Loading...
ST0702-LR090916CONCRETE COMPRESSIVE STRENGTH TEST REPORT "Irerracon Report Number: 94091 174.0018 28 days Sample Date: 09/08/09 Sample Time: Service Date: 09 /08/09 8901 Carpenter Frwy. Report Date: 09/16/09 Dallas, TX 75247 214 -630 -1010 ReQ No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, "rX 75019 Project Number: 94091 174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Sample Date: 09/08/09 Sample Time: 1500 Sampled By: Francisco J. Morillo Mix 1701 Weather Conditions: Clear i e Supplier: La ttim 01 C Accumulative Yards: 7.5 Batch Size (cy): 7.5 Batch Time: 1355 Plant: 3 Placement Method: Direct Discharge Truck No.: 7069 Ticket No.: 3269020 Water Added Before (gal): 0 Field Test Data Water Added After (gal): 0 Sample Location: Sta. 8 +81 Test Result Specification Placement Location: Inlet Q South Coppell Road Slump (in): 4 Air Content ( %6): 4.0 Concrete Temp. (F): 86 Ambient Temp. (F): 89 Plastic Unit Wt. (pcf): Laboratory Test Data Set Specimen Diameter Area Date Age at Maximum Compressive Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (Ibs) (psi) Type 1 1 6.00 28.27 09/09/09 09/15/09 7 123,170 4,360 5 1 2 6.00 28.27 09/09/09 09/22/09 14 1 -7 6.00 28.27 09/09/09 10/06/09 28 1 4 6.00 28.27 09/09/09 10/06/09 28 Comments: Not tested for plastic unit weight Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required fie samples. Terracon Rep.: Francisco J. Morillo Reported To: Contractor: .IR.I Paving Report Distribution: (1) City urcoppell 'I's (1) Freese and Nichols Inc Reviewed By: (1).111.1 Paving 1.1' Test Methods: ASTM C 31, ASTM C39, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. rnnnui, s- , � - uo. n—, Page I of Senior Project Manager CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091174.0013 Irerracon Service Date: 09/01/09 8901 Carpenter Frwy. Report Date: 09/16/09 Dallas, TX 75247 214- 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1428 Plant: 07 Truck No.: 3012 Ticket No.: 7209830 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pef) Result Specification 4 4.0 95 88 143.0 Laboratory Test Data Set Specimen Diameter No. ID (in) 1 I 6.00 1 2 6.00 1 3 6.00 1 4 6.00 Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: Age at Area Date Date Test (sq in) Received Tested (days) 28.27 09/02/09 09/08/09 7 28.27 09/02/09 09/15/09 14 28.27 09/02/09 09/29/09 28 28.27 09/02/09 09/29/09 28 09/01/09 Sample Time: 1515 Jesus Rojas Clear 8 Batch Size (cy): 8 Direct Discharge 0 0 Inlet walls Inlet walls at Sta. 19 +50 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 121,460 4,300 4 131,260 4,640 4 Uomments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required fie samples. Terracon Rep.: Jesus Rojas Reported To: Contractor: JRJ Paving Report Distribution: Reviewed B (1) City of Coppell TX (I) Freese and Nichols Inc y (1)JRJPaving LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propert ies of other apparently similar or identical materials. CROOOI, 5- 21 -09, Rev.J Page 1 of Senior Project Manager