Loading...
ST0701-LR091005CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94091193.0003 Service Date: 09/04/09 8901 Carpenter Frwy. Report Date: 10/05/09 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client City of Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Project Southwestern Boulevard Coppell Road to Grapevine Creek Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1333 Plant: 3 Truck No.: 9141 Ticket No.: 3268975 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 3 3.8 85 87 148.0 Laboratory Test Data Set Specimen Diameter Area Date No. ID (in) (sq in) Received 1 1 6.00 28.27 09/05/09 1 2 6.00 28.27 09/05/09 1 3 6.00 28.27 09/05/09 1 4 6.00 28.27 09/05/09 Sample Date: 09/04/09 Sample Time: 1445 Sampled By: Mario A.Garcia Weather Conditions: Cloudy Accumulative Yards: 10 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):0 Water Added After (gal): 0 Sample Location: See Placement Location Placement Location: Manhole walls @ E bound 28 Southwestern Blvd, Sta. 0 +64, Line A Compressive Age at Maximum Date Test Load Tested (days) (lbs) 09/11/09 7 122,990 09/18/09 14 132,630 10/02/09 28 153,140 10/02/09 28 149,820 Average (28 days) Compressive Strength Fracture (psi) Type 4,350 4 4,690 4 5,420 4 5,300 4 5,360 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive s n samples. Terracon Rep.: Mario A.Garcia Reported To: Contractor: Lacy Construction Report Distribution: (1) City of Coppell TX (1) City of Coppell TX Reviewed By: (1) City of Coppell TX (2) Halff Assoc Inc ric eveland, P.E. (1) Lacy Conslniction (1) PacTrust Pacific Realty Associates LP Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5- 21 -09, Rev.7 Page I of 1