ST0701-LR091110CONCRETE COMPRESSIVE STRENGTH TEST REPORT am on
Report Number: 94091 193.0023 Ilerracon
Service Date: 11/02/09 8901 Carpenter Frwy.
Report Date: 11/10/09 Dallas, TX 75247
214 - 630 -1010 Reg No: F -3272
Client Project
City of Coppell TX Southwestern Boulevard
Attn: Keith Marvin Coppell Road to Grapevine Creek
PO Box 9478 Coppell, TX
Coppell, TX 75019
Project Number: 94091193
Material Information Sample Information
Specified Strength: 3,600 psi tr 28 days
Mix ID: DCCOG501
Supplier: Redi -Mix
Batch Time: 1233 Plant: P136
Track No.: 1 193 Ticket No.: 25131182
Field Test Data
Test
Slump (in):
Air Content (' %o):
Concrete Temp. (F):
Ambient Temp. (F):
Plastic Unit Wt. (pct):
Result Specification
6 5 -7
1.4
79
74
148.7
Laboratory Test Data
Set Specimen
Diameter
Area
Date
No. ID
(in)
(sq in)
Received
1 I
6.00
28.27
11/03/09
1 2
6.00
28.27
11/03/09
1 3
6.00
28.27
11/03/09
1 4
6.00
28.27
11/03/09
Sample Date: 11/02/09 Sample Time: 1325
Sampled By: Juan Lopez
Weather Conditions: Sunny
Accumulative Yards: 4 Batch Size (cy): 4
Placement Method: Direct Discharge
Water Added Before (gal):3
Water Added After (gal): 0
Sample Location: Drilled Piers, A #1 /D
Placement Location: Drilled Piers at A #1 /C & A #1 /D
Maximum
Age at
Date
Test
Tested
(days)
11/09/09
7
11/16/09
14
11/30/09
28
11/30/09
28
Maximum
Compressive
Load
Strength Fracture
(lbs)
(psi) Type
115,050
4,070 4
Comments:
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement location$ perform required field tests and cast compressive strength
samples.
Terracon Rep.: .Juan Lopez
Reported To:
Contractor: Lacy Construction
Report Distribution:
(1) City of C'oppcl I 'I'X
(1) City of Coppell 'fX
(1) Lacy C'onslruc6on
(1) City of Coppell TX Reviewed By:
(2) Half Assoc Inc
(1) PncTnist Pncilic Renhy Associntes LP
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively forthe use of the client
Indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
UJUKH) 1, t -2140. Ito J Page t of i