Loading...
ST0701-LR100226CONCRETE COMPRESSIVE STRENGTH TEST REPORT 3 �rra c an Report Number: 94091 193.0095 Service Date: 02/18/10 8901 Carpenter Frwy. Report Date: 02/26/10 Dallas, TX 75247 214- 630 -1010 Reg No: F - 3272 Client Project City ol'Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Southwestern Boulevard Coppell Road to Grapevine Creels Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Sample Date: 02/18/10 Sample Time: 1440 Sampled By: Francisco J. Morillo Mix ID: DCCOG504 Weather Conditions: Clear Supplier Redi -Mix Accumulative Yards: 5 Batch Size (cy): 5 Batch Time: 1335 Plant: 259 Placement Method: Direct Discharge Truck No.: 1028 Ticket No.: 25164077 Water Added Before (gal):0 Water Added After (gal): 0 Field Test Data Sample Location: Approximately 50'W of E end Test Result Specification Placement Location: Bridge Guard Rail Wall, south side Slump (in): 3 1/2 3 -5 Air Content (' %o): 4.0 3 -6 Concrete Temp. (P): 74 Ambient "Temp. (F): 68 Plastic Unit Wt. (pct): 146.0 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. 1 D (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 02/19/10 02/25/10 7 119,620 4,230 4 1 2 6.00 28.27 02/19/10 03/04/10 14 1 3 6.00 28.27 02/19/10 03/18/10 28 1 4 6.00 28.27 02/19/10 03/18/10 28 Comments: Samples Made 13y: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Francisco .1. Morillo Started: 1330 Reported To: Superintendent Finished: 1630 Contractor: Lacy Construction Report Distribution: Reviewed By: (1) City of ('oppell 'iX (1) City of Coppell TX ( I ) City of C'o mell 'fx (2) Hallf Assoc Inc (1) Lacy Construction (1) PacTrust Pacific Realty Associates LP Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I o1' I CONCRETE COMPRESSIVE STRENGTH TEST REPORT Me Report Number: 94091 193.0098 rra con 7 Service Date: 02/19/10 8901 Carpenter Frwy. Report Date: 02/26/10 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Southwestern Boulevard Coppell Road to Grapevine Creek Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: DCCOG504 Supplier: Redi -Mix Batch Time: 1434 Truck No.: 1 184 Plant: 136 Ticket No. 25164735 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pct): Result Specification 5 1/4 3 -5 5.2 3 -6 60 47 148.6 Laboratory Test Data Sample Date: 02/19/10 Sample Time: Sampled By: Barry Cuble Weather Conditions: Overcast, breezy Accumulative Yards: 5 Batch Size (cy): Placement Method: Direct Discharge Water Added Before (gal):0 6.00 Water Added After (gal): 0 Sample Location: See Placement Location Placement Location: Bridge Span #3 Rail Set Specimen Diameter Area Date Date No. ID (in) I (sq in) Received Tested 1 1 6.00 28.27 02/20/10 02/26/10 1 2 6.00 28.27 02/20/10 03/05/10 1 3 6.00 28.27 02/20/10 03/19/10 1 4 6.00 28.27 02/20/10 03/19/10 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 130,640 4,620 14 28 28 1513 G Fracture Type Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement location4 perform required field tests and cast compressive samples. , Terracon Rep.: Barry Cuble Started: 1230 / , '/ /// Reported To: Finished: 1600 Contractor: Lacy Construction Report Distribution: (1) City of Coppell Tx (1) City of Coppell TX Reviewed B y : (1) City of Coppell Tx (2) Halff Assoc Inc (1) Lacy C'onstrucl ion (1) PacTnist Pacific Realty Associates LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR000 s_ - uo. Rev.; Page 1 of I Senior Project Manager