Loading...
ST0701-LR090921CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 193.0003 Irerracon Service Date: 09/04/09 8901 Carpenter Frwy. Report Date: 09/21/09 Dallas, TX 75247 214- 630 -1010 Reg No:F -3272 Client City of Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Project Southwestern Boulevard Coppell Road to Grapevine Creek Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1333 Plant: 3 Truck No.: 9141 Ticket No.: 3268975 Field Test Data Test Result Slump (in): 3 Air Content ( %): 3.8 Concrete Temp. (F): 85 Ambient Temp. (F): 87 Plastic Unit Wt. (pcf): 148.0 Specification Laboratory Test Data Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: Set Specimen Diameter Area Date Date No. ID (in) (sq in) Received Tested 1 1 6.00 28.27 09/05/09 09/11/09 1 2 6.00 28.27 09/05/09 09/18/09 1 3 6.00 28.27 09/05/09 10/02/09 1 4 6.00 28.27 09/05/09 10/02/09 09/04/09 Sample Time: 1445 Mario A.Garcia Cloudy 10 Batch Size (cy): 10 Direct Discharge 0 0 See Placement Location Manhole walls @ E bound Southwestern Blvd, Sta. 0 +64, Line A Age at Maximum Compressive Test Load Strength Fracture (days) (lbs) (psi) Type 7 122,990 4,350 4 14 132,630 4,690 4 28 28 t- omments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and c st samples. Terracon Rep.: Mario A.Garcia Reported To: Contractor: Lacy Construction Report Distribution: Reviewed B (1) City of Coppell TX (1) City of Coppell TX y: (1) City of Coppell TX (2) Halff Assoc Inc E c J (1) Lacy Constriction (1) PacTrust Pacific Realty Associates LP Senior ive strength Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. C110001, 5.21 -09, Rm]l Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 193.0005 Irerracon Service Date: 09/09/09 8901 Carpenter Frwy. Report Date: 09/21/09 Dallas, TX 75247 214- 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Southwestern Boulevard Attn: Keith Marvin Coppell Road to Grapevine Creek PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091 193 Material Information Sample Information Specified Strength: 4,000 psi rr 28 days Sample Date: 09/09/09 Sample Time: 1530 Sampled By: Jesus Rojas Mix ID: 1 701 Weather Conditions: Partly cloudy Supplier: Lattimore Accumulative Yards: 7.5 Batch Size.(cy): 7.5 Batch Time: 1444 Plant: 3 Placement Method: Direct Discharge Truck No.: 9141 Ticket No.: 3269124 Water Added Before (gal): 0 Field Test Data Water Added After (gal): 0 Sample Location: See Placement Location Test Result Specification Placement Location: Inlets @ Sta. 7 +00 & Sta. 3 +82 Slump (in): 3 1/2 Air Content (' %,): 4.0 Concrete Temp. (F): 96 Ambient Temp. (F): 85 Plastic Unit Wt. (pef): 140.1 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 09/11/09 09/16/09 7 140,260 4,960 2 1 2 6.00 28.27 09/11/09 09/23/09 14 1 3 6.00 28.27 09/11/09 10/07/09 28 1 4 6.00 28.27 09/11/09 10/07/09 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast compressive strength samples. Terracon Rep.: Jesus Rojas Started: 1300 Reported To: Finished: 1700 Contractor: Lacy Construction Report Distribution: (1) Cily of Coppell 'rX (1) Cily or Coppell TX Reviewed By: (1) City ,I Cuppcll 'IX (2) 1lalIT Assoc tic (1) Lacy Cunsuvcdim (1) PacTrust Pacific Really Associales LP Test Methods: ASTM C 31, ASTM 09, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ltnnu 1. s -'_ l - nn. R-3 Page 1 01 1