Loading...
ST0702-LR090911CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94091 174.0016 Service Date: 09 /03/09 8901 Carpenter Frwy. Report Date: 09/11/09 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Sh 4,000 psi a 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1401 Plant: 07 Truck No.: 7003 Ticket No.: 7210005 Field Test Data Test Result Specification Slump (in): 3 1/4 Air Content ('Y,,): 4.3 Concrete Temp. (F): 95 Ambient Temp. (F): 86 Plastic Unit Wt. (pef): 149.5 Laboratory Test Data Set Specimen Diameter No. ID (in) I 1 6.00 I 2 6.00 I 3 6.00 1 4 6.00 mments: Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: Age at Area Date Date Test (sq in) Received Tested (days) 28.27 09/04/09 09/10/09 7 28.27 09/04/09 09/17/09 14 28.27 09/04/09 10/01/09 28 28.27 09/04/09 10/01/09 28 09/03/09 Sample Time: 1459 Juan Lopez Cloudy w /mild winds 8 Batch Size (ey): 8 Direct Discharge 5 0 N Wall, bottom half at Sta. 8 +81 Headwalls at Sta. 8 +81 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 130,800 4,630 4 Samples Made 13y: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required fie samples. Terracon Rep.: Juan Lopez Reported To: Contractor: .IRJ Paving Report Distribution: (1) city orcoppell'I'X (1) Freese and Nichols hic Reviewed By: (1) AU hwiuy 1.1' Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cuouni, - > i- r.lto-1 Page I of