Loading...
ST0003-LR090519CONCRETE COMPRESSIVE STRENGTH TEST REPORT ME OR Report Number: 94081163.0092 flerracon Service Date: 04/20/09 8901 Carpenter Frwy, Ste 100 Report Date: 05/19/09 Dallas, TX 75247 214 - 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Coppell Road - #ST00 -03 Attn: Albert Samaniego Sandy Lake Road to Engineering Dept Cooper Lane PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94081163 Material Information Sample Information Specified Strength: 4,000 psi n 28 days Mix ID: 2501H Supplier: Tiseo Paving Batch Time: 0727 Plant: Truck No.: 165 Ticket No.: Field Test Data Test Result Slump (in): 5 Air Content ( %): 7.0 Concrete Temp. (F): 82 Ambient Temp. (F): 60 Plastic Unit Wt. (pcf): 147.0 Laboratory Test Data Specification Set Specimen Diameter Area Date No. ID (in) (sq in) Received 1 1 6.00 28.27 04/21/09 1 2 6.00 28.27 04/21/09 1 3 6.00 28.27 04/21/09 Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: 04/20/09 Sample Time: 0815 Ashton L. Varnell Clear 10 Batch Size (cy): 10 Direct Discharge 15 Leaveout at Halifax Pavement, north middle lane, two leaveouts in front of school; westbound approaches at Halifax and Oak Grove Age at Maximum Compressive Date Test Load Strength Fracture Tested (days) (lbs) (psi) Type 04/27/09 7 128,820 4,560 2 05/18/09 28 159,030 5,630 2 05/18/09 28 158,000 5,590 4 Average (28 days) 5,610 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Ashton L. Varnell Started: 0630 Reported To: Contractor: Tiseo Report Distribution: (1) City of Coppell TX (1) Tiseo Paving Company (1) Huitt Zollars Inc Finished: 1000 Reviewed By: Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Cn0001, 4- 30-09, Rev.2 Page 1 of 1