Loading...
ST0702-LR091006CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94091174.0018 Service Date: 09/08/09 8901 Carpenter Frwy. Report Date: 10/06/09 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd, PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1355 Plant: 3 Truck No.: 7069 Ticket No.: 3269020 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pct): Result Specification 4.0 86 89 Laboratory Test Data Set Specimen Diameter Area Date No. ID (in (sq in) Received 1 1 6.00 28.27 09/09/09 1 2 6.00 28.27 09/09/09 1 3 6.00 28.27 09/09/09 1 4 6.00 28.27 09/09/09 Sample Date: 09/08/09 Sample Time: 1500 Sampled By: Francisco J. Morillo Weather Conditions: Clear Accumulative Yards: 7.5 Batch Size (cy): 7.5 Placement Method: Direct Discharge Water Added Before (gal):0 Water Added After (gal): 0 Sample Location: Sta. 8 +81 Placement Location: Inlet @ South Coppell Road Age at Maximum Compressive Date Test Load Strength Fracture Tested (days) (lbs) (psi) Type 09/15/09 7 123,170 4,360 5 09/22/09 14 143,910 5,090 2 10/06/09 28 157,140 5,560 4 10/06/09 28 161,900 5,730 4 Average (28 days) 5,650 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Not tested for plastic unit weight. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compre i strength samples. / %/% Terracon Rep.: Francisco J. Morillo ,, Reported To: Contractor: JRJ Paving Report Distribution: (1) City of Coppell TX (1) Freese and Nichols Inc Reviewed By: /// /Z/ (1) JRJ Paving LP Eric J. Cleveland, P.E. Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5- 21 -09, Rev.J Page I of I