ST0701-LR091208FIELD DENSITY TEST REPORT
am MW
'1 2 1erracon
Report Number: 94091 194.0009
Service Date: 12/01/09
8901 Carpenter Frwy.
Report Date: 12/08/09
Dallas, TX 75247
214 -630 -1010
Reg No: F -3272
Client
Project
PacTrust Pacific Realty Associates LP
Southwestern Boulevard
Attn: Matthew Oyen
Grapevine
Creek to Beltline Road
15350 Southwest Sequoia Pkwy Ste 300
Coppell, TX
Portland, OR 97224
Project Number: 94091194
Material Information
Lab Test Data
Project Requirements
Optimum Max. Lab
Water Dry Unit
Water
Minimum
Mat. Proctor
Laboratory
Content Weight
Content
Compaction
No. Ref. No. Classification and Description
Test Method
( %) (pcf)
( %)
( %)
1 94091 193.0002 Dark brown clay, with sand
ASTM D698
24.2 94.6
0/ +4
95
2 94091 193.0009 Dark brown clay, with sand &
ASTM D698
19.9 105.1
0/ +4
95
gravel
Field Test Data
Probe Wet
Water Water
Dry Unit
Percent
Test
Lift / Mat.
Depth Density
Content Content
Weight
Compaction
No. Test Location
Elev. No.
(in) (pef)
(pef) ( %)
(pef)
( %)
Storm Sewer Line, Line A East
10 Sta. 1+09
2' bfg 2
6 121.2
20.6 20.5
100.6
96
11 Sta. 2 +30
1' bfg 2
6 119.6
20.0 20.1
99.6
95
12 Sta. 4 +94
2' bfg 2
6 121.4
22.0 22.1
99.4
95
Water Line, Line A East
13 Sta. I0 +68
2.5' bfg 1
6 115.5
22.9 24.7
92.6
98
14 Sta. 11+87
1.5' bfg 1
6 120.1
26.4 28.2
93.7
99
15 Sta. 13 +60
P bfg 1
6 123.5
25.9 26.5
97.6
103
Datum: bfg = below final grade Gauge ID: 1960
Comments: Test results on this report meet project requirements as noted above.
Services: Perform in -place density and moisture content tests to determine degree of compaction and mabrial moisture
condition.
Terracon Rep.: Barry Cuble Started: 1300
Reported To: Oscar, Lacy Construction Finished: 1500
Contractor: Lacy Construction
Report Distribution:
(I) PacTrusi Pacific Realty Associates LP (1) City of Coppell TX Reviewed By:
(I) City of Cappcll - I - X (2) Halff Assoc Inc Eric J. Cleveland, .E.
(I) Lacy Construction Senior Project Manager
Test Methods: ASTM D6938
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
(AMP, 4- 30-00, It".2 Page 1 of I