Loading...
ST0701-LR091029CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 193.0018 Irerracan Service Date: 10/20/09 8901 Carpenter Frwy. Report Date: 10/29/09 Dallas, TX 75247 214 -630 -1010 Reg No: F -3272 Client Project City of Coppell TX Attn: Keith Malvin PO Box 9478 Coppell, TX 75019 Southwestern Boulevard Coppell Road to Grapevine Creek Coppell, TX Project Number: 94091 193 Material Information Sample Information Specified Strength: 3,600 psi @ 28 days Sample Date: 10/20/09 Sample Time: 1803 Sampled By: Juan Lopez Mix ID: DCCOG501 Weather Conditions: Clear Supplier: Itedi -Mix Accumulative Yards: 8 Batch Size (cy): 8 Batch Time: 0435 Plant: 136 Placement Method: Direct Discharge Truck No.: 1 166 Ticket No.: 25128549 Water Added Before (gal): 10 Field Test Data Water Added After (gal): 0 Sample Location: Pier n B.2 /C Test Result Specification Placement Location: Drilled Pers, see Foundation Slump (in): 6 5 -7 Observations Report #94091193.00 17, Air Content ('Yo): 1.5 dated 10/20/09, for pier locations Concrete Temp. (F): 81 Ambient Temp. (F): 80 Plastic Unit Wt. (pcf): 151.0 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 10/21/09 10/27/09 7 135,190 4,780 4 1 2 6.00 28.27 10/21/09 11/03/09 14 1 3 6.00 28.27 10/21/09 11/17/09 28 1 4 6.00 28.27 10/21/09 11/17/09 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast compressive strengt samples. Terracon Rep.: Juan Lopez Reported To: Contractor: Lacy Construction Report Distribution: (1) City of Coppell IN (1) Cily of Coppell TX Reviewed By: (1)CilyofCoppell'IX (2) 1-Iaff'Assoelne Erie J. velan ,P. E. (1) Lacy Collstl'uelit'll (1) PacTrust Pacific Really Associates LP Senior Project M nager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. I Roue 1. 5- ]1 -u11. R,, .; Page I of' I