ST0701-LR091210CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94091193.0035 Ire rroca n
Service Date: 11/11/09 8901 Carpenter Frwy.
Report Date: 12/10/09 Revision 2 Dallas, TX 75247
214- 630 -1010 Reg No: F -3272
Client Project
City of Coppell TX Southwestern Boulevard
Attn: Keith Marvin Coppell Road to Grapevine Creels
PO Box 9478 Coppell, TX
Coppell, TX 75019
ect Number: 94091193
Material Information
Specified Strength: 3,600 psi @ 28 days
Mix ID:
DCCOG504
Supplier:
Redi -Mix
Batch Time:
0925 Plant: P136
Truck No.:
1189 Ticket No.: 25135874
Field Test Data
Test
Slump (in):
Air Content ( %):
Concrete Temp. (F):
Ambient Temp. (F):
Plastic Unit Wt. (pcf):
Sample Information
Sample Date:
11/11/09 Sample Time:
Sampled By:
Michael W. Whyman
Weather Conditions:
Partly cloudy
Accumulative Yards:
8.5 Batch Size (cy):
Placement Method:
Direct Discharge
Water Added Before (gal):0
Date
Water Added After (gal):
0
Sample Location:
See Placement Location
Placement Location:
Bridge Abutment, eastbound #1
li1� [.,
8.5
Result Specification
4 3/4 3 -5
5.0 3 -6
76
59
146.0
Laboratory Test Data
Age at
Maximum
Compressive
Set Specimen Diameter
Area
Date
Date
Test
Load
Strength
Fracture
No. ID (in)
(sq in)
Received
Tested
(days)
(lbs)
(psi)
Type
1 1 6.00
28.27
11/12/09
11/18/09
7
113,070
4,000
2
1 2 6.00
28.27
11/12/09
11/25/09
14
125,420
4,440
4
1 3 6.00
28.27
11/12/09
12/09/09
28
154,460
5,460
2
1 4 6.00
28.27
11/12/09
12/09/09
28
142,260
5,030
2
Average (28 days)
5,250
Comments: Average compressive strength of 28 day cylinders complies with the specified strength.
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast com res ive strength
samples.
Terracon Rep.: Michael W. Whyman Started: 0930
Reported To: Finished: 1130
Contractor: Lacy Construction
Report Distribution:
(1) City of Coppell TX (1) City of Coppell TX Reviewed By:
(1) City of Coppell TX (2) Halff Assoc Inc Eric J. leveland, P.E.
(1) Lacy Construction (1) PacTrust Pacific Realty Associates LP Senior P jest Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CR0001, 5- 21 -09, Rm3 Page 1 of 1
CONCRETE COMPRESSIVE STRENGTH TEST REPORT c
I�r Report Number: 94091193.0046 I� �I VG
Service Date: 11/25/09 8901 Carpenter Frwy.
Report Date: 12/10/09 Revision 1 Dallas, TX 75247
214- 630 -1010 Reg No: F -3272
Client
City of Coppell TX
Attn: Keith Marvin
PO Box 9478
Coppell, TX 75019
Project
Southwestern Boulevard
Coppell Road to Grapevine Creek
Coppell, TX
Project Number: 94091193
Material Information Sample Information
Specified Strength: 3,600 psi @ 28 days
Mix ID: DCCOG504
Supplier: Redi -Mix
Batch Time: 1113 Plant: 259
Truck No.: 1289 Ticket No.: 25141961
Field Test Data
Test
Slump (in):
Air Content ( %):
Concrete Temp. (F):
Ambient Temp. (F):
Plastic Unit Wt. (pcf):
Result Specification
4
4.9
70
66
144.6
Laboratory Test Data
Set
Specimen
Diameter
No.
ID
(in)
1
1
6.00
1
2
6.00
1
3
6.00
1
4
6.00
Sample Date:
11/25/09 Sample Time: 1157
Sampled By:
Michael W. Whyman
Weather Conditions:
Clear, light wind
Accumulative Yards:
10 Batch Size (cy): 10
Placement Method:
Bucket
Water Added Before (gal):0
7
Water Added After (gal):
0
Sample Location:
Bent #2
Placement Location:
Bent Cap, Bents #2 & #3
Age at
Area
Date
Date
Test
(sq in)
Received
Tested
(days)
28.27
11/27/09
12/02/09
7
28.27
11/27/09
12/09/09
14
28.27
11/27/09
12/23/09
28
28.27
11/27/09
12/23/09
28
Maximum Compressive
Load
Strength Fracture
(lbs)
(psi) Type
111,140
3,930 4
122,690
4,340 2
Comments:
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Michael W. Whyman Started: 1030
Reported To: Finished: 1300
Contractor: Lacy Construction
Report Distribution:
(1) City of Coppell TX (1) City of Coppell TX Reviewed By:
(1) City of Coppell TX (2) Halff Assoc Inc Eric J. Cleve! , P.E.
(1) Lacy Construction (1) PacTrust Pacific Realty Associates LP Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CR0001, 5- 21 -09, ReO Page 1 of 1