ST0702-LR090924CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94091174.0019 Irerracon
Service Date: 09/09/09 8901 Carpenter Frwy.
Report Date: 09/24/09 Dallas, TX 75247
214 - 630 -1010 Reg No:F -3272
Client Project
City of Coppell TX
Coppell Road - #ST07 -02
Attn: Rick O'Dell
Bethel Road to
Engineering Dept
Southwestern Blvd.
PO Box 9478
Coppell, TX
Coppell, TX 75019
Project Number: 94091174
Material Information
Sample Information
Specified Strength: 4,000 psi @ 28 days
Mix ID: 1701
Supplier: Lattimore
Batch Time: 1436 Plant: 3
Truck No.: 5034 Ticket No.: 3269123
Field Test Data
Test
Result Specification
Slump (in):
4
Air Content ( %):
4.5
Concrete Temp. (F):
89
Ambient Temp. (F):
92
Plastic Unit Wt. (pef):
Laboratory Test Data
Set Specimen
Diameter
No. ID
(in)
1 1
6.00
1 2
6.00
1 3
6.00
1 4
6.00
Area
Date
(lbs)
Test
(sq in)
Received
Tested
(days)
28.27
09/10/09
7
28.27
09/10/09
14
28.27
09/10/09
28
28.27
09/10/09
28
09/09/09 Sample Time: 1530
Francisco J. Morillo
Clear
8 Batch Size (ey): 8
Direct Discharge
0
5
Sta. 8 +64
Inlet at Coppell Rd.
Maximum Compressive
Load
Strength Fracture
(lbs)
(psi) Type
131,530
4,650 4
145,420
5,140 2
Comments: Not tested for plastic unit weight.
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive trer
samples.
Terracon Rep.: Francisco J. Morillo Started: 1300
Reported To: Finished: 1600
Contractor: JRJ Paving
Report Distribution:
(1) Cily of Coppell TX (1) Freese and Nichols Inc Reviewed By:
(1) JRJ Paving LP E c leveland, P.E.
Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
Age at
Date
09/ 16/09
09/23/09
10/07/09
10/07/09
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s)
referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CRODOI, 5- 21 -09, Rev.3 Page 1 of
CONCRETE COMPRESSIVE STRENGTH TEST REPORT err
Report Number: 94091174.0009
Service Date: 08/26/09 8901 Carpenter Frwy.
Report Date: 09/24/09 Dallas, TX 75247
214 - 630 -1010 Reg No:F -3272
Client Project
City of Coppell TX
Coppell Road - #ST07 -02
Attn: Rick O'Dell
Bethel Road to
Engineering Dept
Southwestern Blvd.
PO Box 9478
Coppell, TX
Coppell, TX 75019
Project Number: 94091174
Material Information
Sample Information
Specified Strength: 4,000 psi @ 28 days
Mix ID: 1707
Supplier: Lattimore
Batch Time: 1403 Plant: 3
Truck No.: 1063 Ticket No.: 3268507
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
08/26/09 Sample Time: 1504
Christopher P. Moran
Sunny
10 Batch Size (cy): 10
Direct Discharge
0
0
Headwall
Headwall S side of railroad, E & W
side; inlet @ Sta. 8 +79 and manhole @
Sta. 67 +81
Field Test Data
Test
Slump (in):
Air Content ( %):
Concrete Temp. (F):
Ambient Temp. (F):
Plastic Unit Wt. (pef):
Result Specification
4
3.6
99
96
147.2
Laboratory Test Data
Set Specimen
Diameter
Area
Date
No. ID
(in)
(sq in)
Received
1 1
6.00
28.27
08/27/09
1 2
6.00
28.27
08/27/09
1 3
6.00
28.27
08/27/09
1 4
6.00
28.27
08/27/09
Age at Maximum Compressive
Date
Test
Load
Strength
Fracture
Tested
(days)
(lbs)
(psi)
Type
09/02/09
7
117,980
4,170
4
09/09/09
14
128,650
4,550
4
09/23/09
28
139,670
4,940
4
09/23/09
28
148,880
5,270
4
Average (28 days)
5,110
Comments: Average compressive strength of 28 day cylinders complies with the specified strength.
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and ca co pre sive ength
samples.
Terracon Rep.: Christopher P. Moran
Reported To:
Contractor: JRJ Paving
Report Distribution:
(1) City of Coppell TX (1) Freese and Nichols Inc Reviewed By:
(t)JRJPaving LP Eric Y. Cleveland, P.E.
Seni r Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM 0138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CR0001, 5- 21 -09, R-3 Page 1 of 1