Loading...
ST0702-LR090918CONCRETE COMPRESSIVE STRENGTH TEST REPORT err Report Number: 94091174.0006 Service Date: 08/20/09 8901 Carpenter Frwy. Report Date: 09/18/09 Dallas, TX 75247 214- 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091 174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1414 Plant: 3 Truck No.: 1049 Ticket No.: 3268211 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 4 3.8 95 92 146.4 Laboratory Test Data Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: Set Specimen Diameter Area Date Date No. ID (in) (sq in) Received Tested 1 1 6.00 28.27 08/22/09 08/27/09 1 2 6.00 28.27 08/22/09 09/03/09 1 3 6.00 28.27 08/22/09 09/17/09 1 4 6.00 28.27 08/22/09 09/17/09 08/20/09 Sample Time: 1503 James C. Blackwell Clear 8 Batch Size (cy): 8 Direct Discharge 0 0 See Placement Location Inlet bottom @ Sta. 16 +05 and 6' manhole Age at Maximum Compressive Test Load Strength Fracture (days) (Ibs) (psi) Type 7 116,300 4,110 4 14 125,410 4,440 4 28 146,420 5,180 2 28 142,020 5,020 2 Average (28 days) 5,100 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Teri-aeon Services: Obtain samples of fresh concrete at the placement locations, perform required fie samples. Terracon Rep.: James C. Blackwell Started: 1300 Reported To: Contractor: JRJ Paving Report Distribution: (1) City of Coppell TX (1)1RJ Paving LP (1) Freese and Nichols Inc Finished: 1600 Reviewed By: Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1. 5- 21 -09, Rev.3 Page I of I