ST0003-LR090501CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94081 163.0095 Irerracon
Service Date: 04/22/09 8901 Carpenter Frwy, Ste 100
Report Date: 05/01/09 Dallas, TX 75247
214 -630 -1010 RegNo:F -3272
Client Project
City of Coppel I TX Coppell Road - #ST00 -03
Attn: Albert Samaniego Sandy Lake Road to
Engineering Dept Cooper Lane
PO Box 9478 Coppell, TX
Coppell, TX 75019 Project Number: 94081163
Material Information
Specified Strength: 4,000 psi a 28 days
Mix ID: 25011 -1
Supplier: Tiseo Paving
Batch Time: 0657 Plant:
Truck No.: 164 Ticket No.:
Field Test Data
Test
Slump (in):
Air Content (' %t):
Concrete Temp. (F):
Ambient Temp. (F):
Plastic Unit Wt. (pef):
Result
3
5.0
74
68
145.5
Specification
Laboratory Test Data
Set Specimen
No. ID
Diameter Area
(in)
(sq in)
6.00
28.27
6.00
28.27
6.00
28.27
Date
Received
04/23/09
04/23/09
04/23/09
Sample Information
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
04/22/09 Sample Time: 0745
Francisco J. Morillo
Clear
20 Bateli Size (cy): 10
Direct Discharge
0
0
See Placement Location
Paving, Intersection of Park St. &
Coppell Rd.
Age at
Maximum
Date Test
Load
Tested (days)
(lbs)
04/29/09 7
157,820
05/20/09 28
05/20/09 28
Compressive
Strength Fracture
(psi) Type
5,580 2
Comments:
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement location$ perform required field tests and cast compressive strength
samples.
Terracon Rep.: Francisco J. Morillo Started: 0600
Reported To: Superintendent Finished: 0900
Contractor: Tiseo
Report Distribution:
(1) Cily of Coppell 'I X (1) Htlill Z011;11 Inc
(1)'rise0 Paving company
Reviewed By:
Eric J. Cleveland, P.E.
Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Page Pa I of I Grated 6/142007
I'It -n0u1 g Revised 5112009