ST0701-LR090929FI E o LD DENSI 9 YOc TEST O R
Service Date: 09/23/09 8901 Carpenter Frwy.
Report Date: 09/29/09 Dallas, TX 75247
214- 630 -1010 Rep- No: F -3272
Client Project
City of Coppell TX
Attn: Keith Marvin
PO Boa 9478
Coppell, TX 75019
Southwestern Boulevard
Coppell Road to Grapevine Creek
Coppell, TX
Field Test Data
Test
No. Test L ocation
Probe Wet Water Water Dry Unit Percent
Lift / Mat. Depth Density Content Content Weight Compaction
Elev. No. (in) (pef) (pcf) ( %) (pcf) ( % t)
Storm Sewer manhole, Line A, Sta. 0 +64
Project Number: 94091193
Material Information
Lab Test Data
Project Requirements
1 Sta. 0 -1 -64, S side
Optimum Max. Lab
6
121.4
22.0
Water Dry Unit
Water
Minimum
Mat. Proctor
Laboratory Content Weight
Content
Compaction
No. Ref. No. Classification and Description
Test Method ( %) (Pcf)
( %)
(%)
1 94091 193.0002 Dark brown clay, with sand
ASTM D698 24.2 94.6
0/ +4
95
Field Test Data
Test
No. Test L ocation
Probe Wet Water Water Dry Unit Percent
Lift / Mat. Depth Density Content Content Weight Compaction
Elev. No. (in) (pef) (pcf) ( %) (pcf) ( % t)
Storm Sewer manhole, Line A, Sta. 0 +64
1 Sta. 0 -1 -64, S side
7.5' bfg 1
6
121.4
22.0
22.1 *
99.4
105
2 Sta. 0 +64, W side
7.5' bfg 1
6
122.7
22.0
21.8 *
100.7
106
3 Sta. 0 +64, E side
8.5' bfg 1
6
121.2
21.8
21.9 *
99.4
105
4 RETEST OF TEST #I - Sta.
7.5' bfg 1
6
120.4
26.5
28.2
93.9
99
0 +64, S side
5 RETEST OF TEST #2 - Sta.
7.5' bfg 1
6
120.5
26.0
27.5
94.5
100
0 +64, W side
6 RETEST OF TEST #3 - Sta.
8' bfg 1
6
118.4
25.6
27.6
92.8
98
0 +64, E side
Datum: bfg = below final grade Gauge ID: 1960
Comments: An asterisk ( *) appears next to the test results which do not meet the project requirements as noted above.
Services: Perform in -place density and moisture content tests to determine degree of compactbn and material moisture
condition.
Terracon D- Cit e Started: 0900
Reported To: Eloy - Lacy Construction Finished: 1500
Contractor: Lacy Construction
Report Distribution:
(1) City ol'Cuppell Tx (1) City of Coppell TX Reviewed By:
(1) City ol'Cbplxll 'I'x (2) Hniff Assoc Inc
(1) Lacy Construction (1) PncTntst Pacific Realty Associates LP
Test Methods: ASTM D6938
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
('wuuq..t- ;o.uo. Rr,.2 Page I of I