Loading...
ST0702-LR090925CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94091 174.0021 Service Date: 09/10/09 8901 Carpenter Frwy. Report Date: 09/25/09 Dallas, TX 75247 214 -630 -1010 Reg No:F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Ric[( O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Sample Date: 09/10/09 Sample Time: 1545 Sampled By: Francisco J. Morillo Mix ID: 1701 Weather Conditions: Clear Supplier: Lattimore Accumulative Yards: 7.5 Batch Size (cy): 7.5 Batch Time: 1452 Plant: 3 Placement Method: Direct Discharge Truck No.: 7069 Ticket No.: 3269242 Water Added Before (gal): 0 Water Added After (gal) 0 Field Test Data Sample Location: Sta. 16 +15 Test Result Specification Placement Location: Inlet ct Copell Rd., S bound Slump (in): 4 Air Content 4.5 Concrete Temp. (F): 90 Ambient Temp. (F): 94 Plastic Unit Wt. (pcf): Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 09/11/09 09/17/09 7 114,320 4,040 2 1 2 6.00 28.27 09/11/09 09/24/09 14 126,210 4,460 4 I 3 6.00 28.27 09/11/09 10/08/09 28 1 4 6.00 28.27 09/11/09 10/08/09 28 Comments: Not tested for plastic unit weight. Samples Made By: Terracon Services: Ohlain samples of fresh concrete at the placement locationsi perform required field tests and cast compressive strength samples. Terracon Rep.: Francisco .l. Morillo Started: 1400 Reported To: Superintendent Finished: 1630 Contractor: .IR.I Paving Report Distribution: (1) Cily of Coppcll'I'N (1) Frcose and Nichols Inc Reviewed By : (I),IR.I1 1.1' Eric J. Cleveland, P.E. Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cH0001. i21419, u�•�.: Page I of I