Loading...
ST0702-LR091009CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091174.0029 Irerracon Service Date: 09/24/09 8901 Carpenter Frwy. Report Date: 10/09/09 Dallas, TX 75247 214- 630 -1010 Rep- No: F -3272 Client Project City of Coppel I TX Attn: Ricl( O'Dell Engineering Dept PO Box 9478 Coppell, TX 75019 Material Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1358 Plant: 6 Truck No.: 7059 Ticket No.: 6359422 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pct): Result Specification f - 1/2 4.0 79 71 Laboratory Test Data Coppell Road - #ST07 -02 Bethel Road to Southwestern Blvd. Coppell, TX Proiect Number: 94091174 Sample Information Sample Date: 09/24/09 Sample Time: Sampled By: Francisco J. Morillo Weather Conditions: Cloudy Accumulative Yards: 2.5 Batch Size (cy): Placement Method: Direct Discharge Water Added Before (gal):0 6.00 Water Added After (gal): 0 Sample Location: Sta. 1 +97 Placement Location: Inlet @ S. Coppell Rd, S bound Set Specimen Diameter Area Date Date No. ID (in) (sq in) Received Tested 1 1 6.00 28.27 09/25/09 10/01/09 1 2 6.00 28.27 09/25/09 10/08/09 1 3 6.00 28.27 09/25/09 10/22/09 1 4 6.00 28.27 09/25/09 10/22/09 Age at Maximum Compressive 1520 2.5 Test Load Strength Fracture (days) (lbs) (psi) Type 7 119,110 4,210 4 14 129,790 4,590 4 28 28 Comments: Not tested for plastic unit weight. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and ca t com ss' a er samples. Terracon Rep.: Francisco J. Morillo Started: 1430 Reported To: Finished: 1700 Contractor: JRJ Paving Report Distribution: (1) City of Coppell TX (1) Freese and Nichols Inc Reviewed By: (1) JRJ Paving LP V. . leveland, P.E. Senior roject Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5.21.09, R-3 Page I of I CONCRETE COMPRESSIVE STRENGTH TEST REPORT err Report Number: 94091174.0021 Service Date: 09/10/09 8901 Carpenter Frwy. Report Date: 10/09/09 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1452 Plant: 3 Truck No.: 7069 Ticket No.: 3269242 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 4 4.5 90 94 Laboratory Test Data Set Specimen Diameter Area Date No. ID (in) (sq in) Received 1 1 6.00 28.27 09/11/09 1 2 6.00 28.27 09/11/09 1 3 6.00 28.27 09/11/09 1 4 6.00 28.27 09/11/09 Sample Date: 09/10/09 Sample Time: 1545 Sampled By: Francisco J. Morillo Weather Conditions: Clear Accumulative Yards: 7.5 Batch Size (cy): 7.5 Placement Method: Direct Discharge Water Added Before (gal):0 Water Added After (gal): 0 Sample Location: Sta. 16 +15 Placement Location: Inlet @ Copell Rd., S bound Age at Maximum Compressive Date Test Load Strength Fracture Tested (days) (lbs) (psi) Type 09/17/09 7 114,320 4,040 2 09/24/09 14 126,210 4,460 4 10/08/09 28 135,310 4,790 4 10/08/09 28 142,310 5,030 2 Average (28 days) 4,910 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Not tested for plastic unit weight. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. r Terracon Rep.: Francisco J. Morillo Started: 1400 Reported To: Superintendent Finished: 1630 Contractor: JRJ Paving Report Distribution: Reviewed B (1) City of Coppell TX (1) Freese and Nichols Inc y (1) JRJ Paving LP E J. leveland, P.E. Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cR0001, 5-21-09, Rm3 Page I of I