Loading...
ST0701-LR091222CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94091 193.0051 Service Date: 12/1 1/09 8901 Carpenter Frwy. Report Date: 12/22/09 Dallas, TX 75247 214- 630 -1010 Reg No:F -3272 Client City of Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Project Southwestern Boulevard Coppell Road to Grapevine Creek Coppell, TX Project Number: 94091193 Material Information Specified Strength: 3,600 psi @ 28 days Mix ID: DCB00501 Supplier: Itedi -Mix Batch Time: 0957 Truck No.: 1257 Plant: 259 Ticket No.: 25145068 Field Test Data Test Slump (in): Air Content Concrete Tem p. (1 7 ): Ambient Temp. (1 7 ): Plastic Unit Wt. (pct): Result Specification 2 1/2 3 -5 2.4 3 -6 55 41 148.3 Laboratory Test Data Set Specimen Diameter No. ID (in) 1 1 6.00 1 2 6.00 1 3 6.00 1 4 6.00 Sample Information Sample Date: 12/11/09 Sample Time: 1100 Sampled By: Burl E. Thomas Weather Conditions: Cloudy Accumulative Yards: 10 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):5 Water Added After (gal): 0 Sample Location: 6'S & 6'W of NE corner Placement Location: Riprap, E side, Southwestern Blvd 12/12/09 eastbound Age at Area Date Date Test (sq in) Received Tested (days) 28.27 12/12/09 12/18/09 7 28.27 12/12/09 12/25/09 14 28.27 12/12/09 01/08/10 28 28.27 12/12/09 01/08/10 28 Maximum Compressive Load Strength Fracture (lbs) (psi) Type 113,760 4,020 4 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast compressive strength samples. Terracon Rep.: Burl E. Thomas Started: 0830 Reported To: Finished: 1230 Contractor: Lacy Construction Report Distribution: (1) City nl'C'nppell 'rX (1) City of Coppell TX Reviewed By: (1) City ul'C'oppell'I;\ (2) Hal n' Assoc Inc Eric J. Cley, land, P.E. (1) Lacy Construction (1) PacTrust Pacific Realty Associates LP Senior PrqJect Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. (A W" c._i.mi. Rev.z Page I of I