ST0003-LR090611(6/15/2009) Carol bye - 94081163 -5.pdf Page 1 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94081 163.0100 Sample Date: Service Date: 05/13/09 1215 8901 Carpenter Frwy, Ste 100 Report Date: 06/11/09 Dallas, TX 75247 Sampled By: Francisco J. 214 - 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Coppell Road - #ST00 -03 Weather Conditions: Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX 30 Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 3,000 psi @ 28 days Sample Date: 05/13/09 Sample Time: 1215 Sampled By: Francisco J. Morillo Mix ID: 8272 Weather Conditions: Cloudy Supplier: TXf Accumulative Yards: 30 Batch Size (cy): 10 Batch Time: 1 112 Plant: 131 Placement Method: Direct Discharge Truck No.: 1 102 Ticket No.: 864809 Water Added Before (gal): 0 Water Added After (gal): 0 Field Test Data Sample Location: From corner to 75'N Test Result Specification Placement Location: Sidewalk at Oak Grove Ln Slump (in): 6 1/2 Air Content ( %): 3.5 Concrete Temp. (F): 78 Ambient Temp. (F): 72 Plastic Unit Wt. (pcf): 146.5 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type I 1 6.00 28.27 05/14/09 05/20/09 7 91,440 3,230 2 1 2 6.00 28.27 05/14/09 06/10/09 28 127,710 4,520 2 1 3 6.00 28.27 05/14/09 06/10/09 28 129,050 4,560 2 Average (28 days) 4,540 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and samples. Terracon Rep.: Francisco J. Morillo Started: 1130 Reported To: Contractor: Tiseo Report Distribution: (1) City of Coppell TX (1) Tiseo Paving Company Test Methods: (1) Huilt Zollars Inc strength Project Manager ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 Finished: 1330 Reviewed By: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT lest methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. C11000 1.5- 21- 09,R1v3 Page 1 of I