Loading...
ST0702-LR091224CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94091 174.0055 Service Date: 12/16/09 8901 Carpenter Frwy. Report Date: 12/24/09 Dallas, TX 75247 214- 630 -1010 Reg No•F -3272 Client Project City of Coppel I TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Debt Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi n 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1342 Plant: 6 Truck No.: 9127 Ticicet No.: 6363421 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 41/2 3 -5 5.1 3 -6 60 46 141.2 Sample Date: 12/16/09 Sample Time: 1448 Sampled By: Mario A.Garcia Weather Conditions: Cloudy, Breezy Accumulative Yards: 10 Batch Size (cy): 10 Placement Method: Bucket Water Added Before (gal): 10 Water Added After (gal): 0 Sample Location: Sta. 6 +75 Placement Location: Flume East of Coppell Road at Sta. Test 6 +00 to 7 +00 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 12/17/09 12/23/09 7 134,110 4,740 2 1 2 6.00 28.27 12/17/09 12/30/09 14 1 3 6.00 28.27 12/17/09 01/13/10 28 1 4 6.00 28.27 12/17/09 01 /13/10 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement location$ perform required field tests and cast compressiv strength samples. Terracon Rep.: Mario A.Garcia Started: 1230 Reported To: Finished: 1600 Contractor: JRJ Paving Report Distribution: (1) City of coppelI Tx (1) Freese and Nichols hic Reviewed By: (1) JRJ Pavin u' Eric J. Cleveland . Senior Project Manag Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cewsrl. 5- 21 -u1), R-3 Page I of I