Loading...
ST0702-LR091030CONCRETE COMPRESSIVE STRENGTH TEST REPORT a;0 WE Report Number: 94091174.0033 flerracan Service Date: 10/02/09 8901 Carpenter Frwy. Report Date: 10/30/09 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 0951 Plant: 3 Truck No.: 7069 Ticket No.: 3269862 Field Test Data Test Slump (in): Air Content Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (Pei): Result Specification 2 1/2 4.5 84 78 144.5 Laboratory Test Data Set Specimen Diameter Area Date No. ID (in) (sq in) Received 1 1 6.00 28.27 10/03/09 1 2 6.00 28.27 10/03/09 1 3 6.00 28.27 10/03/09 1 4 6.00 28.27 10/03/09 Sample Information Sample Date: 10/02/09 Sample Time: 1100 Sampled By: Francisco J. Morillo Weather Conditions: Clear Accumulative Yards: 9 Batch Size (cy): 9 Placement Method: Direct Discharge Water Added Before (gal):0 117,220 Water Added After (gal): 0 Sample Location: See Placement Location Placement Location: Manholes - Sewer Line A @ Sta. 5 +00 & Sta. 5 +13 Compressive Age at Maximum Date Test Load Tested (days) (lbs) 10/09/09 7 117,220 10/16/09 14 132,130 10/30/09 28 154,450 10/30/09 28 138,240 Average (28 days) Compressive Strength Fracture (psi) Type 4,150 2 4,670 4 5,460 2 4,890 2 5,180 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Francisco J. Morillo Started: 0900 Reported To: City Inspector Finished: 1200 Contractor: M Paving Report Distribution: Z///W (1) City of Coppell TX (1) Freese and Nichols Inc Reviewed By: ri Cleveland, P.E. (1)JRJPaving LP Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5.21.09, Rev.3 Page 1 of 1