ST0701-LR100222CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091193.0077 Irerracon Service Date: 01/25/10 8901 Carpenter Frwy. Report Date: 02/22/10 Revision 2 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client City of Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Project Southwestern Boulevard Coppell Road to Grapevine Creek Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ Mix ID: 1701 Supplier: Lattimore Batch Time: 1127 Plant: Truck No.: 7025 Ticket No. 28 days 6 6365113 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pef): Result Specification 3 1/2 3 -5 4.3 3 -6 62 58 150.7 Laboratory Test Data Sample Date: 01/25/10 Sample Time: 1247 Sampled By: Barry Cuble Weather Conditions: Sunny, breezy Accumulative Yards: 3.5 Batch Size (cy): 3.5 Placement Method: Direct Discharge Water Added Before (gal):8 Water Added After (gal): 0 Sample Location: See Placement Location Placement Location: Pavement, inlet strip at Sta. 3 +95 Set Specimen Diameter Area Date Date No. ID (in) (sq in) Received Tested 1 1 6.00 28.27 01/26/10 02/01/10 1 2 6.00 28.27 01/26/10 02/08/10 1 3 6.00 28.27 01/26/10 02/22/10 1 4 6.00 28.27 01/26/10 02/22/10 Age at Maximum Compressive Test Load Strength Fracture (days) (lbs) (psi) Type 7 126,300 4,470 2 14 143,240 5,070 4 28 157,190 5,560 4 28 158,350 5,600 2 Average (28 days) 5,580 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and c t compres . ve strength samples. Terracon Rep.: Barry Cuble Started: 1130 Reported To: Finished: 1330 Contractor: Lacy Construction Report Distribution: (1) City of Coppell TX (1) City of Coppell TX Reviewed By: (I) City or Coppell TX (2) HalffAssoc Inc Eric J. le eland, P.E. (1) Lacy Construction (1) PacTrust Pacific Realty Associates LP Senior Proj et Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5- 21 -09, Rev.3 Page 1 of t CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 193.0074 Irerracon Service Date: 01/22/10 8901 Carpenter Frwy. Report Date: 02/22/10 Revision 2 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell 'I'X Southwestern Boulevard Attn: Keith Marvin Coppell Road to Grapevine Creek PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: DCSO1 -1504 Supplier: Redi -Mix Batch Time: 0959 Plant: 136 Truck No.: 1219 Ticket No.: 25157804 Field Test Data Test Slump (in): Air Content (' %o): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pel): Result Specification 4 1/2 3 -5 5.4 3 -6 65 60 150.9 Sample Date: 01/22/10 Sample Time: 1036 Sampled By: Barry Cuble Weather Conditions: Sunny, breezy Accumulative Yards: 20 Batch Size (cy): 10 Placement Method: Pump Water Added Before (gal):5 Area Water Added After (gal): 0 Sample Location: 10' N of S Wall & 20' W of E Edge Placement Location: Bridge Deck, Span #2, mid -span Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. I D (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 01/23/10 01/29/10 7 132,140 4,670 2 1 2 6.00 28.27 01 /23/10 02/05/10 14 145,830 5,160 2 1 3 6.00 28.27 01/23/10 02/19/10 28 153,540 5,430 6 1 4 6.00 28.27 01/23/10 02/19/10 28 150,310 5,320 6 Average (28 days) 5,380 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made 13y: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast compressive strength samples. Terracon Rep.: Barry Cubic Started: 0930 Lunch / on- h g e: 1.00 Reported To: Finished: 1330 Contractor: Lacy Construction Report Distribution: (1) City of CoppelI Tx (1) City of Coppell TX Reviewed By: (1) City of Coppell 'rx (2) hlnlff Assoc Inc I eland, P.E. (1) Lacy ConMuction (1) PacTrust Pacific Realty Associates LP Senior Pro'ect Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001,5_21.09,lte,.3 Page 1 of I CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091193.0075 Irerracon Service Date: 01/22/10 8901 Carpenter Frwy. Report Date: 02/22/10 Revision 2 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Southwestern Boulevard Coppell Road to Grapevine Creels Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 3,000 psi @ 28 days Mix ID: DCB00501 Supplier: Redi -Mix Batch Time: 1205 Plant: 136 Truck No.: 1189 Ticket No.: 25157962 Field Test Data Test Slump (in): Air Content ('Yo): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pct): Result Specification 3 1/2 3 -5 2.5 0.5 -2.5 67 63 153.1 Sample Date: 01/22/10 Sample Time: 1244 Sampled By: Barry Cubic Weather Conditions: Sunny, breezy Accumulative Yards: 10 Batch Size (cy): 10 Placement Method: Pump Water Added Before (gal):10 Water Added After (gal): 0 Sample Location: 15'S of Bridge, YE of W Edge Placement Location: Riprap, south span Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 01/23/10 01/29/10 7 101,930 3,610 2 1 2 6.00 28.27 01/23/10 02/05/10 14 110,310 3,900 2 l 3 6.00 28.27 01/23/10 02/19/10 28 145,870 5,160 6 1 4 6.00 28.27 01/23/10 02/19/10 28 147,260 5,210 6 Average (28 days) 5,190 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fi concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Barry Cuble Reported To: Contractor: Lacy Construction Report Distribution: Reviewed By: (1) City of Coppell TX (1) City of Coppell TX (1) City of Coppell TX (2) Halff Assoc Inc (1) Lacy Construction (1) PacTrust Pacific Realty Associates LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1, 5.21 -09, Rev.3 Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091193.0089 Irerracon Service Date: 02/05/10 8901 Carpenter Frwy. Report Date: 02/22/10 Revision 1 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Southwestern Boulevard Coppell Road to Grapevine Creels Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Sample Date: 02/05/10 Sample Time: 1520 Sampled By: Barry Cuble Mix ID: DCSOHSO4 Weather Conditions: Sunny, light breeze Supplier: Redi -Mix Accumulative Yards: 16 Batch Size (cy): 8 Batch Time: 1421 Plant: 259 Placement Method: Direct Discharge Truck No.: 1321 Ticket No.: 25161676 Water Added Before (gal): 10 Water Added After (gal): 0 Field Test Data Sample Location: 5' S of edge, 5' E of W edge Test Result Specification Placement Location: Paving, W Bridge approach slab (27'x Slump (in): 3 3/4 3 -5 20') Air Content ( %): 5.1 3 -6 Concrete Temp. (F): 62 Ambient Temp. (F): 54 Plastic Unit Wt. (pcf): 147.1 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type I 1 6.00 28.27 02/06/10 02/12/10 7 128,430 4,540 4 1 2 6.00 28.27 02/06/10 02/19/10 14 146,980 5,200 6 l 3 6.00 28.27 02/06/10 03/05/10 28 1 4 6.00 28.27 02/06/10 03/05/10 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required fie samples. Terracon Rep.: Barry Cuble Started: 1130 Reported To: Finished: 1730 Contractor: Lacy Construction Report Distribution: (1) City of Coppell TX (1) City of Coppell TX Reviewed By: (1) City of Coppell TX (2) Hal FIT Assoc Inc (1) Lacy Construction (1) PacTnist Pacific Realty Associates LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM 0172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5- 21 -09, Rev.3 Page I of 1 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94091 194.0026 Service Date: 01/22/10 8901 Carpenter Frwy. Report Date: 02/22/10 Revision 2 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client PacT1 Pacific Realty Associates LP Attn: Matthew Oyen 15350 Southwest Sequoia Pkwy Ste 300 Portland, OR 97224 Project Southwestern Boulevard Grapevine Creek to Beltline Road Coppell, TX Project Number: 94091194 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1329 Plant: 3 Truck No.: 1 108 Ticket No.: 3273298 Field Test Data Test Slump (in): Air Content (' %,): Concrete Temp. (F): Ainbient Temp. (F): Plastic Unit Wt. (pel) Result Specification 4 1/2 4.0 74 69 144.5 Laboratory Test Data Set Specimen Diameter Area No. I D (in) (sq in) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Sample Date: 01/22/10 Sample Time: 1440 Sampled By: Francisco J. Morillo Weather Conditions: Clear Accumulative Yards: 6 Batch Size (cy): 6 Placement Method: Direct Discharge Water Added Before (gal):0 02/19/10 Water Added After (gal): 0 Sample Location: Inlet Tops at Sta 19 +43, Sta. 31 +66, Sta. 29 +50 and Sta. 3 +95 Placement Location: Inlets, Southwestern Blvd Date Date Received Tested 01/23/10 01/29/10 01/23/10 02/05/10 01/23/10 02/19/10 01/23/10 02/19/10 Age at Maximum Test Load (days) (lbs) 7 122,900 14 140,120 28 150,720 28 148,480 Average (28 days) Compressive Strength Fracture (psi) Type 4,350 2 4,960 2 5,330 4 5,250 2 5,290 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Francisco J. Morillo Started: 1400 Reported To: Finished: 1530 Contractor: Lacy Construction Report Distribution: (1) PacTrust Pacific Realty Associates LP (1) City of Coppell TX Reviewed By: (1) City of Coppell TX (2) Halff Assoc lac (1) Lacy ConsUOc6on Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. FROM 1.5- n- rri,tto'.i Page 1 of CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 194.0030 1 ie, a caLmn Service Date: 02/03/10 8901 Carpenter Frwy. Report Date: 02/22/10 Dallas, TX 75247 214 - 630 -1010 Reg No:F -3272 Client PacTrust Pacific Realty Associates LP Attn: Matthew Oyen 15350 SoutMvest Sequoia Pkwy Ste 300 Portland, OR 97224 Project Southwestern Boulevard Grapevine Creek to Beltline Road Coppell, TX Project Number: 94091194 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1253 Plant: 3 Truck No.: 5005 Ticket No.: 3273684 Field Test Data Test Slump (in): Air Content (' %o): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (Pei): Result Specification 3 1/2 4.0 60 47 145.0 Laboratory Test Data Set Specimen Diameter No. ID (in) 1 1 6.00 1 2 6.00 1 3 6.00 1 4 6.00 Sample Date: 02/03/10 Sample Time: 1415 Sampled By: Francisco J. Morillo Weather Conditions: Cloudy Accumulative Yards: 5.5 Batch Size (cy): 5 Placement Method: Direct Discharge Water Added Before (gal):0 7 Water Added After (gal): 0 Sample Location: Sta. 0 +43 Placement Location: Inlet; E Bound, SW Blvd. Age at Area Strength Fracture Test (sq in) Type 119,620 (days) 28.27 130,230 4,610 7 28.27 14 28.27 28 28.27 28 Date Received 02/04/10 02/04/10 02/04/10 02/04/10 Date Tested 02/10/10 02/17/10 03/03/10 03/03/10 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 119,620 4,230 6 130,230 4,610 2 Comments: Samples Made By: Tcrracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast samples. Terracon Rep.: Francisco J. Morillo Started: 1230 Reported To: Finished: 1500 Contractor: Lacy Construction Report Distribution: (I) PncTrusl Pacific Itc:diy As.ocioies LP (I) City orCoppell TX Reviewed By: (I) City orC'oppcll 1'X (2) Halff Assoc Inc Eric J. (I) Lncy Construction Senior Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ('ItIXNII. 3-2 I -IMI, 0.cr.3 Page 1 0l' CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091194.0032 111 reffMCIM Service Date: 02/05/10 8901 Carpenter Frwy. Report Date: 02/22/10 Revision 1 Dallas, TX 75247 214- 630 -1010 Reg No:F -3272 Client Project PacTrust Pacific Realty Associates LP Attn: Matthew Oyen 15350 Southwest Sequoia Pkwy Ste 300 Portland, OR 97224 Material Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1330 Plant: 07 Truck No.: 5030 Ticket No.: 7214568 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification T1 4.8 57 56 146.2 Southwestern Boulevard Grapevine Creek to Beltline Road Coppell, TX ect Number: 94091194 Sample Information Sample Date: 02/05/10 Sample Time: 1440 Sampled By: Mario A.Garcia Weather Conditions: Partly cloudy Accumulative Yards: 9 Batch Size (cy): 9 Placement Method: Bucket Water Added Before (gal): 10 Water Added After (gal): 0 Sample Location: See Placement Location Placement Location: Box Culvert, (2) at Sta. 10 +38 & Sta. 6.00 20 +00 Laboratory Test Data Strength Fracture (lbs) (psi) Type 124,310 Age at Set Specimen Diameter Area Date Date Test No. ID (in) (sq in) Received Tested (days) 1 1 6.00 28.27 02106110 02/12/10 7 1 2 6.00 28.27 02/06/10 02/19/10 14 1 3 6.00 28.27 02/06/10 03/05/10 28 1 4 6.00 28.27 02/06/10 03/05/10 28 Comments: Samples Made By: Terracon Maximum Compressive Load Strength Fracture (lbs) (psi) Type 124,310 4,400 4 153,390 5,430 2 Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and ca corn s samples. Terracon Rep.: Mario A.Garcia Started: 1300 Reported To: Finished: 1530 Contractor: Lacy Construction Report Distribution: (1) PacTrust Pacific Realty Associates LP (I) City of Coppell TX Reviewed By: (1) Cilc ol'Coppell TX (2) HalfT Assoc Inc I-Eric Clevel (1) Lacy Constniction Senior Project Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064 \ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. C'R0001, 5.21.09, Rev.3 Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94091 194.0038 Service Date: 02/15/10 8901 Carpenter Ftwy. Report Date: 02/22/10 Dallas, TX 75247 214 - 630 - 1 0 10 Reg No:F -3272 Client Project PacTrust Pacific Realty Associates LP Southwestern Boulevard Attn: Matthew Oyen Grapevine Creek to Beltline Road 15350 Southwest Sequoia Pkwy Ste 300 Coppell, TX Portland, OR 97224 Project Number: 94091194 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1357 Plant: 07 Truck No.: 7003 Ticket No.: 7214618 Field Test Data Test Slump (in): Air Content ('%1): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pef): Result Specification 3 1/4 3 -5 5.8 3 -6 50 40 145.9 Laboratory Test Data Set Specimen Diameter No. ID (ill) I 1 6.00 I 2 6.00 I 3 6.00 I 4 6.00 Sample Date: 02/15/10 Sample Time: 1530 Sampled By: Burl E. Thomas Weather Conditions: Clear Accumulative Yards: 4 Batch Size (cy): 4 Placement Method: Bucket Water Added Before (gal):0 Water Added After (gal): 0 Sample Location: Howell intersection Placement Location: Inlet top, Eastbound Southwestern Blvd. at S side Age at Area Date Date Test (sq in) Received Tested (days) 28.27 02/16/10 02/22/10 7 28.27 02/16/10 03/01/10 14 28.27 02/16/10 03/15/10 28 28.27 02/16/10 03/15/10 28 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 152,840 5,410 4 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locationq perform required field tZA samples. Terracon Rep.: Burl E. Thomas Started: 1300 Reported To: Finished: 1700 Contractor: Lacy Construction Report Distribution: Reviewed By: ( 1) PacTrusi1 Really Associates LP (1) City ol'Coppell TX (1) City orCnppcR TX (2) Hilff Assoc Inc Eric J. Cleveland, P.E. (1) Lacy Cuusrniction Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROW 1. 5_21.411). t(¢r.} Page I of I REPORT OF SOIL -LIME MIXTURE PULVERIZATION lierracon Consulting Engineers & Scientists 8901 Carpenter Frwy., Suite #100 Dallas, TX 75247 (214) 630-1010 Reg No.: F -3272 Date of Service: 02/22/10 Report No.: 94091194.0041 Project No.: 94091194 Client: PacTrust Pacific Realty Associates LP Project: Southwestern Boulevard 15350 Southwest Sequoia Pkwy Ste 300 Grapevine Creek to Beltline Road Portland, OR 97224 Coppell, TX Contractor: Lacy Construction Specification Requirements: Test Location: E Bound S Western Blvd. Minimum Passing 1 -3/4" Sieve: 100% Sta. 25 +00 - Sta. 35 +00 Minimum Passing #4 Sieve: 60% Sample Condition: Field Moist Test Method: NCTCOG TEST LOCATION 1 -3/4" SIEVE #4 SIEVE NO. % PASSING % PASSING 1 Sta. 25+50 100 58* 2 Sta. 27 +60 100 51* 3 Sta. 29+70 100 68 4 Sta. 32+00 100 70 5 Sta. 33+80 100 65 6 Sta. 34+60 100 75 7 RETEST OF TEST #1 - Sta. 25 +50 100 68 8 RETEST OF TEST #2 - Sta. 27 +60 • • 100 66 Comments: Technician: B. Thomas Report Distribution: (1) PacTrust Pacific Realty Associates LP (1) City of Coppell TX (1) City of Coppell TX (2) Halff Assoc Inc (1) Lacy Construction Eric J. Cleveland, P.:. • Senior Project Manager dgr This report is exclusively for the use of the client indicated above and shall not be reproduced in full without written approval of Terracon. •