Loading...
Denton Creek NH-LR091130Alva ENGINEERING& T L.P. Serving The Geo- Industry Since 1974 1 1 15 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790 -1910 • FAX: (972) 790 -0967 Geotechnicat Materials S ��- Failure Testing Invesligatior Environmental CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT CLIENT: SCI Construction, LTD STANDARD 6" X 12" 5467 New Copeland Rd. AREA 28.27 SQ. IN. Tyler, TX 75703 REPORT DATE: 11/30/09 PROJECT: Pro. Denton Creek Nursing Home SAMPLE DATE: 10/28/09 1410 E. Sandy Lake Rd. Coppell, TX PROJECT NO.: 108TX5K9 ATTN: Brandon Parker REPORT NO.: 31 SE &T TECHNICIAN: Dusty McClendon LOCATION OF PLACEMENT: Slab for Electric Transformer IPAGE 1 OF 1 TEST DATA MATERIALS /SUPPLIER DATA Time Arrived: 2:45 PM Concrete Supplier: Cow Town Time Left: 4:15 PM Ticket #: 528450 Slump (Inches): 4.5 Truck #: 915 Concrete Temperature (F): 64 Time Batched: 2:41 PM % Air Content: N/A Time Sampled: 3:40 PM Total No. of Test Cylinders Made: 4 Product Code: 245 -0 Total Cubic Yards Placed: 10 Cement: N/A Added Water: 30 Gallons Fly Ash: N/A Weather Conditions: Cloudy Coarse A gregate: N/A Air Temperature (F): 68 Water: N/A Unit Weigh of Fresh Concrete: 149 % Air Content : N/A Specimen Age Date Unit Wt. Total Load Compressive Type of Strength Required Number Days Tested pcf Lbs. Strength psi Fracture psi/days 1A. 1 7 1 11/4/09 1 81,nno 2864 Single Shear 3000/28 1B 14 11/11/09 149 94,000 3324 Single Shear 3000/28 1C 28 11/25/09 149 124,000 4385 Single Shear 3000/28 1D 28 11/25/09 149 122,000 4314 Single Shear 3000/28 Curing ASTM C -31 Test Method Cylinders Made By: Cylinders Tested By Slump ASTM C -143 JASTM C -39 & 231 SE &T SE &T Remarks: Tested concrete meets /exceeds required strength. Very Truly Yours, M�eSaint,' ab Manager & Vice President Texas Firm Registration No: 61893 Texas Professional Firm Registration No: F- 001587 This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This report only applies to the samples tested and does not necessarily represent identical or similar samples. G: /2009 /108tx5k9 /Cpistr /CPISTR31 /SA