ST0702-LR091003CONCRETE COMPRESSIVE STRENGTH TEST REPORT
RM PM
Report Number: 94091 174.0029 1 re Im Is m ca% Cc 1 n
Service Date: 09 /24/09 8901 Carpenter Frwy.
Report Date: 10/03/09 Dallas, TX 75247
214- 630 -1010 Reg No: F -3272
Client Project
City of Coppell TX
Coppell Road - #ST07 -02
Attn: Rick O'Dell
Bethel Road to
Engineering., Dept
Southwestern Blvd.
PO Box 9478
Coppell, TX
Coppell, TX 75019
Project Number: 94091174
Material Information
Sample Information
Specified Strength: 4,000 psi @ 28 days
Sample Date:
09/24/09 Sample Time: 1520
Sampled By:
Francisco J. Morillo
Mix ID: 1701
Weather Conditions:
Cloudy
Supplier: Lattimore
Accumulative Yards:
2.5 Batch Size (cy): 2.5
Batch Time: 1358 Plant:
6
Placement Method:
Direct Discharge
Truck No.: 7059 Ticket No.:
6359422
Water Added Before (gal):0
Water Added After (gal):
0
Field Test Data
Sample Location:
Sta. 1 +97
Test Result
Specification
Placement Location:
Inlet Q S. Coppell Rd, S bound
Slump (in): 3 1/2
Air Content (' %1): 4.0
Concrete Temp. (F): 79
Ambient Temp. (F): 71
Plastic Unit Wt. (pcl):
Laboratory Test Data
Age at
Maximum Compressive
Set Specimen Diameter Area
Date
Date Test
Load Strength Fracture
No. ID (in) (sq in)
Received
Tested (days)
(Ibs) (psi) Type
1 1 6.00 28.27
09/25/09
10/01/09 7
119,110 4,210 4
1 2 6.00 28.27
09/25/09
10/08/09 14
1 3 6.00 28.27
09/25/09
10/22/09 28
1 4 6.00 28.27
09/25/09
10/22/09 28
Comments: Not tested for plastic unit weight.
Samples Made Ry: Terracon
Services: Obtain samples of fresh concrete at the placement location4 perform required field tests and cast co . pressiv strength
samples.
Terracon Rep.: Francisco .I. Morillo Started: 1430
Reported To: Finished: 1700
Contractor: .Ilt.l Paving
Report Distribution
())City of Coppell Tx (1) Freese and Nichols Inc Reviewed By:
(1),IRa Paving 1.1' Eric J Cleveland, P.E.
Seni e Project Manager
Test Methods: ASTM C 31, ASTM 09, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Ilr.�.i Page 1 of 1
('111111111, i :I•ni,
CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94091 174.0025 Irel I CJU.Lin
Service Date: 09/18/09 8901 Carpenter Frwy.
Report Date: 10/03/09 Dallas, TX 75247
214- 630 -1010 Reg No: F -3272
Client Project
City of Coppell TX Coppell Road - #ST07 -02
Attn: Rick O'Dell Bethel Road to
Engineering Dept Southwestern Blvd.
PO Box 9475 Coppell, TX
Coppell, TX 75019 Project Number: 94091 174
Material Information Sample Information
Specified Strength: 4,000 psi a 28 days
Sample Date:
09/18/09 Sample Time:
1540
Sampled By:
Ashton L. Varnell
Mix ID: 1701
Weather Conditions:
Cloudy, windy
Supplier: I_,attimore
Accumulative Yards:
2.25 Batch Size (cy):
2.25
Batch Time: 1453 Plant:
3
Placement Method:
Direct Discharge
Truck No.: 3034 Ticket No.:
3269347
Water Added Before (gal): 10
Water Added After (gal):
0
Field Test Data
Sample Location:
See Placement Location
Tcst Result
Specification
Placement Location:
Inlet Top, 815 Coppell Rd
Slump (in): 3
Air Content ( %,): 3.0
Concrete Temp. (F): 89
Ambient Temp. (F): 85
Plastic Unit Wt. (pcf): 151.2
Laboratory Test Data
Age at
Maximum Compressive
Set Specimen Diameter Area
Date
Date Test
Load Strength
Fracture
No. ID (in) (sq in)
Received
Tested (days)
(lbs) (psi)
Type
1 1 6.00 28.27
09/19/09
09/25/09 7
114,520 4,050
5
I ? 6.00 28.27
09/19/09
10/02/09 14
I 3 6.00 28.27
09/19/09
10/16/09 28
1 4 6.00 28.27
09/19/09
10/16/09 28
Comments:
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast com ressive strength
samples.
Terracon Rep.: Ashton L. Varnell Started: 1400
Reported To: Finished: 1600
Contractor: .IR.I Paving
Report Distribution:
(1) City nrCoppc117x (1) Freese mid Nichols Inc Reviewed By:
t1 >.1RJ Pavin 1.11 Eric 1/Cleveland, P.E.
Seniot Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C 143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CHOW .1 -09, ne,.3 Page 1 of