SS9301-SP 930503 (7)Poly Line FE-100
Coatings Lining Systems for New Construction or the
Rehabilitation of Wastewater Structures and Pipe
DESCRIPTION:
POLY LINE FE-100 is a two-component, 100% solids epoxy lining'designed for
high build vertical and overhead applications. It was designed as a chemically
resistant liner to be applied on damp or dry concrete surfaces such as man-
holes, lift stations and large diameter pipes. Th,~.pmDe, d¥_a_p.p, lied and cured .
POLY LINE FE-IO0 forms a monolithic liner whi ~h will protect tl~- (~-on'(~ret~ffTO,,,
degradation by sewer gases and prevent infHtr~.tion a.f..oj'.e, un~tl~r itfl~.the
sewer system. ~.,w~ISUL't-iNG Erq~I~IEERs
This ch~r'k il rm!y f~-r review ~t glner~,! ¢onfor-
~*a,~ce w;th the des;~n co'~cept of the I~ro!ect
· geueral Compliance with the iaforreitio~ given
the COntract docume.~ts.
ADVANTAG ES: C~,r.ct~oo~.. . or .c°mma"ts, made o, the ,hep draw-
· 100% solids system for improved per' c~=~lP,~':th's re~.l~ e= net relieve c'oetractor
~'c~p~,accs w~th r~ulremlNt~ If t~ ce~
, tract drawln,~s and s~ificatio~s,
· Used and applied in wet or dry enwr~mems
T~e coetractor is ~n~ble for coeflr '
· Chemically cured for a non-toxic epo:~r~ae~ ~j quantiti~ a~ ~imensioa= mill and
· Requires only one coat for coverage ~No Exceptiens Tak~ Mike Cerr~Joel Not~
· A pinhole free finish ~'Re/~ed ~R~ise& Res~bm~
~ s~:s~l~ ~t~~
· Excellent resistance to chemicals a~ gase~common~y round
in wastewater systems D ate~__ ~y_~~ ~
· Trowelable-- Brushable--Sprayable .................. -
· Excellent adhesion to concrete, metal, wood or masonry surfaces
· Adds structural integrity to coated surface ~"s ~,-;P
~'" ~ ""~-~"-;.';) TO BE IN
?.'r:,r ' ' ' ~--"r '.; - ~-CUMEN~ IN~
· Elongates over cracks ~,~;';~. · .a
~r' ,'::.,J..~DA. ~,'~ANCE O~E~ AND F~
· Cost effective alternative to manhole replacement
PERFORMANCE DATA: ~,~
POLY LINE FE-100 coating applications are suitable wherever extreme corrosive.
abrasive or moisture resistant solutions are being sought, at reasonable costs.
SURFACE PREPARATION:
All surfaces to be prepared shall be free of any concrete curing agents, oils.
bacterial or algae growth, grease or oily residue.
A waterblast of 2500 psi or more may be necessary to remove loose matter or
contaminants from surface to be coated·
Seal all act~ve hydrostatic leaks prior to application of POLY LINE FE-100.
MIXING:
POLY LINE FE-100 is supplied as two components. Part A being the resin and
Part B the curing compound. Pour and scrape Part B into Part A and mix using
a "Jiffy Mixer" for five (5) minutes until a uniform color is achieved.
APPLICATION:
POLY LINE FE.100 may be applied using either a stiff paste brush or steel
trowel to a thickness of up to 65 mils on vertical and overhead surfaces.
When applying POLY LINE FE-100 to dry concrete surfaces, work the lining
material into the surface by applying and finishing in a crosshatch pattern.
Applying POLY LINE FE-100 to damp concrete surfaces requires that a thin
layer be squeegeed into the surface leaving only a few mils of material. The
remaining material can then be applied to achieve the desired liner thickness.
COVERAGE:
Application thickness of 40 mils will yield - 40 sq. ft. per gal.
PRECAUTIONS: '
POLY LINE FE-100 should be applied only when substrate and ambient
temperatures are above 40°F. Thinners and solvents should not be used to thin
POLY LINE FE-100 as the solvents will prevent the liner from curing properly.
Clean equipment with mineral spirits or lacquer thinners.
SAFETY:
Wear protective clothing, goggles and gloves when working with POLY LINE
FE-100. Read the Material Safety Data sheets before using these materials.
STORAGE:
Containers of POLY LINE FE-100 should be stored in a cool dry place both
before and after mixing. This will help prolong the pot life of the mixed lini.qg
material.
THANE-COAT
DISTRIBUTED BY: 10400 WESTOFFICE DR. # 120
HOUSTON, TEXAS 77042
(713) 780-O990