ST0701-LR100223REINFORCING STEEL OBSERVATIONS REPORT Report Number: 94091193.0091 "Irerracon Service Date: 02/17/10 8901 Carpenter Frwy. Report Date: 02/23/10 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Southwestern Boulevard Attn: Keith Marvin Coppell Road to Grapevine Creels PO Box 9478 Coppell, TX Coppell, TX 75019 ect Number: 94091193 PROJECT DATA Drawings Utilized: Page SC1.3, dated May 2009 Locations /Items Observed: Rail Spans #1 & 2, South Side Test Method: Visual Observation ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type X Bar Grade X Properly Tied X Welded splices Reber Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover /Clearance X Discrepancies /Comments: No discrepancies were noted at the time of this observation. Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Burl E. Thomas Reported To: Contractor: Lacy Construction Report Distribution: (1) City nl'Coppeil 'I'X (1) City ulToppell TX (1) Lacy Constivction (1) City or Coppell TX (2) HalrrAssoc Inc (1) PacTrust Pacific Realty Associates LP Reviewed By: Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 rigr Eric J. Cleveland, Y.E. REINFORCING STEEL OBSERVATIONS REPORT Report Number: 94091193.0097 Irerracon Service Date: 02/19/10 8901 Carpenter Frwy. Report Date: 02/23/10 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Southwestern Boulevard Attn: Keith Marvin Coppell Road to Grapevine Creek PO Box 9478 Coppell, TX Coppell, TX 75019 ect Number: 94091193 PROJECT DATA Drawings Utilized: C411 Modification Locations /Items Observed: Bridge - Span #3 Rail Test Method: Visual Observation ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape �( Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Vapor Barrier Rebar Clean X Dowel Bars in Place X Welded Splices Trash & Debris Removed X Proper Bar Supports X Mechanical Splices Number of Bars X Proper Cover /Clearance X Lapped Splices X Discrepancies /Continents: No discrepancies were noted at the time of this observation. Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Barry Cuble Reported To: Contractor: Lacy Construction Report Distribution: (1) City nl'Coppcll '1'x (1) City ol'C'oppcll TX (1) Lacy C'unsh action (1) City of Coppell TX (2) Halff Assoc Inc Reviewed By: (1) PacTrust Pacific Realty Associates LP The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 Sa Senior Project Manager CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 194.0034 Irerracon Service Date: 02/09/10 8901 Carpenter Frwy. Report Date: 02/23/10 Revision 1 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project PacTrust Pacific Realty Associates LP Attn: Matthew Oyen 15350 Southwest Sequoia Pkwy Ste 300 Portland, OR 97224 Southwestern Boulevard Grapevine Creek to Beltline Road Coppell, TX Project Number: 94091194 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1429 Plant: 7 Truck No.: 7025 Ticket No.: 7214604 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pct): Result Specification 3 4.7 60 41 145.8 Sample Date: 02/09/10 Sample Time: 1508 Sampled By: Barry Cuble Weather Conditions: Partly sunny, light breeze Accumulative Yards: 7 Batch Size (cy): 7 Placement Method: Direct Discharge Water Added Before (gal):0 Test Water Added After (gal): 0 Sample Location: See Placement Location Placement Location: Inlet Walls and Bottoms at B /7, Sta. 1 1 31 +66; B /10, Sta. 28 +75 Laboratory Test Data Strength Fracture (lbs) (psi) Type 135,780 Age at Set Specimen Diameter 5,610 5 Area Date Date Test No. ID (in) (sq in) Received Tested (days) 1 1 6.00 28.27 02/10/10 02/16/10 7 1 2 6.00 28.27 02/10/10 02/23/10 14 1 3 6.00 28.27 02/10/10 03/09/10 28 1 4 6.00 28.27 02/10/10 03/09/10 28 Comments: Maximum Compressive Load Strength Fracture (lbs) (psi) Type 135,780 4,800 4 158,610 5,610 5 Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Barry Cuble Started: 1400 Reported To: Finished: 1600 Contractor: Lacy Construction Report Distribution: (I) PacTrust Pacific Realty Associates LP (I ) City of Coppell TX Reviewed By: (1) City of Coppell TX (2) Halff Assoc Inc (1) Lacy Consuitction Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1. 5-21-09, Rev.l Page I of I