ST0003-LR090427CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94081 163.0090 Irer
Service Date: 04/17/09 8901 Carpenter Frwy, Ste 100
Report Date: 04/27/09 Dallas, TX 75247
214 -630 -1010 Reg No: F -3272
Client Project
City of Coppell TX Coppell Road - #ST00 -03
Attn: Albert Samaniego Sandy Lake Road to
Engineerin- Dept Cooper Lane
PO Box 9478 Coppell, TX
Coppell, TX 75019 Project Number: 94081163
Material Information Sample Information
Specified Strength: 4,000 psi @ 28 days
Mix ID: 25011-1
Supplier: Tiseo Paving
Batch Time: 0838
Truck No.: 184
Field Test Data
Test
Slump (in):
Air Content (' %;):
Concrete Temp. (F):
Ambient Temp. (F):
Plant:
Ticket No.:
Result Specification
4 1/2
5.0
85
64
Plastic Unit Wt. (pcf): 151.0
Laboratory Test Data
Set Specimen
Diameter
Area
Date
No. ID
(in)
(sq in)
Received
1 1
6.00
28.27
04/18/09
1 2
6.00
28.27
04/18/09
1 3
6.00
28.27
04/18/09
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
0,4/17/09 Sample Time: 0915
Ashton L. Varnell
Rain
10 Batch Size (cy): 10
Direct Discharge
10
0
Eastbound approach, Archer at street
Pavement eastbound approach at Archer
and westbound at Park
Age at Maximum Compressive
Date Test Load Strength Fracture
Tested (days) (lbs) (psi) Type
04/24/09 7 167,860 5,940 4
05/15/09 28
05/15/09 28
Comments:
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast compres7 strength
samples. �
Terracon Rep.: Ashton L. Varnell Started: 0600 /al/ D
Reported To:
Contractor: Tiseo
Report Distribution:
(1) City of Coppell Tx
(I)'risco Paving compa
(1) Huill Zollars Inc
Finished: 1 100
Reviewed By:
Senior Projebt Engineer
Test Methods: ASTM C 31, ASTM 09, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
e ie -anal
Page e I of I Created 8/14/2007
Revised 4/27/2009