ST0702-LR090911CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 94091 174.0016
Service Date: 09 /03/09 8901 Carpenter Frwy.
Report Date: 09/11/09 Dallas, TX 75247
214- 630 -1010 Reg No: F -3272
Client Project
City of Coppell TX
Coppell Road - #ST07 -02
Attn: Rick O'Dell
Bethel Road to
Engineering Dept
Southwestern Blvd.
PO Box 9478
Coppell, TX
Coppell, TX 75019
Project Number: 94091174
Material Information
Sample Information
Specified Sh 4,000 psi a 28 days
Mix ID: 1701
Supplier: Lattimore
Batch Time: 1401 Plant: 07
Truck No.: 7003 Ticket No.: 7210005
Field Test Data
Test
Result Specification
Slump (in):
3 1/4
Air Content ('Y,,):
4.3
Concrete Temp. (F):
95
Ambient Temp. (F):
86
Plastic Unit Wt. (pef): 149.5
Laboratory Test Data
Set Specimen
Diameter
No. ID
(in)
I 1
6.00
I 2
6.00
I 3
6.00
1 4
6.00
mments:
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
Age at
Area
Date
Date
Test
(sq in)
Received
Tested
(days)
28.27
09/04/09
09/10/09
7
28.27
09/04/09
09/17/09
14
28.27
09/04/09
10/01/09
28
28.27
09/04/09
10/01/09
28
09/03/09 Sample Time: 1459
Juan Lopez
Cloudy w /mild winds
8 Batch Size (ey): 8
Direct Discharge
5
0
N Wall, bottom half at Sta. 8 +81
Headwalls at Sta. 8 +81
Maximum
Compressive
Load
Strength Fracture
(lbs)
(psi) Type
130,800
4,630 4
Samples Made 13y: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required fie
samples.
Terracon Rep.: Juan Lopez
Reported To:
Contractor: .IRJ Paving
Report Distribution:
(1) city orcoppell'I'X (1) Freese and Nichols hic Reviewed By:
(1) AU hwiuy 1.1'
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
cuouni, - > i- r.lto-1 Page I of