Loading...
ST0702-LR091230CONCRETE COMPRESSIVE STRENGTH TEST REPORT Ireirracon Report Number: 94091 174.0065 Service Date: 12/22/09 8901 Carpenter Frwy. Report Date: 12/30/09 Dallas, TX 75247 214- 630 -1010 Re No:F -3272 Client Project City of Coppell TX Coppell Road - 4ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi n 28 days Sample Date: 12/22/09 Sample Time: 1345 Sampled By: Mario A.Garcia Mix ID: 1701 Weather Conditions: Cloudy, strong breezes Supplier: Lattimore Accumulative Yards: 6 Batch Size (cy): 6 Batch Time: 1228 Plant: 3 Placement Method: Bucket Truck No.: 9141 Ticket No.: 3272344 Water Added Before (gal): 10 Field Test Data Water Added After (gal): 0 Sample Location: Sta. 2 +20 Test Result Specification Placement Location: Flume, E of Coppell Road and S of Slump (in): 4 1/2 3 -5 Burns Street, from Sta. 1 +00 to Sta. Air Content ( %,): 5.0 3 -6 2 +40 Concrete Temp. (F): 67 Ambient Temp. (F): 65 Plastic Unit Wt. (pcf): 142.1 Laboratory Test Data Set Specimen Diameter Area Date Age at Date Test Maximum Compressive Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 12/23/09 12/29/09 7 111,720 3,950 6 1 2 6.00 28.27 12/23/09 01/05/10 14 1 3 6.00 28.27 12/23/09 01/19/10 28 1 4 6.00 28.27 12/23/09 01/19/10 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Mario A.Garcia Started: 1130 Reported To: Finished: 1500 Contractor: JR.1 Paving Report Distribution: (1)CilyorCoppcll'I'x (1) Freese and Nichols 111C Reviewed By: (I) JRJ Paving LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CWe01, 5.21 -10), lt Page 1 of I CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091174.0053 Terracon Truck No.: 3012 Service Date: 12/15/09 8901 Carpenter Frwy. Report Date: 12/30/09 Revision 1 Dallas, TX 75247 Placement Method: 214- 630 -1010 Re No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1348 Plant: 3 Truck No.: 3012 Ticket No.: 3272013 Field Test Data 10 Batch Size (cy): 10 Placement Method: Test Result Specification Slump (in): 3 3/4 3 -5 Air Content ( %): 5.0 3 -6 Concrete Temp. (F): 55 I 1 6.00 Ambient Temp. (F): 44 12/22/09 Plastic Unit Wt. (pcf): 143.5 28.27 Sample Date: 12/15/09 Sample Time: Sampled By: Burl E. Thomas Weather Conditions: Clear Accumulative Yards: 10 Batch Size (cy): 10 Placement Method: Bucket Water Added Before (gal):5 Water Added After (gal): 5 Slump After (in): 4.25 Sample Location: Sta. 7 +50 Placement Location: V -Line Flume at Sta. 8 +00 to Sta. 7 +00 Laboratory Test Data Strength Fracture (lbs) (psi) Type 136,560 4,830 4 145,680 5,150 2 Age at Set Specimen Diameter Area Date Date Test No. ID (in) (sq in) Received Tested (days) I 1 6.00 28.27 12/16/09 12/22/09 7 1 2 6.00 28.27 12/16/09 12/29/09 14 1 3 6.00 28.27 12/16/09 01/12/10 28 I 4 6.00 28.27 12/16/09 01/12/10 28 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 136,560 4,830 4 145,680 5,150 2 Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Burl E. Thomas Reported To: Contractor: JRJ Paving Report Distribution: (1) City ofCoppell TX (1) Freese and Nichols Inc Reviewed By: (1) JRJ Paving LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5- 21 -09, Rm3 Page I of 1