ST0702-LR091117CONCRETE COMPRESSIVE STRENGTH TEST REPORT Ir e rracon Sample Date: Report Number: 94091 174.0037 1 145 Sampled By: Robert Alegria Mix ID: 1701 Service Date: 1 1/04/09 Weather Conditions: 8901 Carpenter Frwy. Report Date: 1 1/17/09 Supplier: Laltimore Dallas, TX 75247 Accumulative Yards: 6 Batch Size (cy): 214 -630 -1010 Reg No: F -3272 Client Project Placement Method: City of Coppell TX Coppell Road - #ST07 -02 Truck No.: 1 120 Ticket No.: Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Sample Date: 11/04/09 Sample Time: 1 145 Sampled By: Robert Alegria Mix ID: 1701 Weather Conditions: Clear Supplier: Laltimore Accumulative Yards: 6 Batch Size (cy): 6 Batch Time: 1038 Plant: 6 Placement Method: Direct Discharge Truck No.: 1 120 Ticket No.: 6361411 Water Added Before (gal):5 Water Added After (gal): 0 Field Test Data Sample Location: Manhole @ Sta. 11 +50 Test Result Specification Placement Location: Manhole @ Sta. 11 +50; Inlet Walls & Slump (in): 3 Bottom @ Sta. 1 +97 Air Content ( %,): 3.3 Concrete Temp. (F): 80 Ambient Temp. (F): 67 Plastic Unit NN/l. (pcl): 150.0 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 11/05/09 11/11/09 7 106,490 3,770 4 1 2 6.00 28.27 11/05/09 11 / 18/09 14 1 3 6.00 28.27 11/05/09 12/02/09 28 1 4 6.00 28.27 11/05/09 12/02/09 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement location$ perform required field tests and cast compressive strength samples. Terracon Rep.: Robert Alegria Started: 1000 Reported To: Alfredo, Longhorn Finished: 1245 Contractor: .1 R.1 Paving Report Distribution: (1) City o1'CoppelI rx (1) Freese and Nichols Inc Reviewed By: (1) JR.1 Pavin 1.1' Er' Cleveland, P.E. Senior( Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ('101001, i-21-111). K�,.1 Page I of I