ST0702-LR100105CONCRETE COMPRESSIVE STRENGTH TEST REPORT RM Report Number: 94091174.0065 lerracon Service Date: 12/22/09 8901 Carpenter Frwy. Report Datc: 01105110 Revision 1 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1228 Plant: 3 Truck No.: 9141 Ticket No.: 3272344 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 4 1/2 3 -5 5.0 3 -6 67 65 142.1 Laboratory Test Data Set Specimen Diameter No. ID (in) 1 1 6.00 1 2 6.00 1 3 6.00 1 4 6.00 Sample Date: 12/22/09 Sample Time: 1345 Sampled By: Mario A.Garcia Weather Conditions: Cloudy, strong breezes Accumulative Yards: 6 Batch Size (cy): 6 Placement Method: Bucket Water Added Before (gal): 10 Water Added After (gal): 0 Sample Location: Sta. 2 +20 Placement Location: Flume, E of Coppell Road and S of 01/19/10 Burns Street, from Sta. 1 +00 to Sta. 28.27 2 +40 Age at Area Date Date Test (sq in) Received Tested (days) 28.27 12/23/09 12/29/09 7 28.27 12/23/09 01105110 14 28.27 12/23/09 01/19/10 28 28.27 12/23/09 01/19/10 28 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 111,720 3,950 6 125,620 4,440 4 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Mario A.Garcia Started: 1130 Reported To: Finished: 1500 Contractor: JRJ Paving Report Distribution: (1) City of Coppell TX (1) Freese and Nichols Inc Reviewed By: (1) JRJ Paving LP ric J. Cleve nd, P.E. Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5- 21 -09, Rev.3 Page 1 of 1