --�'��y 2G1G JOB NO. J g j % 2. FROM: 'AWE INHOUSE DISTRIBUTTION To: LAP-AV b *VlS 07Y OF CZ - . TAX' q.5 5 .:36-j FAY 5 72 ?D . 3 - 76 XI ;4/ 7"fj�_� 2. I "' Z"� TEL IN LLL'L /N CT �V . ENVIRO �NMENTAL STRUCTURAL CIVIL PLANNING P.1 INC. r SURVEYING