Loading...
ST0702-LR091012C ONCRETE C STRENGTH TEST REPORT EM am Diameter No. ID (in) I 1 6.00 Service Date: 10/02/09 8901 Carpenter Frwy. Report Date: 10/12/09 Dallas, TX 75247 I 4 214 -630 -1010 Re No:F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9475 Coppell, TX Coppell, TX 75019 Project Number: 94091 174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 0951 Plant: 3 Truck No.: 7069 Ticket No.: 3269862 Field Test Data Test Slump (in): Air Content (' %,): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcl): Result Specification 2 1/2 4.5 84 78 144.5 Laboratory Test Data Set Specimen Diameter No. ID (in) I 1 6.00 I 2 6.00 1 3 6.00 I 4 6.00 Sample Date: 10/02/09 Sample Time: 1 100 Sampled By: Francisco J. Morillo Weather Conditions: Clear Accumulative Yards: 9 Batch Size (cy): 9 Placement Method: Direct Discharge Water Added Before (gal):0 Water Added After (gal): 0 Sample Location: See Placement Location Placement Location: Manholes - Sewer Line A a Sta. 5 +00 28.27 & Sta. 5 +13 Age at Area Date Date Test (sq in) Received Tested (days) 28.27 1 0/03/09 10/09/09 7 28.27 1 0/03/09 10/16/09 14 28.27 1 0/03/09 10/30/09 28 28.27 10/03/09 10/30/09 28 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 117,220 4,150 2 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement location$ perform required field tests and cast compressive samples. i Terracon Rep.: Francisco J. Morillo Started: 0900 Reported To: City Inspector Finished: 1200 Contractor: .IRJ Paving Report Distribution: (1) Cily of Coppell'I'x (1) Frcese and Nichols Inc Reviewed By : (1).111.1 Paving 1.11 r1C.t_ P - VP.IAIIl� Senior Koject Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. c•naual. 5- 21- 09.1eo3 Page I of I