Loading...
ST0701-LR100108CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091193.0050 Irerracan Service Date: 12/10/09 8901 Carpenter Frwy. Report Date: 01/08/10 Revision 1 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client City of Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Project Southwestern Boulevard Coppell Road to Grapevine Creek Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 3,600 psi @ 28 days Mix ID: DCB00501 Supplier: Redi -Mix Batch Time: 1207 Plant: 259 Truck No.: 1371 Ticket No.: 25144642 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf) Laboratory Test Data Result Specification 2 1/4 3 -5 3.0 3 -6 55 35 147.5 Set Specimen Diameter Area Date No. ID (in) (sq in) Received 1 1 6.00 28.27 12/11/09 1 2 6.00 28.27 12/11/09 1 3 6.00 28.27 12/11/09 1 4 6.00 28.27 12/11/09 Sample Date: 12/10/09 Sample Time: 1320 Sampled By: Burl E. Thomas Weather Conditions: Clear Accumulative Yards: 10 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):5 Water Added After (gal): 0 Sample Location: 6' S & 6'E of NW corner Placement Location: Riprap, W side, eastbound Southwestern Boulevard Age at Maximum Compressive Date Test Load Strength Fracture Tested (days) (lbs) (psi) Type 12/17/09 7 105,530 3,730 4 12/24/09 14 124,510 4,400 4 01/07/10 28 154,830 5,480 2 01/07/10 28 149,880 5,300 2 Average (28 days) 5,390 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required fie samples. Teri Rep.: Burl E. Thomas Started: 0830 Reported To: Finished: 1330 Contractor: Lacy Construction Report Distribution: (1) City of Coppell TX (1) City of Coppell TX (1) Lacy Conslniction Test Methods (1) City of Coppell TX Reviewed By: (2) Halff Assoc Inc (1) PacTrust Pacific Realty Associates LP ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5- 21 -09, Rm3 Page I of 1 Senior Project Manager CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091193.0051 Irerracon Service Date: 12/11/09 8901 Carpenter Frwy. Report Date: 01/08/10 Revision 1 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Southwestern Boulevard Attn: Keith Marvin Coppell Road to Grapevine Creek PO Box 9478 Coppell, TX Coppell, TX 75019 ect Number: 94091193 Material Information Specified Strength: 3,600 psi @ 28 days Mix ID: DCB00501 Supplier: Redi -Mix Batch Time: 0957 Plant: 259 Truck No.: 1257 Ticket No.: 25145068 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 2 1/2 3 -5 2.4 3 -6 55 41 148.3 Sample Information Sample Date: 12/11/09 Sample Time: 1100 Sampled By: Burl E. Thomas Weather Conditions: Cloudy Accumulative Yards: 10 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):5 Date Water Added After (gal): 0 Sample Location: 6'S & 6'W of NE corner Placement Location: Riprap, E side, Southwestern Blvd Received eastbound Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 12/12/09 12/18/09 7 113,760 4,020 4 1 2 6.00 28.27 12/12/09 12/25/09 14 130,200 4,610 2 1 3 6.00 28.27 12/12/09 01/08/10 28 163,200 5,770 4 1 4 6.00 28.27 12/12/09 01/08/10 28 146,820 5,190 5 Average (28 days) 5,480 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Burl E. Thomas Started: 0830 Reported To: Finished: 1230 Contractor: Lacy Construction Report Distribution: (1) City of Coppell TX (1) City ofCoppellTX Reviewed By: (1) City of Coppell TX (2) Halff Assoc Inc (1) Lacy Construction (1) PacTrust Pacific Realty Associates LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 5- 21 -09, Rm3 Page 1 of 1