ST0702-LR100111CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091174.0048 Ifierracon Service Date: 12/14/09 8901 Carpenter Frwy. Report Date: 01/11/10 Revision 2 Dallas, TX 75247 214 - 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1120 Plant: 6 Truck No.: 2668 Ticket No.: 636325 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification T 3 -5 4.7 3 -6 68 58 145.9 Laboratory Test Data Set Specimen Diameter Area Date No. ID (in) (sq in) Received 1 1 6.00 28.27 12/15/09 1 2 6.00 28.27 12/15/09 1 3 6.00 28.27 12/15/09 1 4 6.00 28.27 12/15/09 Sample Date: 12/14/09 Sample Time: 1230 Sampled By: Burl E. Thomas Weather Conditions: Partly cloudy Accumulative Yards: 6 Batch Size (cy): 6 Placement Method: Bucket Water Added Before (gal): 10 Water Added After (gal): 0 Sample Location: Sta. 8 +25 Placement Location: V -Line Channel at Sta. 8 +00 to Sta. 01/11/10 8 +75 Compressive Age at Maximum Date Test Load Tested (days) (lbs) 12/21/09 7 136,400 12/28/09 14 150,290 01/11/10 28 173,410 01/11/10 28 176,100 Average (28 days) Compressive Strength Fracture (psi) Type 4,820 2 5,320 2 6,130 4 6,230 4 6,180 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast c mpres ive strength samples. Terracon Rep.: Burl E. Thomas Started: 1100 Reported To: Finished: 1330 Contractor: JRJ Paving Report Distribution: (1) City of Coppell TX (1) Freese and Nichols Inc Reviewed By: (1) M Paving LP Eric J. leveland, P.E. Senior roject Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001. 5.21 -09, Rev.3 Page 1 of 1